• Title/Summary/Keyword: Operation Characteristics

Search Result 7,669, Processing Time 0.042 seconds

Implications of a Case Analysis of a Public Park Project at a Former Military Facility Site (군사시설 이전부지 공원화 사례분석을 통한 시사점 도출)

  • Park, Joon-Young;Lee, Eun-Yeob;Song, Sun-Young;Yeob, Jung-Sik
    • Land and Housing Review
    • /
    • v.5 no.4
    • /
    • pp.225-234
    • /
    • 2014
  • Because of their nature as public facilities, demands that former military facilities be utilized for the public welfare are increasing, thereby leading to an increase in cases in which these military facilities are reestablished as parks. Cases in which former military bases were reestablished as public parks were analyzed; as a result, several implications were derived. First, the objectives of public park projects should be examined from the perspective of the concept of urban regeneration and regional revitalization. Moreover, it is necessary that profits are yielded and that regional identity and history are reproduced through reusing existing facilities as much as possible rather than entirely remodeling former military sites. As parks become larger in size, bases should be reorganized into complexes rather than single facilities or programs. It is also necessary that parks be established in stages considering the enormous expenses required for building public parks. Consequently, because the special characteristics of military facilities can lead to insufficient on-site investigation in the process of establishing parks, thereby incurring a vast amount of costs for design adjustment and contamination disposal, this should be considered in advance. A method of delegating the development rights to partial sites to private businesses and supplementing the costs of park establishment and maintenance with development benefits should be examined. In addition, given that there are various interests and stakes in former military bases, a method of operating a public-private cooperative decision-making organization during project execution should be considered. Finally, policies related to urban parks need to be improved in order to raise funds, expand profitable businesses, facilitate social services and sponsorship, and encourage the participation of trusts and non-profit organizations in park operation and management.

Occupational Factors Influencing the Forklift Operators' Exposure to Black Carbon (지게차 운전원의 블랙카본(black carbon, BC) 노출에 영향을 미치는 직업적 요인)

  • Lee, Hyemin;Lee, Seunghee;Ryu, Seung-Hun;Park, Jihoon;Park, Dong-Uk
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.27 no.4
    • /
    • pp.313-323
    • /
    • 2017
  • Objectives: This study aimed to assess exposure to black carbon(BC) among forklift operators and to identify environmental and occupational factors influencing their BC exposure. Methods: We studied a total of 23 forklift operators from six workplaces manufacturing paper boxes. A daily BC exposure assessment was conducted during working hours from January to April 2017. A micro-aethalometer was used to monitor daily BC exposure, and information on work activities was also obtained through a time-activity diary(TAD) and interviews. BC exposure records were classified into four categories influencing BC exposure level: working environment, workplace, forklift operation, and job characteristics. Analysis of variance(ANOVA) was used to compare average BC exposure levels among the four categories and the relationships between potential factors and BC exposure were analyzed using a multiple linear regression model. Results: The operators' daily exposure was $12.9{\mu}g/m^3$(N=9,148, $GM=7.5{\mu}g/m^3$) with a range: $0.001-811.4{\mu}g/m^3$. The operators were exposed to significantly higher levels when they operate a forklift in a room ${\leq}20,000m^3$($AM=12.3{\mu}g/m^3$), in indoor workplaces($AM=16.3{\mu}g/m^3$), when they operate a forklift manufactured before 2006 ($AM=13.2{\mu}g/m^3$), a forklift with a loading limit of four-tons($AM=27.1{\mu}g/m^3$), with a roll and bale type clamp($AM=17.1{\mu}g/m^3$), and with no particulate filter($AM=15.7{\mu}g/m^3$). Conclusions: Occupational factors including temperature, smoking, season, daytime, room volume($m^3$), location of operating, and manufacturing era and model of forklift influenced the BC exposure of forklift operators. The results of this study can be used to minimize the BC exposure of forklift operators.

Assessment of Emitted Volatile Organic Compounds, Metals and Characteristic of Particle in Commercial 3D Printing Service Workplace (실제 3D 프린팅 작업장에서 발생하는 공기 중 유기화합물, 금속 및 입자특성 평가)

  • Kim, Sungho;Chung, Eunkyo;Kim, Seodong;Kwon, Jiwoon
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.30 no.2
    • /
    • pp.153-162
    • /
    • 2020
  • Objectives: 3D printing technologies have become widely developed and are increasingly being used for a variety of purposes. Recently, the evaluation of 3D printing operations has been conducted through chamber test studies, and actual workplace studies have yet to be completed. Therefore, the objective of this study was to determine the emission of volatile organic compounds(VOCs), metals, and particles from printing operations at a workplace. This included monitoring conducted at a commercial 3D printing service workplace where the processes involved material extrusion, material jetting, binder jetting, vat photo polymerization, and powder bed fusion. Methods: Area samples were collected with using a Tenax TA tube for VOC emission and MCE filter for metals in the workplace. For particle monitoring, Mini Particle Samplers(MPS) were also placed in the printer, indoor work area, and outdoor area. The objective was to analyze and identify particles' size, morphology, and chemical composition using transmission electron microscopy with energy dispersive spectroscopy(TEM-EDS) in the workplace. Results: The monitoring revealed that the concentration of VOCs and metals generated during the 3D printing process was low. However, it also revealed that within the 3D printing area, the highest concentration of total volatile organic compounds(TVOC) was 4,164 ppb at the vat photopolymerization 3D printing workplace, and the lowest was 148 ppb at the material extrusion 3D printing workplace. For the metals monitoring, chromium, which, is carcinogenic for humans, was detected in the workplace. As a characteristic of the particles, nano-sized particles were also found during the monitoring, but most of them were agglomerated with large and small particles. Conclusions: Based on the monitoring conducted at the commercial 3D printing operation, the results revealed that the concentration of VOCs and metals in the workplace were within Korea's occupational exposure limits. However, due to the emission of nano-sized particles during 3D printing operations, it was recommended that the exposure to VOCs and metals in the workplace should be minimized out of concern for workers' health. It was also shown that the characteristics of particles emitted from 3D printing operations may spread widely within an indoor workplace.

A Dynamic Reorganization Method using the Hierarchical Structure in the Grid Database (그리드 데이터베이스에서 계층 구조를 이용한 동적 재조직 기법)

  • Cheon, Jong-Hyeon;Jang, Yong-Il;Cho, Sook-Kyoung;Lee, Soon-Jo;Bae, Hae-Young
    • Journal of Korea Spatial Information System Society
    • /
    • v.8 no.1 s.16
    • /
    • pp.93-106
    • /
    • 2006
  • A Grid Database is a database management system to process effectively and use the distributed data in a grid computing environment. Spatial data is more important than other general data according to the local characteristics and requires a large storage. The grid database can be used as the optimal system for the management of the spatial data. However, contrary to the conventional distributed database systems, the Grid Database which guarantees the local autonomy has a possibility not to provide an effective system, or it is impossible to use a centralized management environment. In order to allow flexible responses to a dynamically changing environment, it is required to use effectively reorganized method. In this paper, hierarchical reorganization method is presented for dynamic reorganization in a grid database. When the reorganization is conducted, an organizer is created to collect the information of databases. In addition, the organizer which is constructed by the hierarchical structure supports information communication and reorganization, and then it allows the support of regional reorganization operation and effective balance control. The performance assessment of the proposed method shows that the processing capacity is increased after the reorganization.

  • PDF

Optical Diagnostics of Nanopowder Processed in Liquid Plasmas

  • Bratescu, M.A.;Saito, N.;Takai, O.
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2011.02a
    • /
    • pp.17-18
    • /
    • 2011
  • Plasma in liquid phase has attracted great attention in the last few years by the wide domain of applications in material processing, decomposition of organic and inorganic chemical compounds and sterilization of water. The plasma in liquid is characterized by three main regions which interact each - other during the plasma operation: the liquid phase, which supply the plasma gas phase with various chemical compounds and ions, the plasma in the gas phase at atmospheric pressure and the interface between these two regions. The most complex region, but extremely interesting from the fundamental, chemical and physical processes which occur here, is the boundary between the liquid phase and the plasma gas phase. In our laboratory, plasma in liquid which behaves as a glow discharge type, is generated by using a bipolar pulsed power supply, with variable pulse width, in the range of 0.5~10 ${\mu}s$ and 10 to 30 kHz repetition rate. Plasma in water and other different solutions was characterized by electrical and optical measurements. Strong emissions of OH and H radicals dominate the optical spectra. Generally water with 500 ${\mu}S/cm$ conductivity has a breakdown voltage around 2 kV, depending on the pulse width and the repetition rate of the power supply. The characteristics of the plasma initiated in ultrapure water between pairs of different materials used for electrodes (W and Ta) were investigated by the time-resolved optical emission and the broad-band absorption spectroscopy. The deexcitation processes of the reactive species formed in the water plasma depend on the electrode material, but have been independent on the polarity of the applied voltage pulses. Recently, Coherent anti-Stokes Raman Spectroscopy method was employed to investigate the chemistry in the liquid phase and at the interface between the gas and the liquid phases of the solution plasma system. The use of the solution plasma allows rapid fabrication of the metal nanoparticles without being necessary the addition of different reducing agents, because plasma in the liquid phase provides a reaction field with a highly excited energy radicals. We successfully synthesized gold nanoparticles using a glow discharge in aqueous solution. Nanoparticles with an average size of less than 10 nm were obtained using chlorauric acid solutions as the metal source. Carbon/Pt hybrid nanostructures have been obtained by treating carbon balls, synthesized in a CVD chamber, with hexachloro- platinum acid in a solution plasma system. The solution plasma was successfully used to remove the template remained after the mesoporous silica synthesis. Surface functionalization of the carbon structures and the silica surface with different chemical groups and nanoparticles, was also performed by processing these materials in the liquid plasma.

  • PDF

The Separation of Particulate within PFC Decontamination Wastewater Generated by PFC Decontamination (PFC 제염 후 발생된 제염폐액 내 오염입자의 제거)

  • Kim Gye-Nam;Lee Sung-Yeol;Won Hui-Jun;Jung Chong-Hun;Oh Won-Zin;Park Jin-Ho;narayan M.
    • Proceedings of the Korean Radioactive Waste Society Conference
    • /
    • 2005.06a
    • /
    • pp.32-39
    • /
    • 2005
  • When PFC(Perfluorocarbonate) decontamination technology is applied to removal of radioactive contaminated particulate adhered at surface during the operation of nuclear research facilities, it is necessary to develop a filtration equipment to reuse of PFC solution due to high price, also to minimize the volume of second wastewater. Contaminated characteristics of hot particulate was investigated and a filtration process was presented to remove suspended radioactive particulate from PFC decontamination wastewater generated on PFC decontamination. The range of size of hot particulate adhered at the surface of research facilities measured by SEM was $0.1{\sim}10{\mu}m$. Hot particulate of more than $2{\mu}m$ in PFC contamination wastewater was removed by first filter and then hot particulate of more than $0.2{\mu}m$ was removed by second filter. Results of filter experiments showed that filtration efficiency of PVDF(Poly vinylidene fluoride), PP(Polypropylene), Ceramic filter was $95{\sim}97\%$. A ceramic filter showed a higher filtration efficiency with a little low permeate volume. Also, a ceramic of inorganic compound could be broken easily on experiment and has a high price but was highly stable at radioactivity in comparison of PVDF and PP of a macromolecule which generate $H_2$ gas in alpha radioactivity environment.

  • PDF

Microbial Risk Analysis of Cooked Foods Donated to Foodbank(I) (푸드뱅크 기탁 조리식품의 미생물학적 위해분석(I))

  • Park, Hyung-Soo;Ryu, Kyung
    • Korean Journal of Community Nutrition
    • /
    • v.12 no.5
    • /
    • pp.617-629
    • /
    • 2007
  • To ensure the microbiological safety of food items prepared after cooking process, this study was aimed to identify the hazards related with cooked foods donated to foodbanks through quantitative microbial analysis. Five foodbanks located in Incheon and Gyeonggi area among government-dominant foodbanks were surveyed from February to June, 2007. Manager, recipient, donator, type and quantity of donated foot and facility and equipment were examined for the general characteristics of foodbank. The time and temperature of food md environment were measured at steps from after-production to before-distribution, and the microbial analysis was performed mainly with indicator organism and major pathogens. The amount of cooked foods donated to each foodbank was about 20 to 30 servings and consisted of 80% of total donated foods. Only three foodbanks had separate offices for foodbank operation and four institutions had at least one temperature-controlled vehicle. The flow of donated foods was gone through the steps; production, meal service and holding at donator, collection by foodbank, transport (or holding after transport) and distribution to recipients. It took about 3.8 to 6.5 hours at room temperature from after-production to before-distribution. Only aerobic plate counts (APC) and coliforms were found in microbial analysis. The APC after production were relatively high in $8.2{\times}10^5,\;7.4{\times}10^5,\;6.9{\times}10^5$ and $4.2{\times}10^5 CFU/g$ while $2.8{\times}10^6, \;9.4{\times}10^5,\;1.0{\times}10^6$ and $5.4{\times}10^5CFU/g$ before distribution in mixed Pimpinella brachycarpa, mixed chard mixed amaranth and mixed spinach, respectively. The levels of coliforms in mixed chard and mixed spinach were complied with the standards of the Ministry of Education and Human Resources Management The level of APC in boiled pork was increased from $< 1.0{\times}10 CFU/g$ to $4.0{\times}10^2 CFU/g$. One of delivery vessels was shown $6.2{\times}10^3 CFU/100 cm^2$ in APC, which was over the standards for environment. One of serving tables also showed the high level of $1.2{\times}10^3 CFU/100 cm^2$ in APC and $6.6{\times}10^2 CFU/100 cm^2$ in coliforms. These results suggest the sanitary management of holding at donator and the time-temperature control are key factors to ensure the safety of cooked foods donated to foodbank.

Fresh Water Injection Test in a Fractured Bedrock Aquifer for the Mitigation of Seawater Intrusion (해수침투 저감을 위한 균열암반 대수층 내 담수주입시험)

  • Shin, Je-Hyun;Byun, Joong-Moo
    • Economic and Environmental Geology
    • /
    • v.43 no.4
    • /
    • pp.371-379
    • /
    • 2010
  • Fresh water injection test in a fractured bedrock aquifer was applied as an efficient approach to lower saline concentrations in the saltwater-freshwater transition zone formed by seawater intrusion in a coastal area. The methodology and effectiveness of fresh water injection for hydraulically controlling seawater intrusion is overwhelmingly site dependent, and there is an urgent need to characterize the permeable fractures or unconsolidated porous formations which can allow for seawater flow and transport. Considering aquifer characteristics, injection and monitoring boreholes were optimally designed and completed to inject fresh water through sand layer and fractured bedrock, respectively. We devised and used the injection system using double packer for easy field operation and maintenance. Overall fracture distribution was systematically identified from borehole image logs, and the section of fresh water injection was decided from injection test and monitoring. With fresh water injection, the fluid electrical conductivity of the monitoring well started to be lowered by the inflow of fresh water at the specific depth. And this inflow leaded to the replacement of the fluid in the upper parts of the borehole with fresh water. Furthermore, the injection effect lasted more than several months, which means that fresh water injection may contribute to the mitigation of seawater intrusion in a coastal area.

Electrical properties of n-type $WO_{3}$ based gas sensors (N-형 $WO_{3}$계 가스센서의 전기적 특성)

  • Yang, Jong-In;Kim, Il-Jin;Lim, Han-Jo;Han, Sang-Do;Chung, Kwan-Soo
    • Journal of Sensor Science and Technology
    • /
    • v.7 no.3
    • /
    • pp.188-196
    • /
    • 1998
  • The sensing and electrical characteristics of $WO_{3}$-based n-type semiconductor gas sensors are investigated. In normal air condition, $TiO_{2}$(4 wt. %)-doped $WO_{3}$-based sensor fabricated without any binder shows the grain boundary ( GB ) potential barrier height of 0.26 V. Sensors fabricated with alumina, PVA and silica sol binders show 0.17, 0.22 and 0.26 V of GB potential barrier height, respectively. In the ambience of 120 ppm $NO_{x}$ concentration, the GB potential barrier height of the sensor fablicated without binder is increased to 0.59 V. The sensors were fabricated with alumina, PVA, silica sol binders show 0.43, 0.66 and 0.52 V of potential barrier, respectively. Thus the variation of the potential barrier at GB is largest in the sensor fabricated with the PVA binder. This is found to be the main reason why the sensor fabricated with the PVA binder shows the best sensitivity. It is also found that the decrease of sensitivity at a temperature higher than the optimum operation temperature is due to the temperature dependence of the sensor resistance in normal air condition rather than the desorption of the adsorbed $NO_{x}$ gas particles. In the ambience of 250 ppm CO concentration, the GB potential barrier heights of the sensors fabricated without binder and with PVA binder are about 0.2 V showing negligible change compared to the case of normal air ambience. This fact indicates that these sensors are good candidates for the selective detection of $NO_{x}$ gas in the mixture of CO and $NO_{x}$ gases.

  • PDF

A Study of the Apply Proximity Sensor for Improved Reliability Axle Detection (열차 차축검지 신뢰성 향상을 위한 근접센서 방식 Axle Counter 적용 연구)

  • Park, Jae-Young;Choi, Jin-Woo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.8
    • /
    • pp.5534-5540
    • /
    • 2015
  • This In the railway signaling system, applications of axle counter in addition to track circuit goes on increasing for detecting train position. Consequently, this paper compares sensor methods of axle counter with between geo-magnetism method and proximity sensor method. And it presents differences and results, to improve reliabilities of train detection and axle counting. Also, this article presents an applied result which is based on field experience, with regard to installation, considering attachment condition of sensor part for accurate axle counting. This study acquires expandability that is able to perform not only axle counting function but also various other functions (direction detection of train, speed detection of train, and so on). It was a result of a change of design in order to judge phase difference of sensors, to improve reliability of axle counting. Furthermore, it does not subordinate to characteristics (type, weight of train). And it is confirmed that the omission of axle counting was not occurred in 350km/h. This was the result of Lab test after the construction of transfer equipment of trial axle and Test Bed for axle counting. Both of them are self-productions. Through this, it prepares foundation which is able to apply not only to train detection but also to speed of passing trains, formation number of trains, detector locking condition - when the train passes the section of switch point, and level crossing devices. Furthermore, it would be judged to contribute safety train operation if proximity sensor method applies to the whole railway signaling system from now on.