• Title/Summary/Keyword: Operation Characteristics

Search Result 7,718, Processing Time 0.038 seconds

A Study on the Optimum Design of Multiple Screw Type Dryer for Treatment of Sewage Sludge (하수슬러지 처리를 위한 다축 스크류 난류 접촉식 건조기의 최적 설계 연구)

  • Na, En-Soo;Shin, Sung-Soo;Shin, Mi-Soo;Jang, Dong-Soon
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.34 no.4
    • /
    • pp.223-231
    • /
    • 2012
  • The purpose of this study is to investigate basically the mechanism of heat transfer by the resolution of complex fluid flow inside a sophisticated designed screw dryer for the treatment of sewage sludge by using numerical analysis and experimental study. By doing this, the result was quite helpful to obtain the design criteria for enhancing drying efficiency, thereby achieving the optimal design of a multiple screw type dryer for treating inorganic and organic sludge wastes. One notable design feature of the dryer was to bypass a certain of fraction of the hot combustion gases into the bottom of the screw cylinder, by the fluid flow induction, across the delicately designed holes on the screw surface to agitate internally the sticky sludges. This offers many benefits not only in the enhancement of thermal efficiency even for the high viscosity material but also greater flexibility in the application of system design and operation. However, one careful precaution was made in operation in that when distributing the hot flue gas over the lump of sludge for internal agitation not to make any pore blocking and to avoid too much pressure drop caused by inertial resistance across the lump of sludge. The optimal retention time for rotating the screw at 1 rpm in order to treat 200 kg/hr of sewage sludge was determined empirically about 100 minutes. The corresponding optimal heat source was found to be 150,000 kcal/hr. A series of numerical calculation is performed to resolve flow characteristics in order to assist in the system design as function of important system and operational variables. The numerical calculation is successfully evaluated against experimental temperature profile and flow field characteristics. In general, the calculation results are physically reasonable and consistent in parametric study. In further studies, more quantitative data analyses such as pressure drop across the type and loading of drying sludge will be made for the system evaluation in experiment and calculation.

A Study on the Health Care Satisfaction and Attitude of Elementary School Students - by the presence or absence of nurse teacher - (초등학생의 보건관리 만족도와 태도에 관한 연구 - 양호교사 유무를 중심으로 -)

  • Park, Dong-Kwon;Park, Young-Soo
    • The Journal of Korean Society for School & Community Health Education
    • /
    • v.1 no.2
    • /
    • pp.49-71
    • /
    • 2000
  • The purpose of this study was to serve as a basis for school health care of better quality, by making a comparative analysis of the health care satisfaction and attitude of elementary school students in consideration of their general characteristics and the presence or absence of nurse teacher. The subjects in this study were 919 selected six graders in 16 elementary schools in the city of Tongduchun, Koyang and Euijungbu, Yangju-kun and Yeunchun-kun. A survey was conducted with questionnaire designed for measurement of health care satisfaction and attitude. As a result of analyzing the data collected from June 1 through 15, 2000, the conclusions were as follows. 1) As for the general characteristics of the students investigated, the subjects included 513 boys(55.8%) and 406 girls(44.2%). The schools where 390(42.4%) students attended were located in municipal area, and the schools where 529(57.6%) students attended were located in kun area. 608(66.2%) students had a nurse teacher at their schools, while 311(33.8%) students had no nurse teacher. 498(54.2%) had an experience to use the health room this year, but 421(45.8%) had no such an experience. Their mean school life satisfaction was scored $3.42{\pm}.71$, above the average. And their health condition was rated $3.81{\pm}.87$, which implied they tended to be in good health. 2) The mean satisfaction at the health room operation was scored $3.33{\pm}.71$, above the medium level. What they were most satisfied with($4.02{\pm}1.08$) was, among the health room facilities, that there were beds. But they expressed the least satisfaction($2.83{\pm}1.17$) at the location of health room. The presence or absence of nurse teacher made a significant difference to their satisfactionat health room operation, because the students in schools with nurse teacher showed greater satisfaction($3.42{\pm}.72$) than the others in schools with no nurse teacher did($3.15{\pm}.66$). 3) Concerning their attitude to use the health room in case of disease or accident occurrence, a lot of students in schools with a nurse teacher, who had ever suffered from indigestion, headache or traumatic injury, used the health room. In schools with no nurse teacher, there was a tendency to talk to their class teachers(p<.001). The recognition of the necessity for health counseling was generally on a medium level. The counselor whom they wanted to discuss health problem with was family or friend in the largest cases. Few students discussed with class teachers in case there was a nurse teacher in school. Instead, some of them discussed with friend, family or nurse teacher, and there was a significant difference between them(p<.001). 4) The mean satisfaction at health, sanitation and environmental management was rated $3.20{\pm}.90$, above the average. The classroom lighting gave them the best satisfaction with $3.67{\pm}1.07$, but the satisfaction at toilet cleanness and disinfection was not good with $2.83{\pm}1.19$. By the presence or absence of nurse teacher, those who had a nurse teacher expressed better satisfaction at water supply facilities including hot water than the others who had no nurse teacher did(p<.001). But no significant difference was observed in the other items. 5) The health education satisfaction was rated $3.19{\pm}.99$, which was on a medium level. By item, the mean satisfaction level was $3.36{\pm}1.19$ at nurse teacher's explanation about treatment, $3.13{\pm}1.15$ at the frequency of health education, and $3.08{\pm}1.16$ at the explanation on the cause of disease. By the presence or absence of nurse teacher, the students with nurse teacher showed significantly better satisfaction at every factor0(p<.001). 6) Regarding health education attitude, their recognition of the need for school health education was scored $3.89{\pm}.96$. Those who had a nurse teacher felt it more necessary($3.96{\pm}.92$), yet the others who had no nurse teacher felt its necessity a little less($3.74{\pm}1.01$). The most preferred thing for them to learn in health education was first aid, followed by sex education, obesity prevention, safety accident prevention in school and outdoors, smoking-related health, good use of leisure time, and environmental pollution cause in the order named. According to the presence or absence of nurse teacher, there was a significant difference in sex education(p<.01), but no significant disparities were found in the other factors. The most preferred person who would offer health education was a lecturer from the outside(45.8%) and nurse teacher(45.4%). Their preference for class teacher as a person in charge of health education was just 8.8%. But the presence or absence of nurse teacher didn't produce any differences to their preference for a person in charge of health education.

  • PDF

Coronary Artery Bypass Graft Surgery in Patients 70 Years of Age and Older (70세 이상 고령 환자에서의 관상동맥우회술)

  • Park Jong Un;Lee Weon Yong;Kim Kun Il;Hong Ki Woo;Chee Hyun Keun;Shin Yoon Cheol;Lee Jae Woong;Kim Eung Jung
    • Journal of Chest Surgery
    • /
    • v.39 no.1 s.258
    • /
    • pp.28-34
    • /
    • 2006
  • Background: There has been an increase in the number of elderly patients considered for coronary artery bypass grafting (CABG). Recently, there were many satisfactory reports of coronary artery bypass grafting (CABG) in old age due to the development in operative technique and postoperative management. We evaluated operative and follow-up results of patients 70 years of age and older compared to 60 years old. Material and Method: We retrospectively studied the cases of 74 consecutive patients 70 years or older (group A) who underwent a elective CABG from January 2000 to December 2003 and compared that of relatively young age group (group B, 60-69 years old). We compared preoperative characteristics, operation technique, postoperative results that effect outcome, also we investigated late mortality and cardiac events at follow-up periods. Result: Preoperative demographic and clinical characteristics of two groups were not different, except preoperative renal dysfunction(serum creatinine: $\geq$1.4 mg/dl) (group A 17, 23$\%$ vs group B 14, 9$\%$) (p=0.024). There was no difference of the mean number of distal anastomosis and the left ventricular ejection fraction in group A decreased significantly from 53.7$\pm$13$\%$ preoperatively to 49.9$\pm$ 12$\%$ postoperatively (p=0.02), but not changed in group B. There was no difference at operative mortality rate and postoperative major morbidity rate, but wound problem of saphenous vein harvest site was significantly higher in group A than group B (6.8$\%$ vs 0.7$\%$, p=0.02). The mean follow up duration was 24.3$\pm$13 months and the cumulative survival were 95.4$\%$ at 2 year and 79.9$\%$ at 4 year in group A and 95.4$\%$ at 2 year and 90.1$\%$ at 4 year in group B (p=ns). Conclusion: We conclude that age is not a factor of determination when we decide about operation because coronary artery bypass grafting in elderly more than 70 years old can be performed with a low mortality rate and acceptable morbidity rate.

The Preference Analysis of Forest Therapy Program with regard to MBTI Personality Types (MBTI 성격유형에 따른 산림치유 프로그램 선호도에 관한 연구)

  • Kim, Youn-Hee;Kim, Dong-Jun;Kim, Eun-Jin;Yeoun, Pyung-Sik;Choi, Byung-Jin;Kim, Jea-Kean;Kim, Youn-Soo
    • Korean Journal of Environment and Ecology
    • /
    • v.29 no.3
    • /
    • pp.485-498
    • /
    • 2015
  • The need for forest therapy programs has been increasing. For more effective forest healing, it is necessary to identify the characteristics of participants and develop and operate more targeted and differentiated forest therapy programs accordingly. In this study, the relationships between MBTI (Myers-Briggs Type Indicator) personality types and the relationship between the temperaments of MBTI and the preference for the forest therapy programs were analyzed respectively in pursuit of the basic data required for the effective development and operation of forest healing on the basis of individual characteristics. The survey on the forest therapy program and MBTI personality tests were conducted for 245 normal adults. Using the SPSS 21.0 program analysis, data were analyzed by Analysis of variance (ANOVA) to obtain the difference of preference on the forest therapy program according to the personality type. The Extraversion(E)-Introversion(I) types showed differences in technique-based breathing exercises, walking in the forest(wearing shoes), laughter therapy in the forest, viewing the forest, forest bathing, wind bathing and sun bathing. And the Sensing(S)-iNtuition (N) types had marked differences in listening to the sound of water flowing, drinking herbal tea and sleeping in the forest. The Thinking (T) -Feeling (F) types marked differences in soaking hands and feet in water and sleeping in the forest. The Judging (J)-Perceiving (P) types had differences in vision quest and viewing the forest, respectively, in statistics. Depending on the temperament of the character, there were statistically significant differences in preferences such as drinking herbal tea, eating natural food, sleeping in the forest, viewing the forest and listening to the forest commentary. The results of this study are expected to be used as a basis for forest healing program development and operation.

A Study on the Water Exchange Plan with Disaster Prevention Facilities in Masan Bay (마산만 재해방지시설을 이용한 해수교환 방안에 관한 연구)

  • Kim, Gweon-Su;Ryu, Ha-Sang;Kim, Kang-Min
    • Journal of Navigation and Port Research
    • /
    • v.37 no.6
    • /
    • pp.637-645
    • /
    • 2013
  • Masan bay with a semi-enclosed waters has serious water quality problems due to the low flow and river pollution load from land, and shows the vulnerable locational characteristics to storm surge. We are seeking the way of both operating disaster prevention facilities and water quality improvement measures in the bay. That is, the water was exchanged using the head difference occurred by operating disaster prevention facilities. The location of disaster prevention facilities was assumed to be in the inlet of the bay, in the vicinity of Machang bridge, and in the vicinity of Dot island and the operation time was assumed to be early morning hours(01~05) considering the number of shipping passage and annual tide, and spring tide of the largest head difference. In addition, the experiment case of water exchange including the in-outflow feeder pipe was tested. According to the simulation results, water exchange rate in all experiments has shown a steady increase. Water exchange rate of the whole of Masan bay in the case of present is 38.62%. The water exchange rate of the inside of Masan bay compared with the inlet of bay, appeared to be very low. Thus, we judged that the characteristics of semi-enclosed waters were well reproduced. On the results of the experiment of disaster prevention facilities and in-outflow feeder pipe, the case of the operation of disaster prevention facilities, water exchage rate is high compared with the case of present. And, the higer the operating frequency, the more water exchange is appeared. The cases of water exchange prevention facilities through the in-outflow feeder pipe caused by the head difference, also showed the higest improvement of the water quality. Compared with the south of Machang bridge, the effect of water exchange was better in the inlet of Masan bay and Dot island. On the other hand, the inlet of Masan bay is higer than Dot island as for water exchange of the whole of Masan bay, but opposite, water change rate including Masan inside was higher in the case of Dot island.

Characteristics of Seepage Water and Groundwater in a Coastal LPG Storage Cavern of Jeonnam (전남 해안 LPG 저장공동 유출수와 주변 지하수의 수질특성)

  • Lee, Jin-Yong;Choi, Mi-Jung;Kim, Hyun-Jung;Cho, Byung-Wook
    • Journal of Soil and Groundwater Environment
    • /
    • v.14 no.4
    • /
    • pp.33-44
    • /
    • 2009
  • Water curtain of an underground LPG storage cavern is a facility to prevent leakage of high pressure gases, for which groundwater should flow freely towards the cavern and groundwater level also must be stably maintained. In this study, in order to evaluate qualities of seepage water and surrounding groundwater of an underground LPG storage cavern in Yeosu, 4 rounds of samplings, field measurements and laboratory analyses (February, May, August, October of 2007) were conducted. According to field measurements, pH was weak acidic to neutral but it gradually increased with time. Electrical conductivity (EC) of groundwater near a salt stack showed very high values between 10.47 and 38.50 mS/cm. Dissolved oxygen (DO) showed a very wide range of 0.20~8.74 mg/L and a mean of oxidation-reduction potential (ORP) was 159 mV, which indicated an oxidized condition. Levels of $Fe^{2+}$ and $Mn^{2+}$ were mostly less than 3 mg/L. All of seepage waters showed a Na-Cl type while only groundwater near the salt stack showed a Na-Cl type with a high total dissolved solid. The other groundwaters exhibited typical $Ca-HCO_3$ types. Levels of aerobic bacteria were mostly very high (573-39,520 CFU/mL). Based on the analyses of these hydrochemistry and biological characteristics, it is concluded that there are no particular problems in groundwater and seepage water, which not causing a trouble in the cavern operation. However, both for control of bio-clogging and for sustainable operation of the water curtain system, a regular hydrochemical and microbiological monitoring is required for the seepage water and surrounding groundwater.

A Study on the Level of Citizen Participation in Smart City Project (스마트도시사업 단계별 시민참여 수준 진단에 관한 연구)

  • PARK, Ji-Ho;PARK, Joung-Woo;NAM, Kwang-Woo
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.24 no.2
    • /
    • pp.12-28
    • /
    • 2021
  • Based on the global smart city promotion trend, in 2018, the "Fourth Industrial Revolution Committee" selected "sustainability" and "people-centered" as keywords in relation to the direction of domestic smart city policy. Accordingly, the Living Lab program, which is an active citizen-centered innovation methodology, is applied to each stage of the domestic smart city construction project. Through the Living Lab program, and in collaboration with the public and experts, the smart city discovers local issues as it focuses on citizens, devises solutions to sustainable urban problems, and formulates a regional development plan that reflects the needs of citizens. However, compared to citizen participation in urban regeneration projects that have been operated for a relatively long time, participation in smart city projects was found to significantly differ in level and sustainability. Therefore, this study conducted a comparative analysis of the characteristics of citizen participation at each stage of an urban regeneration project and, based on Arnstein's "Participation Ladder" model, examined the level of citizen participation activities in the Living Lab program carried out in a smart city commercial area from 2018 to 2019. The results indicated that citizen participation activities in the Living Lab conducted in the smart city project had a great influence on selecting smart city services, which fit the needs of local residents, and on determining the technological level of services appropriate to the region based on a relatively high level of authority, such as selection of smart city services or composition of solutions. However, most of the citizen participation activities were halted after the project's completion due to the one-off recruitment of citizen participation groups for the smart city construction project only. On the other hand, citizens' participation activities in the field of urban regeneration were focused on local communities, and continuous operation and management measures were being drawn from the project planning stage to the operation stage after the project was completed. This study presented a plan to revitalize citizen participation for the realization of a more sustainable smart city through a comparison of the characteristics and an examination of the level of citizen participation in such urban regeneration and smart city projects.

Fabrication of Portable Self-Powered Wireless Data Transmitting and Receiving System for User Environment Monitoring (사용자 환경 모니터링을 위한 소형 자가발전 무선 데이터 송수신 시스템 개발)

  • Jang, Sunmin;Cho, Sumin;Joung, Yoonsu;Kim, Jaehyoung;Kim, Hyeonsu;Jang, Dayeon;Ra, Yoonsang;Lee, Donghan;La, Moonwoo;Choi, Dongwhi
    • Korean Chemical Engineering Research
    • /
    • v.60 no.2
    • /
    • pp.249-254
    • /
    • 2022
  • With the rapid advance of the semiconductor and Information and communication technologies, remote environment monitoring technology, which can detect and analyze surrounding environmental conditions with various types of sensors and wireless communication technologies, is also drawing attention. However, since the conventional remote environmental monitoring systems require external power supplies, it causes time and space limitations on comfortable usage. In this study, we proposed the concept of the self-powered remote environmental monitoring system by supplying the power with the levitation-electromagnetic generator (L-EMG), which is rationally designed to effectively harvest biomechanical energy in consideration of the mechanical characteristics of biomechanical energy. In this regard, the proposed L-EMG is designed to effectively respond to the external vibration with the movable center magnet considering the mechanical characteristics of the biomechanical energy, such as relatively low-frequency and high amplitude of vibration. Hence the L-EMG based on the fragile force equilibrium can generate high-quality electrical energy to supply power. Additionally, the environmental detective sensor and wireless transmission module are composed of the micro control unit (MCU) to minimize the required power for electronic device operation by applying the sleep mode, resulting in the extension of operation time. Finally, in order to maximize user convenience, a mobile phone application was built to enable easy monitoring of the surrounding environment. Thus, the proposed concept not only verifies the possibility of establishing the self-powered remote environmental monitoring system using biomechanical energy but further suggests a design guideline.

Analysis of Local Government Environmental Impact Assessment (EIA) Ordinances and Preparation of Consultation Guidelinesfor EIA - A Case of Incheon Metropolitan City - (지방자치단체 환경영향평가 조례 현황 분석과 협의 지침서 작성 방안 - 인천광역시 사례를 중심으로 -)

  • Lee, Jongook;Cho, Kyeong Doo
    • Journal of Environmental Impact Assessment
    • /
    • v.31 no.4
    • /
    • pp.226-240
    • /
    • 2022
  • Local governments over a certain size in Republic of Korea may conduct Environmental Impact Assessment (EIA) considering regional characteristics if it is necessary, in accordance with Article 42 of the 「Environmental Impact Assessment Act」. However, it was investigated that the number of local government EIA operation in many local governments was less than initial expectations. In order to improve it, the status of ordinances and consultation guidelines which are different for each local government need to be compared, and the institutional issues forthe relevant local governments must be found considering regional characteristics. Furthermore, detailed regulation and guidance on the local government EIA procedure should be included in the consultation guidelines and related information need to be provided. In this study, focusing on the case of Incheon Metropolitan City, the status of local government EIA ordinances in metropolitan cities and provinces with a similar condition was investigated, and the types and scope of target projects were compared and analyzed. In addition, consultation guidelines forIncheon Metropolitan City were written, and improvements on the procedure flow and overall schedule designation derived from the process were presented. In the case of Incheon Metropolitan City, there were no detailed information officially announced regarding the regulations of the local government EIA ordinance and follow-up management, so the administrative system of the local government needed to be reinforced in this field. Meanwhile, considering the status of local environment and geography, some target project types were deemed necessary to be added: port construction projects, water resource development projects, railroad construction projects, and military facilities installation projects. The results of this study will provide useful information to local governments which want to improve their operation effectiveness by reorganizing the local government EIA system and preparing specific guidelines.

Totally Laparoscopic Distal Gastrectomy after Learning Curve Completion: Comparison with Laparoscopy-Assisted Distal Gastrectomy

  • Kim, Han-Gil;Park, Ji-Ho;Jeong, Sang-Ho;Lee, Young-Joon;Ha, Woo-Song;Choi, Sang-Kyung;Hong, Soon-Chan;Jung, Eun-Jung;Ju, Young-Tae;Jeong, Chi-Young;Park, Taejin
    • Journal of Gastric Cancer
    • /
    • v.13 no.1
    • /
    • pp.26-33
    • /
    • 2013
  • Purpose: The aims are to: (i) display the multidimensional learning curve of totally laparoscopic distal gastrectomy, and (ii) verify the feasibility of totally laparoscopic distal gastrectomy after learning curve completion by comparing it with laparoscopy-assisted distal gastrectomy. Materials and Methods: From January 2005 to June 2012, 247 patients who underwent laparoscopy-assisted distal gastrectomy (n=136) and totally laparoscopic distal gastrectomy (n=111) for early gastric cancer were enrolled. Their clinicopathological characteristics and early surgical outcomes were analyzed. Analysis of the totally laparoscopic distal gastrectomy learning curve was conducted using the moving average method and the cumulative sum method on 180 patients who underwent totally laparoscopic distal gastrectomy. Results: Our study indicated that experience with 40 and 20 totally laparoscopic distal gastrectomy cases, is required in order to achieve optimum proficiency by two surgeons. There were no remarkable differences in the clinicopathological characteristics between laparoscopy-assisted distal gastrectomy and totally laparoscopic distal gastrectomy groups. The two groups were comparable in terms of open conversion, combined resection, morbidities, reoperation rate, hospital stay and time to first flatus (P>0.05). However, totally laparoscopic distal gastrectomy had a significantly shorter mean operation time than laparoscopy-assisted distal gastrectomy (P<0.01). We also found that intra-abdominal abscess and overall complication rates were significantly higher before the learning curve than after the learning curve (P<0.05). Conclusions: Experience with 20~40 cases of totally laparoscopic distal gastrectomy is required to complete the learning curve. The use of totally laparoscopic distal gastrectomy after learning curve completion is a feasible and timesaving method compared to laparoscopy-assisted distal gastrectomy.