• Title/Summary/Keyword: Operating-Unit

Search Result 1,247, Processing Time 0.024 seconds

A Study on the Area Composition of the Operating Unit After Remodeling (수술부 리모델링을 통한 공간구성 변화에 관한 연구)

  • Kim, Khilchae
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.29 no.4
    • /
    • pp.57-67
    • /
    • 2023
  • Purpose: Recently, the operating unit remodeling compititon has been increasing rapidly in Korea, but there are no design infomation for spatial planning of sterile supply storage. Therefore, the propose of this study is to present area composition of the operating unit after remodeling. Methods: For literature review, the 6 studies and guidelines of operating unit(guidelines in the U.S, Australia, UK and Korea and 2 studies in Korea) conducted surveys and analysis. Room and space composition and zone of operating unit are redefined for this study. For obtaining area, to conduct masuring and calcuating of document of operating unit before and after remodeling in 3 cases. There are some patterns of plan in operaing unit by sterile supply storage. This study derived data for attributes of area composition of sterile supply storage. Results: The results of this study are as follows: First, Reviewing previous studies and Guidelines, for this study the suggested model was 5 zones(Operating zone, Support zone, Patient zone, Staff zone, Circulation zone) and redefined each room and space. Second, For infection control, sterile supply storage was provided to directly accessible to the operating room. Third, According to ralation of operting room and sterile supply storage, there are two types : 'double loaded type' and 'single loded type'. Sterile supply storage shall increase area of ciculation zone. Implications: This study can be used as primary data on remodeling of operating unit. In addition, it suggests that for infect control sterile supply storage is functional area.

A Study on the Space Composition of Hybrid Operating Unit in General Hospital (1) (종합병원 하이브리드수술유니트의 공간구성에 관한 연구 (1))

  • Kim, Byeong Soo;Chai, Choul Gyun
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.30 no.2
    • /
    • pp.23-34
    • /
    • 2024
  • Purpose: The Hybrid care environment, combining interventional procedures and surgeries in one space, is crucial for managing complex diseases, responding to emergencies, and reducing recovery times and pain. This study provides foundational data for creating architectural guidelines for a Hybrid Operating Unit in a general hospital's surgical department, focusing on cardiovascular care. Methods: The study analyzed the spatial and configuration types of the Vascular Angiography Unit and the Cardiac Operating Unit, which are the basic components of the Hybrid Operating Unit, through a literature review. Based on the initial research findings, interviews with experts were conducted. Results: In the Hybrid Operating Process, the study proposed spatial configuration alternatives that consider the positioning of medical staff and the types and arrangement changes of equipment, including Angiography, Heart-lung machines, and other surgical tools and instruments. Implications: The integration of the two units leads to increased diversity and demand for medical staff, equipment, and supplies during surgical and interventional procedures. Therefore, strategic spatial configurations and equipment placement are necessary to effectively respond to these needs.

Study of combinations of site operating states for multi-unit PSA

  • Yoo, Heejong;Jin, Kyungho;Heo, Gyunyoung
    • Nuclear Engineering and Technology
    • /
    • v.53 no.10
    • /
    • pp.3247-3255
    • /
    • 2021
  • As Probabilistic Safety Assessments (PSAs) are thoroughly conducted for the Site Operating States (SOSs) for a single unit, multi-unit Probabilistic Safety Assessments (MUPSAs) are ongoing worldwide to address new technical challenges or issues. In South Korea, the determination of the site operating states for a single site requires a logical approach with reasonable assumptions due to the fact that there are 4-8 operating units for each site. This paper suggests a simulation model that gives a reasonable expectation of the site operation states using the Monte-Carlo method as a stochastic approach and deterministic aspects such as operational policies. Statistical hypothesis tests were conducted so that the reliance of the simulation results can be guaranteed. In this study, 7 units of the Kori site were analysed as a case study. The result shows that the fraction of full power for all 7 units is nearly 0.45. For situations when more than two units are not in operation, the highest fraction combination was obtained for Plant Operation State (POS) 8, which is the stage of inspection and repairment. By entering various site operation scenarios, the simulation model can be used for the analysis of other site operation states.

An Empirical Study on the Effects of the Role of EA Operating Unit and EA Utilization Capability on the EA Performance (EA 담당조직의 역할과 EA 활용역량이 EA 성과에 미치는 영향에 관한 실증적 연구)

  • Park, Il-Kyu;Kim, Sang-Hoon;Seo, Il-Jung
    • Journal of Information Technology Services
    • /
    • v.9 no.1
    • /
    • pp.27-42
    • /
    • 2010
  • Recently, many organizations are actively adopting Enterprise Architecture (EA) as a methodology to manage IT assets and build IT-based business system. However, most existing studies on EA have focused on the adoption stage of EA. Now the research concerning effective management and utilization of EA after adopting EA is keenly required. This study intended to empirically examine how the role of EA operating unit and the EA utilization capability of organizational members impact on EA performance at the post-adoption stage of EA. Based on Resource Based View (RBV), this study proposed the model and the hypotheses describing that the impact of the role of EA operating unit on EA performance is mediated by the EA utilization capability of organizational members. In order to test the hypotheses, the field survey whose respondents were seventy four Korean public agencies which have adopted EA was conducted by means of questionnaire. Data analysis was done with partial least square (PLS), which is a structural equation modeling (SEM) technique that uses a component-based approach to estimation. The results of the empirical analyses showed that the organizational operation ability of EA operating unit significantly influenced EA performance via the EA utilization capability of organizational members, but that EA education and training performed by EA operating unit did not. The results of this study provided a lot of theoretical and practical implications regarding EA management activities at the post-adoption stage of EA to enhance EA performance.

A study on the Architectural Planning Program for the type and scale computation of Operating-Unit (수술유니트의 유형 및 규모 산정을 위한 건축계획 프로그램에 관한 연구)

  • Chai, Choul-Gyun
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.8 no.2
    • /
    • pp.43-50
    • /
    • 2002
  • By reason of development of anesthesia, advent of new surgical operation type and change of hygiene criterion and economical index is increasing recently request about alteration of existing unit or new surgical operation-unit type. The purpose of this study is to provide of architectural planning program for the type decision and the scale computation of operating-unit in healthcare facilities. As a result of this study, presented program of six type according to surgical operation process including space and time side.

  • PDF

A Study on Profitability of Power Plant for Landfill Gas (매립가스 자원화를 위한 가스엔진 발전의 수익성에 관한 연구)

  • Kim, Oh-Woo;Lee, Jeong-Il
    • Korean Business Review
    • /
    • v.19 no.2
    • /
    • pp.69-94
    • /
    • 2006
  • Landfill gas is a mixture of methane and carbon dioxide produced by the bacterial decomposition of organic wastes, and it is considered to produce bad smells and pollute the environment. Economic trials and the developments of landfill gas, as an alternative energy resource, become known at the recent years. Resource development of landfill gas, which is managed by Korea up to now, is for the most part generation using gas engine. Medium BTU and High BTU are considered for the power generation as well. I\10st income of generation using gas engine is selling charge through a power plant. Expecting to manage the power plant for up to 10 years, the analysis based on revenue and expenditure shows when the unit price is 65.2 Won and the operating rate reaches 90%, it is possible to be into the black in 2012 without considering additional financial expense. It was also analyzed that the profit at a unit price of 85 Won under the anticipated rising unit price by the operating rate of 71% is larger than at the operating rate of 90% under limited unit price of 65.2 Won. It means to manage the power plant at a unit price of 65.2 Won and the operating rate must be higher than 90% for economic logicality. If we assume that the operating rate is 90% and it increases the unit price, the unit price must be higher than 85 Won for the management of a power plant. Analysis of changing a unit price, however, might be expected to have a gradual rise of prices. If there is no price rising and additional income related to CDM(Clean Development Mechanism) and emission trading upon Kyoto protocol, the management of a power plant using gas engine will get financial difficulties because of many operating expenses. However, since landfill gas is considered as a worthy energy resource for the guarantee of sustainable development and for the equity between recent generation and future generation, the development of it must be accomplished by the government's additional supporting and efforts under the interest of all stakeholder who are involved.

  • PDF

Investigation on the Reduction Effect on Cooling Power Consumption and Operating Cost of Mist-spray Outdoor Units in Air Conditioner

  • Lee, Keon-ho;Cho, Dong-woo;Kim, Hyemi;Song, Young-hak
    • Architectural research
    • /
    • v.19 no.4
    • /
    • pp.101-108
    • /
    • 2017
  • The use of the air conditioner is increasing due to the rise of the outdoor temperature during summer, and the problems of the fire and the cooling performance deterioration are caused due to lack of maintenance of the outdoor unit. In particular, overall performance of cooling system and efficiency in outdoor units have been degraded due to an intake of high-temperature outdoor air thereby increasing cooling energy and operating cost. Thus, this study aimed to increase efficiency of outdoor units by evaporating and cooling intake air through mist spray at the intake port surface in the outdoor unit. The measurements results showed that total power consumption of misting outdoor unit compared to that of conventional outdoor units was reduced by 21% approximately, and total power consumption of the entire system including pump was reduced by 16.7%. In addition, the operating cost including water use was reduced by 13.5% approximately. In summary, if a mist-spray nozzle kit is installed in air-cooled outdoor units, the reduction in the usage of cooling energy and operating cost will be achieved without replacement of existing cooling systems or a large scale of repairs.

Experimental Study on Cooling Characteristics of Multi - Air Conditioner using Inverter Scroll Compressor (인버터 스크롤 압축기를 사용한 멀티 에어컨의 냉방 특성에 대한 실험적 연구)

  • 권영철;고국원;진의선;허삼행;전용호;이영덕;박인규
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.16 no.4
    • /
    • pp.311-317
    • /
    • 2004
  • In the present study, the cooling characteristics of the multi-air conditioner (A/C) using an inverter scroll compressor are experimentally investigated for the number of the indoor units and the operating conditions (2$0^{\circ}C$, 24$^{\circ}C$, 26$^{\circ}C$) under the cooling standard conditions by KS C 9306. In the case of the simultaneous operation for 3 indoor units, the cooling capacity, the mass flow rate and the input power have a decreasing trend and COP has an increasing trend, with decreasing the difference in the operating temperature of the indoor unit and the room temperature. In the case of the simultaneous operation for 2 indoor units, the COP of the indoor unit with large cooling capacity is high when the operating temperature is high, but the COP of the indoor unit with low cooling capacity is high when the operating temperature is low. In the case of the single operation for one unit, when the large cooling capacity of the indoor unit is less than 50% the compressor operates at the minimum operation frequency region and the COP decreases.

Optimal Operating Strategy of Distributed Generation Considering Hourly Reliability Worth (시간별 신뢰도 가치를 고려한 분산전원의 최적 운영전략)

  • 배인수;신동준;김진오
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.52 no.8
    • /
    • pp.457-462
    • /
    • 2003
  • This paper presents an optimal operating strategy of distributed generation (DG) with reliability worth evaluation of distribution systems. Using DG for peak-shaving unit could reduce the overall system operating cost, and using DG for standby power unit could reduce the customer interruption cost. If DG operating cost is less than utility power cost in peak time, DG should be running to reduce the overall system operating cost. When customer interruption cost enlarges, however, standby power strategy may be the better operating strategy than peak-shaving strategy. Selection of whether DG should be operated for peak-shaving or for standby power, needs the accurate reliability worth evaluation and the accurate power cost evaluation. Instead of using annual average reliability worth, the concept of hourly reliability worth is introduced in this paper to determine the optimal operating decision of DG. Applying suggested hourly reliability worth, the distribution companies that possess DG could set up the optimal operating strategy of DG.

A Windows Operating System based Control Display Unit for a Commercial High Precision Inertial Navigation System (상용 초정밀 관성항법시스템용 윈도우즈 운영체제 기반 CDU(Control Display Unit) 설계)

  • Kim, Jeong-Won;Shin, Dae-Sik;Hwang, Dong-Hwang;Lee, Sang-Jeong;Park, Yong-Woon
    • Proceedings of the KIEE Conference
    • /
    • 2005.10b
    • /
    • pp.101-103
    • /
    • 2005
  • This paper designs a CDU(Control Disaply Unit) for commercial high precision INS(Inertial Navigation System). The CDU is designed using GUI(Graphic User Interface) programming running on Windows operating system. Since the designed CDU provides standard functions of the Windows operating systems and has a modular structure, it is easy to modify and extend. The CDU has been interfaced to the H-726 INS, from which it's usefulness can be seen.

  • PDF