• Title/Summary/Keyword: Operating unit

Search Result 1,238, Processing Time 0.03 seconds

Relationship between the Flow data on the Unit Watersheds and on the Stream Flow Monitoring Network (수질오염총량관리 단위유역 유량자료와 하천유량 측정망 자료의 연계성 분석)

  • Park, Jun Dae;Oh, Seung Young
    • Journal of Korean Society on Water Environment
    • /
    • v.29 no.1
    • /
    • pp.55-65
    • /
    • 2013
  • It is very difficult to apply stream flow data directly to the management of Total Maximum Daily Loads because there are some differences between the unit watershed and the stream flow monitoring network in their characteristics such as monitoring locations and its intervals. Flow duration curve can be developed by linking the daily flow data of stream monitoring network to 8 day interval flow data of the unit watershed. This study investigated the current operating conditions of the stream flow monitoring network and the flow relationships between the unit watershed and the stream flow monitoring network. Criteria such as missing and zero value data, and correlation coefficients were applied to select the stream flow reference sites. The reference sites were selected in 112 areas out of 142 unit watersheds in 4 river basins, where the stream flow observations were carried out in relatively normal operating conditions. These reference sites could be utilized in various ways such as flow variation analysis, flow duration curve development and so on for the management of Total Maximum Daily Loads.

The Effect of Improved Operating Room and Intensive Care Unit on the Sternal Infection After Open Heart Surgery (집중치료실 및 수술장 개선이 개심술후 흉골감염에 미치는 영향)

  • 이종태;이상철;김성완;이응배;조준용;김덕실;장봉현;김규태
    • Journal of Chest Surgery
    • /
    • v.35 no.5
    • /
    • pp.375-380
    • /
    • 2002
  • Background: Sternal infection after open heart surgery is a serious complication associated with high rate of mortality. We reviewed the effect of improved operating room and intensive care unit un the sternal infection by analyzing the incidence and condition of that around the movement of operating room and intensive care unit in July 1997. Material and method: We reviewed a total of 453 patients. Group I contains 237 patients who underwent open heart surgery between January 1997 and December 1978 before we moved the intensive care unit and of operating room, and Group II contains 216 patients who underwent open heart surgery between January 2000 and July 2001 after we moved. We only included adult patients over age 15 who underwent cardiopulmonary bypass through median sternotomy and excluded the mortality cases except sternal infections in this study. Result: Sternal infection developed in 18 patients(8.0%) in Group I, and in only 1 patient(0.49%) in Group II. Emergency operation, cardiopulmonary bypass time, operation tilde, transfusion, tracheostomy, and reoperation are significantly associated with sternal infection among the known risk factors. The logistic regression analysis containing those six factors revealed that the movement of intensive care unit and operating roots is effective on the decreasing sternal infection(p=0.029, 95% confidence interval 0.011 ∼ 0.788). Conclusion: Although there have been studies on manly risk factors associated with the sternal infection after open heart surgery, we think that the improvement of operting room and intensive care unit is a method for decreasing the incidence of sternal infection.

Experimental Study on the Performance Improvement of a Simultaneous Heating and Cooling Heat Pump in the Heating-main Operating Mode (난방주체 운전모드에서의 동시냉난방 열펌프 성능향상에 관한 실험적 연구)

  • Kang, Hoon;Jung, Hyen-Joon;Joo, Young-Ju;Kim, Yong-Chan;Choi, Jong-Min
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.20 no.4
    • /
    • pp.245-251
    • /
    • 2008
  • The cooling load in winter is significant in buildings and hotels because of the usage of office equipments and the high efficiency of wall insulation. Hence, the development of a multi-heat pump that can cover heating and cooling simultaneously for each indoor unit is required. In this study, the operating characteristics and performance of a simultaneous heating and cooling heat pump in the heating-main operating mode were investigated experimentally. The system adopted a variable speed compressor with four indoor units and one outdoor unit with R-410A. In the heating-main mode, the cooling capacity was lower than the design cooling capacity due to the reduction of the flow rate in the indoor unit for the cooling, with the increase of the heating capacity. To solve these problems, the performance characteristics of the simultaneous heating and cooling heat pump in the heating-main mode were investigated by varying the flow rate to the indoor unit for the cooling and the compressor rotating speed. In addition, the adequate control methods were suggested to improve the system efficiency.

Implementation of 3-D Collision Avoidance Algorithm and Comparison of Micro Controller Unit's Performance using Real-Time Operating System (항공기 3차원 충돌회피 알고리즘 구현과 실시간 운영체계를 이용한 Micro Controller Unit의 성능 비교)

  • Lim, Ji-Sung;Kim, Dong-Sin;Park, In-Hyeok;Lee, Sangchul
    • Journal of Aerospace System Engineering
    • /
    • v.12 no.5
    • /
    • pp.48-53
    • /
    • 2018
  • In this study, Real-Time Operating System(RTOS) and 3-D collision avoidance algorithm are implemented to three different Miciro Controller Unit(MCU)s and their performances compared. We selected Microchip Technology's ATmega2560, STM's ARM Cortex-M3 and ARM Cortex-M4, because they are widely used. FreeRTOS, an open-source operating system, was also used. The 3D collision avoidance algorithm consists of the vertical and the horizontal avoidance algorithm, which is implemented using C++. The performances of the MCUs were compared with respect to used memory and calculation time. As a result, Cortex-M4's calculation time was the fastest and ATmega2560 used least memory.

A System Analysis of a Controllable Queueing Model Operating under the {T:Min(T,N)} Policy (조정가능한 대기모형에 {T:Min(T,N)} 운용방침이 적용되었을 때의 시스템분석)

  • Rhee, Hahn-Kyou
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.38 no.1
    • /
    • pp.21-29
    • /
    • 2015
  • A steady-state controllable M/G/1 queueing model operating under the {T:Min(T,N)} policy is considered where the {T:Min(T,N)} policy is defined as the next busy period will be initiated either after T time units elapsed from the end of the previous busy period if at least one customer arrives at the system during that time period, or after T time units elapsed without a customer' arrival, the time instant when Nth customer arrives at the system or T time units elapsed with at least one customer arrives at the system whichever comes first. After deriving the necessary system characteristics including the expected number of customers in the system, the expected length of busy period and so on, the total expected cost function per unit time for the system operation is constructed to determine the optimal operating policy. To do so, the cost elements associated with such system characteristics including the customers' waiting cost in the system and the server's removal and activating cost are defined. Then, procedures to determine the optimal values of the decision variables included in the operating policy are provided based on minimizing the total expected cost function per unit time to operate the queueing system under considerations.

Analysis of a Controllable M/G/1 Queueing Model Operating under the (TN) Policy ((TN) 운용방침이 적용되는 조정가능한 M/G/1 대기모형 분석)

  • Rhee, Hahn-Kyou
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.37 no.1
    • /
    • pp.96-103
    • /
    • 2014
  • A steady-state controllable M/G/1 queueing model operating under the (TN) policy is considered where the (TN) policy is defined as the next busy period will be initiated either after T time units elapsed from the end of the previous busy period if at least one customer arrives at the system during that time period, or the time instant when Nth customer arrives at the system after T time units elapsed without customers' arrivals during that time period. After deriving the necessary system characteristics such as the expected number of customers in the system, the expected length of busy period and so on, the total expected cost function per unit time in the system operation is constructed to determine the optimal operating policy. To do so, the cost elements associated with such system characteristics including the customers' waiting cost in the system and the server's removal and activating cost are defined. Then, the optimal values of the decision variables included in the operating policies are determined by minimizing the total expected cost function per unit time to operate the system under consideration.

Development of Regulatory Technology on Aging for Continued Operation of Wolsong Unit 1 (월성1호기 계속운전 경년열화 규제기술 개발)

  • Kim, Hong Key;Song, Myung Ho;Nho, Seung Hwan;Kim, Se Chang
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.7 no.4
    • /
    • pp.57-62
    • /
    • 2011
  • As NPPs' operating times increase, the integrity of nuclear components is continually degraded due to aging effects of systems, structures and components. In addition, for the case of continued operation beyond design life, additional aging effects occurred during the extended operating period lead to more degradation of the integrity of nuclear components. Therefore, it is very important to mange and evaluate the aging to secure the safety of NPPs. Wolsong unit 1 is approaching to its design life of 30 years in 2012. The license renewal documents for continued operation of Wolsong unit 1 Is under reviewing now. In this paper, regulatory technologies for continued operation of Wolsong unit 1 developed by KINS will be introduced. That technologies include the safety review guidelines, regulatory guides for aging management program and regulatory program for audit calculation.

Evaluation of Piping Failure Probability of Reactor Coolant System in Kori Unit 1 Considering Stress Corrosion Cracking (응력부식균열을 고려한 고리 1호기 원자로냉각재계통의 배관 파손확률 평가)

  • Park, Jeong Soon;Choi, Young Hwan;Park, Jae Hak
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.6 no.1
    • /
    • pp.43-49
    • /
    • 2010
  • The piping failure probability of the reactor coolant system in Kori unit 1 was evaluated considering stress corrosion cracking. The P-PIE program (Probabilistic Piping Integrity Evaluation Program) developed in this study was used in the analysis. The effect of some variables such as oxygen concentration during start up and steady state operation, and operating temperature, which are related with stress corrosion cracking, on the piping failure probabilities was investigated. The effects of leak detection capability, the size of big leak, piping loops, and reactor types on the piping failure probability were also investigated. The results show that (1) LOCA (loss of coolant accident) probability of Kori unit 1 is extremely low, (2) leak probability is sensitive to oxygen concentration during steady state operation and operating temperature, while not sensitive to the oxygen concentration during start up, and (3) the piping thickness and operating temperature play important roles in the leak probabilities of the cold leg in 4 reactor types having same inner diameter.

  • PDF

A Study on the Revision of Regulations for Effective Operation of Anchorage (정박지의 효율적 운영을 위한 세칙 개정방안)

  • Yun, Gwi-Ho
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.20 no.4
    • /
    • pp.398-404
    • /
    • 2014
  • The criteria of operating anchorage and the unit of anchorage capacity have not been unified and the different terms have been used in same matters in each regulations related to the anchorages provided in major domestic ports. The competent authorities and vessels which are going to use anchorages are confused due to those situations. This paper suggests the schemes to unify criteria of operating anchorage, the unit of anchorage capacity and terms used in same matters through reviewing the anchorage operating regulations provided in major domestic ports. In addition, this paper suggests that the principles of anchorage naming, the unit of anchorage capacity and the number of vessels that can be accommodated should be established at the next revision of regulations through reviewing the status of anchorages in major foreign ports to minimize the confusion on operating anchorages.

A study on the design of control unit for playback-type industrial robot (기억재생식 산업용로봇트의 제어부 설계에 관한 연구)

  • 송상섭;김승필;변증남
    • 전기의세계
    • /
    • v.29 no.7
    • /
    • pp.460-470
    • /
    • 1980
  • The design of a control unit for a playback-type industrial robot is studied. Implemented for the cylindrical-coordinate type industrial robot with 5 degrees of freedom, the control unit constructed for the study consists of (i) z-80 .mu.p-based .mu.-computer control system (ii) Teach-Box for work command, and (iii) various softwares for generating signals for servo driving unit and operating the robot as playback-type. Softwares are developed by using high level Basic Language and low level z-80 Assembly Language for ease of programming and speed of program execution. To show the effectiveness, and example is included.

  • PDF