• Title/Summary/Keyword: Operating region

Search Result 861, Processing Time 0.034 seconds

Transient Response of a Stratified Thermal Storage Tank to the Variation of Inlet Temperature

  • Yoo, Ho-Seon
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.6
    • /
    • pp.14-26
    • /
    • 1998
  • This paper deals with approximate analytical solutions for the two-region one-dimensional model describing the charging process of stratified thermal storage tanks at variable inlet temperature with momentum-induced mixing. An arbitrarily increasing inlet temperature is decomposed into inherent step changes and intervals of continuous change. Each continuous interval is approximated as a finite number of piecewise linear functions, which admits an analytical solution for perfectly mixed region. Using the Laplace transform, the temperature profiles in plug flow region with both the semi-infinite and adiabatic ends are successfully derived in terms of well-defined functions. The effect of end condition on the solution proves to be negligible under the practical operating conditions. For a Quadratic variation of inlet temperature, the approximate solution employing a moderate number of pieces agrees excellently with the exact solution.

  • PDF

Fast hierarchical image segmentation based on mathematical morphology (수리형태론에 기반한 고속 계층적 영상분할)

  • 김해룡;홍원학;김남철
    • Journal of the Korean Institute of Telematics and Electronics B
    • /
    • v.33B no.10
    • /
    • pp.38-49
    • /
    • 1996
  • In this paper, we propose a fast hierarchical image segmentation using mathematical morphology. The proposed segmentation method is composed of five basic steps; multi-thresholding, open-close by reconstructing, mode operation, marker extraction, and region decision. In the multi-thresholding, an input image is simplified by Lloyd clustering algorithm. The multi-thresholded image then is more simplified by open-close by reconstruction and mode operating. In the region decision, to which region each uncertainty pixel belongs finally is decided by a watershed algorithm. Experimental results show that the quality of the segmentation results by the proposed method is not inferior to that by the conventional method and the average times elapsed by the proposed method can be reduced by one tghird of those elapsed by the conventional method.

  • PDF

Evaluation of the Turbulence Models on the Aerodynamic Performance of Three-Dimensional Small-Size Axial Fan (3차원 소형축류홴의 공력특성에 대한 난류모델평가)

  • Kim, Jang-Kweon;Oh, Seok-Hyung
    • Journal of Power System Engineering
    • /
    • v.18 no.6
    • /
    • pp.13-20
    • /
    • 2014
  • The steady-state, incompressible and three-dimensional numerical analysis was carried out to evaluate turbulent models on the aerodynamic performance of a small-size axial fan(SSAF). The prediction performance on the static pressure of all turbulent models is going downhill at the high static pressure and low flowrate region, but has improved at the axial flow region. In consequence, all turbulent models predict the static pressure coefficient with an error performance less than about 4% after the region of the flowrate coefficient of about 0.14. Especially, the turbulent model of SST $k-{\omega}$ shows the best prediction performance equivalent to an error performance less than about 2% on the static pressure.

Factors Affecting the Operating Performance of General Hospitals (종합병원 수익성에 미치는 영향요인 분석)

  • Kim, Ji-Hyoung;Ha, Ho-Wook;Lee, Hae-Jong;Sohn, Tae-Yong
    • Korea Journal of Hospital Management
    • /
    • v.10 no.3
    • /
    • pp.45-66
    • /
    • 2005
  • The purpose of this study was to analyze related factors affecting profitability on general hospitals(300-499 beds). The data were derived from survey by the Korean Hospital Association on 33 hospitals during 10 years (from 1993 to 2002). Profitability was measured by 3 ratios - net profit to total assets, normal profit to total assets and operating margin to gross revenue - as dependent variables. Independent variables were classified by general factors (ownership, number of bed, period of establishment, region), financial factors (total asset turnover, current ratio, liabilities to total assets, personnel costs per operation profit, material costs per operation profits), productivity index(number of daily patient per nurse), the score of quality assurance activity and the time lag score. Multiple regression model was used in this study. First, Number of bed, region was not statistically significant for profitability. But ownership was affect positively to normal profit to total assets and operating margin to gross revenue. Private hospitals had higher profitability than that of public hospitals Second, the score of quality assurance activity was not statistically significant to profitability. Third, Those hospitals having more daily patient per nurse had significantly higher profitability than the others. Fourth, Those hospitals having higher proportion in total asset turnover had significantly higher profitability than other hospitals. But liabilities to total assets and liquidity ratio had no difference to the profitability. Those hospitals having higher proportion in personnel costs and material costs per operation profits had significantly lower hospital profitability than others.

  • PDF

A constant power and optimal power factor drive of doubly fed induction generator (이중여자 유도발전기의 정출력.최적역률 운전)

  • 이우석
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.14 no.4
    • /
    • pp.31-38
    • /
    • 2000
  • Wide operating range and speed control is needed for wind power generating and a Doubly Fed Induction Generator(DFIG) has good adaptivity for that purpose. This paper deals with the speed, power, and power factor control using the Grid connected DFIG in the super-synchronous speed regions, by controlling frequency and voltage fed to the rotor. Power flow of the DFIG and steady-state algebraic equations of the equivalent circuit are analyzed. The wind turbine speed and constant stator power were controlled by the rotor exciting frequency. For a normal operating region, in which the generator ratings were not exceeded, rotor exciting frequency. For a normal operating region, in which the generator ratings were not exceeded, the rotor current was either less than or equal to the rated value. Accordingly, the optimal power factor can be selected relative to the permissible rated current at the rotor coil which controls the magnitude of the injected rotor voltage to the rotor according to a given rotor frequency. Consequently, it is possible to determine the optimal drive of a DFIG for wind power generation application.

  • PDF

Numerical Simulation and PIV Measurement on the Internal Flow in a Centrifugal Mini Pump at Low Flow Rate Conditions

  • Yuan, Hui-Jing;Shao, Jie;Cao, Guang-Jun;Liu, Shu-Hong;Wu, Yu-Lin
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2008.03a
    • /
    • pp.775-780
    • /
    • 2008
  • This paper reports on the internal flow of a centrifugal mini pump working at the low flow rate operating conditions. The RNG $\kappa-\varepsilon$ turbulence model was employed to simulate the three-dimensional turbulent flow in the pump. To examine and certify the simulation results, a transparent acrylic centrifugal mini pump model which is suitable for PIV measurement has been developed. The tongue region and the passages region between blades were investigated using PIV. In order to eliminate the effect of refraction on the area closed to the wall and increase the measurement accuracy, the fluorescent particles were scatted into the working fluid with the tracing particles. It is found from the calculation and PIV measurement results that there is a large area of recirculation flow near the tongue at low flow rate operating conditions. The computationally predicted water head using the $\kappa-\varepsilon$ turbulence model at low flow rate operating conditions are in very good agreement with the experimentally measured water head and the mean velocity distributions at investigation area obtained by PIV and calculation showed a satisfactory agreement as well. Meanwhile, the results of PIV measurements show that the flow status in one passage is different to another. And for capturing the internal flow detail information, the $\kappa-\varepsilon$ turbulence model is not very suitable.

  • PDF

Study on Leading-phase Operation Capability of a 770 MW Jumbo Hydro-generator based on Stability Analysis and End-Region Heat Analysis

  • Fan, Zhen-nan;Zhou, Zhi-ting;Li, Jian-fu;Wen, Kun;Wang, Jun;Sun, Zhang;Wang, Tao;Yao, Bing
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.3
    • /
    • pp.1317-1325
    • /
    • 2018
  • A generator-grid coupling calculation model is established to study the leading-phase operational capability of a 770 MW jumbo hydro-generator in a Chinese ultra-mega hydropower station. The static and dynamic stability of the generator are analyzed and calculated to obtain stability limits under leading-phase operating conditions. Three-dimensional (3D) time-varying nonlinear moving electromagnetic and temperature field models of the generator end-region are also established and used to determine the magnetic field, loss, and temperature of the end-region under the leading-phase operating condition. The simulation results agree with data measured from the actual 770 MW hydro-generator. This paper provides reliable reference data for the leading-phase operation of a jumbo hydro-generator, which will help to improve in the design and manufacture of future hydro-generators.

The Influence Factors on the Performance of Regional Public Hospitals (지방의료원의 성과에 영향을 미치는 요인)

  • Lee, Hae Jong;Lee, Dong Won;Jeong, Ji Yun
    • Health Policy and Management
    • /
    • v.29 no.1
    • /
    • pp.27-39
    • /
    • 2019
  • Background: This study is designed to estimate the factors that affect the level of three different performance (publicity, efficiency, profitability) among regional public hospitals. Methods: The units of analysis are the regional 30 hospitals, which have the operating data during 22 years (from 1933 to 2014). The research method is used by fixed panel analysis. The publicity is measured by medicaid outpatient proportion and medicaid inpatient proportion. The efficiency is measured by two types of efficient score by DEA (data envelopment analysis). The profitability is measured by medical income to medical revenue and ROA (return on total asset). Results: At first, the increase of bed gives negative affect to the publicity but give positive effect to the efficiency and profitability. Because it means the increase of the region population, it gives more profitability compare to hospital with small number of beds. The more the operating period is the higher effect to the publicity and efficiency because of it's refutation. The debt ratio gives negative effect to publicity, but positive effect to profitability. It is the normal belief that there is inverse relationship between publicity and profitability. The turnover rate of bed gives the negative affect to the publicity, but positive affect to the efficiency and profitability. That give us the implication that type of the inpatient make different effect the hospital performance. The ratio of labor cost give negative effect to all kind of performance. That means that the higher labor cost don't mean the higher publicity and labor cost control is very important factors to hospital performance. So the region hospital have to focus the labor factors more to make higher performance. Conclusion: As the conclusion, the independent variables give similar effect to the efficiency and the profitability, but give inverse effect to the publicity. That means that if an region hospital want to make the more publicity, it loss the higher efficiency and profitability. Specially publicity is higher negative relation with the profitability.

40.8 MHz coherent scatter ionospheric radar observations of E- and F-region field aligned irregularities over Korea

  • Yang, Tae-Yong;Kwak, Young-Sil;Lee, Jae-Jin;Choi, Seong-Hwan;Hwang, Jung-A;Park, Young-Deuk
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.36 no.2
    • /
    • pp.81.1-81.1
    • /
    • 2011
  • The new coherent scatter ionospheric radar has been operating at Gyerong city ($36.18^{\circ}N$, $127.14^{\circ}E$, dip lat $26.7^{\circ}N$), South Korea. This VHF radar is consisted of 24 Yagi antennas having 5 elements and observes the E- and F-region field-aligned irregularities (FAIs) in a single frequency of 40.8 MHz with a peak power of 24 kW. We present the first results of the E- and F-region FAIs over Korea by using the new VHF coherent scatter ionospheric radar. The morphological and echo characteristics are studied in terms of their echo strength, Doppler velocity and also by spectral width values. From the continuous observations from December 2009, we found ionospheric E- and F-region FAIs appeared frequently. The most interesting and striking observations for E region are occurrence of daytime E-region irregularities and strong Quasi-Periodic (QP) echoes at nighttime. And for F region, strong post-sunset and pre-sunrise FAIs appeared frequently. The VHF radar observations over Korea are discussed in the light of current understanding of mid-latitude E- and F-region FAIs.

  • PDF

Ground-based Observations for the Upper Atmosphere at King Sejong Station, Antarctica

  • Jee, Geonhwa;Kim, Jeong-Han;Lee, Changsup;Kim, Yong Ha
    • Journal of Astronomy and Space Sciences
    • /
    • v.31 no.2
    • /
    • pp.169-176
    • /
    • 2014
  • Since the operation of the King Sejong Station (KSS) started in Antarctic Peninsula in 1989, there have been continuous efforts to perform the observation for the upper atmosphere. The observations during the initial period of the station include Fabry-Perot Interferometer (FPI) and Michelson Interferometer for the mesosphere and thermosphere, which are no longer in operation. In 2002, in collaboration with York University, Canada, the Spectral Airglow Temperature Imager (SATI) was installed to observe the temperature in the mesosphere and lower thermosphere (MLT) region and it has still been producing the mesopause temperature data until present. The observation was extended by installing the meteor radar in 2007 to observe the neutral winds and temperature in the MLT region during the day and night in collaboration with Chungnam National University. We also installed the all sky camera in 2008 to observe the wave structures in the MLT region. All these observations are utilized to study on the physical characteristics of the MLT region and also on the wave phenomena such as the tide and gravity wave in the upper atmosphere over KSS that is well known for the strong gravity wave activity. In this article, brief introductions for the currently operating instruments at KSS will be presented with their applications for the study of the upper atmosphere.