• Title/Summary/Keyword: Operating region

Search Result 861, Processing Time 0.024 seconds

Implementation of Fuzzy-Logic-Based Indirect Vector Control for Spindle Induction Motor in Field Weakening Region (약계자 영역에서 퍼지 추론을 인용한 스핀들 유도전동기 간접벡터제어)

  • Yoon J. M.;Yu J. S.;Won C. Y.;Choi C.;Lee S. H.
    • Proceedings of the KIPE Conference
    • /
    • 2004.07a
    • /
    • pp.303-307
    • /
    • 2004
  • This paper presents a new speed control scheme of the spindle induction motor (IM) using fuzzy-logic control in field weakening region. The implementation of the proposed FLC-based spindle IM are investigated and compared to those obtained from the conventional PI controller based drive system, we have confirmed good simulation and experimental results at different dynamic operating conditions such as sudden change in command speed, step change, etc.

  • PDF

Stress Estimation of a Drain Current in Sub-threshold regime of amorphous Si:H

  • Lee, Do-Young;Lee, Kyung-Ho
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2007.08b
    • /
    • pp.1172-1175
    • /
    • 2007
  • We have investigated the threshold voltage shifts(${\Delta}Vth$) and drain current level shift (${\Delta}Ids$) in subthreshold region of a-Si:H TFTs induced by DC Bias (Vgs and Vds) - Temperature stress (BTS) condition. We plotted the transfer curves and the ${\Delta}Vth$ contour maps as Vds-Vds stress bias and Temperature to examine the severe damage cases on TFTs. Also, by drawing out the time-dependent transfer curve (Ids-Vgs) in the region of $10^{-8}\;{\sim}\;10^{-13}$ (A) current level, we can estimate the failure time of TFTs in a operating condition.

  • PDF

Dynamic Strain Aging on the Leak-Before-Break Analysis in SA106 Gr.C Piping Steel

  • Kim, Jin-Weon;Kim, In-Sup
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1996.05c
    • /
    • pp.193-198
    • /
    • 1996
  • The effect of dynamic strain aging (DSA) on the leak-before-break (LBB) analysis was estimated through the evaluation of leakage-size-crack and flaw stability in SA106 Gr.C piping steel. Also. the results were represented as a form of "LBB allowable load window". In the DSA temperature region. the leakage-size-crack length was smaller than that at other temperatures and it increased with increasing tensile strain rate. In the results of flaw stability analysis. the lowest instability load appeared at the temperature corresponding to minimum J- R curve which was caused by DSA. The instability load near the plant operating temperature depended on the loading rate of J-R data. and decreased with increasing tensile strain rate. These are due to the strain hardening characteristic and strain rate sensitivity of DSA. In the "LBB allowable load window". LBB allowable region was the narrowest at the temperature and loading conditions where DSA occurs.

  • PDF

Application of DEA to Investigate Distinctive Regional Characteristics for Asia-Pacific Telco Management

  • Kustedjo, Ancilla Katherina;Han, Hyun-Soo
    • Journal of Information Technology Applications and Management
    • /
    • v.23 no.4
    • /
    • pp.83-100
    • /
    • 2016
  • In this paper, we present the DEA (Data Envelopment Analysis) application case study to investigate the regionally distinctive telco management characteristics of the Asia-Pacific countries. This study attempts to exploit the implications of DEA for the assessments of core process capabilities of telcos. Accordingly, we extract input variables of CAPEX (capital expenditure), operating expense, marketing expense, and number of employees, each to reflect the competitiveness of the core processes such as fixed asset utilization, operation & sales efficiency, and white collar productivity. In conjunction with the input variables, the output variables are chosen as EBITDA (Earnings Before Interest, Taxes, Depreciation and Amortization), ARPU (Average Revenue per User), and number of subscribers. The computational testing results, conducted with total 37 telcos of the 12 Asia-Pacific countries, are analyzed in various ways to understand the distinctive performance characteristics across the region. The managerial implication captured from this study provides useful insight for using DEA as the international telco management purpose.

A Rail-to-Rail OTA Using Equivalent MOSEETs without Cutoff Region Operating in Triode and Saturation Regions

  • Nishioka, Soushirou;Hyogo, Akira;Sekine, Keitaro
    • Proceedings of the IEEK Conference
    • /
    • 2002.07b
    • /
    • pp.1184-1187
    • /
    • 2002
  • In this paper, we propose a Rail-to-Rail OTA using equivalent MOSFETs without cutoff region, which operate in triode and saturation regions. The proposed circuit has a merit that its input range is not limited due to voltage drop of current mirrors. The simulation results of the proposed circuit are shown. From the simulation results, the linearity of the proposed circuit is improved when input voltage is from 2V to 3V.

  • PDF

Hot- Fire Injector Test for Determination of Combustion Stability Boundaries Using Model Chamber

  • Sohn Chae Hoon;Seol Woo-Seok;Shibanov Alexander A.;Pikalov Valery P.
    • Journal of Mechanical Science and Technology
    • /
    • v.19 no.9
    • /
    • pp.1821-1832
    • /
    • 2005
  • This study realizes the conceptual method to predict combustion instability in actual full-scale combustion chamber of rocket engines by experimental tests with model (sub-scale) chamber. The model chamber was designed based on the methodologies proposed in the previous work regarding geometrical dimensions and operating conditions, and hot-fire test procedures were followed to obtain stability boundaries. From the experimental tests, two instability regions are presented by the parameters of combustion-chamber pressure and mixture (oxidizer/fuel) ratio, which are customary for combustor designers. It is found that instability characteristics in the chamber with the adopted jet injectors can be explained by the correlation between the characteristic burning or mixing time and the characteristic acoustic time: In each instability region, dynamic behaviors of flames are investigated to verify the hydrodynamically-derived characteristic lengths of the jet injectors. Large-amplitude pressure oscillation observed in upper instability region is found to be generated by lifted-off flames.

Design of V-I Converter using Series Composite Transistor (직렬 복합 트랜지스터를 이용한 전압-전류 변환기 설계)

  • 김종민;유영규;이준호;박창선;김동용
    • Proceedings of the IEEK Conference
    • /
    • 1999.11a
    • /
    • pp.251-254
    • /
    • 1999
  • In this paper V-I(Voltage to Current) converter using the series composite transistor is presented. Due to the series composite transistor employs operating in the saturation region and triode region, the proposed circuit has wide input range at low voltage. The designed V-I converter has simulated by HSPICE using 0.6${\mu}{\textrm}{m}$ n-well CMOS process with a $\pm$2.5V supply voltage. Simulation results show that the THD can be 0.81% at 4 $V_{p-p}$ differential input voltage when frequency of input signal is 10MHz.z.

  • PDF

Transient Flow Characteristics of the Room Air Conditioner (룸에어컨 내부 유동의 과도현상에 대한 수치적 연구)

  • Seo, Hyeon-Seok;Kim, Jin-Baek;Kim, Youn-Jea
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2008.03b
    • /
    • pp.526-529
    • /
    • 2008
  • Air Conditioner has become a popular comfort providing device since two decades, whether in an office or home especially for warm and wet climate countries. The RAC (Room Air Conditioner) is widely used in various working spaces and residences. It composed of heat exchager, cross-flow fan, stabilizer, rearguider and blade of diffuser region, etc. In this study, numerical analyses based on the prediction of transient phenomena were carried out to investigate the flow characteristics in the RAC, including the impeller, the rearguider, the stabilizer and the blade of the diffuser region. Using a commercial code, FLUENT, the velocity, pressure and streamlines were obtained with unsteady, turbulent flow and no-slip condition. The angular velocities of impeller are located in the 900 rpm. Turbulent closure was achieved using a standard k-${\varepsilon}$ model. A moving reference frame (MRF) approach was adopted to simulate the flow field generated by impeller in the RAC. Results were graphically depicted with various geometrical configurations and operating conditions.

  • PDF

Formation of MILD Combustion using Co-flow MILD Combustor (동축류 마일드 연소기를 적용한 마일드 연소 형성 연구)

  • Lee, Pil Hyong;Hwang, Sang Soon
    • Journal of the Korean Society of Combustion
    • /
    • v.22 no.3
    • /
    • pp.8-16
    • /
    • 2017
  • MILD combustion was first developed to suppress thermal NOx formation in combustor for heating industrial furnaces. In this paper, the effect of co-flow MILD combustor geometry and operating conditions on the formation of MILD combustion was analyzed using 3 dimensional numerical simulation. The numerical simulations were carried out using ANSYS Fluent. The combustion and turbulence flow was modeled using the Eddy Dissipation Concept(EDC) model and realizable $k-{\varepsilon}$ model respectively. The results show that the high temperature region and average temperature decreased due to an increase in the air velocity and decrease the wall thickness of fuel nozzle. In particular, the MILD combustion flame was found to be stable with a combustion flame region at fuel velocity 10 m/s, air velocity 20 m/s, fuel nozzle thickness 1.0 mm, equivalence ratio 0.9, and outlet area ratio 40%.

Experimental Study of the Superheat and Control of the Refrigerant Flow-Rate in the Evaporator of a Multi-type Air-Conditioning System (멀티형 공조시스템의 증발기 과열도에 관한 실험적 연구 및 냉매유량 제어)

  • 김태섭;홍금식;손현철
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2000.10a
    • /
    • pp.221-221
    • /
    • 2000
  • The heat exchange part in a modern multi-type air-conditioning system employs multiple-pass heat exchangers. The heat-transfer performance of an each pass in such an exchanger depends strongly on the length of the two-phase region and the mass flow of the refrigerant. The total length and diameters of the pipes, the exit conditions, and the arrangement of each pass as well as the geometrical shape of the distributor at the branching sections are considered to be major factors affecting the heat-transfer performance. The refrigerant commonly used in these systems is HCFC-22. The two objectives of this paper are to investigate the characteristics of the refrigerant flow rate and the superheat in the evaporator of a multi-type air-conditioning system for a single or simultaneous operating conditions and to control the superheat and the refrigerant flow rate of the evaporator.

  • PDF