• 제목/요약/키워드: Operating power

검색결과 6,003건 처리시간 0.252초

반도체 공정장비 Gas Scrubber의 에너지 모니터링 시스템개발 (Development of an Energy MonItorIng System for Gas Scrubber)

  • 김선만;임익태;안강호
    • 반도체디스플레이기술학회지
    • /
    • 제10권2호
    • /
    • pp.13-17
    • /
    • 2011
  • We have developed a new energy-consuming monitoring system that has made it possible to measure the energy consumption of a gas scrubber, one of semiconductor processing equipments, and installed this system to the gas scrubber under operating at a manufacture site. Using this system, we have measured consumptions of electric power and processing gas consumed at standby to operating mode. In case of the gas scrubber, processing gas flows continuously into it at standby and operating mode. Therefore, if the electric power has been supplied, the processing gas can flows into the device for 24 hours. Moreover, at operating of gas scrubber, the amount of electricity consumption is 5 kWh. At Standby of gas scrubber, it spends 3kwh. It is certain that the energy consumption is greater at operating mode than at standby mode. The carbon emission rates from 24 hour gas scrubber operation are 236 $kgCO_2$/day of $N_2$, 57 $kgCO_2$/day of electric power and 0.001 $kgCO_2$/day of cooling water. Most of carbon is emitted from $N_2$ gas and electric power consumption.

라오스 남능강 유역 다중 저수지 시스템의 최적 수력발전 운영규정 곡선 개발 (Development of Multi-Reservoir System Operation Rule Curves for Hydropower Maximization in the Nam Ngum River Basin of Lao PDR)

  • 이현재;장웅철;이일주;이진희
    • 대한토목학회논문집
    • /
    • 제42권6호
    • /
    • pp.803-814
    • /
    • 2022
  • 라오스 정부는 증가할 것으로 예상되는 전기 수요량을 충족하기 위해, 남능강 유역 내에 기존 8개소의 발전소 외에도 발전소 댐을 지속적으로 개발하고 있거나 기존 발전소의 발전 설비용량을 증설하고 있다. 이에 따라 라오스 정부는 발전소를 효율적으로 운영하기 위해 기존 저수지 운영규정 곡선(reservoir operation rule curve)을 갱신할 필요성을 제기하였다. 본 연구는 이를 위해 범용적인 동적 계획법(Dynamic Programming:DP) 프로그램인 CSUDP를 활용하여 발전소에서 생산되는 연간 발전량을 극대화하기 위해 현재의 단독 운영체계 외에 연계 운영체계도 검토하였다. 이의 결과로부터 적절한 운영규정 곡선 형태(URC/LRC, MRC)를 추출하였고, 이를 HEC-ResSim 프로그램의 저수지 운영 세트의 운영기초 자료로 입력하여 연간 발전량을 모의하였다. 모의된 연간 발전량과 기존의 운영규정 곡선, 운영실적, 그리고 현장 운영자의 의견 등을 종합하여, 대상 발전소의 연간 발전량을 최대화하는 최적의 저수지 운영규정 곡선(reservoir operation rule curve)을 개발하였다. 이 경우, 저수지를 연계하여 운영하는 체계가 저수지 단독의 운영체계보다 연계에 따른 시너지 효과로 약 2.5 %의 발전량을 더 생산하는 것으로 모의 되었다.

Pattern Recognition of Monitored Waveforms from Power Supplies Feeding High-Speed Rail Systems

  • Gu, Wei;Zhang, Shuai;Yuan, Xiaodong;Chen, Bing;Bai, Jingjing
    • Journal of Electrical Engineering and Technology
    • /
    • 제11권1호
    • /
    • pp.55-64
    • /
    • 2016
  • The development of high-speed rail (HSR) has had a major impact on the power supply grid. Based on the monitored waveforms of HSR, a pattern recognition approach is proposed for the first time in this paper to identify the operating conditions. To reduce the data dimensions for monitored waveforms, the principal component analysis (PCA) algorithm was used to extract the characteristics and their waveforms from the monitored waveforms data. The dynamic time wrapping (DTW) algorithm was then used to identify the operating conditions of the HSR. Cases studies show that the proposed approach is effective and feasible, and that it is possible to identify the real-time operating conditions based on the monitored waveforms.

An Investigation of Characteristics of the Operating Modes of Two-Module Thyristor Controlled Series Compensator

  • Chung, Gyo-Bum
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1998년도 Proceedings ICPE 98 1998 International Conference on Power Electronics
    • /
    • pp.903-908
    • /
    • 1998
  • This paper aims at investigating the characteristics of the operating modes of two-module Thyristor Controlled Series Compensator (TCSC) in a power transmission system. The operating modes of two-module TCSC are defined, analyzed and compared to those of single-module TCSC are defined, analyzed and compared to those of single-module TCSC. The load flow program, the stability calculation program and Electro Magnetic Transient Program (EMTP) simulation of a TCSC power transmission system are developed for the performance evaluation of two-module TCSC as a power flow controller. In the process of the simulation study, the potential problem areas of the TCSC power transmission system are identified.

  • PDF

퍼지 로직 및 모델 예측 제어기 적용을 통한 초초임계압 화력발전소 부하 응답 최적화 운전 방법 설계 (Unit Response Optimizer mode Design of Ultra Super Critical Coal-Fired Power Plant based on Fuzzy logic & Model Predictive Controller)

  • 오기용;김호열
    • 전기학회논문지
    • /
    • 제57권12호
    • /
    • pp.2285-2290
    • /
    • 2008
  • Even though efficiency of coal-fired power plant is proportional to operating temperature, increasement of operating temperature is limited by a technological level of each power plant component. It is an alternative plan to increase operating pressure up to ultra super critical point for efficiency enhancement. It is difficult to control process of power plant in ultra super critical point because that point has highly nonlinear characteristics. In this paper, new control logic, Unit Response Optimizer Controller(URO Controller) which is based on Fuzzy logic and Model Predictive Controller, is introduced for better performance. Then its performance is tested and analyzed with design guideline.

통신교환기용 DC 전원시스템을 위한 에너지 절약형 지능제어기 (Intelligent Energy Saving Power System Controller for Telecom DC Power Plant)

  • 김일중;구세완;김택용;최주엽
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1996년도 추계학술대회 논문집 학회본부
    • /
    • pp.323-325
    • /
    • 1996
  • The design of Intelligent Energy Saving Power System Controller (IESPSC) for Telecom DC power plants is proposed and presented in this paper. From the past experience. rectifiers for Telecom DC power plants have been operated inefficiently at light loads. IESPSC offers "novel load sharing" approach based on the knowledge of each unit's efficiency of paralleled rectifiers. Neural networks is used for identifying each rectifier's efficiency characteristic curve corresponding to load currents, which is in turn utilized to produce a system efficiency close to the maximum under all operating conditions. In addition, by limiting the number of operating units to the minimum while maintaining high efficiency at the determined loads, a drastic savings in operating cost can be achieved.

  • PDF

매립가스 자원화를 위한 가스엔진 발전의 수익성에 관한 연구 (A Study on Profitability of Power Plant for Landfill Gas)

  • 김오우;이정일
    • 산학경영연구
    • /
    • 제19권2호
    • /
    • pp.69-94
    • /
    • 2006
  • 매립된 패기물의 분해과정에서 생성되는 부산물로서의 매립가스는 악취와 환경오염을 유발하는 유해한 가스로 여겨져 왔다. 그러나 발열량이 $5,000kcal/m^3$에 달하는 매립가스의 특성은 에너지원으로써의 활용가치가 탁월한데다 지구온난화의 주범으로 떠오르면서 그 회수 필요성이 더욱 강조되고 있어, 재생에너지로서의 매립가스를 대체에너지 자원으로 이용하려는 추세는 매우 고무적인 현상이라 하겠다. 현재 우리나라의 매립가스자원화 사업은 가스엔진을 이용한 전력생산이 대부분을 차지하고 있으며, 부분적으로 중질가스와 고질가스의 활용에도 관심을 보이고 있다. 가스발전기의 가동률과 전력단가의 변동을 고려하여 매립가스의 경제성을 분석해본 결과, 초기 투자비 회수와 지속적인 수익성 확보를 위해서는 최소한 10년 이상의 발전사업 운영 및 전력판매 단가의 현실화가 요구되고 있다.

  • PDF

Evaluation of the Aging Life of the Rubber Pad in Power Window Switch

  • Kang, Yong Kyu;Choi, Byung Ik;Woo, Chang Su;Kim, Wan Doo
    • Elastomers and Composites
    • /
    • 제54권4호
    • /
    • pp.351-358
    • /
    • 2019
  • To evaluate the aging of a rubber pad in power window switch which is the part of a vehicle, the accelerated thermal aging test of rubber pad material is performed. Finite element analysis was performed using the nonlinear material constants of the rubber pad to calculate the operating force, and the Arrhenius relationship was derived from the aging temperature and time. The aging test was performed at 150, 180, 210, or 240 ℃ for 1 to 60 days. When the operating force of the rubber pad is changed by 10% from the initial value, the service life is expected to be 113 years, which is much longer than the life of the vehicle. This indicates that the aging life of the rubber pad is sufficiently safe and the operating force of the rubber pad during the life of the vehicle (20 years) was decreased by approximately 8.4%. By examining the correlation between the shear elastic modulus and operating force calculated from finite element analysis under each aging test condition, the changes in the operating force of the rubber pad and the shear elastic modulus showed good linear relationship. The aging life could be predicted by the change in shear elastic modulus and a process for predicting the aging life of automotive power window switch rubber pad parts is described herein.

임계모드에서 동작하는 단일 전력단 고역률 방전등용 전자식 안정기에 관한 연구 (A Study on Single-Stage High-Power-Factor Electronic Ballast for Discharge Lamps Operating in Critical Conduction Mode)

  • 서철식;박재욱;심광열;김해준;원재선;김동희
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제54권12호
    • /
    • pp.601-608
    • /
    • 2005
  • This paper presents a novel single-stage high-power-factor electronic ballast for fluorescent lamps operating in critical conduction mode. The proposed topology is based on integration of boost converter as power factor corrector(PFC) and a half-bridge high frequency parallel resonant inverter into a single stage. The input stage of the boost converter is operating in critical conduction mode for positive and negative half cycle voltage respectively at line frequency(60Hz). So that a boost converter makes the line current follow naturally the sinusoidal line voltage waveform. The simulated and experimental results for 100W fluorescent lamps operating at 42kHz switching frequency and 220V line voltage have been obtained. This proposed inverter will be able to be practically used as a power supply in various fields as induction heating applications, fluorescent lamp and DC-DC converter etc.

Reactive Power and Soft-Switching Capability Analysis of Dual-Active-Bridge DC-DC Converters with Dual-Phase-Shift Control

  • Wen, Huiqing;Su, Bin
    • Journal of Power Electronics
    • /
    • 제15권1호
    • /
    • pp.18-30
    • /
    • 2015
  • This paper focuses on a systematical and in-depth analysis of the reactive power and soft-switching regions of Dual Active Bridge (DAB) converters with dual-phase-shift (DPS) control to achieve high efficiency in a wide operating range. The key features of the DPS operating modes are characterized and verified by analytical calculation and experimental tests. The mathematical expressions of the reactive power are derived and the reductions of the reactive power are illustrated with respect to a wide range of output power and voltage conversion ratios. The ZVS soft-switching boundary of the DPS is presented and one more leg with ZVS capability is achieved compared with the CPS control. With the selection of the optimal operating mode, the optimal phase-shift pair is determined by performance indices, which include the minimum peak or rms inductor current. All of the theoretical analysis and optimizations are verified by experimental tests. The experimental results with the DPS demonstrate the efficiency improvement for different load conditions and voltage conversion ratios.