• Title/Summary/Keyword: Operating facilities

Search Result 975, Processing Time 0.026 seconds

Residual Settlement Behavior in Soft Ground Improved by PBD during Operating Facilities (PBD공법이 적용된 연약지반에서 운용 중인 시설물의 잔류침하거동)

  • Kang, Gichun;Kim, Taehyung;Jeong, Choonggi
    • Journal of the Korean GEO-environmental Society
    • /
    • v.15 no.8
    • /
    • pp.13-21
    • /
    • 2014
  • The Plastic Board Drain is used to improve soft soils deposited in container terminal area at a port. This paper describes settlement behavior of soft ground in this area from PBD installation to the time of operating facilities. Previous researches focused on soil improvement effect of PBD, that is, the settlement occurred during ground improvement period. The residual settlement occurred during operating the facility is very important from the maintenance and management point of view. However, the study of this residual settlement has been rarely conducted. In this study, by analyzing the measured settlement data obtained from the container terminal area at the port, it was verified that the residual settlement induced during operating facilities occurred in a layer with PBD improvement. In addition, by comparison the settlement predicted by a numerical analysis with the settlement measured in the field, it was confirmed that the actual settlement is in the range of predicted settlement.

Study on the Improvement Process for the Food Waste Resource Facility (I) - Focus on Composting Facility of DDM Environmental Resource center - (음식물류 폐기물 자원화시설의 공정개선에 관한 연구(I) - DDM환경자원센터의 퇴비화시설 사례를 중심으로 -)

  • SHIN, Hyun-Gon
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.26 no.3
    • /
    • pp.15-22
    • /
    • 2018
  • This study refers to the composting of DDM Environmental Resource Center, which is operating abnormally in the food waste public-resource facilities that are operating nationwide, in accordance with the initial operating conditions. Similar process cases were investigated to examine issues concerning unusual composting facilities in DDM environmental resource centers and to analyse the causes of the issues. In addition, several improvement measures and alternatives for converting abnormal driving facilities into normal driving facilities may be proposed, and major abnormal driver provisions that are highlighted as issues during field application may be resolved.

A Study in the legal standards of healthcare facilities in Korea, China, and Japan (한국·중국·일본의 의료시설 법적기준과 그 변화 과정에 관한 연구)

  • Cho, Junyoung;Lei, Qingyun;Yang, Naewon
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.26 no.4
    • /
    • pp.39-47
    • /
    • 2020
  • Purpose: Korea, China, and Japan can be seen as a geopolitical community that has developed through various relationships in terms of history. However, nowadays, it seems that they are pursuing different societal goals resulting from the difference in political and social systems, demographic structures, and economic situations. The law provides the minimum standards for people's lives in the direction that the society pursues. Therefore, the aim of this study is to examine the architectural differences in medical facilities and their causes comparing the legal standards of medical facilities in Korea, China, and Japan. Methods: The subject of the study is Korea, China, and Japan's legal standards of facilities corresponding to the Korean medical service act; enforcement decree of medical service act; and enforcement rules of medical service act. The scope of the study is as follows: First, the facilities standards and the reason for the revision of the standards after the 1950s when the current system of each country was established are investigated and thus the changing trends of the facilities standards that each country has pursued are analyzed. Second, the range and level presented by the current facilities standards of each country are compared and the differences are analyzed. Finally, cases in which the differences in the legal facilities standards are reflected in the actual design are compared and the effect of the facilities standards of medical facilities on the architectural plan is identified. Results & Implications: Each country differs in the legal standards of facilities because of changes in demographic structure and experience of disease. Moreover, it is identified that differences in social operating systems, especially in the operating methods of medical facilities, affect the range and level enforced by the facility standards. When investigating and researching foreign standards of facilities and cases for foreign medical facilities, it is required that they should be analyzed in consideration of the social and cultural aspects of each country.

Quayside Container Crane Efficiency in the United States

  • Desrosiers, Robert A.
    • Journal of the Korean Institute of Navigation
    • /
    • v.22 no.3
    • /
    • pp.51-63
    • /
    • 1998
  • This paper presents the results of a study that looks into the different operating structures of terminals in the United States and attempts to find the type of terminal management scheme (All-Comers Common User Facilities, Programmed Common User Facilities, and Program-Tied User Facilities) that is most efficient with regard to crane usage. The paper uses gross and net crane moves per hour to develop an efficiency ratio that is then used to compare terminals. A total of thirty-one terminals were compared in an attempted to find the most efficient management scheme. While the hypothesis that Program-Tied User Facilities are the most efficient operating scheme was accepted, the sample was too small to provide conclusive results pertinent to the terminals in the United States.

  • PDF

Reasonable Operation Method for Electrical Safety Management Agency System (전기안전관리대행 제도의 합리적 운영 방안)

  • Kim, Doo-Hyun;Kim, Sung-Chul;Lee, Jong-Ho;Kim, Sun-Gu;Hwang, Kwang-Su;Kim, Sang-Chul
    • Journal of the Korean Society of Safety
    • /
    • v.27 no.1
    • /
    • pp.14-19
    • /
    • 2012
  • This study proposes to suggest a direction hereafter which is the most suitable operating system of electrical safety management agency for electrical facilities to enhance electrical safety considering our domestic conditions. It was designed to prevent electrical disasters which are increasing due to environmental changes in the electrical industry, and the diversification and complication of the electrical facilities. And the strategy of this research is based on conditions of safety management agency for the electrical facilities, with the analysis on conditions of electrical disasters, and with a questionnaire investigation for owner of electrical facilities, safety management agency. Results of this research are expected to be used to prevent electric fires and shocks effectively by reinforcing the electrical safety management agency of electrical facilities having danger of large-scaled accidents. It is expected to enhance the nation's competing power against foreign countries by reducing the human and physical loss, resulted from the development of reasonable operating system for electrical safety management agency.

Analysis of evacuation time for New publicly used establishments according to whether safety facilities, etc. are installed

  • Hong-Sang Lee;Ha-Sung, Kong
    • International Journal of Internet, Broadcasting and Communication
    • /
    • v.15 no.2
    • /
    • pp.49-59
    • /
    • 2023
  • In accordance with the revision of "Special act on the safety control of publicly used establishments", this study is aim to measure the change in evacuation time due to whether safety facilities, etc. are installed of a room escape cafe business and kids cafe business(hereinafter referred to as "New publicly used establishments"), which were added as new targets of the publicly used business from June 8, 2022. In the case of new publicly used establishments or publicly used establishments whose owners are changed after the revision of the relevant laws, safety facilities, etc. are installed and maintained under the "Special act on the safety control of publicly used establishments", but in the case of existing businesses that have been operating even before the revision of the law, the business continues without safety facilities, etc. installed because the revised law is not retroactively applied. The purpose of this study is to compare and analyze the change in evacuation time by measuring the evacuation time to operating before the revision of the law to simulate evacuation at existing new publicly used establishments without safety facilities, etc. and measure the evacuation time at new publicly used establishments with safety facilities after the revision of the law

A Study on Classification of Explosion Hazardous Area for Facilities using Lighter-than-Air Gases (공기보다 가벼운 가스 사용시설의 폭발위험장소 설정방안에 대한 연구)

  • Yim, Ji-Pyo;Chung, Chang-Bock
    • Journal of the Korean Society of Safety
    • /
    • v.29 no.2
    • /
    • pp.24-30
    • /
    • 2014
  • There have been controversies over whether explosion hazardous area(EHA) should be classified for facilities which use lighter-than-air gases such as city gas, hydrogen and ammonia. Two view points are confronting each other: an economic piont of view that these gases are lighter than air and disperse rapidly, hence do not form EHA upon release into the atmosphere, and a safety point of view that they are also inflammable gases, hence can form EHA although the extent is limited compared to heavy gases. But various standards such as KS, IEC, API, NFPA do not exclude light gases when classifying EHA and present examples of EHA for light gas facilities. This study calculates EHA using the hypothetical volume in the IEC code where the hole sizes required for the calculation were selected according to various nominal pipe sizes in such a way to conform to the EHA data in the API code and HSL. Then, 25 leakage scenarios were suggested for 5 different pipe sizes and 5 operating pressures that cover typical operating conditions of light gas facilities. The EHA for the minimum leakage scenario(25 mm pipe, 0.01MPa pressure) was found to correspond to a hypothetical volume larger than 0.1 $m^3$(medium-level ventilation). This confirms the validity of classifying EHA for facilities using lighter-than-air gases. Finally, a computer program called HACPL was developed for easy use by light gas facilities that classifies EHA according to operating pressures and pipe sizes.

Recognition of Employees in Long-term Care Facilities on the Operating Environment Changes According to Introduction of Long-term Care Insurance (노인장기요양보험제도 실시에 따른 노인요양시설 종사자들의 운영환경변화 인식)

  • Choi, Jee-Hye;Kim, Sun-Hee;Cho, Kyoung-Won
    • The Korean Journal of Health Service Management
    • /
    • v.5 no.3
    • /
    • pp.13-23
    • /
    • 2011
  • This paper investigated the operating environment for the representative of each agency and the facility workers on the basis of analytical result of recognition changes of the operating environment changes under the operating the long-term care insurance. It was described plans to take positive effect on the operating as follows. The first, on the result of regression analysis, the service administrative range takes the biggest effect on the general recognition of executing the long-term care insurance off and on. The affirmative recognition of the service administrative range had the general recognition on the system be positive effect. But the operator of facility asserts that the care manager's professionalism related quality of service be strengthened. The second, on the result of regression analysis, in the financial accounting administrative it is revealed the more positive recognition it is, the more positive effects it has. From the difference verification of an operation size from operation subject, the small operation size and personal facility recognize the long term care insurance positively. On the other side the facilities where the operation size is big recognize the system negatively. The long-term care facility should rearrange a support program newly and the government needs to promote the donation activity, because it is needed to reduce the financial burden of facilities.

Comparative Study on the Facilities for the Elderle Care (노인케어시설의 정책개발을 위한 국제비교연구)

  • 김기훈
    • Health Policy and Management
    • /
    • v.8 no.1
    • /
    • pp.203-230
    • /
    • 1998
  • This purposes of this study is to develope policies on the facilities for the elderly care in Korea. Methodology of this study adopts comparative analysis on the facilities for the elderly care in 6 countries which have experienced various problems on the elderly. These 6 countries are Japan, Sweden, America, Australian, England and Germany. Major issues for comparative analysis are the standard of care facilities, residence condition, finance of facilities establishment and expense, operating system, management, and the law and administrative structure about the facilities for the elderly care. The elderly people need various kinds of welfare services such as medical care facilities, nursing home facilities, home care facilities etc.. Thus the public policies for the aging population nations are compose of income maintenance program, health and medical care services and social welfare services. The policies of facilities for elderly care are very important since these policies include the characteristics of income maintenance, me\ulcorner미 care program and welfare program. This study willsupply basic data for the development of facilities for the elderly care in Korea, especially conceming the system and institutional device of the facilities.

  • PDF

Investigation on Ventilation Mmethod and Recognition of Users in Healthcare Facilities of KOREA (국내 의료기관의 환기설비 운영실태 및 인식 조사)

  • Jo, Seongmin;Sung, Minki
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.24 no.2
    • /
    • pp.7-14
    • /
    • 2018
  • Purpose: The outbreak of Middle East Respiratory Syndrome(MERS) in KOREA has brought up the demands for ventilation guideline and regulations for healthcare facilities since most of the infection was spreaded inside healthcare facility. Currently KOREA has no ventilation guideline or regulations covering entire section of healthcare facility. The purpose of this study is to investigate current ventilation methods in KOREA healthcare facilities to in future, propose ventilation guideline. Methods: Research of foreign counties ventilation guideline and regulation for healthcare facilities were conducted for reference. Field investigation with survey of 21 healthcare were conducted to identify the ventilation system and operating methods. Additionally survey for healthcare workers were conducted to observe the recognition related to ventilation system in healthcare facility. Results: The result showed that most of foreign countries ventilation guideline and regulation suggests similar items to reduce the spread of infection and maintain good indoor air quality. The investigation results indicated that fixed guideline for ventilation in healthcare facility were required due to different ventilation operating methods. Survey result of healthcare workers has told us that ventilation guideline and regulation is needed to prevent further infection. Implications: Absence of ventilation guideline and regulations for healthcare facility in KOREA is an urgent issue.