• Title/Summary/Keyword: Operating environment

Search Result 2,912, Processing Time 0.031 seconds

Heavy Metal Removal Efficiency in Accordance with Changes in Acid Concentrations in a Micro-nano Bubble Soil Washing System and Pickling Process (마이크로나노버블 토양세척시스템 및 산세척 복합공정의 산 농도변화에 따른 중금속 제거효율에 관한 연구)

  • Jung, Jin-Hee;Choi, Ho-Eun;Jung, Byung-Gil;Sung, Nak-Chang;Yi, Gi-Chul;Choi, Young-Ik
    • Journal of Environmental Science International
    • /
    • v.26 no.1
    • /
    • pp.23-28
    • /
    • 2017
  • This study was aimed at determining the changes in heavy metal removal efficiency at different acid concentrations in a micro-nanobubble soil washing system and pickling process that is used to dispose of heavy metals. For this purpose, the initial and final heavy metal concentrations were measured to calculate the heavy metal removal efficiency 5, 10, 20, 30, 60, and 120 min into the experiment. Soil contaminated by heavy metals and extracted from 0~15 cm below the surface of a vehicle junkyard in the city of U was used in the experiment. The extracted soil was air-dried for 24 h, after which a No. 10 (2 mm) was used as a filter to remove large particles and other substances from the soil as well as to even out the samples. As for the operating conditions, the air inflow rate in the micro-nano bubble soil washing system was fixed at 2 L/min,; with the concentration of hydrogen peroxide being adjusted to 5%, 10%, or 15%. The treatment lasted 120 min. The results showed that when the concentration of hydrogen peroxide was 5%, the efficiency of Zn removal was 27.4%, whereas those of Ni and Pb were 28.7% and 22.8%, respectively. When the concentration of hydrogen peroxide was 10%, the efficiency of Zn removal was 38.7%, whereas those of Ni and Pb were 42.6% and 28.6%, respectively. When the concentration of hydrogen peroxide was 15%, the efficiency of Zn removal was 49.7%, whereas those of Ni and Pb were 57.1% and 42.6%, respectively. Therefore, the efficiency of removal of all three heavy metals was the highest when the hydrogen peroxide concentration was 15%.

Evaluation of the KASI Detector Performance Test System Using an Andor iKon M CCD Camera

  • Yu, Young Sam;Kim, Jinsol;Park, Chan;Jeong, Woong-Seob;Kim, Minjin;Choi, Seonghwan;Park, Sung-Joon
    • Journal of Astronomy and Space Sciences
    • /
    • v.35 no.3
    • /
    • pp.201-210
    • /
    • 2018
  • The characterization of detectors installed in space- and ground-based instruments is important to evaluate the system performance. We report the development of a detector performance test system for astronomical applications using the Andor iKon M CCD camera. The performance test system consists of a light source, monochromator, integrating sphere, and power meters. We adopted the Czerny-Tuner monochromator with three ruled gratings and one mirror, which covers a spectral range of 200-9,000 nm with a spectral resolution of ~1 nm in the visible region. Various detector characteristics, such as the quantum efficiency, sensitivity, and noise, can be measured in wide wavelength ranges from the visible to mid-infrared regions. We evaluated the Korea Astronomy and Space Science Institute (KASI) detector performance test system by using the performance verification of the Andor iKon-M CCD camera. The test procedure includes measurements of the conversion gain ($2.86e^-/ADU$), full well capacity ($130K\;e^-$), nonlinearity, and pixel defects. We also estimated the read noise, dark current, and quantum efficiency as a function of the temperature. The lowest measured read noise is $12e^-$. The dark current at 223 K was determined to be $7e^-/s/pix$ and its doubling temperature is $5.3^{\circ}C{\pm}0.2^{\circ}C$ at an activation energy of 0.6 eV. The maximum quantum efficiency at 223 K was estimated to be $93%{\pm}2%$. We proved that the quantum efficiency is sensitive to the operating temperature. It varies up to 5 % in the visible region, while the variation increases to 30 % in the near-infrared region. Based on the comparison of our results with the test report by the vendor, we conclude that our performance test results are consistent with those from the vendor considering the test environment. We also confirmed that the KASI detector performance test system is reliable and our measurement method and analysis are accurate.

Optimization of the Unducted Auxiliary Ventilation for Large-Opening Underground Limestone Mines (대단면 지하 석회석 광산내 무풍관 국부통기 최적화 연구)

  • Nguyen, Van Duc;Lee, Chang Woo
    • Tunnel and Underground Space
    • /
    • v.29 no.6
    • /
    • pp.480-507
    • /
    • 2019
  • This paper aims at optimizing the auxiliary ventilation system in large-opening limestone mines with unducted fans. An extensive CFD and also site study were carried out for optimization at the blind entries. The fan location, operating mode, and layout are the parameters for optimization. Since the jet stream discharged from the auxiliary fan is flowing faster than 15 m/s in most of the cases, the stream collides with floor, sides or roof and even with the jet stream generated from the other fan placed upstream. Then, it is likely to lose a large portion of its inertial force and then its ventilation efficiency drops considerably. Therefore, the optimal fan installation interval is defined in this study as an interval that maximizes the uninterrupted flowing distance of the jet stream, while the cross-sectional installation location can be optimized to minimize the energy loss due to possible collision with the entry sides. Consequently, the optimization of the fan location will improve ventilation efficiency and subsequently the energy cost. A number of different three-dimensional computational domains representing a full-scale underground space were developed for the CFD study. The velocity profiles and the CO concentrations were studied to design and optimize the auxiliary ventilation system without duct and at the same time mine site experiments were carried out for comparison purposes. The ultimate goal is to optimize the auxiliary ventilation system without tubing to provide a reliable, low-cost and efficient solution to maintain the clean and safe work environment in local large-opening underground limestone mines.

A Computerized Database and Statistical Analysis System for Radiotherapy (방사선 치료 환자 자료처리 및 통계의 전산화에 관한 연구)

  • Ha Sung Whan;Kim Il Han;Kang Wee Saing;Park Charn Il
    • Radiation Oncology Journal
    • /
    • v.8 no.1
    • /
    • pp.103-109
    • /
    • 1990
  • A computerized system for database of radiotherapy Patient and for its application was developed in 1987 and has been utilized till now. A radiotherapy Planning computer (Eclipse S-140) operated under AOS (Advanced Operating System) is the main processing unit of the system which was programmed with Fortran-5. Records of 30,000 patients can be separately registered and data of 5 courses of radiotherapy delivered to one patient can be separately registered but structurally linked together. The same environment is allowed for 60 follow-up data. Our system's utility is very convenient to use and provides simple or conditional list of records or items, periodic statistics concerning many parameters and survival or complication analysis of stored database or data manually put in. Structure, operation and several retrieval formats by data processings are reported.

  • PDF

Isolation of Functional Fatty Acid in Cosolvent Induced SFE Process (공용매가 첨가된 초임계유체 추출공정에서 기능성 지방산의 추출)

  • Lee, Seung Bum;Park, Kyung Ai;Hong, In Kwon
    • Applied Chemistry for Engineering
    • /
    • v.10 no.3
    • /
    • pp.438-444
    • /
    • 1999
  • The natural full-fat rice bran is reported to contain 8.4 to 14.7 wt % Lipids, but the amount and composition of bran depend on the type of rice, quality of paddy, pretreatments to paddy such as parboiling, type of milling system employed, and the degree of polishing. These lipids are usually mixtures of several class fatty acids containing palmitic acid, linolenic acid, linoleic acid, oleic acid, stearic acid, tocopherol, squalene, etc. In this study the oil rich essential fatty acid (EFA) including squalene was extracted from the domestic brown rice bran using supercritical fluid extraction (SFE) and cosolvent induced SFE process, respectively. And the extracts were analyzed with GC-MSD. The extracted amount of rice bran oil was dependent upon the operating pressure and temperature, and the fatty acid composition of oil was varied with the reduced density (${\rho}_{\gamma}$) of supercritical carbon dioxide. About 70~80% of rice bran oil was extracted in 4hrs. The cosolvent induced SFE process shortened the total extraction time, extracted greater amount of oil than SFE process. Especially squalene which was not found in solvent extract phase was identified in SFE and cosolvent induced SFE process.

  • PDF

Estimation of demersal fish biomass using hydroacoustic and catch data in the marine ranching area (MRA) of Jeju (제주바다목장해역에서 수중음향과 어획데이터를 활용한 저층 어류의 현존량 추정)

  • Lee, Jae-Bong;Oh, Taeg-Yun;Yeon, In-Ja;Kim, Byung-Yeob;Shin, Hyeon-Ok;Hwang, Bo-Kyu;Lee, Kyung-Hoon;Lee, Yoo-Won
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.48 no.2
    • /
    • pp.128-136
    • /
    • 2012
  • Hybrid surveys using hydroacoustic and fish sampling gears such as trammel net, trap were conducted to investigate total biomass, distribution and dominant fish species of the demersal fishes in the marine ranching area (MRA) of Jeju. Four surveys were carried out in June, August, October and November using 38kHz quantitative echo sounder. Catch data using trammel net and trap were used to calculate biomass and to examine dominant fish species. Fish schools were mainly detected in the waters of 20 meters below and around Chagwido waters. By the result of fishing experiments, fish species living in MRA of Jeju were about 40 species, dominant fish species of a detectable fish such as Family Sparidae and Family Monacanthidae etc. were identified 59.4~68.8% of total biomass. Based on the hydroacoustic data, fish length-weight function and target strength information, mean density of the demersal fish estimated were as follows; 0.88g/$m^2$ on June, 1.12g/$m^2$ on August, 1.35g/$m^2$ on October and 1.18g/$m^2$ on November. An estimated average biomass in MRA of Jeju was founded 20.5 tons in 2007, 20.6 tons in 2008, 23.0 tons in 2009, 25.9 tons in 2010. The results showed that biomass of MRA is getting increased slowly. Therefore the hybrid survey method using hydroacoustic and fish sampling gears is assured an effective biomass survey in the waters of mixed species.

웹을 활용한 과학영재 심화 학습 지원 체제 구축

  • Jhun, Young-Seok
    • Journal of Gifted/Talented Education
    • /
    • v.12 no.4
    • /
    • pp.72-107
    • /
    • 2002
  • In order to satisfy the gifted students' learning desire and maximize the effectiveness of their learning, we constructed the system which would provide them with supplementary activities based on the Internet boards. At the very beginning, we investigated the personalities of the gifted and their classroom environment which they prefer through studying the related references and asking questionnaires. And then we discussed how to improve the lectures, decided to make the basic structures of the web-based supporting system, and designed some teaching strategies for the gifted. which are named 'GIFTED'. Now the web-based supporting system, which are composed of several boards, was established and is being operated now. Each subject has its own boards. The boards of each subject basically consist of Notice, Learning-materials, Q&A, Homework, Recommended Sites. The results we've got from operating our system are following: Teachers and students were generally satisfied with the system while students wanted more materials. Students and teachers had a positive attitude that the site boards of Learning-materials and Homework are being actively used, while the numbers of contents uploaded in Q&A and Recommended site boards are small and they are regarded as being unimportant to the students and teachers.

Experimental and CFD Study on the Exhaust Efficiency of a Smoke Control Fan in Blind Entry Development Sites (맹갱도 굴진 작업공간내 방재팬의 화재연 배기효율에 관한 현장실험 및 CFD 연구)

  • Nguyen, Vanduc;Kim, Dooyoung;Hur, Wonho;Lee, Changwoo
    • Tunnel and Underground Space
    • /
    • v.28 no.1
    • /
    • pp.38-58
    • /
    • 2018
  • The ventilation system plays a crucial role in underground mine safety. The main objective of the ventilation system is to supply sufficient air to dilute the contaminated air at working places and consequently provide tenable environment during the normal operation, while it also should be capable of controlling the fire propagation and facilitate rescue conditions in case of fire in mines. In this study, a smoke control fan was developed for the auxiliary ventilation as well as the fire smoke exhaust. It works as a free-standing auxiliary fan without tubing to dilute or exhaust the contaminated air from the working places. At the same time, it can be employed to extract the fire smoke. This paper aims to examine the smoke control efficiency of the fan when combined with the current ventilation system in mines. A series of the site experiments and numerical simulations were made to evaluate the fan performance in blind entry development sites. The tracer gas method with SF6 was applied to investigate the contaminant behavior at the study sites. The results of the site study at a large-opening limestone mine were compared with the CFD analysis results with respect to the airflow pattern and the gas concentration. This study shows that in blind development entry, the most polluted and risky place, the smoke fan can exhaust toxic gases or fire smoke effectively if it is properly combined with an additional common auxiliary fan. The venturi effect for smoke exhaust from the blind entry was also observed by the numerical analysis. The overall smoke control efficiency was found to be dependent on the fan location and operating method.

Sliding Wear Properties of Graphite as Sealing Materials for Cut off Hot Gas (고온차단 기밀용 그라파이트의 고온 미끄럼마모 특성 평가)

  • Kim, YeonWook;Kim, JaeHoon;Yang, HoYeong;Park, SungHan;Lee, HwanKyu;Kim, BumKeun;Lee, SeungBum;Kwak, JaeSu
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.37 no.11
    • /
    • pp.1349-1354
    • /
    • 2013
  • Sealing structure to prevent flowing hot gas into the driving device, located between the driving shaft and the liner of On-Off valve for controlling the hot gas flow path was studied. Wear occurs due to the constant movement of the driving shaft controlled by actuator on graphite as the sealing material. In this paper, the dynamic wear behavior in high temperature of graphite(HK-6) to be used as sealing material was evaluated. Reciprocating wear test was carried out for the graphite(HK-6) to the relative motion between shaft materials(W-25Re). The results of friction coefficient and specific wear rate according to contact load, sliding speed at room temperature and $485^{\circ}C$ considering the actual operating environment were evaluated. Through the SEM analysis of the worn surface, third body as lubricant films were observed and lubricant effect of third body was considered.

Development of liquid target for beam-target neutron source & two-channel prototype ITER vacuum ultraviolet spectrometer

  • Ahn, B.N.;Lee, Y.M.;Dang, J.J.;Hwang, Y.S.;Seon, C.R.;Lee, H.G.;Biel, W.;Barnsley, R.;Kim, D.E.;Kim, J.G.
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2011.02a
    • /
    • pp.421-422
    • /
    • 2011
  • The first part is about development of a liquid target for a neutron source, which is designed to overcome many of the limitations of traditional beam-target neutron generators by utilizing a liquid target neutron source. One of the most critical aspects of the beam-target neutron generator is the target integrity under the beam exposure. A liquid target can be a good solution to overcome damage to the target such as target erosion and depletion of hydrogen isotopes in the active layer, especially for the one operating at high neutron fluxes with no need for water cooling. There is no inherent target lifetime for the liquid target neutron generator when used with continuous refreshment of the target surface exposed to the energetic beam. In this work, liquid target containing hydrogen has been developed and tested in vacuum environment. Potentially, liquid targets could allow a point neutron source whose spatial extension is on the order of 1 to $10{\mu}m$. And the second is about the vacuum ultraviolet (VUV) spectrometer which is designed as a five-channel spectral system for ITER main plasma measurement. To develop and verify the design, a two-channel prototype system was fabricated with No. 3 (14.4 nm~31.8 nm) and No. 4 (29.0 nm~60.0 nm) among the five channels. For test of the prototype system, a hollow cathode lamp is used as a light source. The system is composed of a collimating mirror to collect the light from source to slit, and two holographic diffraction gratings with toroidal geometry to diffract and also to collimate the light from the common slit to detectors. The two gratings are positioned at different optical distances and heights as designed. To study the appropriate detector for ITER VUV system, two different electronic detectors of the back-illuminated charge coupled device and the micro-channel plate electron multiplier were installed and the performance has been investigated and compared in the same experimental conditions. The overall system performance was verified by measuring the spectrums.

  • PDF