• Title/Summary/Keyword: Operating Tunnel

Search Result 223, Processing Time 0.026 seconds

Development of a Control and Virtual Realty Visual System for the Tilting Train Simulator (틸팅 차량용 시뮬레이터 적용을 위한 통제 및 가상현실 영상 시스템 개발)

  • Song Young-Soo;Han Seong-Ho;Kim Jung-Seok
    • Journal of the Korean Society for Railway
    • /
    • v.8 no.4
    • /
    • pp.330-336
    • /
    • 2005
  • This paper presents a development of the control and the virtual reality visual system for a tilting train simulator. The user of the tilting train simulator is able to set up the environmental and operating conditions through the user interface provided by the control system. In the control system, an arbitrary track which has user-defined curve radius, length and direction can be generated. The virtual reality visual system provides an artificial environment that is composed of several facilities such as station, platform, track, bridge, tunnel and signaling system. In order to maximize the reality, all of the 3D modeling were based on the real photographs taken in the Jungang line. A dome screen with 1600mm diameter was used to maximize the view angle. The hemispherical screen can ensure the view angle of the 170 degrees of vertical direction and 135 degrees of lateral direction.

A Study on the Performance Analysis of Automotive Air Conditioning System (자동차용 에어컨 시스템의 성능해석에 관한 연구)

  • 이대웅;유성연
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.14 no.4
    • /
    • pp.304-314
    • /
    • 2002
  • Performance analysis of the automotive air-conditioning system is conducted by using computer simulation, and performance tests are carried out by using the climate wind tunnel in order to verify simulation. Evaporator and condenser were modeled by using empirical correlation which was obtained from calorimeter data, and compressor was modeled by using map based method. The steady state thermodynamic conditions of refrigerant satisfying mass and energy balance were assumed in the simulation program for automotive airconditioning system. The system performance was analyzed by finite difference method until differential air enthalpy between evaporator inlet and outlet becomes converged. Simulation results are in good agreement with experimental results at most operating conditions. Variation of discharge temperature and pressure of compressor, outlet temperature of evaporator, cooling capacity, and COP were investigated in term of air volume flow rate for evaporator, compressor capacity, compressor speed, superheat of thermostatic expansion valve, and diameter of suction line.

Development of Microtunneling machine for Unmanned Cable-Tunnel (무인통신구(${\Phi}1000mm$)건설용 마이크로터널링 장비 개발)

  • Park Jung-Kwon;Seo Myung-Woo;Kim Jung-Yun
    • 한국정보통신설비학회:학술대회논문집
    • /
    • 2003.08a
    • /
    • pp.376-378
    • /
    • 2003
  • 본 논문에서는 2002년도에 KT에서 개발한 내경 1,000mm의 무인통신구를 건설 할 수 있는 마이크로터널링 장비에 대해 소개하고자 한다. 개발된 장비는 3D 기법을 이용한 최첨단 기법을 통하여 개발되었으며, 소형 굴진기의 취약점인 장애물 돌파능력을 보완하기 위하여 막장으로 진입이 가능한 구조로 되어있다. 따라서 굴진 중 장애물에 직면했을 경우 막장을 통하여 장애물을 효과적으로 제거할 수 있으며, 이 막장 진입통로를 이용하여 면판의 비트와 롤러커터를 교체할 수 있으므로 장거리 굴진이 가능하다. 그리고 굴진작업 시 필요한 원압잭과 후방설비인 Desander, 송 배니펌프등의 주변설비를 Operating Room에서 통합관리 할 수 있는 터널링 관리시스템을 개발하여 적용함으로써 보다. 효율적인 굴진관리를 수행할 수 있는 특징을 갖고 있다. 이렇게 개발된 장비와 시스템은 시험 시공을 통해 그 성능을 확인하였으며, 여기서 그 개발 과정 및 시험 시공 결과에 대해 기술하고자 한다.

  • PDF

A study on the High Integrated 1TC SONOS Flash Memory (고집적화된 1TC SONOS 플래시 메모리에 관한 연구)

  • 김주연;이상배;한태현;안호명;서광열
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.07a
    • /
    • pp.26-31
    • /
    • 2002
  • To realize a high integrated Flash memory utilizing SONOS memory devices, the NOR type 1TC(one Transistor Cell) SONOS Flash arrays are fabricated and characterized. This SONOS Flash arrays with common source lines are designed and fabricated by conventional 0.35$\mu\textrm{m}$ CMOS process. The thickness of ONO for memory cell is tunnel oxide of 34${\AA}$, nitride of 73${\AA}$ and blocking oxide of 34${\AA}$. To investigate operating characteristics, CHEI(Channel Hot Electron Injection) method and Bit line erase method are selected as the write operation and the erase method, respectively. The disturbance characteristics according to the write/erase/read cycling are also examined. The degradation characteristics are investigated and then the reliability of SONOS flash memory is guaranteed.

  • PDF

A Suggestion of indoor CO2 concentration prediction equation by operating KTX flap in Tunnel Sections (터널구간 운행시 KTX 플랩 작동에 따른 CO2 농도 예측식 제안)

  • So, Jin-Sub;Yoo, Seong-Yeon;Kim, Ick-Hee
    • Proceedings of the KSR Conference
    • /
    • 2010.06a
    • /
    • pp.2052-2057
    • /
    • 2010
  • In December 2006, the Ministry of Environment in Korea established the "Indoor Air Quality Management Guidelines in Public Transportation." As the items of the guideline, $CO_2$(Carbon dioxide) and PM10(Particulate matter). Therefore, the air quality inside the train is supposed to be ruled by this guideline. This study calculated the increase or decrease rate of the $CO_2$ concentration by using the data measured in accordance with flap operation. In case of flap close or open, the calculated $CO_2$ concentration variation was 6.32ppm/min. The $CO_2$ concentration prediction equation was derived from the general equation and the actual measured value are compared with the predicted $CO_2$ concentration suggested during the KyungBu high speed railway construction. The predicted value show good agreement with the measured data.

  • PDF

Case Study on Analysis the Problem and Improvement of Subway Maintenance Monitoring (지하철 유지관리 계측의 문제점 분석 및 개선방안 연구)

  • 우종태;김홍석
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2000.03c
    • /
    • pp.93-104
    • /
    • 2000
  • By means of analyzing the problems in monitoring plan, design, installation, operation based on maintenance monitoring system installed in subway tunnel section, the methods of improvement were proposed for applying to subway monitoring maintenance effectively in future. The choice of the better monitoring system, the operating method of monitoring system, the confidence and continuity of maintenance monitoring, the performance of responsible monitoring supervision in the phase of the planning of monitoring and design were proposed. The problem and developed plan in the different monitoring systems, the calibration and correction of monitoring system, the analysis for the results and plan for maintenance in the phase of installation of monitoring system and operation were also proposed.

  • PDF

A Study on Response Time Index and Operating Time for Fusible Link Sprinkler Head (용융형 스프링클러 헤드의 응답시간 지수 및 작동시간에 관한 연구)

  • 이병곤;태순호
    • Journal of the Korean Society of Safety
    • /
    • v.6 no.4
    • /
    • pp.34-44
    • /
    • 1991
  • In this study, the general solution of heat balance equation including conductive heat loss were suggested and were determined the constants with the results of experiment in hot tunnel in order to derive the general equation for the response time and to investigate the response time index which represent the characteristics of response of sprinkler head in actual fires. Two types of test were considered, the plunge test, in which the air temperature is represented by a step function, and the ramp test, in which the air temperature increases at a constant rate. As a result, simple equations were derived, which can be predicted the response time for the ramp type fire with the rate of temperature rise and gas velocity, for the plunge type fire with temperature and gas velocity. Also other useful data, such as the effective temperature, time constant, response time index and conduction parameter were obtained.

  • PDF

Investigation of Separated Injection of Air and Argon in Segmented Constrictor Type Arc Heaters (세그먼트 아크히터 내부에서 공기와 아르곤 기체의 혼합 현상에 대한 연구)

  • Lee, Jeong-Il;Jeong, Ga-Ram;Kim, Kyu-Hong
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2008.03b
    • /
    • pp.197-200
    • /
    • 2008
  • The existing computer code to solve the air flow in a segmented constrictor-type arc-heated wind tunnel named ARCFLO4 is improved to accept an air-argon mixture as the working gas and to consider the separated injection of air and argon. The new version of the code is used to calculate the flows in the Aerodynamic Heating Facility of NASA Ames Research Center where argon concentration is relatively high. The calculation shows that argon tends to increase the diameter of the arc-column, increase ionization fraction, decrease thermal efficiency of the arc-heater, and push the ratio of the centerline-to-average enthalpy toward unity. The calculated operating characteristics of the arc-heater agree well with the experimental data.

  • PDF

Ghost Junction Method for Flow Network System Analyses (유동망 시스템 해석을 위한 유령 정션 기법)

  • Hong, Seok-Woo;Kim, Chong-Am
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2008.03b
    • /
    • pp.626-629
    • /
    • 2008
  • Numerical predictions on flow phenomena in pipe network systems have been considered as playing an important role in both designing and operating various facilities of piping or duct systems, such as water supply, tunnel or mine ventilation, hydraulic systems of automobile or aircraft, and etc. Traditionally, coupling conditions between junction and connected branches are assumed to satisfy conservation law of mass and to share an equal pressure at junction node. However, the conventional methodology cannot reflect momentum interactions between pipes sufficiently. Thus, a new finite volume junction treatment is proposed both to reflect the interchanges of linear momentums between neighbor branches at junction and to include the effect of wall at junction in present work.

  • PDF

Operational Vibration Experiment and Analysis of a Small Vertical-Axis Wind Turbine Considering the Effect of Tower Stiffness (타워강성 효과를 고려한 소형 수직축 풍력발전기 운전 진동실험 및 해석)

  • Choo, Heon-Ho;Sim, Jae-Park;Ryu, Gyeong-Joong;Kim, Dong-Hyun;Kim, Bong-Yung
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2011.10a
    • /
    • pp.602-606
    • /
    • 2011
  • In this study, operational vibration experiment and analysis have been conducted for the 4-blade small vertical-axis wind turbine (VAWT) including the effect of tower elastic behavior. Computational structural dynamics analysis method is applied to obtain Campbell diagram for the VAWT with elastic tower. An open type wind-tunnel is used to change and keep the wind velocity during the ground test. Equivalent reduced elastic tower is supported to the VAWT so that the elastic stiffness effect of the tower can be reflected to the present vibration experiment. Various excitation sources with aerodynamic forces are considered and the dominant operating vibration phenomena are physically investigated in detail.

  • PDF