• Title/Summary/Keyword: Operating Temperature

Search Result 3,679, Processing Time 0.031 seconds

Simulation of the Characteristics of High-Performance Absorption Cycles (고성능 흡수냉동 사이클의 특성 시뮬레이션)

  • 윤정인;오후규;이용화
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.19 no.1
    • /
    • pp.231-239
    • /
    • 1995
  • This paper describes a computer simulation of the triple effect, water-lithium bromide absorption cooling cycles. The performance of the absorption systems is investigated through cycle simulation to obtain the system characteristics with the cooling water inlet temperature, the working solution concentrations, the ratio of the amount of the weak solution to the high, middle and low temperature generators, and the temperature difference of each solution heat exchanger. The efficiency of different cycles has been studied and the simulation results show that higher coefficient of performance could be obtained for the parallel cycle of constant solution distribution rate. As a result of this analysis, the optimum designs and operating conditions were determined based on the operating conditions and coefficient of performance.

Simulation of Rice Circulating Concurrent-flow Dryer (벼의 순환병류건조기(循環竝流乾操機)의 시뮬레이션)

  • Keum, D.H.;Lee, W.S.
    • Journal of Biosystems Engineering
    • /
    • v.13 no.3
    • /
    • pp.59-70
    • /
    • 1988
  • A computer simulation model for rice circulating concurrent-flow dryer was developed and verified by conduction a series of pilot-scale experiment. The effects of design parameter and operating conditions on dryer performance were analyzed by using simulation. The results indicated that the developed model was found suitable for analyzing operating characteristics. The other results from simulation also showed that; 1) an increse in the initial moisture content resulted in an increase in the drying rate and a reduction in the grain temperature and total energy requirements. 2) an increase in the drying air temperature resulted in an increase in the drying rate and grain temperature. 3) an increase in air flow rate resulted in an radical increase in drying rate, fan power requirements and total energy requirements but an radical decrease in final head rice yield. 4) an increase in the bed depth resulted in an increase in fan power requirements and a lowering of the final head rice yield.

  • PDF

Utilization as External Carbon Source of TVFAs Fermentation with Sludge (슬러지를 이용한 유기산 발효공정의 외부 탄소원으로 활용)

  • 김영규;김인배;김민호
    • Journal of Environmental Health Sciences
    • /
    • v.27 no.4
    • /
    • pp.79-83
    • /
    • 2001
  • The sludge wastes fermentation process reactors were operated to produce the VFAs(volatile fatty acids) as supplemental carbon sources and to determine the optimum operating conditions. The experiment was carried out by varied mixture ration of 400:0 350:30 300:100 200:200 and operating temperature 2$0^{\circ}C$ 3$0^{\circ}C$ and 4$0^{\circ}C$ The results were as follows: Higher VFAs production rate observed at higher mixed ratio of primary sludge. When the mixed ratio of primary sludge and return sludge were 400:0 350:50 300:100 200:200 respectively. VFAs production are were 829.6mg/l 944.2 mg/l 597.9mg/ml an d441.6 mg/l , respectively. the yield of VFAs increased with temperature, but decreased with initial TSS concentration Because fermented sludge has relatively low nitrogen and phosphorus and relatively high VFAs it can be used as a substitute for external carbon in biological nutrient removal process.

  • PDF

Effect of Deposition Parameters on MgO Thin Films on Si(100) Substrates by Reactive RF Magnetron Sputtering (Reactive RF 마그네트론 스퍼터링법으로 Si(100) 기판에 MgO박막 제조시 증착변수의 영향)

  • 이영준;백성기
    • Journal of the Korean Ceramic Society
    • /
    • v.31 no.6
    • /
    • pp.643-650
    • /
    • 1994
  • Highly [100]-oriented MgO thin films were deposited on Si(100) single crystal substrates by reactive RF magnetron sputtering. The effects of substrate temperature, gas pressure, RF input powder, and gas composition on the characteristics of MgO thin films were studied. The higher substrate temperature and the lower operating pressure were, the better crystallinity of the deposited MgO thin films were. The influences of the RF input power and oxygen to argon ratio were very complex. The physical characteristics of the films changed dramatically with deposition conditions. Highly smooth and epitaxial MgO films were obtained at the deposition conditions as follows; subatrate temperature, $600^{\circ}C$; operating pressure, 10 mtorr; RF input power density, 2 W/$\textrm{cm}^2$; the percentage of oxygen, 10%.

  • PDF

Growth and characterization of ZnS thin films by Hot Wall Method (Hot Wall 법에 의한 ZnS 박막의 제작과 기초적 물성연구)

  • Heo, Sung-Gon;Lee, Sang-Tae
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.05b
    • /
    • pp.108-111
    • /
    • 2000
  • The Zns thin films were deposited on non-alkali glass substrate by the Hot Wall method. The thin films grown at various evaporation cell and substrate temperature were characterized by spectrophotometer and X-ray diffraction to investigate the optical and structural characteristics. The deposition rates were increased with increasing the cell temperature, and were decreased with increasing substrate. The optical characteristics of thin films depends on the deposition rates. The band gap energies measured at room temperature with 3.4~3.5eV are smaller than the theoretical value of 3.54eV. All ZnS thin films are oriented in (111) of the principal direction of a zincblende structure.

  • PDF

A Development of the electronic controlled vaporizer for low flow anesthesia (저유량 마취를 위한 전자제어식 기화기 개발)

  • Oh, Yeong-Taek;Park, Jae-Hoon;Chang, In-Bae
    • Journal of Industrial Technology
    • /
    • v.29 no.B
    • /
    • pp.107-113
    • /
    • 2009
  • For the environmental safety of the operating room and patient healthcare, the closed type rebreathing system is widely adopted. In order to reduce the anesthesia gas during surgery, the mixing ratio of anesthesia gas with breathing air should be precisely controlled. Generally, the breathing air passes through the vaporizer to mix the anesthesia gas, but there is a difficulty in controlling the mixing ratio precisely. In this paper, the stand-alone style vaporizer is designed and the operating characteristics are investigated. The vaporizer measures the temperature and pressure in the vaporizing chamber and chamber temperature is precisely controlled by proportional controlled heater. Exact quantity of anesthesia media is feeded by PID controlled peristaltic pump and vaporized gas is mixed with breathing air flow by PWM controlled solenoid valve. The experimental result shows that the vaporizer has an excellent command following performances that it can be applied to the low flow anesthesia system.

  • PDF

A Study on the Characteristic of NOx Emissions by IMO Operating Modes in a Four Stroke Marine Power Generation Diesel Engine (선박 발전용 4행정 디젤엔진의 IMO 운전모드에 따른 NOx 배출특성에 관한 연구)

  • 김현규;김규보;전충환;장영준
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.28 no.3
    • /
    • pp.457-465
    • /
    • 2004
  • Environmental protection on the ocean has been interested and nowadays the International Maritime Organization(IMO) has advanced on the prevention of air pollution from ships. This study presents the performance and the emission characteristics of 4 stroke marine diesel engines for generation application in D2 cycle(IMO mode). The effects of important operating parameters, such as intake air pressure. intake air temperature and maximum combustion pressure on NOx emissions were also described. Emissions measurement and calculation are processed according to IMO Technical Code. The results show that the maximum combustion pressure by fuel injection timing control and intake air temperature has strong influence on NOx emission production. But NOx emission is not affected by intake air pressure and exhaust gas back pressure.

Operating Characteristics of Internal Heat Exchanger for $CO_2$ Geothermal Heat Pump in the Heating Mode (난방모드 시 $CO_2$ 지열히트펌프의 내부열교환기에 대한 운전특성)

  • Kim, Jae-Duck;Lee, Sang-Jae;Kim, Seon-Chang;Kim, Young-Lyoul
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.1226-1231
    • /
    • 2009
  • This paper presents operating characteristics of internal heat exchanger(IHX) for $CO_2$ geothermal heat pump in the heating mode. Mass flow rate of $CO_2$, inlet temperatures of $CO_2$ at high and low pressure side were selected as main effect factors by using fractional factorial DOE(Design of Experiments). And RSM(Response Surface Method) was used in optimization phase. The results show that heat transfer rate of IHX increases when either inlet temperature of low pressure side decreases or inlet temperature of high pressure side increases. Effectiveness of IHX increases with increasing of inlet temperature of either high pressure side or low pressure side. Finally, performance contour map was provided over the operation ranges of the main design factors.

  • PDF

Study of Partial Discharge Influence on AC Breakdown Strength of Laminated Ploypropylene Paper(PPLP) at Liquid Nitrogen (액체 질소에서의 반합성지 AC 파괴 강도에 미치는 부분 방전의 영향)

  • 안드레프;김수연;이인호;김도운;신두성;김상현
    • Progress in Superconductivity and Cryogenics
    • /
    • v.4 no.1
    • /
    • pp.105-109
    • /
    • 2002
  • The short-term AC breakdown strength of laminated polypropylene insulating Paper (PPLP) has been studied for cold dielectric of high temperature superconductivity power cables. The design and operating conditions of the electrode system for studying of short-term breakdown strength of one-layer and multi-layer PPLP samples are discussed in liquid nitrogen(LN2) state. The influence of various operating factors (geometry and dimension of electrodes, speed of tested voltage, thickness of test sample) on the value of short-term AC breakdown strength at cryogenic temperature has been established.

Stress Analysis and Degradation Mechanism of the Drive Control system for a Railway carriage (철도차량 추진제어장치의 스트레스 분석 및 열화 메커니즘)

  • Kim, Ki-Joon;Wang, Jong-Bae;Choi, Young-Chan
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.10a
    • /
    • pp.21-24
    • /
    • 2000
  • Traction motors driven by several type inverters have been subjected to increasing demands for higher operating temperature, more demands for duty cycles, higher starting current, frequent voltage transients and finally severe environmental exposure. For applications to inverter duty, traction motors needs a special insulation system, which has characteristics of increased bond strength, lower operating temperature and higher turn-to-tum insulation. Also it needs major contributors to insulation life and reliability of motors, which more considered by temperature, voltage, frequency, rise time, pulse configuration, wire thickness and insulation materials. In this paper, to evaluate of reliability and expected life, it is analyzed the several stresses and their degradation mechanism on insulation system of AC traction motor.

  • PDF