• 제목/요약/키워드: Operating Rate

검색결과 3,327건 처리시간 0.284초

냉동시스템의 운전조건에 따른 열교환기 내장형 어큐뮬레이터의 성능 특성 (Performance Characteristics of Accumulator Heat Exchangers with Operating Conditions of a Refrigeration System)

  • 강훈;박차식;전종욱;김용찬
    • 설비공학논문집
    • /
    • 제18권12호
    • /
    • pp.984-991
    • /
    • 2006
  • The applications of multi air-conditioners into multiplex and high-rise buildings have been increased by replacing central air-conditioning systems. The pipe length and altitude difference between the indoor and outdoor units can be increased based on installation conditions, which may increase the possibility of flash gas generation at the expansion device inlet. The flash gas generation causes rapid reduction of refrigerant flow rate passing through the expansion device, yielding lower system efficiency. Accumulator heat exchangers have been widely used in multi air-conditioners in order to minimize flash gas generation and obtain system reliability. However, the studies on the heat transfer characteristics and pressure drops of accumulator heat exchangers are very limited in open literature. In this study, the heat transfer rates and pressure drops of accumulator heat exchangers were measured with refrigerant flow rate and operating conditions by using R-22. The heat transfer rate increased with the increase of refrigerant flow rate, while subcooling decreased. The heat transfer rate enhanced with the reduction of inlet superheat and subcooling due to the increased temperature difference between the accumulator and inner heat exchanger.

양방향 컨버터의 커패시터 위치에 따른 고장률 분석 (Analysis of failure rate according to capacitor position of bidirectional converter)

  • 김예린;강필순
    • 전기전자학회논문지
    • /
    • 제23권1호
    • /
    • pp.261-265
    • /
    • 2019
  • 기존 양방향 컨버터와 출력 커패시터를 추진용 배터리 쪽으로 이동시킨 양방향 컨버터의 고장률 변화를 분석한다. 두 컨버터의 회로 구조적 동일성과 차이점을 분석하여 커패시터 위치 변경으로 동작전압이 저감됨을 확인한다. 전압스트레스 인자와 동작온도에 따른 커패시터 부품 고장률을 구하고 양방향 컨버터의 고장나무에 적용하여 컨버터 전체 고장률을 구한다. 동작온도와 커패시턴스 값에 따른 고장률과 평균고장시간을 비교 분석하여 설계 변경으로 인한 장 단점을 분석한다.

한국 정유산업의 학습곡선과 생산성에 관한 연구 (A Study on the Learning Curve and Productivity)

  • 이종철;강규철
    • 산업경영시스템학회지
    • /
    • 제20권43호
    • /
    • pp.175-195
    • /
    • 1997
  • The learning curve has an important effect the growth of corporation. But, in Korea, the study and inference on the learning rate of each industry are unprepared, and so, Korean industires have difficult in productivity and cost. At this point, this study infers the learning rate of the oil industries and investigates the productivity and growth of them. In conclusion, this study presents the direction of the oil industries' development. With the intention of this objects, this study seizes the status which is concerned the total quantity, the operating rate, the plant capacity, the indicators concerning productivity, the investment of R & D and the scales, and then, infers and verifies the relevancy in connection with the learning rate. In the oil industry, the average rate of learning is 65.96% from 1982 to 1994 which the total quantity and the average operation time are used to infer the rate. To observe the low rate within a same period of time, this study takes the consequences that the learning rate is almost indentical with them each year. This steady state is caused by a difference between the employee and the decision maker about the acquirement and assimiliated of technology. When the high-quality technologies posses the environment to applicate in the scene of labor with them, this technology applies to the productivities. As the learning rate increases, the productivity has more effectiveness. The result of analysis about the effectiveness of the learning rate follows that the R & D unfoldes to exist and does not contribute to the growth of the oil industry. To analyze the variables of the growth, such as the learning rate, the investement of R & D, the operating rate and the gross value added to property, plant and equipment, the model is established and examined. The business strategy in the oil industry must be developed to achive the internal growth as well as the external.

  • PDF

회전원판공정과 화학침전공정 조합을 이용한 유기물과 질소*인의 동시제거 (Integrated System of RBC-lime Precipiatation for Simultaneous Removal of Organics and Nutrients)

  • 박종안;허준무;손부순
    • 한국환경보건학회지
    • /
    • 제24권1호
    • /
    • pp.132-140
    • /
    • 1998
  • 회전원판공정(rotating biological contactorRBC)과 화학적 처리공정을 결합한 처리시스템을 이용하여 도시하수내 포함된 유기물과 영양염류를 제거할 경우에 수리학적 부하 (hydraulic loading)와 처리수 반송율 (recirculation rate)의 시스템 처리효율에 미치는 영향을 알아보고자 하였다. 각각의 수리학적 부하 0.031, 0.0535 및 0.076 $m^3/m^2/d에서 반송율을 100%, 200%, 300%로 변화시켰고, 질산화에 필요한 알카리도의 보충 및 화학적 처리를 위하여 lime(CaCO$_3$)을 가하여 유입수의 pH를 10.4-11.0으로 유지시켰다. 실험결과 수리학적 부하 0.0535 $m^3/m^2/d에서 BOD, COD의 제거효율이 가장 높게 나타났으며, 질산화 효율 및 질소 제거효율에서는 수리학작 부하 0.035 $m^3/m^2/d, 반송율 300%에서 가장 높았으며, 반송율별에서는 수리학적 부하를 고려할 때 300% 반송하는 것이 가장 높은 유기물 제거효율을 보였다. 반송율과 수리학적 부하를 증가시킬 경우에 발생되는 슬러지내 유기물 함량은 점점 증가하였고, 수리학적 부하 0.076 $m^3/m^2/d, 반송율 300%일 경우에는 유기물 함량이 47%로 매우 높았다. 이는 부하증가에 따른 미생물 성장의 증가와 더불어 수리학적 부하 증가에 따른 전단력의 증가가 영향을 미쳤기 때문이다. 인을 제거하기 위하여 pH를 10.4-11.0으로 유지시킨 경우에 인을 90%이상 제거할 수 있었으며, 유출수내 평균 SS농도는 40 mg/l를 상회하였다.

  • PDF

현장 굴진자료 분석에 의한 토압식 쉴드 TBM의 운전조건과 굴진속도 연구 (A Study on Advance Rate under the Operating Conditions of EPB Shield TBM Based on TBM Operation Data)

  • 안만선;임광수;김경주
    • 대한토목학회논문집
    • /
    • 제31권6D호
    • /
    • pp.839-848
    • /
    • 2011
  • TBM(Tunnel Boring Machine) 터널은 굴진 도중 장비의 교체나 개조 등은 불가능하기 때문에 굴진 종료 시까지 투입된 장비로 굴진하여야만 한다. 특히 토압식 쉴드TBM은 막장관찰이 어려우므로 굴진 중에 수집된 자료를 분석하여 지반상태의 변화를 예측하고 이를 시공에 반영하여야한다. 지금까지의 TBM에 대한 연구는 굴착 대상이 되는 지반의 특성에 따른 장비선정 및 굴진속도 예측모델 개발이 주로 이루어져왔다. 그러나 굴착의 주체가 되는 TBM 장비의 굴진자료에 의한 지반상태의 추정 및 운전방법의 개선에 초점을 맞춘 연구는 그리 많이 수행되지 않았다. 본 연구는 토압식 쉴드TBM 시공 사례에서 얻은 굴진자료를 활용하여 투입된 장비의 운전조건에 따른 굴진속도의 변화와 최적 운전조건에 대해 알아보았다. 본 연구의 결과를 요약하면 다음과 같다. 첫째, 커터헤드의 회전속도와 총추력이 굴진속도에 가장 큰 영향을 주며 둘째, 적정한 굴진속도를 위해서는 최적 회전속도를 유지하면서 총추력을 조정하는 것이 좋으며 셋째, 총추력의 증가 추세에 따라 지반조건의 변화에 대한 예측이 가능하여 이에 따라 적절한 운전조건의 변경을 결정할 수 있다.

식물세포의 관류배양을 위한 초음파 분리기의 개발

  • 구영한;조규헌
    • 한국생물공학회:학술대회논문집
    • /
    • 한국생물공학회 2000년도 추계학술발표대회 및 bio-venture fair
    • /
    • pp.402-404
    • /
    • 2000
  • In this study, we have developed an ultrasonic separation system for plant cells and its operating conditions in terms of voltage, flow rate and concentration were examined. For plant cell, the operation of ultrasonic separator highly depended on concentration of cells. Holding capacity highly depended on flow rate in chamber. Optimum voltage was 30V in high density culture

  • PDF

사립대학병원의 원가행태 (Cost Behavior of Private University Hospital in Korea)

  • 최황규;황인경
    • 한국병원경영학회지
    • /
    • 제11권3호
    • /
    • pp.73-93
    • /
    • 2006
  • This study aims at providing necessary informations for management decision-making to the hospital manager, such as ratios of fixed and variable cost to total operating expense, and variable cost ratio to operating revenues, and determinant factors affecting cost behavior. A study model and related hypotheses were established, data were collected from 41 private university hospitals for the 6years from 1998 to 2003, and regression analyses were performed to test the hypotheses. The results of the analyses and conclusions are as follows; First, labor cost and administration cost within the same number of beds have not only fixed quality of the cost, but variable quality of that. Also, the ratio of the variable costs to operating revenue of the metropolitan was estimated 76.9% and that of other area hospitals was 80.1%. Second, the major factors affecting the increase rate of the operating expense were the increase rates of the number of inpatients, the number of employee, and the number of hospital operating bed. This result implies that maintaining a optimal hospital bed size and efficient operation of the beds are important strategic factors of hospital management.

  • PDF

과급을 이용한 저온 디젤 연소의 운전영역 확장 및 연료소비율 저감 (Expansion of Operating Range and Reduction of BSFC in Low Temperature Diesel Combustion with Boosting)

  • 심의준;한상욱;장진영;박정서;배충식
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2008년도 추계학술대회B
    • /
    • pp.3013-3018
    • /
    • 2008
  • Supercharging system was adopted to investigate the influence of boost pressure on operating range, brake specific fuel consumption (BSFC) and exhaust emissions by using a supercharger at low temperature diesel combustion (LTC) condition in a 5-cylinder 2.7 L direct injection diesel engine. The experimental parameters such as injection quantity, injection timing, injection pressure and exhaust gas recirculation (EGR) rate were varied to find maximum operating range. The result showed that operating range with boost was expanded up to 41.9% compared to naturally aspirated LTC condition due to increased mixing intensity. The boosted LTC engine showed low BSFC value and dramatically reduced soot emission under all operating range compared with high speed direct injection (HSDI) mode. Finally, this paper presents the boosted LTC map of emission and the strategy of improved engine operating range.

  • PDF

호텔의 건축적 속성이 운영 수익에 주는 영향에 관한 연구 - 서울지역 관광호텔을 중심으로 - (A Study on the Influence of Hotel's Architectural Attributes on Operating Revenue - Focused on Tourist Hotel in Seoul -)

  • 김현광;황희준
    • 대한건축학회논문집:계획계
    • /
    • 제34권8호
    • /
    • pp.43-50
    • /
    • 2018
  • The purpose of this study is to analyze the effect of architectural attributes on operating revenue by concentrating on the facility side and to investigate how much individual architectural factors can affect operating revenue. The time range of this study is limited to 2015, and the spatial range is limited to a tourist hotel in Seoul that can be easily surveyed and verified. The analysis method is to confirm the significance and influence of each attribute through regression analysis. According to the results, The room part such as number of rooms or area showed a relatively low correlation with "revenue per available room (Rev.PAR)" than "average daily rate (ADR)", but showed a high correlation with non - architectural attributes such as auxiliary facilities and chain. This shows that factors that influence the operating profit of hotel are not the part of the room but the other factors such as the auxiliary facilities work more. In addition, the presence of spa and the number of auxiliary facilities in the hotel have a positive effect on the operating profit of the hotel due to the non - architectural attributes. This is expected to provide a new direction for future research in studying hotel facilities.

가변속 스크롤 압축기의 운전조건의 변화에 따른 성능 해석 (Performance Analysis on the Variable Speed Scroll Compressor with Operating Conditions)

  • 박홍희;박윤철;김용찬
    • 설비공학논문집
    • /
    • 제12권7호
    • /
    • pp.649-658
    • /
    • 2000
  • Thermodynamic modeling of low-pressure scroll compressor was developed by combining continuity and energy conservation equation. Suction gas heating was considered using energy balance inside the low pressure shell. Pressure, temperature and mass of refrigerant-22 as a function of orbiting angle were calculated by solving the governing equations using fourth order Rung-Kutta scheme. Motor efficiency was taken by experiments with a variation of frequency. The developed model was applied to the analysis of an inverter driven scroll compressor with a variation of frequency, pressure ratio and operating conditions. The model was verified with the experimental results at the same operating conditions. The developed model was adequate to predict performance of the inverter driven scroll compressor as a function of operating conditions. Calculated parameters from the model were discharge temperature, mass flow rate, power input, COP, and thermodynamic properties with respect to orbiting angle. To enhance the performance of a scroll compressor, it is essential to diminish leakage at low frequency level and improve the mechanical efficiency at high frequency level.

  • PDF