• 제목/요약/키워드: Operating Rate

검색결과 3,315건 처리시간 0.035초

Membrane distillation of power plant cooling tower blowdown water

  • Ince, Elif;Uslu, Yasin Abdullah
    • Membrane and Water Treatment
    • /
    • 제10권5호
    • /
    • pp.321-330
    • /
    • 2019
  • The objective of this study was to examine the recovery of the power plant cooling tower blowdown water (CTBD) by membrane distillation. The experiments were carried out using a flat plate poly vinylidene fluoride (PVDF) membrane with a pore diameter of $0.22{\mu}m$ by a direct contact membrane distillation unit (DCMD). The effects of operating parameters such as transmembrane temperature difference (${\Delta}T$), circulation rate and operating time on permeate flux and membrane fouling have been investigated. The results indicated that permeate flux increased with increasing ${\Delta}T$ and circulation rate. Whereas maximum permeate flux was determined as $47.4L/m^2{\cdot}h$ at ${\Delta}T$ of $50^{\circ}C$ for all short term experiments, minimum permeate flux was determined as $7.7L/m^2{\cdot}h$ at ${\Delta}T$ of $20^{\circ}C$. While $40^{\circ}C$ was determined as the optimum ${\Delta}T$ in long term experiments. Inorganic and non-volatile substances caused fouling in the membranes.

Analysis of thermal energy efficiency for hollow fiber membranes in direct contact membrane distillation

  • Park, Youngkyu;Lee, Sangho
    • Environmental Engineering Research
    • /
    • 제24권2호
    • /
    • pp.347-353
    • /
    • 2019
  • Although membrane distillation (MD) has great promise for desalination of saline water sources, it is crucial to improve its thermal efficiency to reduce the operating cost. Accordingly, this study intended to examine the thermal energy efficiency of MD modules in a pilot scale system. Two different modules of hollow fiber membranes were compared in direct contact MD mode. One of them was made of polypropylene with the effective membrane area of $2.6m^2$ and the other was made of polyvinylidene fluoride with the effective membrane area of $7.6m^2$. The influence of operation parameters, including the temperatures of feed and distillate, feed flow rate, and distillate flow rate on the flux, recovery, and performance ratio (PR), was investigated. Results showed that the two MD membranes showed different flux and PR values even under similar conditions. Moreover, both flow rate and temperature difference between feed and distillate significantly affect the PR values. These results suggest that the operating conditions for MD should be determined by considering the module properties.

펌프의 저 유량 운전특성에 관한 실험적 연구 (An Experimental Study on the Pump Operating Characteristics with Low Flow Operation)

  • 오광석;신필권;박종호;심우건;조두연
    • 소음진동
    • /
    • 제9권1호
    • /
    • pp.85-96
    • /
    • 1999
  • For ASME Code pumps in nuclear power plants, inservice test is required to assess the operational readiness in accordance with ASME code and related regulations. The objective of this study therefore, is to develop the technical background of the degradation of pump performances and conditions due to low flow rate operation. In addition. the detection techniques of pump operating conditions are to be developed to enhance the safety and economy of nuclear power plants. A test loop consisted of pump, motor. water tank, flow rate measurements and piping system with flow control devices was established for this study. Two typical pumps, 1-stage volute pump and 3-stage turbine pump, were selected and the test was performed upon two major point of views ; i.e., pump discharge pressure pulsations analysis and pump vibration spectrum analysis. From the test results, it is concluded that (1) the pump vibration affected by the natural frequency of operating pump is significant in the low frequency zone (around 1 Hz) : the vibration amplitude. especially. is an important factor during low flow rate operation. and shall be monitored to ensure that it is within the limit of ASME OM code Part 6, (2) the vibration frequency and pump discharge pressure are affected by vane pass frequency and running speed, (3) the wave phenomena due to the compressiblity of water is anticipated during low flow rate operation. and the pump system shall be designed to prevent it and. finally, (4) the technical background of the degradation of pump performances and conditions due to low flow rate operation is provided.

  • PDF

Numerical Simulation and PIV Measurement on the Internal Flow in a Centrifugal Mini Pump at Low Flow Rate Conditions

  • Yuan, Hui-Jing;Shao, Jie;Cao, Guang-Jun;Liu, Shu-Hong;Wu, Yu-Lin
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2008년 영문 학술대회
    • /
    • pp.775-780
    • /
    • 2008
  • This paper reports on the internal flow of a centrifugal mini pump working at the low flow rate operating conditions. The RNG $\kappa-\varepsilon$ turbulence model was employed to simulate the three-dimensional turbulent flow in the pump. To examine and certify the simulation results, a transparent acrylic centrifugal mini pump model which is suitable for PIV measurement has been developed. The tongue region and the passages region between blades were investigated using PIV. In order to eliminate the effect of refraction on the area closed to the wall and increase the measurement accuracy, the fluorescent particles were scatted into the working fluid with the tracing particles. It is found from the calculation and PIV measurement results that there is a large area of recirculation flow near the tongue at low flow rate operating conditions. The computationally predicted water head using the $\kappa-\varepsilon$ turbulence model at low flow rate operating conditions are in very good agreement with the experimentally measured water head and the mean velocity distributions at investigation area obtained by PIV and calculation showed a satisfactory agreement as well. Meanwhile, the results of PIV measurements show that the flow status in one passage is different to another. And for capturing the internal flow detail information, the $\kappa-\varepsilon$ turbulence model is not very suitable.

  • PDF

Perioperative Nursing Data Set(PNDS)를 이용한 수술실 간호중재 분석 (Identification of Nursing Interventions in the Operating Room using the Perioperative Nursing Data Set(PNDS))

  • 김경희;조복희
    • 기본간호학회지
    • /
    • 제10권3호
    • /
    • pp.361-370
    • /
    • 2003
  • Purpose: This study was done to identify nursing interventions performed by operating room nurses using the Perioperative Nursing Data Set (PNDS). Method: The data were collected from 88 operating room nurses, from August 1 to October 25, 2002 using the PNDS developed by the Association of Operating Room Nurses and translated into Korean. Nurses working in 2 university hospitals in Gwang-ju and 2 general hospitals in Seoul. Data were analyzed using the SPSS program. Result: There were 15 of 127 nursing interventions which the operating room nurses indicated were important and which they performed at least once a day. Conclusion: The operating room nurses consider interventions to prevent physical injury and patient centered care to be very important, but the performance rate for patient centered care was low. It shows that there is a need in education courses for patient centered care to be more strongly emphasized.

  • PDF

공기분급식 미분쇄기의 운전조건이 미세분말의 크기에 미치는 영향 (Effects of Operating Conditions of an Air-Classifier Mill on the Particle Size of Fine Powder)

  • 신응수;김기성;김용욱
    • 한국생산제조학회지
    • /
    • 제25권6호
    • /
    • pp.426-433
    • /
    • 2016
  • This paper investigates the effects of operating conditions of an air classifier mill (ACM) on the particle sizes of PVC and rice hull. Based on the Box-Behnken matrix, the pulverization experiments were performed considering three operating factors: the air flow rate, the classifier speed and the mill speed. The response surface methodology was applied to identify the effects of the operating factors on the particle size. Results show that the particle sizes are governed by the linear variations of the operating factors. As less air is supplied and the mill rotates more slowly, the powder of both PVC and rice hull becomes finer. Furthermore, the classifier speed has a significant effect on the PVC powder but almost no effect on the rice hull powder. Thus, it is found that strong interactions exist between the material characteristics of a particle and the operating conditions of the ACM.

Multi-zone 모델링을 통한 온도성층화와 농도성층화가 존재하는 DME HCCI 엔진의 운전영역에 관한 수치해석연구 (Comparison of DME HCCI Operating Ranges for the Thermal Stratification and Fuel Stratification based on a Multi-zone Modeling)

  • 정동원;임옥택
    • 한국자동차공학회논문집
    • /
    • 제19권2호
    • /
    • pp.35-41
    • /
    • 2011
  • This work investigates the potential of in-cylinder thermal stratification and fuel stratification for extending the operating ranges in HCCI engines, and the coupling between thermal stratification and fuel stratification. Computational results areemployed. The computations were conducted using both a custom multi-zone version and the standard single-zone version of the Senkin application of the CHEMKINII kinetics rate code, and kinetic mechanism for di-methyl ether (DME). This study shows that the potential of thermal stratification and fuels stratification for extending the high-load operating limit by a staged combustion event with reduced pressure-rise rates is very large. It was also found that those stratification offers good potential to extend low-load limit by a same mechanism in high-load. However, a combination of thermal stratification and fuel stratification is not more effective than above stratification techniques for extending the operating ranges showing similar results of fuel stratification. Sufficient condition for combustion (enough temperature for) turns misfire in low-load limit to operate engines, which also leads to knock in high-load limit abruptly due to the too high temperature with high. DME shows a potential for maximizing effect of stratification to lower pressure-rise rate due to the characteristics of low-temperature heat release.

활성슬러지 하수처리시설 운영 및 유지관리를 위한 시스템다이내믹스 모델의 모의에 관한 연구 (Simulations of a System Dynamics Model for Operations and Maintenance of Activated-Sludge Wastewater Treatment Plants)

  • 박수완;김봉재;전환돈;김인철
    • 한국물환경학회지
    • /
    • 제22권5호
    • /
    • pp.905-912
    • /
    • 2006
  • In this paper, simulation methods of the system dynamics model developed by Das et al. (1997) for activated-sludge wastewater treatment plants are illustrated in an attempt to determine the operating rules and the policies related to capacity expansion of an activated-sludge wastewater treatment plant. For existing conditions, the analyses were performed by varying activated-sludge return rate to observe changes in effluent water quality and treatment efficiency. The effluent water quality is also analyzed for various average daily inflow conditions and activated-sludge return rates. As a result, without expanding the aeration tank, maximum average daily inflow that can satisfy the effluent water quality standard of BOD $0.02kg/m^3$ was determined as $2,840m^3/hr$, subject to 100% of activated-sludge return rate while other factors remain constant. When the activated-sludge return rate is less than 100%, expansion of the aeration tank is necessary and minimum sizes of the aeration tank to satisfy the effluent water quality standard were determined for various activated-sludge return rates. In addition, the total operating and maintenance as well as unit treatment cost regression equations for activated-sludge wastewater treatment plants are suggested by using the cost data that are obtained from Water and Wastewater Division, Ministry of Environment. The regression analyses showed that the economies of scale phenomena exist in the operating and maintenance costs of activated-sludge wastewater treatment plants.

온라인자료의 기계적 품질계수 측정을 통한 컨스펙터스 운영모형에 관한 연구 (A Study on an Operating Model of Conspectus for Online Resources based on Mechanistic Quality Factor)

  • 우진영;류성열
    • 한국도서관정보학회지
    • /
    • 제43권4호
    • /
    • pp.183-199
    • /
    • 2012
  • 본 연구는 기계적 품질계수 개념을 도입하여 온라인자료에 적합한 컨스펙터스 운영모형을 개발하기 위한 것이다. 온라인자료의 주제별 소장율, 이용율, 검색율 등 자료활용행태에 관한 정보를 토대로 주제별 기계적 품질계수를 산출한 후 이를 기존의 컨스펙터스의 주제별 집서수준에 반영하는 방식으로 운영할 것을 제안하였다. 그 결과 이용율이 높은 기술과학과 검색율이 높은 역사와 사회과학 등 주제의 집서수준을 대폭 상향조정하고 여타주제들은 현행유지 또는 하향조정 되어야 하는 것으로 나타났다.

'계획에 없던 재수술' 의 분석 (An analysis of unplanned reoperation)

  • 김은경;조성현;김창엽;오병희
    • 한국의료질향상학회지
    • /
    • 제2권1호
    • /
    • pp.118-124
    • /
    • 1995
  • Background: Clinical indicators are objective measures of process or outcome of patient care in quantitative terms. This study aims to review the medical records of patients who 'return to operating room during the same admission', which is one of the critical clinical outcomes, and describe the result by unplanned reoperation rate. Methods: Computerized patient registry was used for selecting subject conditions. For medical records retrieved, two nurse evaluators identified the presence of explicit reoperation planning in medical records. Results: Overall reoperation rate was 2.8% and unplanned reoperation rate 1.3%. The main category of reoperation cause was the postoperative bleeding. Duration of stay from previous operation to reoperation of the unplanned group, 12.7 days, was shorter than that of the planned(p< .05). The differences did not reach statistical significance in age, sex and length of stay. Conclusion: Results suggested that unplanned reoperation rate was lower than 'threshold' level other institutions had established. However, this result could become comparable only after management of medical records would be improved and risk adjusted.

  • PDF