• Title/Summary/Keyword: Operating Profile

Search Result 266, Processing Time 0.023 seconds

MDA(Model Driven Architecture) based Design for Multitasking of Heterogeneous Embedded System (이종 임베디드 시스템의 멀티태스킹을 위한 MDA(Model Driven Architecture) 기반의 설계)

  • Son, Hyun-Seung;Kim, Woo-Yeol;Kim, R. Young-Chul
    • The KIPS Transactions:PartD
    • /
    • v.15D no.3
    • /
    • pp.355-360
    • /
    • 2008
  • The complicated embedded system for multi-tasking requires RTOS(real-time operating system). It uses the optimal OS and processor to each embedded system on the heterogeneous development environment. This paper is proposed to use UML profile of OS API and Processor Configuration, instead of cross-compiling for developing the heterogeneous embedded system. This reduces the development time and cost through generating the automatic source code with the profile information of each embedded system. We generate and port the code after modeling the two heterogeneous real time operating systems (brickOS and uC/OS-II) and the processors (Hitachi H8 and Intel PXA255) with our proposed profile of the heterogeneous embedded system.

Utility of False Profile View for Screening of Ischiofemoral Impingement

  • Kwak, Dae-Kyung;Yang, Ick-Hwan;Kim, Sungjun;Lee, Sang-Chul;Park, Kwan-Kyu;Lee, Woo-Suk
    • Hip & pelvis
    • /
    • v.30 no.4
    • /
    • pp.219-225
    • /
    • 2018
  • Purpose: Ischiofemoral impingement (IFI)-primarily diagnosed by magnetic resonance imaging (MRI)-is an easily overlooked disease due to its low incidence. The purpose of this study was to evaluate the usefulness of false profile view as a screening test for IFI. Materials and Methods: Fifty-eight patients diagnosed with IFI between June 2013 and July 2017 were enrolled in this retrospective study. A control group (n=58) with matching propensity scores (age, gender, and body mass index) were also included. Ischiofemoral space (IFS) was measured as the shortest distance between the lateral cortex of the ischium and the medial cortex of lesser trochanter in weight bearing hip anteroposterior (AP) view and false profile view. MRI was used to measure IFS and quadratus femoris space (QFS). The receiver operating characteristics (ROC), area under the ROC curve (AUC) and cutoff point of the IFS were measured by false profile images, and the correlation between the IFS and QFS was analyzed using the MRI scans. Results: In the false profile view and hip AP view, patients with IFI had significantly decreased IFS (P<0.01). In the false profile view, ROC AUC (0.967) was higher than in the hip AP view (0.841). Cutoff value for differential diagnosis of IFI in the false profile view was 10.3 mm (sensitivity, 88.2%; specificity, 88.4%). IFS correlated with IFS (r=0.744) QFS (0.740) in MRI and IFS (0.621) in hip AP view (P<0.01). Conclusion: IFS on false profile view can be used as a screening tool for potential IFI.

A Study on the Development of the Gear Design Program Using Auto_LISP (Auto_LISP을 이용한 기어설계 프로그램 개발에 관한 연구)

  • 이경원;반재삼;김종석;조규종
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.11 no.2
    • /
    • pp.36-42
    • /
    • 2002
  • After investigating repeatedly results obtained through gear stress analysis, we make a determination of an optimal gear shape. But its design process was not only complex but also difficult to get a precise profile curve from operating by hand. In this study, relating shape of gear profile curves was generated automatically with standard spur gear, equivalent helical gear, shifted gear & pinion by using developed program which is using Auto_LISP language in Auto-CAD. This program which can design rapidly gear shapes will successfully support gear designing and manufacturing fur Small & Medium companies.

Maintaining Optimal Voltage Profile by the Operation of UPFC (UPFC 운용에 의한 전력 시스템 최적 전압 유지)

  • Kim, Tae-Hyun;Moon, Chae-Joo;Park, Jong-Keun;Moon, Seung-Il;Seo, Jang-Cheol;Han, Byung-Moon
    • Proceedings of the KIEE Conference
    • /
    • 2000.07a
    • /
    • pp.265-267
    • /
    • 2000
  • A method to compute the reactive powers of the added buses by the decoupled UPFC model for the optimal voltage profile is presented, by which the voltage magnitudes of PQ buses can get closer to the reference value(usually one p.u.). The performance index for assessing how much the voltage magnitude is closer to the reference value is defined as the squared sum of the present voltage minus the reference voltage multiplied by the weighting number associated with the relative importance of the buses. Numerical example in a 10-unit 39-bus power system with 2 UPFC's shows that the performance index can be very much reduced by operating multi UPFC's with the reactive powers for the optimal voltage profile proposed in this paper.

  • PDF

A Study on the Development of the Gear Design Program by using Auto_LISP (Auto_LISP을 이용한 기어설계 프로그램 개발에 관한 연구)

  • 조규종;김종석
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2000.10a
    • /
    • pp.422-427
    • /
    • 2000
  • Gear design carried in former type determined a few variables like module, pressure angle, helix angle. After investigating repeatedly results obtained through stress analysis and making a determination an optimal shape, but its design process was not only complex but also difficult to get a precise profile curve from operating by hand. In this study, rotating shape of gear profile curves were generated automatically with standard spur gear, equivalent helical gear, shifted gear & pinion by using developed program which is Auto_LISP language supported in Auto-CAD. Output tooth profile by using CAE program is applied as Preprocessor for stress analysis in each contact points. This program which can be determined rapidly an optimal shape of gear will be successfully supported for Small & Medium companies designing and manufacturing gears by using Auto-CAD.

  • PDF

Mandatory Access Control Protection Profile for Secure Operating System (보안 운영체제를 위한 강제적 접근 제어 보호 프로파일)

  • Ko Young Woong
    • Journal of the Korea Society of Computer and Information
    • /
    • v.10 no.1 s.33
    • /
    • pp.141-148
    • /
    • 2005
  • Nowadays, it is possible to access sharing data from unauthorized People. Access control prevents unauthorized access to computing resource, information resources, and communication resources. It is very important to defend the critical system resources from the unauthorized. The importance of this study is to develop Protection Profile for Mandatory Access Control (MAC) that satisfies TCSEC assurance level B2. protection profile for MAC will help developers to use reference for the development of requirements and formulating security specification.

  • PDF

GMA Torch Configuration for Efficient Use of Argon Gas Part 2 : Comparison between AMAG DMAG Process (아르곤 가스를 효율적으로 사용하기 위한 GMA 용접 토치 구조 Part 2 : AMAG와 DMAG 공정의 비교)

  • 문명철;고성훈;유중돈
    • Journal of Welding and Joining
    • /
    • v.17 no.6
    • /
    • pp.46-52
    • /
    • 1999
  • The auxiliary gas-shielded MAG (AMAG) process, which was devised to provide an argon-rich shielding environment using small amount of argon gas, was investigated experimentally to figure out its effects on metal transfer and weld quality. Proper conditions for the AMAG process including the argon gas ratio, position and direction of the auxiliary nozzle were determined experimentally. Performance of the AMAG process was compared with that of the double gas-shielded MAG(DMAG) and MAG processes by monitoring the bead profile, current and voltage waveforms. The AMAG process was found to provide better bead profile, more stable arc and wider operating range of spray transfer mode compared with the DMAG process. In general, performance of the AMAG process using the argon ratio of 30% was comparable to that of the MAG process using 80% argon and 20% CO₂ gas.

  • PDF

Compound effects of operating parameters on burnup credit criticality analysis in boiling water reactor spent fuel assemblies

  • Wu, Shang-Chien;Chao, Der-Sheng;Liang, Jenq-Horng
    • Nuclear Engineering and Technology
    • /
    • v.50 no.1
    • /
    • pp.18-24
    • /
    • 2018
  • This study proposes a new method of analyzing the burnup credit in boiling water reactor spent fuel assemblies against various operating parameters. The operating parameters under investigation include fuel temperature, axial burnup profile, axial moderator density profile, and control blade usage. In particular, the effects of variations in one and two operating parameters on the curve of effective multiplication factor ($k_{eff}$) versus burnup (B) are, respectively, the so-called single and compound effects. All the calculations were performed using SCALE 6.1 together with the Evaluated Nuclear Data Files, part B (ENDF/B)-VII238-neutron energy group data library. Furthermore, two geometrical models were established based on the General Electric (GE)14 $10{\times}10$ boiling water reactor fuel assembly and the Generic Burnup-Credit (GBC)-68 storage cask. The results revealed that the curves of $k_{eff}$ versus B, due to single and compound effects, can be approximated using a first degree polynomial of B. However, the reactivity deviation (or changes of $k_{eff}$, ${\Delta}k$) in some compound effects was not a summation of the all ${\Delta}k$ resulting from the two associated single effects. This phenomenon is undesirable because it may to some extent affect the precise assessment of burnup credit. In this study, a general formula was thus proposed to express the curves of $k_{eff}$ versus B for both single and compound effects.

Health Promoting Behavior and Factors in Operating Room nurses (수술실 간호사의 건강증진행위와 관련 요인)

  • Choi, JiYun;Choi-Kwon, Smi
    • Journal of Korean Biological Nursing Science
    • /
    • v.21 no.4
    • /
    • pp.308-317
    • /
    • 2019
  • Purpose: This study aimed to investigate the level and related factors related to health-promoting lifestyle in operating room nurses in Korea. Method: A cross-sectional descriptive survey design was employed. The data were collected using questionnaire for three weeks in December 2018 from 110 operating room nurses working for more than six months in a general hospital located in Seoul. The Health Promoting Lifestyle Profile-II, The Korean Version of the Practice Environment Scale of Nursing Work Index, and Operating nurse's Job stress Factor Scale were used. Results: Significant relationships were observed between health promoting lifestyle and educational level(p= .025), perceived economic status (p= .001) wearing a lead apron for protection from radiation during the operation(p< .001), work satisfaction(p= .016), and fatigue related to work(p= .006). Also significant correlations were identified between nursing work environment and health promoting lifestyle. However, the health promoting lifestyle was not statistically different based on occupational stress(p= .365). In multiple linear regression analyses, the level of health promoting lifestyle found to be higher in subjects who did not wear a lead apron for protection from radiation(p= .017), and who had more positive perception of the nursing work environment(p= .034). Conclusion: In order to increase health promoting lifestyle of operating nurses, the strategies to improve the nursing work environment are essential.

Optimum Cam Profile Design and Experimental Verification on an OHC Type Cam-valve System (OHC형 캠-밸브 기구의 최적 캠 형상설계 및 실험적 검증)

  • 김성훈;김원경;박윤식
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.16 no.11
    • /
    • pp.2049-2058
    • /
    • 1992
  • In this work, a 6 degree of freedom lumped mass model is constructed for an OHC-type cam valve train analysis, and the model is verified experimentally. Using the verified model, an optimum cam profile is designed to minimize the maximum contact force between cam and follower under the constraints such as cam lift and cam event angle. The designed cam was carefully machined and tested experimentally. As operating the designed cam shaft on the test rig, the valve motion was precisely measured with laser displacement meter and the contact force was indirectly monitored by measuring strain at a certain point of the finger follower. Judging from the model simulation and experiment results, the maximum contact force can be reduced as much as more than 16.7 percent under maintaining the original valve flow area by adopting the optimum cam profile.