• Title/Summary/Keyword: Operating Point

Search Result 1,758, Processing Time 0.029 seconds

HPC(High Performance Computer) Linux Clustering for UltraSPARC(64bit-RISC processor) (UltraSPARC(64bit-RISC processor)을 위한 고성능 컴퓨터 리눅스 클러스터링)

  • 김기영;조영록;장종권
    • Proceedings of the IEEK Conference
    • /
    • 2003.11b
    • /
    • pp.45-48
    • /
    • 2003
  • We can easily buy network system for high performance micro-processor, progress computer architecture is caused of high bandwidth and low delay time. Coupling PC-based commodity technology with distributed computing methodologies provides an important advance in the development of single-user dedicated systems. Lately Network is joined PC or workstation by computers of high performance and low cost. Than it make intensive that Cluster system is resembled supercomputer. Unix, Linux, BSD, NT(Windows series) can use Cluster system OS(operating system). I'm chosen linux gain low cost, high performance and open technical documentation. This paper is benchmark performance of Beowulf clustering by UltraSPARC-1K(64bit-RISC processor). Benchmark tools use MPI(Message Passing Interface) and NetPIPE. Beowulf is a class of experimental parallel workstations developed to evaluate and characterize the design space of this new operating point in price-performance.

  • PDF

Operating Characteristics Analysis of PWM Boost AC-AC Converter for Compensation of Voltage Sag (전압 Sag 보상을 위한 PWM Boost AC-AC 컨버터의 동작 특성 해석)

  • 최남섭
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2003.10a
    • /
    • pp.315-319
    • /
    • 2003
  • This paper presents modeling and analysis of static and dynamic characteristics in PWM Boost AC-AC converter used for input voltage sag compensation of custom power. Especially, using circuit DQ transformation technique, an equivalent circuit in fundamental frequency domain is obtained which has all the system characteristics. Moreover, voltage gain and input power factor is analytically induced and linearized state equation at the specific operating point is given. Finally, simulation results show the validity of the proposed modelling and analyses.

  • PDF

Performance Evaluation of Side Channel Type Regenerative Blower (사이드채널형 재생블로워의 성능평가)

  • Lee, Kyoung-Yong;Choi, Young-Seok
    • 유체기계공업학회:학술대회논문집
    • /
    • 2005.12a
    • /
    • pp.378-383
    • /
    • 2005
  • The performances of side channel type regenerative blowers were evaluated by the blower performance test, 1-D performance prediction and CFD. The performance prediction method was modified using the results of the performance test and CFD and applied to the design of the new regenerative blowers. The major geometric parameters such as channel height, channel area and expansion angle were decided from the performance prediction method for the improved models and the predicted results were compared with CFD and experimental data. Both of the modified models showed improved efficiency at the operating condition. Especially, model3 could be possible to reduce operating rotating speed, that is benefit to noise performance, because of the high head performance at the design point. The CFD results showed that the performance of the regenerative blower was influenced by the secondary circulatory flow in the channel.

  • PDF

Transient Analysis of a Simple Cycle Gas Turbine Engine

  • Kim, SooYong;Soudarev, B.
    • International Journal of Aeronautical and Space Sciences
    • /
    • v.1 no.2
    • /
    • pp.22-29
    • /
    • 2000
  • A method to simulate the gas turbine transient behavior is developed. The basic principles of the method and main input data required are described. Calculation results are presented in terms of whole operating regime of the engine. The influence of initial parameters such as starting engine power, moment of inertia of the rotor, fuel schedule on performance characteristics of gas turbine during transient operation is shown. In addition, the effect of bleeding air on transient behavior is also considered. For validation of the developed computer code, a comparative analysis with experimental data obtained from a heavy duty gas turbine is made. Calculation results agree well with the experimental data for the range of operating regime studied and proved applicability of the developed technique to initial design stage of control system.

  • PDF

A Study on the Characteristics of D. I. Diesel Spray·Flame in Operating Condition (Analysis by Diffused Background Illumination Method) (운전조건에 따른 D.I. 디젤기관의 분무·화염의 특성에 관한 연구 (배경산란광그림자사진법에 의한 해석))

  • Ra, J.H.;Lee, D.B.;Ahn, S.K.
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.3 no.6
    • /
    • pp.30-40
    • /
    • 1995
  • Optically accessible D. I. diesel engine with a rectangular combustion chamber was constructed to visualize the behaviors of sprays and flames in the combustion camber with the close conditions of pressure and temperature in an actual engine. The behaviors of sprays and flames in the combustion chamber as the operating conditions of this engine were photographed with high speed camera by Diffused Background Illumination Method. With photographs taken by this method, behavior of spray droplets injected into the combustion chamber, ignition points, and flame propagation were observed and analyzed at a time-and space-dependent fashion.

  • PDF

A Novel High-Frequency Resonant Type PWM DC/DC Converter (고주파 공진형 PWM 인버어터 제어 DC/DC 콘버어터)

  • Lee, Jong-Moo;Wee, Sang-Bong;Koo, Heun-Hoi;Kim, Yo-Hee
    • Proceedings of the KIEE Conference
    • /
    • 1987.11a
    • /
    • pp.343-346
    • /
    • 1987
  • This paper proposes a novel high-frequency resonant DC/DC converter having PWM(Pulse Width Modulation) inverter control function. The operating characteristics of this converter circuit are discussed from a thereotical point of view and compared with experimental results. The results of operating characteristic analysis are given leading to complete designing data.

  • PDF

The Analysis of a High Frequency Series Resonant DC-DC Converter (고주파 직렬공진형 DC-DC Converter의 특성 해석)

  • 이윤종;김철진
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.39 no.9
    • /
    • pp.934-943
    • /
    • 1990
  • There are no turn-on losses in the series Resonant Converter which operates above the resonance frequency, and the commutation stress on the switched component is low. For a given Series Resonant Converter with specified load resistance, the output voltage is a function of the operation frequency. This paper describes the static and dynamic characteristic analysis of the Series Resonant DC to DC Converter, which is operating above the resonant frequency, with frequency control. For the analysis method, state plane technique is adopted, and the circuit operation is defined from normalized switching frequency, Fsn. Under this condition, circuit performance is analyzed ideally. The validity of the proposed analysis is verified by comparing with experimental results, the stability of the converter is confirmed against small variations around the operating point by conventional frequency domain analysis, and the stress quantity added to switch component is shown.

  • PDF

Robust design of a steer-by-wire control system using QFT (QFT를 이용한 SBW 시스템의 강인 제어기 설계)

  • Kim, Seok-Woo;Kwon, Hyuk-Lyong;Kim, Young-Chol
    • Proceedings of the KIEE Conference
    • /
    • 1997.07b
    • /
    • pp.504-506
    • /
    • 1997
  • The steer-by-wire (SBW) system has nonlinear dynamics inherently. In classical approach, the controller has been designed on a linearized model which corresponds to only an operating point. In this paper, a set of linearized model that is generated at different operating ranges is replaced by a linear transfer function having parametric uncertainty. Then a design method for robust control using QFT is represented. The Kharitonov like analyses shows that the proposed controller satisfies the given robust performance specifications well.

  • PDF

An Analysis of the Water Supply System with Pressurizing Tank (가압탱크를 이용한 급수시스템의 해석 및 최적화 연구)

  • Lee, T.W.;Kim, T.H.;Choi, D.H.;Kim, S.D.;Kim, J.P.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.6 no.2
    • /
    • pp.93-102
    • /
    • 1994
  • It is the goal of this study to provide the essential data for design and operation of optimum water supply system. Experimental and theoretical analyses have been conducted for various parameters, for example, volume and air percent of pressurizing tank, pump speed and pressure range inside tank, etc. Pressure inside tank with time, flow rate, energy consumption rate and pump operation time have been obtained for design and operating parameters to optimize the components and to establish the operating method of system, and therefore to contribute to the development of technology from a point of view of the improvement of quality, the enhancement of system efficiency and the reduction of construction cost.

  • PDF

A Design of High-Speed Linear Actuator for Valve (밸브 구동용 고속 리니어 액추에이터)

  • Sung, B.J.
    • Transactions of The Korea Fluid Power Systems Society
    • /
    • v.8 no.1
    • /
    • pp.1-9
    • /
    • 2011
  • The main design factors which effect on operating speed of linear actuator for valve operation are mass of plunger, electromagnetic motive force, inductance, and return spring, and these factors are not independent but related with each other in view point of design and electromagnetic theory. It is impossible to increase the operating speed by only change the value of any one design factor. The change of any one value results in change of any value related it in various design factors. This paper presents a speed increasing method of linear actuator using a solenoid design method by some governing equations which are composed of electromagnetic theory and empirical knowledge and permanent magnets as assistant material, and proved the propriety by experiments.