• 제목/요약/키워드: Operating Point

검색결과 1,752건 처리시간 0.029초

Improved Global Maximum Power Point Tracking Method Based on Voltage Interval for PV Array under Partially Shaded Conditions

  • Ding, Kun;Wang, Xiang;Zhai, Quan-Xin;Xu, Jun-Wei;Zhang, Jing-Wei;Liu, Hai-Hao
    • Journal of Power Electronics
    • /
    • 제14권4호
    • /
    • pp.722-732
    • /
    • 2014
  • The power-voltage (P-V) curve of photovoltaic (PV) arrays connected in parallel to bypass diodes would have several local maximum power points (LMPP) under partial shading conditions (PSC). Conventional maximum power point tracking (MPPT) methods fail to search for the global maximum power point (MPP) because the searched peak point may remain at the LMPP on the P-V curve under PSC. This study proposes an improved MPPT algorithm to ensure that PV arrays operate at global maximum power point (GMPP) under PSC. The proposed algorithm is based on a critical study and a series of observations of PV characteristics under PSC. Results show the regularity of voltage interval between LMPPs. The algorithm has the advantages of rapidly reaching GMPP, maintaining stability, and recovering GMPP quickly when the operating condition changes. Simulation and experimental results demonstrate the feasibility of the proposed algorithm.

Study on Performance of Adaptive Maximum Torque Per Amp Control in Induction Motor Drives at Light Load Operation

  • Kwon, Chun-Ki;Kong, Yong-Hae;Kim, Dong-Sik
    • Journal of Electrical Engineering and Technology
    • /
    • 제12권1호
    • /
    • pp.249-255
    • /
    • 2017
  • Efficient operation of induction motor at light loads has been getting wide attention recently because the operating of induction motor at light loads occupies big portion of its operating regions in many applications such as environment friendly vehicle. As one of approaches to improve efficiency, Adaptive Maximum Torque Per Amp (Adaptive MTPA) control for induction motor drives has been proposed to achieve a desired torque with the minimum possible stator current. However, the Adaptive MTPA control was validated only at heavy load where, in general, control scheme tends to perform better than at light loads since the error in measurement of sensors is lower and signal to noise is better. Thus, although the performance of a control scheme is good at rated operating point, its performance at light load is somewhat in doubt in practice. This has led to considerable interest in efficiency of Adaptive MTPA control at light loads. This work experimentally demonstrates performance of Adaptive MTPA control at light loads regardless of rotor resistance variation, thus showing its good performance over all operating conditions.

PID Controller Tuning using Co-Efficient Diagram method for Indirect Vector Controlled Drive

  • Durgasukumar, G.;Rama Subba Redddy, T.;Pakkiraiah, B.
    • Journal of Electrical Engineering and Technology
    • /
    • 제12권5호
    • /
    • pp.1821-1834
    • /
    • 2017
  • Medium voltage control applications due to obtain better output voltage and reduced electro-magnetic interference multi level inverter is used. In closed loop control with inverter, the PI controller does not operate satisfactorily when the operating point changes. This paper presents the performance of Co-Efficient diagram PI controller based indirect vector controlled induction motor drive fed from three-level inverter under different operating conditions (dynamic and steady state). The proposed Co-Efficient diagram PI controller based three level inverter significantly reduces the torque ripple compared to that of conventional PI controller. The performance of the indirect vector controlled induction motor drive has been simulated at different operating conditions. For three-level inverter control, a simplified space vector modulation technique is implemented, which reduces the coordinate transformations complications in the algorithms. The performance parameters, torque ripple contents and THD of induction motor drive with three-level inverter is compared under different operating conditions using CDM-PI and conventional PI controllers.

운전점이 다른 소형 축류홴의 난류 유동장 고찰 (Investigation on the Turbulent Flow-Field of a Small-size Axial Fan with Different Operating Points)

  • 김장권
    • 동력기계공학회지
    • /
    • 제12권5호
    • /
    • pp.40-47
    • /
    • 2008
  • The turbulent flow characteristics around a small-size axial fan(SSAF) for a refrigerator are strongly dependent upon the operating points. Four operating points such as $\phi$ =0.1, 0.18, 0.25 and 0.32 were adopted in this study to investigate three-dimensional turbulent flow characteristics around the SSAF by using a fiber-optic type Laser Doppler Anemometer(LDA) system. Downstream mean velocity profiles of the SSAF along the radial distance show that axial and tangential velocity components exist predominantly, except $\phi$ = 0.1, and have a maximum value at $r/R{\fallingdotseq}0.8$, but radial velocity component having a relatively small value only turns flow direction to the outside or the central part of the SSAF. The turbulent intensity shows that the radial component exists most greatly after $r/R{\fallingdotseq}0.5$. Downstream turbulent kinetic energy at $\phi$ = 0.25 and 0.32 together has the largest peak value at $r/R{\fallingdotseq}0.9$.

  • PDF

MPA 유량계 압력감지공의 위치와 유출계수 (Location of pressure sensing holes in MPA flowmeter and discharge coefficients)

  • 김기현;최성길
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2004년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.160-165
    • /
    • 2004
  • MPA (Multi-Point Averaging) flow element is a new type of differential pressure (DP) flow-sensing device that was developed by Seojin Instech to improve the operating characteristics of the conventional Averaging Pilot Tube (APT) flow elements. Operating characteristics of a flowmeter in general can be defined in terms of measurement accuracy and range. Improvement of accuracy and expanding the range of flow measurement were the two main objectives of the development. To achieve these dual objectives several upstream and downstream pressure-sensing holes were placed in MPA flow element. During the course of the development it was found that certain arrangements of the pressure-sensing holes improved measurement accuracy but did not expand operating flow range of Averaging Pilot Tubes. Development tests were performed with water between Reynolds number of 50,000 and 1,000,000 in the four-inch test line at the Alden Research Laboratory, U.S.A. Purpose of this paper is to present the relationship between the various locations of the pressure-sensing holes and the performance characteristics of MPA flow element. Furthermore, the operating characteristics of the best performing MPA are compared with those of typical orifice and APT.

  • PDF

최적화 기법을 이용한 빗물펌프장 최적 운영수위 결정 (Determination of Optimal Operation Water Level of Rain Water Pump Station using Optimization Technique)

  • 심규범;유도근;김응석
    • 한국산학기술학회논문지
    • /
    • 제19권7호
    • /
    • pp.337-342
    • /
    • 2018
  • 도시유역에서 발생되는 내수침수를 방어하는 수단으로 구조적 대책인 빗물펌프장이 있으나 현실적 적용에 어려움이 있기 때문에 비구조적 대책 등이 보안되어야 한다. 본 연구에서는 빗물펌프장 실무운영 담당자의 의견을 반영한 최소의 월류량을 가지는 펌프의 최적운영수위를 결정하였다. 빗물펌프장의 최적운영수위를 산정하기 위해 최적화 기법인 GA(Genetic Algorithm)을 이용하였으며, 도시유역의 강우-유출 모형인 SWMM(Ver.5.1) DLL과 연계하였다. 제약조건으로는 펌프의 효율을 극대화하는데 까지의 걸리는 시간을 고려하였으며, 최적운영수위를 산정한 결과 전체적으로 기존운영수위보다 낮은 운영 수위에서 월류량이 감소하였다. 대부분 펌프의 경우 각 펌프 호기의 운영 범위에서 가장 낮은 운영 수위가 선정되었다. 초기 펌프의 운영하는 것이 월류량을 저감할 수 있는 것으로 판단되며 이 후 펌프 운영 조건 변경을 하여도 월류 저감에 변화는 없는 것으로 나타났다. 내수침수 저감정도는 약 1%~2%로 산출되었으며, 하류지역에서 발생되는 월류량을 저감하는 정도이지만, 펌프의 운영적 관점에서 기계적 및 실무적 관점의 접근에 따른 효과적인 운영이라 판단된다. 향후, 펌프의 운영조건 등을 고려한다면, 펌프의 효율을 증대하고 내수침수를 저감하는데 도움이 되리라 판단된다.

국도 4차로 곡선부에서 주행속도의 특성 및 모형 (Characteristics and Modeling of Operating Speed at Horizontal Curves on Rural Four-Lane Highways)

  • 고종대;장명순;정준화
    • 대한교통학회지
    • /
    • 제20권7호
    • /
    • pp.95-105
    • /
    • 2002
  • 특정 설계속도 기준에 따라 도로의 선형 조건이 주어졌을 때, 설계자가 기대했던 것만큼의 속도로 운전자가 차량을 주행하는지는 도로의 안전성을 좌우하는 기본 틀을 형성한다. 본 연구는 국도 4차로 평면 단곡선부의 1차로를 공간적 범위로 설정하고, 진입부 직선도로∼곡선부도로∼진출부 직선도로로 구분하여 선행차량에 의해 영향을 받지 않는 승용차의 주행속도를 NC-97장비를 이용하여 조사하였다. 다양한 곡선부 기하조건 하에서 직선부 85백분위 주행속도(Vt)와 곡선부 85백분위 주행속도 (Vc) 특성을 분석한 결과, 곡선부에서 평균 S3∼65%정도의 많은 운전자들이 제한속도(80kph) 보다 평균14∼20kph 정도 높게 주행하고, 곡선부 85백분위 주행속도가 낮은 지점은 곡선반경이 작을 때는 곡선부 중앙(2L/4)이었으나 곡 선반경이 커지면 곡선부 L/4지점으로 이동(단, L=곡선장)하고, 곡선반경에 따른 직선부·곡선부 85백분위 주행속도 차이는 곡선반경이 작을수록 커지고 곡선반경이 클수록 작아진다는 연구 결과가 도출되었다. 또, 현장조사결과와 개발한 모형을 통하여 곡선부 주행속도에 영향을 미치는 중요한 인자로는 곡선반경과 직선부 85백분위 주행속도라는 연구결과가 도출되었다.

주석 도금 두께에 따른 퓨즈 가용체의 I-T 커브 및 전기적 특성의 영향 (Effect the I-T curve and electrical characteristic of fuse elements by plated tin thickness)

  • 진상준;김은민;윤재서;이예지;노성여
    • 한국산학기술학회논문지
    • /
    • 제19권6호
    • /
    • pp.80-87
    • /
    • 2018
  • 최근 다양한 신재생 에너지 전력원의 확산과 저전력 고효율화 추구로 인하여 전력산업의 트렌드뿐만 아니라 소모량, 제어 방식과 동작 특성 등도 다변화되고 있다. 하지만 이와 같이 다양화 되고 있는 전력 산업에서 안전을 책임지는 핵심 부품인 퓨즈는 고전적 동작 형태에서 크게 발전하지 못하였고, 이로 인하여 계속해서 화재 및 폭발사고가 발생하고 있다. 이에 본 논문에서는 고전적 퓨즈 제작 방식인 카트리지 퓨즈에서 가용체에 저 융점 금속 도금 및 고 융점 금속 도금이 퓨즈의 동작 특성과 I-T 커브의 이동에 미치는 영향을 확인하고, 퓨즈의 동작 특성을 세분화하는 두께에 따른 도금의 영향을 고찰하여 퓨즈의 다양한 동작 특성을 구현하였다. 이와 함께 저 융점 금속의 도금이 퓨즈의 정격전류 선을 낮은 정격으로 이동시키고 동작 특성을 지연 동작의 특성으로 움직여 이를 활용한 다양한 동작 특성 설계가 가능함을 제시하였다.

회전분리망 흡착선별기의 순환 굵은골재 이물질 제거효율에 관한 연구 (A Study on Aggregate Waste Separation Efficiency Using Adsorption System with Rotating Separation Net)

  • 조성광;김규용;김경욱;선상원;박진영
    • 한국건설순환자원학회논문집
    • /
    • 제9권1호
    • /
    • pp.85-91
    • /
    • 2021
  • 건설폐기물에서 발생하는 순환골재의 분류 과정에서 발생하는 이물질을 순환골재 출하 전에 회수하기 위하여 회전분리망 흡착 선별기를 설계 및 제작하였다. 제작된 선별기의 성능을 평가하기 위하여, 순환골재에서 자체적으로 회수한 이물질 종류에 따라, 아크릴을 사용하여 규격화된 이물질 샘플을 제작하고, 선별기에서 작동하는 흡입팬의 제어주파수 및 분리망의 흡입구 위치에 따른 선별효율과 순환골재의 오분류율을 평가하여 적절한 운전점을 평가하였다. 순환골재 및 이물질을 입자로 가정한 유동해석을 통해 예측된 선별기의 운전점에서의 분류효율을 평가하였다. 성능 시험 결과 컨베이어 밸트와 흡입구의 거리가 0.2m일 때 95%의 선별효율을 보이는 것으로 나타났으나, 순환골재의 오분류율이 2% 이상으로 선별효율과 2% 이하의 오분류율을 만족하는 운전점은 흡입구 거리 0.254m에서 제어주파수 58Hz으로 나타났다. 유동해석 결과 이물질 선별기에서 순환골재의 오분류는 나타나지 않았다. 기존 순환골재 생산공정에서 이물질 저감을 위해 설치식으로 운용이 가능한 회전분리망을 이용한 풍력 선별시스템을 구축하였다.

HACCP in Changran Jeotgal

  • Park Mi-Yeon;Choi Seung-Tae;Chang Dong-Suck
    • Fisheries and Aquatic Sciences
    • /
    • 제5권1호
    • /
    • pp.48-53
    • /
    • 2002
  • The HACCP (hazard analysis critical control point) concept becomes an important aspect of Good Manufacturing Practices (GMP) in safe food production. The HACCP plan was developed with food safety objective. The authors already carried out hazards analysis on Changran Jeotgal manufacturing process in a previous report. In this study we developed a HACCP plan on the manufacturing process of Changran Jeotgal. We could decide two CCPs those were salt concentration and eliminations of foreign materials before packaging. Foreign materials should be certainly checked out with laser detector just before packaging. Salt should be maintained more than $8\%$ to inhibit pathogenic bacteria in end product. On the Jeotgal process free water is removed after salting and Jeotgal is seasoned with several subsidiary materials such as com syrup. In result end products have $8\%$ salt with water activity 0.82. Most bacteria are inhibited but some can live in this condition. Materials on the working may be contaminate by pathogens, chemicals or physical hazards. It will be decreased by SSOP (standard sanitary operating program). The SSOP needed in Jeotgal plants is nearly same as other general food manufacturing plants but essential to fulfill HACCP program.