• Title/Summary/Keyword: Opening-system

Search Result 1,567, Processing Time 0.029 seconds

Optimal Design of a Circuit Breaker for Satisfying the Specified Dynamic Characteristics (규정된 동특성을 만족하기 위한 회로차단기의 최적설계)

  • Ahn, K.Y.;Cho, S.S.;Oh, I.S.;Kim, S.H.
    • Proceedings of the KSME Conference
    • /
    • 2001.11a
    • /
    • pp.859-864
    • /
    • 2001
  • In a vacuum circuit breaker mechanism, a spring-actuated linkage system is used to satisfy the desired opening and closing characteristics of electric contacts. Because the opening and the closing dynamics of electric contacts is determined by such a linkage system, the stiffness, free length and attachment points of a spring become the important design parameters. In this paper, based on the dynamic model of the circuit breaker using a multibody dynamic program ADAMS, a optimal design procedure of determining the spring design parameters is presented. The proposed procedure is applied to the design of an opening spring for satisfying the specified opening characteristics.

  • PDF

A Study on the Closing Force according to the Opening Angle of the Door in the Smoke Control System (제연구역 출입문 개방 각도에 따른 폐쇄력에 관한 연구)

  • Oh, Won-Sin;Joung, Suck-Hwan
    • Journal of the Korea Safety Management & Science
    • /
    • v.23 no.4
    • /
    • pp.43-48
    • /
    • 2021
  • In this study, the experiment was conducted on a fire door(W × H = 0.98 m × 2.19 m) installed on the vestibule. The effective leakage area for each opening angles and closing forces derived from the impulse-momentum equation was compared and analyzed with the experimental results. As a result of the experiment, the major factors affecting the door closing forces were the pressure difference and the area of the door. The difference of door closing forces between measured and calculated values by the impulse-momentum equation showed a deviation of less than ±15% at the opening angles of 5°to 10°. At the door opening angle of 2.5°, the dynamic pressure was much higher than the measured static pressure, and this pressure difference is estimated to be air resistance acting to prevent the door from being completely closed.

Reliability of Quantifying Maximal Mouth Opening and Lateral Mandibular Shift in Individuals With and Without Temporomandibular Disorder Using Three-dimensional Ultrasound-based Motion Analysis

  • Oh, Jae-seop;Kim, Si-hyun;Kyung, Moon-su;Park, Kyue-nam
    • Physical Therapy Korea
    • /
    • v.26 no.3
    • /
    • pp.99-105
    • /
    • 2019
  • Background: Although magnetic resonance imaging is accurate, it is expensive to measure the movement of temporomandibular joint. The three-dimensional (3D) motion analysis system is an inexpensive measurement tool. Objects: This study examined the reliability of quantifying the mouth opening and lateral mandibular shift and differences between individuals with and without temporomandibular disorder (TMD) using the hygienic method of surface markers on the skin with 3D ultrasound-based motion analysis. Methods: This study included 24 subjects (12 with and 12 without TMD). Temporomandibular joint motion during mouth opening was recorded using two surface markers with 3D ultrasound-based motion analysis. An intraclass correlation coefficient [ICC (3,k)] was used to confirm the intrarater reliability of quantifying kinematic temporomandibular joint motion, and an independent t-test was used to evaluate differences in maximal mouth opening and lateral mandibular shift between the two groups. Results: Assessment of mouth opening and lateral mandibular shift showed excellent test-retest reliability with low standard error of measurement. The lateral mandibular shift and opening-lateral mandibular shift ratio were significantly increased in the TMD group during maximum mouth opening (p<.05). However, no significant difference in maximal mouth opening was observed between the groups with and without TMD (p>.05). Conclusion: This hygienic and simple surface marker method can be used to quantify the mouth opening and lateral mandibular shift at the end-range of mouth opening. The TMD group showed an increased lateral mandibular shift movement at the end-range of mouth opening. The lateral mandibular shift movement can be regarded as a symptom in the diagnosis and treatment of TMD.

Transient simulation and experiment validation on the opening and closing process of a ball valve

  • Han, Yong;Zhou, Ling;Bai, Ling;Xue, Peng;Lv, Wanning;Shi, Weidong;Huang, Gaoyang
    • Nuclear Engineering and Technology
    • /
    • v.54 no.5
    • /
    • pp.1674-1685
    • /
    • 2022
  • The ball valve is an important device in the pipeline transportation system of nuclear power plants. Its operational stability and safety directly affect the normal working of nuclear power plants. In this study, the transient numerical simulation of the opening and closing process of a ball valve was conducted on the basis of the flow interruption capability experiment of the ball valve by using the moving mesh method and inlet and outlet variable boundary conditions. The flow rate and pressure difference with time of the opening and closing process of the ball valve were studied. The internal flow characteristics of the ball valve under different relative openings were analyzed in conjunction with the typical back-step flow structure. Results show that the transient numerical results agree well with the experimental results. The internal flow characteristics of the ball valve are similar at the same opening during opening and closing process. At small opening, the spool and outlet channels easily form a back-step flow structure. The disappearance and generation of backflow vortices during opening and closing occur at 85% opening and 75% opening, respectively. With the decrease in opening degree, the difference in vortex core area in the flow channel of the ball valve spool in the opening and closing process gradually appears. The research results provide some reference value for the design and optimization of ball valves.

Valve monitoring system design and implementation using an infrared sensor and ZigBee (Zigbee와 적외선 센서를 활용한 밸브 개폐 모니터링 시스템 설계 및 구현)

  • Sim, Hyun;Oh, Jae-Chul
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.10 no.1
    • /
    • pp.73-80
    • /
    • 2015
  • The valve device is installed in hazardous areas, such as a chemical plant explosion has been sealed with fire protection device to prevent the risk of explosion. In this paper, due to the explosion-proof devices using external power the device can not be used in infrared sensors and Zigbee sensor valve device by measuring the open degree of valve opening and closing of the danger zone to check whether. Valve opening and closing operation log screen time, we propose a low-power operation monitoring system administrators to manage and control the plant. Develop power control relay board apply an improved algorithm to apply the asynchronous LPL power management. The plant monitoring system and explosion-proof valve opening and closing the valve system with the intelligent device designed and implemented and tested it.

Analyses of hydrogen risk in containment filtered venting system using MELCOR

  • Choi, Gi Hyeon;Jerng, Dong-Wook;Kim, Tae Woon
    • Nuclear Engineering and Technology
    • /
    • v.54 no.1
    • /
    • pp.177-185
    • /
    • 2022
  • Hydrogen risk in the containment filtered venting system (CFVS) vessel was analyzed, considering operation pressure and modes with the effect of PAR and accident scenarios. The CFVS is to depressurize the containment by venting the containment atmosphere through the filtering system. The CFVS could be subject to hydrogen risk due to the change of atmospheric conditions while the containment atmosphere passes through the CFVS. It was found that hydrogen risk increased as the CFVS opening pressure was set higher because more combustible gases generated by Molten Core Concrete Interaction flowed into the CFVS. Hydrogen risk was independent of operation modes and found only at the early phase of venting both for continuous and cyclic operation modes. With PAR, hydrogen risk appeared only at the 0.9 MPa opening pressure for Station Black-Out accidents. Without PAR, however, hydrogen risk appeared even with the CFVS opening set-point of 0.5 MPa. In a slow accident like SBO, hydrogen risk was more threatening than a fast accident like Large Break Loss-of-Coolant Accident. Through this study, it is recommended to set the CFVS opening pressure lower than 0.9 MPa and to operate it in the cyclic mode to keep the CFVS available as long as possible.

Development of an Automatic Face Velocity Controller for a Fume Hood System (흄후드 시스템의 면 풍속 자동 제어기 개발)

  • Kim, Hogeol;Jeong, Kyuwon
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.22 no.2
    • /
    • pp.304-309
    • /
    • 2013
  • In chemical, medical or biology laboratories Fume Hoods are basic facilities which can protect researchers from dangerous gas as blowing the contaminated air outside. After the air inside the laboratory room is sucked into the hume hood, then, it is blew out by a fan rotated by an AC induction motor. In addition, a damper controls the inside opening of a duct, which the air flows through. The face velocity, air velocity through the front door, have to be kept constant as the set value even though the opening of the door is varied. However, conventional fume hood used to be operated by operator's manual switches. So that, in this paper an automatic control system is developed which controls the face velocity by adjusting the rotating speed of the blow motor and the opening of the damper. Experiments show that this developed system can be used at such laboratories.

A method against interface disharmony before opening of a new subway line (신설 지하철 노선의 설비별 인터페이스 부조화 방지를 위한 방안 연구)

  • Min, Young-Ki;Lee, Jong-Seong;Kim, Kyoung-Shik;Kang, Deok-Won
    • Proceedings of the KSR Conference
    • /
    • 2008.11b
    • /
    • pp.1333-1343
    • /
    • 2008
  • Normally, the government or a local autonomous entity selects urban railway(subway, light rail transits etc.) system after investigating logicality about a route and announcing officially for people's convenience if the system is decided, suppliers of equipment(train, transformer, trolly wire, signal, communication, PSD, AFC etc.) are selected and ordering go forward. Stabilization of a total system is need for smooth train operation before opening to traffic by design, installation, total trial operation So, a measure against interface disharmony between each equipment is need. This treatise deals with the systematic method of management and items for interface plan from system design to opening on the evidence of experience of Gwangju subway total interface.

  • PDF

Opening and Closure Body Space Expressed in the Fashion Art

  • Huh Jung-Sun;Geum Key-Sook
    • International Journal of Costume and Fashion
    • /
    • v.5 no.1
    • /
    • pp.14-25
    • /
    • 2005
  • The objective of this study is to understand bodily extension and identity in contemporary fashion art through the analysis of 'the fashion acting on the body' among the fashion theory excluding body and the conspicuous works on the opening and covering images as a fashion art as a body-space'. This study also investigated identity problems where there are poles apart in opening and closure their bodies and body-space in which its clothing types were distorted by being de-bodilization out of the traditional and ideological expression method in contemporary fashion art from a opening and closure point of view. Image of opening and closure among body-space in fashion art can be classified into opposing structure of opening and closure. Destroying the boundary between bodily opening and closure for a primary function of clothing and dismantling the role and boundary between body and clothing, opening body-space in appearance as a reemergence of body image or the border between inner and outer are being ambiguous because of transparent material. Being representative work of this study opening body-space was expressed as an opening space image using transparency. On the contrary, closure body-space was isolated from external environment and confined in the certain space, which could limit or restraint body- action. Excluding boundary of body and clothing on the whole or in part, boundary of work becomes body-space. However, these were appeared to be a work inducing unlimited curiosity and meaning from the audience. The interpretation of artistic and body-space in fashion art are indicating the role and function of the fashion art exceeding the suggestible dimensions in the every day life of fashion. The body-space of fashion art showing similar aspect of body art today could be understood that it is substituted into an metaphorical, critical space by seeing it as a symbol system connected with social space. Therefore, contemporary fashion art should be interpreted as an equivocal space looking at the body-space with open mind.

Analysis of the Effect of Construction of Public Cremation Facilities in Jeongeup City on Cremators Number Using E-Haneul Funeral Information System in Jeollabukdo and on Cremation Rate

  • Choi, Jae-sil;Kim, Jeong-lae
    • International journal of advanced smart convergence
    • /
    • v.10 no.1
    • /
    • pp.117-124
    • /
    • 2021
  • Based on a result of we research and analysis of this study, it was analyzed that the average annual cremators number using E-Haneul Funeral Information System among the five public cremation facilities in Jeollabukdo was 9,713 in total before the opening of public creation facilities in Jeongeup City (2013-2015), while the number was 12,159 after the opening of public cremation facilities in Jeongeup City (2016-2019); the number was increased by 2,446, compared to the opening period (2013-2015), with a large increase rate of 25.2%. In addition, the average annual cremation rate before the opening of public cremation facilities in Jeongeup City (from 2013 to 2015) was 71.6%, but the average annual cremation rate during the period after the opening (from 2016 to 2019) was 81.5%, which was a large increase rate of 9.9% compared to period before the opening of the facilities. Based on research results above, we have presented policy suggestions in order to increase the efficiency of operation and management of public cremation facilities by local governments as follows. First, in order to prepare for the increase in demand for cremation due to the increase in cremators number, a policy promotion for the expansion of "public cremation facilities" should be carried out as soon as possible, focusing on local governments whose supply has reached the limit. Second, in order to support the expansion and construction of public cremation facilities, the government subsidy rate and government subsidy at the level of current 70%, provided by the central government, should be further expanded. Third, overcoming theNIMBY conflict overlocation for public cremation facilities, theutilization rate should be enhanced, through the joint construction and facility operation of the public cremation facilities between local governments, and the ef iciency of the project implementation should be improved through the jointsharing of the facility operation cost.