• Title/Summary/Keyword: Opening-system

Search Result 1,567, Processing Time 0.03 seconds

The necessity of ban on opening and operating the multiple medical institutions in medical law in Dental case (의료법에서의 의료기관 이중개설 금지조항의 필요성에 대한 치과 사례연구)

  • Ju, Jin-han;Lee, Ga-yeong;Jung, Ku-chan;Lee, Jae-yong;Min, Gyeong-ho
    • The Journal of the Korean dental association
    • /
    • v.57 no.9
    • /
    • pp.514-522
    • /
    • 2019
  • In accordance with Article 33(8) of the Korean Medical Law, it is stated that a medical person cannot open or operate a medical institution by borrowing the name of another medical person. However, the publicity of medical care is threatened by the recent illegal network dental clinics. The purpose of this study is to investigate the actual condition of illegal network dentistry and to analyze the cases and to find out the reason why the prohibition of double opening & operating of medical institution. As a result, the illegal network dental clinics treated less health care insurance treatment such as dental caries and periodontal treatment than general dental hospitals. In contrast, the rate of implementation of illegal network dentistry was high in endodontics treatment and extraction, which could lead to uninsured treatments such as crowns and implants. As a result of Supreme Court precedent analysis, it is concluded that illegal act is not only the opening of a medical institution by borrowing the name of other medical personnel, but also the duplicated operation which has the authority to make decision about management matters of medical institutions. The results of the patient's case survey also showed that excessive dental treatment due to such as dental staff incentive system. In conclusion, the illegal network dental clinics not only threatens the oral health of the public, but also causes leakage of health insurance premiums. In other words, the ban on opening and operating the multiple medical institution should be strictly applied as a strong protection device for protecting the patient in dental case.

  • PDF

Study on the Discharge Transients of Blowdown Flows in a Pipe

  • Lee, Kye-Bock;Kim, Hwan-Yeol;Cho, Bong-Hyun;Bae, Yoon-Yeong
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1996.05b
    • /
    • pp.102-107
    • /
    • 1996
  • The blowdown transient pipe flows resulting from the actuation of the safety/relief valve (SRV) under valve opening conditions have been analyzed. The analytical model has been developed for a uniform pipe with friction through which the flow is discharged into a suppression pool in case of a sudden opening of the SRV The piping flow characteristics and dynamic loads are calculated. Effects of system pressure, pipe length and submergence depth are included.

  • PDF

The in-use stability study of multi-use ophthalmic solutions -Focused on Olopatadine, Fluorometholone, Dorzolamide, Timolol- (다회용 점안제의 개봉 후 안정성 평가 -올로파타딘, 플루오로메톨론, 도르졸라미드, 티몰롤 약물 중심-)

  • Shin, Seo-young;Jang, Kyoung won;Sun, Sangouk;Ha, Dongmun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.2
    • /
    • pp.681-693
    • /
    • 2019
  • Multi-use ophthalmic solutions are used many times after opening; therefore, there is a high possibility of decreased quality during use. This study was conducted to determine the recommended use period of multi-use ophthalmic solutions based on evaluation of the stability by comparing stability evaluation regulations of the USA, EU and Korea We selected four types of multi-use ophthalmic solutions (Olopatadine (Olo), Fluorometholone (Flu), Dorzolamide (Dor), Timolol (Timol)) that are frequently marketed in Korea and evaluated their stability during storage according to the actual usage method after opening. The Olo had a decrease in assay and preservative content at 2 months after opening, while Flu showed a significant difference from day 28 after opening. For Dor, significant differences were observed from day 14 after opening in the assay and impurity test item and Timol showed a significant difference from day 28 after opening. Based on the results of the stability test Olo and Flu should only be used within 28 days of opening, while Dor and Timol should be used within 14 days of opening. Therefore, we suggest that regulations system related use periods of multi-use ophthalmic solutions designed as aseptic preparations should be improved based on the results of stability tests after opening.

A System Development for Remotely Controlling Windows and Doors in Mobile Environment (모바일 환경에서의 원격 창호 관제시스템 개발)

  • Cho, Yong-Hyun;Ryu, Sung-Won;Ahn, Kyung-Gyu
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.25 no.4
    • /
    • pp.334-341
    • /
    • 2015
  • This paper develops a new system for remotely monitoring and controlling the windows and doors in mobile environment. We design and implement the opening and shutting unit, the gateway, and the control server system, respectively. The opening and shutting unit consists of the driver using DC motor and the motion controller which monitors the state and transfers the control information. The gateway supports TCP/IP and CDMA protocol, which is the interface of wire and wireless communication for transferring the current state and control information. The control server consists of the program to store and process the control information, the middleware to support the processing of various state message, and DB for monitoring the state and remotely controlling the system. Especially, an application software and the Web-based user interface have also been developed to support the mobile environment. The operation performances, environment influences, driving persistences, and operation failure ratio, which are based on PC and smart-phone, have been tested in 2 authorized agencies. The test results show that the developed system has a superior performance.

Analysis of behaviour of steel beams with web openings at elevated temperatures

  • Yin, Y.Z.;Wang, Y.C.
    • Steel and Composite Structures
    • /
    • v.6 no.1
    • /
    • pp.15-31
    • /
    • 2006
  • Beams with web openings are an attractive system for multi-storey buildings where it is always desirable to have long spans. The openings in the web of steel beams enable building services to be integrated within the constructional depth of a floor, thus reducing the total floor depth. At the same time, the increased beam depth can give high bending moment capacity, thus allowing long spans. However, almost all of the research studies on web openings have been concentrated on beam behaviour at ambient temperature. In this paper, a preliminary numerical analysis using ABAQUS is conducted to develop a general understanding of the effect of the presence of web opening on the behaviour of steel beams at elevated temperatures. It is concluded that the presence of web openings will have substantial influence on the failure temperatures of axially unrestrained beams and the opening size at the critical position in the beam is the most important factor. For axially restrained beams, the effect of web openings on the beam's large deflection behaviour and catenary force is smaller and it is the maximum opening size that will affect the beam's response at very high temperatures. However, it is possible that catenary action develops in beams with web openings at temperatures much lower than the failure temperatures of the same beam without axial restraint that are often used as the basis of current design.

STUDY ON FLOW CHARACTERISTICS FOR PRECISION CONTROL BUTTERFLY VALVE (정밀제어용 버터플라이 밸브의 유동특성에 관한 연구)

  • Park, Song Mook;Choi, Hoon Ki;Yoo, Geun Jong
    • Journal of computational fluids engineering
    • /
    • v.19 no.1
    • /
    • pp.21-26
    • /
    • 2014
  • Butterfly valve is a valve that controls fluid flow depending on the size of the opening angle. In general, the size of the opening angle of the valve increases, the fluid flow has also increased sharply. However, sometimes, in a specific piping system, a particular operating condition is needed that the fluctuation of the fluid flow should not have large amount although the size of opening angle of the valve become larger. In butterfly value, the shape of a typical thin plate, it is impossible to control a minute fluid, but in thick plate type, it is possible. In this study, we got the fluid flow control characteristics and pressure drop through both a numerical method and an experimental method about thick plate type. The numerical result and experimental result of flow coefficient show a similar pattern. In addition, we could find that minute fluid flow control was possible in the area of small size of the opening angle.

Variations of Physical Oceanographic Environment Caused by Opening and Closing the Floodgate in Nakdong Estuary (수문개폐에 따른 낙동강 하구둑 하류부의 해양물리환경변화)

  • Kim Ki-Cheol;Yang Han-Soeb;Kim Cha-Kyum;Moon Chang-Ho;Jang Sung-Tae
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.2 no.2
    • /
    • pp.49-59
    • /
    • 1999
  • Nakdong Estuary is complex water system, where sea water and fresh water meet each other. After construction of Nakdong River Barrier, the flow pattern and mixing processes have been changed. Variations of physical oceanographic environment in Nakdong Estuary due to opening and closing the floodgate of Nakdong River Barrier are analysed focusing the movement of outflows from the barrier. Surveys and analysis were made for the three cases. 1. Ordinary times (opening and closing the gate by the tidal period) 2. A period of flood time (opening the gate) 3. A period of water shortage (closing the gate).

  • PDF

Cooling and Heating Performances of a CO2 Heat Pump with the Variations of Operating Conditions (운전조건 변화에 따른 이산화탄소 열펌프의 냉난방 성능특성 비교)

  • Cho, Hong-Hyun;Baek, Chang-Hyun;Lee, Eung-Chan;Kang, Hun;Kim, Yong-Chan
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.32 no.6
    • /
    • pp.454-462
    • /
    • 2008
  • Since operating conditions are significantly different for heating and cooling mode operations in a $CO_2$ heat pump system, it is difficult to optimize the performance of the $CO_2$ cycle. In addition, the performance of a $CO_2$ heat pump is very sensitive to outdoor temperature and gascooler pressure. In this study, the cooling and heating performances of a variable speed $CO_2$ heat pump with a twin-rotary compressor were measured and analyzed with the variations of EEV opening and compressor frequency. As a result, the cooling and heating COPs were 2.3 and 3.0, respectively, when the EEV opening was 22%. When the optimal EEV openings for heating and cooling were 28% and 16%, the cooling and heating COPs increased by 3.3% and 3.9%, respectively, over the COPs at the EEV opening of 22%. Beside, the heating performance was more sensitive to EEV opening than the cooling performance. As the compressor speed decreased by 5 Hz, the cooling COP increased by 2%, while the heating COP decreased by 8%.

An Analysis of the Opening and Closing Condition with Various Fire Door Size in the Pressurized Room (부속실 출입문 크기 변화를 고려한 개방 및 폐쇄조건 분석)

  • You, Woo-Jun;Nam, Jun-Seok;Ryou, Hong-Sun
    • Fire Science and Engineering
    • /
    • v.25 no.2
    • /
    • pp.132-137
    • /
    • 2011
  • A relationship between resisting moment and the structure of an automatic closure device is introduced for analyzing the effect of opening and closing condition on various fire door sizes in the pressurized room for smoke control system. The larger the size of fire door is, the more force is required for reaching to opening and closing conditions and there exists the design range of fire door in the pressurized room reflecting the closing time of fire door, rotative velocity, a relation between rotative angle and force and the efficiency of the automatic closure device.

Environmental Perception Considering Beam Opening Angle and Specular Reflection of Ultrasonic Sensors (초음파센서의 지향성 및 경면반사현상을 고려한 환경인식)

  • Ha, Yun-Su;Kim, Duck-Gon
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.30 no.8
    • /
    • pp.919-926
    • /
    • 2006
  • To move in unknown or uncertain environment, a mobile robot must collect informations from various sensors and use it to construct a representation of the external world. Ultrasonic sensor can provide range data for this purpose in a simple cost-effective way. However conventional ultrasonic sensor system for a mobile robot are not sufficient for environment recognition because of their large beam opening angle, specular reflection. This paper describe on environmental perception algorithm which can solve these problems in case using ultrasonic sensor. The algorithm consist of two parts. One is to solve beam opening angle problem by fusion from multiple ultrasonic sensors. The other is to cope with specular reflection problem in wall line extract, which is based on Hough Transform. Experiments to verify the validity of the proposed algorithm are carried out, and the results are provided at last part in this paper.