• 제목/요약/키워드: Opening rate

검색결과 705건 처리시간 0.023초

의료법에서의 의료기관 이중개설 금지조항의 필요성에 대한 치과 사례연구 (The necessity of ban on opening and operating the multiple medical institutions in medical law in Dental case)

  • 주진한;이가영;정구찬;이재용;민경호
    • 대한치과의사협회지
    • /
    • 제57권9호
    • /
    • pp.514-522
    • /
    • 2019
  • In accordance with Article 33(8) of the Korean Medical Law, it is stated that a medical person cannot open or operate a medical institution by borrowing the name of another medical person. However, the publicity of medical care is threatened by the recent illegal network dental clinics. The purpose of this study is to investigate the actual condition of illegal network dentistry and to analyze the cases and to find out the reason why the prohibition of double opening & operating of medical institution. As a result, the illegal network dental clinics treated less health care insurance treatment such as dental caries and periodontal treatment than general dental hospitals. In contrast, the rate of implementation of illegal network dentistry was high in endodontics treatment and extraction, which could lead to uninsured treatments such as crowns and implants. As a result of Supreme Court precedent analysis, it is concluded that illegal act is not only the opening of a medical institution by borrowing the name of other medical personnel, but also the duplicated operation which has the authority to make decision about management matters of medical institutions. The results of the patient's case survey also showed that excessive dental treatment due to such as dental staff incentive system. In conclusion, the illegal network dental clinics not only threatens the oral health of the public, but also causes leakage of health insurance premiums. In other words, the ban on opening and operating the multiple medical institution should be strictly applied as a strong protection device for protecting the patient in dental case.

  • PDF

A Study on the Cremation Status by the Jurisdiction Area and Outside of the Jurisdiction Area Using the E-Haneul Funeral Information System of Public Cremation Facilities in Gyeonggi-do : Focusing on Before and After the Opening of Public Cremation Facilities in Hwaseong City

  • Choi, Jae Sil;Nam, Yun Ju
    • International journal of advanced smart convergence
    • /
    • 제11권4호
    • /
    • pp.193-205
    • /
    • 2022
  • Based on the results of this study, we presented the following policy recommendations to improve the efficiency of operation and management of public cremation facilities. First, we findings the cremation number of all public cremation facilities in Gyeonggi-do increased from 39,918 people before the opening of public cremation facilities in Hwaseong to 55,642 people after the opening, showing a high rate of increase of 15,724 people(39.4%). Therefore, in order to increase the cremation ratio, the policy of expanding the supply of public cremation facilities should be actively pursued. Second, in this study we compared to before the opening of public cremation facilities in Hwaseong City, the ratio of cremation number the jurisdiction area of all public cremation facilities in Gyeonggi-do using the E-Haneul Funeral Information System increased by 19.0% from 35.9% to 54.9% after the opening, whereas it was analyzed that the outside of the jurisdiction area decreased by 19.0% from 64.1% to 45.1%. Therefore, in order to improve the convenience of citizens using the jurisdiction area, priority should be given to the promotion of policies for the establishment of public cremation facilities by local governments that do not have public cremation facilities. Third, through we research it is analyzed that the cremation ratio of the jurisdiction area of the public cremation facilities in Hwaseong City, which was jointly installed by six local governments located in Gyeonggi-do, was 92.4%, indicating that the ratio proportion of cremation number in the area is very high. Therefore, in order to improve the efficiency of the operation of public cremation facilities, the promotion of policies for joint installation and operation of public cremation facilities should be encouraged.

An experimental study on fatigue performance of cryogenic metallic materials for IMO type B tank

  • Lee, Jin-Sung;You, Won-Hyo;Yoo, Chang-Hyuk;Kim, Kyung-Su;Kim, Yooil
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • 제5권4호
    • /
    • pp.580-597
    • /
    • 2013
  • Three materials SUS304, 9% Ni steel and Al 5083-O alloy, which are considered possible candidate for International Maritime Organization (IMO) type B Cargo Containment System, were studied. Monotonic tensile, fatigue, fatigue crack growth rate and Crack Tip Opening Displacement tests were carried out at room, intermediate low ($-100^{\circ}C$) and cryogenic ($-163^{\circ}C$) temperatures. The initial yield and tensile strengths of all materials tended to increase with decreasing temperature, whereas the change in elastic modulus was not as remarkable. The largest and smallest improvement ratio of the initial yield strengths due to a temperature reduction were observed in the SUS304 and Al 5083-O alloy, respectively. The fatigue strengths of the three materials increased with decreasing temperature. The largest increase in fatigue strength was observed in the Al 5083-O alloy, whereas the 9% Ni steel sample showed the smallest increase. In the fatigue crack growth rate test, SUS304 and Al 5083-O alloy showed a decrease in the crack propagation rate, due to decrease in temperature, but no visible improvement in da/dN was observed in the case of 9% Ni steel. In the Crack Tip Opening Displacement (CTOD) test, CTOD values were converted to critical crack length for the comparison with different thickness specimens. The critical crack length tended to decrease in the case of SUS304 and increase for the Al 5083-O alloy with decreasing temperature. In case of 9% Ni steel, change of critical crack length was not observed due to temperature decrease. In addition, the changing material properties according to the temperature of the LNG tank were analyzed according to the international code for the construction and equipment of ships carrying liquefied gases in bulk (IGC code) and the rules of classifications.

도로터널 반횡류환기시스템에서 급배기 포트개도 및 화재시 운영방안에 관한 수치해석적 연구 (Numerical Study on the Supply and Exhaust Port Size and Fire Management Method in the Semi-transverse Ventilation System for Road Tunnel)

  • 유지오;김진수;이동호
    • 한국화재소방학회논문지
    • /
    • 제30권2호
    • /
    • pp.68-74
    • /
    • 2016
  • 도로터널에 적용하는 반횡류환기방식은 터널의 전연장에 걸쳐서 단위길이당 풍량이 균일하게 될 수 있도록 포트의 개도 조정이 필수적이다. 그러나 현재 국내에서 운영중인 터널의 경우에는 설계시 이에 대한 고려가 적절히 이루어지지 못하고 있는 실정이다. 이에 본 연구에서는 개도계산을 위한 프로그램을 개발하고 반횡류환기방식의 터널에서 포트의 운영방안을 제시하였다. 연구결과, 포트의 개도는 급기방식의 덕트에서는 환기소측에서 덕트의 말단(bulk head)쪽으로 갈수록 증가하였다가 감소하는 경향을 가지며, 최소 개도는 56% 정도로 나타나고 있다. 또한 배기방식에서는 환기소측이 15% 정도로 가장 작고 bulk head 쪽으로 갈수록 증가하는 경향을 보이고 있다. 화재시 300 m 구간의 배연풍량을 검토한 결과, 포트사이즈를 조정하지 않는 경우와 급기방식으로 포트사이즈을 조정한 경우에는 터널중앙부의 배연량이 각각 8.1%와 12.5%로 터널중앙부의 배연풍량이 저조한 것으로 나타났다. 따라서 반횡류환기방식의 터널에서는 평상시 환기효율이 저하하더라도 배연시 균일한 풍량을 얻을 수 있도록 포트의 개도를 설정하여 운영하는 것이 반드시 필요한 것으로 판단된다.

방사선 투시를 이용한 개폐구 운동에 따른 수직 고경 계측점의 안정성에 관한 연구 (A FLUOROSCOPIC STUDY ON THE STABILITY OF SKIN REFERENCE POINTS DURING JAW OPENING AND CLOSING MOVEMENT)

  • 안형준;김창회;김영수;김용호
    • 대한치과보철학회지
    • /
    • 제37권4호
    • /
    • pp.516-530
    • /
    • 1999
  • The current clinical technique for occlusal vertical dimension recording is based on marking the skin reference points on the patient's face and measuring between these points using caliper-like device. And it is difficult to achieve reliable measurements by this technique because of movable soft tissue. The purpose of this study is to reveal the stability of skin reference points by comparing the relative movement between extra-oral skin reference points and intra-oral reference points using X-ray fluoroscope. 10 test subjects were divided into 2 groups : Group I (natural dentition) and Group II (denture-wearer whose vertical dimension was lost) and Group III consists of identical test subjects to Group II with their upper denture removed and record base inserted. Attaching the 3 mm diameter steel ball to nose tip, lower lip, chin and to existing denture (or record base), fluoroscopic examination and recording were taken during 2 jaw opening and closing movements. After subsequent digitization using personal computer, 1219 still pictures with 0.1 second interval were made. Using the 2 dimensional graphic software, measurements between reference points were executed. Dividing the entire jaw movement into 3 ranges (total, 1st half opening, 2nd half opening), rate of movement and relative movement between extra-oral and intra-oral reference points were calculated and statistically analyzed. The results of this study are as follows. 1 Within the same experimental group, no statistical difference was found in the stability of skin reference between lower lip point and chin point during total range of jaw opening and closing movement (p>.05) 2. In the first half range of jaw opening, statistical difference was found between Group I (natural dentition) and Group II (denture wearer) (p<.05) Group I has greater skin reference stability than Group II. 3. In the first half range of jaw opening, statistical difference was found between Group I and Group III (record base wearer) (p<.05). Group I has greater skin reference stability than Group III. 4. In the first half range of jaw opening, no statistical difference was found in the stability of skin reference between Group II and Group III (p>.05). 5. In the second half range of jaw opening, no statistical difference was found in the stability of skin reference between any experimental groups (p>.05). 6. In patients with their occlusal vertical dimension lost, employing other measuring references rather than skin is recommended because of low stability.

  • PDF

압력 평형식 온도조절 밸브 내부 유동 특성에 대한 수치적 연구 (A Numerical Study on the Flow Characteristics of Temperature Control Valve by Pressure Compensation)

  • 황정훈;김태안;김윤제
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2005년도 연구개발 발표회 논문집
    • /
    • pp.448-453
    • /
    • 2005
  • Temperature Control Valve (TCV) is one of the useful temperature control devices, which is used to control constant temperature of working fluid in power and chemical plants and domestic water supply systems. TCV is composed of body, cylinder and piston, and the body shape has a symmetrical H-type. In general, it has several inlet and outlet holes, and its shape is like as tubular sleeve. The piston has three rings two rings of the end of piston have the function of controlling inlet flow rate with hot and cold working fluids, the center ring has the function of preventing hot and cold water from intermixing. Consequently, the shapes of piston and cylinder are the main design parameters in the performance of TCV. In this study, numerical analyses were carried out with two different piston and cylinder shapes to investigate the functions as a temperature control valve and the flow characteristics according to piston opening grade in TCV. Using a commercial code, FLUENT, velocity and pressure fields in TCV are obtained under steady, standard $k -{\epsilon}$ turbulence model and no-slip condition.

  • PDF

Bioassays On marine Organisms: Acute Toxicity Test Of mercury, Cadmium And Copper To Arkshell, Anadara broughtonii, From Jin-Dong Bay, And To Oyster, Crassostrea gigas, From Kwang-Do Bay, South Coast Of Korea

  • Park, Joo-Suck;Kim, Hak-Gyoon
    • 한국해양학회지
    • /
    • 제13권1호
    • /
    • pp.35-43
    • /
    • 1978
  • Short-term acute toxicity of mercury, cadmium and copper to arkshell, Anadara broughtonii, and to oyster, Crassostrea gigas, was determinedby static bioassays from 20 May to 27 June in 1977. During the observations of the opening rate of the shell mercury was the most sensitive toxicant of the three toxic substances to the test animals and caused them to close their shellvalves together after being exposed to a mercury solution for an hour during the test. Opening rate to cadmium and copper increased gradually at the higher concentration. the 96hr-LC50 values for the test animals are 4.84mg/l for mercury and 1.86mg/l for cadmium, while the 72hr-LC50 value for copper is 0.31mg/l. the death rate of oysters for cadmium showed lower than that of the mercury and copper test solutions. The 96hr-LC50 values of mercury, copper and cadmium were 1.1mg/l, 2.54mg/l and 19.5mg/l, respectively. For oysters mercury was the most toxic substance, and cadmium was the least toxic one. the medium lethal time (LT 50) value decreased gradually at higher concentration of heavy metals. The LT 50 of 2mg/l was found within 96 hours ofr copper, 104 hours for mercury and 121 hours for cadmium. The lethal threshold concentrations for 7 days were found to be about 1mg/l for mercury and copper, and 2mg/l for cadmium.

  • PDF

지열 히트펌프에서 운전변수가 냉난방 성능에 미치는 영향에 대한 실험연구 (An Experimental Study on the Effects of Operating Variables on the Cooling and Heating Performance of Geothermal Heat Pump)

  • 장근선;강희정
    • 설비공학논문집
    • /
    • 제23권8호
    • /
    • pp.562-570
    • /
    • 2011
  • In this research, an experimental study is performed to investigate the effects of system operating variables on the cooling and heating characteristics of heat pump system using geothermal heat source and carbon dioxide as a refrigerant. System variables analyzed include compressor frequency, electronic expansion valve opening, refrigerant charge, secondary fluid temperature and flow rate. Results show that optimum refrigerant charge and electronic expansion valve opening position exist at the maximum point of COP curve, and both cooling and heating capacity increase but COPs decrease with the increase of compressor frequency. The change of a secondary fluid temperature leads to variation of overheat area and enthalpy difference in the evaporator and gas cooler. which again results in considerable variations of cooling and heating capacity and COP. In the case of effects of secondary water fluid flow rate, both cooling capacity and COP increase with the increase of secondary flow in evaporator or gas cooler, whereas heating capacity and COP decrease with the increase of flow rate in gas cooler.

Increase In Mean Alveolar Pressure Due To Asymmetric Airway Geometry During High Frequency Ventilation

  • Cha, Eun-J.;Lee, Tae-S.;Goo, Yong-S.;Song, Young-J.
    • 대한의용생체공학회:의공학회지
    • /
    • 제14권1호
    • /
    • pp.89-96
    • /
    • 1993
  • During high frequency ventilation (HFV), mean alveolar pressure has been measured to increase with mean airway opening pressure controlled at a constant level in both humans and experimental animals. Since this phenomenon could potentiate barotrauma limiting advantages of HFV, the present study theoretically predicted the difference between menu alveolar and airway opening pressures ($MP_{alv}$). In a Weibel's trumpet airway model, approximated formula for $MP_{alv}$ was derived based on momentum conservation assuming a uniform velocity profile. The prediction, equation was a func pion of gas density($\rho$), mean flow rate(Q), and diameter of the airway opening where the pressure measurement was made($D_0$) : $MP_{alv}=4{\rho}(Q/D_0^{2})^2$. This was a result of the difference in crosssectional area between the alveoli and the airway opening. A simple aireway model experiment was performed and the results well fitted to the prediction, which demonstrated the validity of the present analysis. Previously reported $MP_{alv}$ data from anesthetized dogs in supine position were comparable to the predicted values, indicating that the observed dissociation between mean alveolar and airway opening pressures during HFV can be explained by this innate geometric (or cross-sectional area) asymmetry of the airways. In lateral position, however, the prediction substantially underestimated the measurements suggesting involvement of other important physiological mechanisms.

  • PDF

테들러백과 알루미늄-폴리에스터백에 보관된 저농도 아산화질소의 유실율 비교 (Comparison for Loss Rate of Low Concentration Nitrous Oxide in Tedlar Bag and Aluminium-Polyester Bag)

  • 이우찬;박성빈;고영환;현승민;윤균덕
    • 한국기후변화학회지
    • /
    • 제8권1호
    • /
    • pp.31-39
    • /
    • 2017
  • The emission quantity of nitrous oxide is second largest among non-$CO_2$ greenhouse gas in Korea. In this study, we investigated loss rate of nitrous oxide which was filled in PVF and Al-PE bag as time goes on. Concentrations of tested samples were about 25 ppmv, 50 ppmv, 75 ppmv prepared by standard reference gas. In case of all experiments, loss rate of PVF bag was higher than Al-PE bag. After 18 days, loss rate of PVF bag was from 29.7% to 38.6% while Al-PE bag was from 21.7% to 23.7%. Especially the differential growed bigger when initial concentration of $N_2O$ in PVF bag was lower. And we also studied the effect of cock opening/closing procedures on loss rate. Prepared samples in experimental group were analyzed several times for 20 days and samples in control group were analysed only 1 time after 20 days. The experimental results showed that cock opening/closing procedures appeared to have little impact on loss rate.