• 제목/요약/키워드: Open-tube

검색결과 311건 처리시간 0.027초

온실 난방을 위한 모세관형 태양열 집열기의 성능에 미치는 유량의 효과에 관한 연구 (The Effects of Water Flow Rates on the Performance of a Capillary Tube Solar Collector for Greenhouse Heating)

  • 유영선;장유섭;홍성기;윤진하;정두호;강영덕
    • 생물환경조절학회지
    • /
    • 제5권1호
    • /
    • pp.57-64
    • /
    • 1996
  • To use effectively the solar energy in greenhouse heating, a high performance solar collector should be developed. And then the size of the solar collector and thermal storage tank should be determined through the calculation of heating load. The solar collector must be set in the optimum tilt angle and direction to take daily solar radiation maximally, and the flow rate of heat transfer fluid through the solar collector should be kept in the optimum range. In this research, the performance tests of a capillary tube solar collector were performed to determine the optimum water flow rate and the results summarized as follows. 1. The regressive equations for efficiency estimations of the capillary tube solar collector in the open loop were modeled in the water flow rate of 700-l,000 $\ell$/hr. 2. The optimum water flow rate of the solar collector was estimated by the second order polynomial regression and the maximum efficiency was 80% at the water flow rate of 850 $\ell$/hr. 3. The solar thermal storage system consisted of a capillary tube solar collector and a water storage tank was tested at the water flow rate of 850 $\ell$/hr in the closed loop, and obtained the solar thermal storage efficiency of 55.2%. 4. As the capillary tube solar collector engaged in this experiment was made of non-corrosive polyolefin tubes, its weight was as light as 1/30 of the flat plate solar collector made of copper tubes. Therefore it was considered to be suitable for the greenhouse heating system.

  • PDF

용사코팅튜브와 클래드튜브 기화기에 대한 내식성 평가 (A Evaluation of Corrosion Resistance on the Thermal Sprayed Coating Tube and Cladded Tube of the Open Rack Vaporizer)

  • 백종현;이재호;김용석;신동혁;김우식
    • 한국가스학회지
    • /
    • 제2권4호
    • /
    • pp.67-72
    • /
    • 1998
  • Al-2wt.$\%$Zn 합금은 특히 해수에 대한 내식성이 우수하여 기화기 튜브의 회생양극재료로 사용되고 있다. 그러나 Al-2wt.$\%$Zn 용사코팅재는 모재금속과 코팅층사이의 결합강도부족, 해수의 낙하에너지에 의해 코팅층은 박리 된다. 이러한 용사코팅충의 문제점을 해결하고자 클래드재와 모재금속을 동시압출법을 통하여 클래드튜브 제조공정을 개발하였다. 클래드튜브의 내식성은 용사코팅튜브에 비하여 최소 2배 이상 향상되었다.

  • PDF

고속철도 터널출구에서 발생하는 충격성 소음의 저감을 위한 실험적 연구 (Experimental study on reduction of impulsive noise generating at exit of high-speed railway tunnel)

  • 김희동;뢰호구준명
    • 대한기계학회논문집B
    • /
    • 제20권7호
    • /
    • pp.2375-2385
    • /
    • 1996
  • As a compression wave is emitted from a duct, an impulsive wave generates and causes an impulsive noise that is at present a serious environmental noise pollution. In order to clarify the acoustic characteristics of the noise and to reduce their pressure levels, a series of model experiments were conducted on the impulsive waves emitted from an open end of a shock tube. The impulsive waves with various intensities were obtained by controlling the operation pressure ratio of the shock tube. Various kinds of silencers such as the exit boxes with baffle plates, were applied to the duct exit to reduce the impulsive noises. The effects of geometry of silencers and shock Mach number on the noise reduction were clarified. From the measurements of sound pressure level, it was found that installing the baffle plate into the exit box is effective in lowering the noise level at far fields, and that the recommendable geometries of silencer are L/D=1, H/D=1 and H/D=0.75.

Minimally Invasive Removal of an Intradural Cervical Tumor : Assessment of a Combined Split-Spinous Laminectomy and Quadrant Tube Retractor System Technique

  • Kwak, Young-Seok;Kim, Kyoung-Tae;Cho, Dae-Chul;Kim, Young-Baeg
    • Journal of Korean Neurosurgical Society
    • /
    • 제52권4호
    • /
    • pp.427-431
    • /
    • 2012
  • Conventional laminectomy is the most popular technique for the complete removal of intradural spinal tumors. In particular, the central portion intramedullary tumor and large intradural extramedullary tumor often require a total laminectomy for the midline myelotomy, sufficient decompression, and adequate visualization. However, this technique has the disadvantages of a wide incision, extensive periosteal muscle dissection, and bony structural injury. Recently, split-spinous laminectomy and tubular retractor systems were found to decrease postoperative muscle injuries, skin incision size and discomfort. The combined technique of split-spinous laminectomy, using a quadrant tube retractor system allows for an excellent exposure of the tumor with minimal trauma of the surrounding tissue. We propose that this technique offers possible advantages over the traditional open tumor removal of the intradural spinal cord tumors, which covers one or two cervical levels and requires a total laminectomy.

Multi-Termination Technique for the Measurement of Characteristic Impedance and Propagation Constant of Sound Absorbing Materials Using an Impedance Tube

  • Lee, Jong-Hwa;Ih, Jeong-Guon
    • The Journal of the Acoustical Society of Korea
    • /
    • 제25권2E호
    • /
    • pp.79-84
    • /
    • 2006
  • Acoustic characteristics of a sound absorbing material can be identified, if the characteristic impedance and propagation constants are known, which have generally been determined experimentally. One easy method determining these two essential parameters is to measure the one dimensional wave characteristics in the impedance tube. In th udy, the effects of backing conditions on the impedance tube measurement have been examined using several pairs of generally used end conditions. The results showed that the measured values are similar for most pairs of end conditions: however, it was observed that the measured characteristic impedance for different thickness did not agree well for some pairs. In this work, the multi termination method, using three or more known backing con ns, was suggested to reduce such random errors, which are mostly caused by the test procedure. Employing three terminations as a set, comprised of a rigid end, an end with porous material, and an end with a backing cavity, it was demonstrated that improved measured results could be obtained for an open cell PU foam varying widely with three different thicknesses.

축소/확대관 출구로부터 방출되는 펄스파에 관한 연구 (A Study on the Impulse Waves Discharged from the Exit of the Convergent/Divergent Pipes)

  • 이동훈;주경민;김현섭;김희동
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 추계학술대회논문집B
    • /
    • pp.640-645
    • /
    • 2001
  • The present study is to investigate the characteristics of the impulse waves discharged from the exit of the convergent and divergent pipes. An experiment is carried out using a shock tube with an open end and is compared to the computation of the axisymmetric, compressible, unsteady Euler equations, which are solved by the second-order total variation diminishing(TVD) scheme. For the computational work, some initial compression waves are assumed inside the pipe so that those are identical to the experimental ones of the shock tube. The results show that the peak pressures of the impulse waves discharged from the exit of convergent and divergent pipes decrease with an increase in the wavelength of the initial compression wave. All of the impulse waves have a strong directivity toward the pipe axis, regardless of the exit type of the pipe employed. The impulse waves discharged from the divergent pipe are stronger than those from the straight pipe, while the impulse waves of the convergent pipe are weaker than those from the straight pipe. It is believed that the convergent pipe can playa role of a passive control to reduce the peak pressure of the impulse wave. The present computations represent the experimented impulse waves with a good accuracy.

  • PDF

고속철도 터널에서 발생하는 파동현상에 관한 충격파관의 연구(1) - 압축파의 특성에 대하여 - (Study of Shock Tube for Wave Phenomenon in High Speed Railway Tunnel(1) - On the characteristics of Compression Wave -)

  • 김희동
    • 대한기계학회논문집
    • /
    • 제18권10호
    • /
    • pp.2686-2697
    • /
    • 1994
  • When a railway train enters a tunnel at high speed, a compression wave is formed in front of the train and propagates along the tunnel. The compression wave subsequently emerges from the exit of the tunnel, which causes an impulsive noise. In order to estimate the magnitudes of the noises and to effectively minimize them, the characteristics of the compression wave propagating in a tunnel must be understood. In the present paper, the experimental and analytical investigations on the attenuation and distortion of the propagating compression waves were carried out using a model tunnel. This facility is a kind of open-ended shock tube with a fast-opening gate valve instead of a general diaphragm. One-dimensional flow model employed in the present study could appropriately predict the strength of the compression wave, Mach number and flow velocity induced by the compression wave. The experimental results show that the strength of a compression wave decreases with the distance from the tunnel entrance. The decreasing rate of the wave strength and pressure gradient in the wave is strongly dependent on the strength of the initial compression wave at the tunnel entrance.

부하측 이상 검출 차단 장치를 내장한 고효율 자기식 네온 변압기의 설계 (Design of a High Efficiency Neon Transformer with Abnormal Load Interrupting Circuit)

  • 변재영;김윤호
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2002년도 전력전자학술대회 논문집
    • /
    • pp.723-726
    • /
    • 2002
  • In this paper, a high efficiency leakage transformer for neon tube is developed to improve its power factor, to reduce its core loss and weight by using a technique of shape optimization and direction of grain-oriented silicon steel sheet. A protection circuit is designed for all types of neon transformer loaded with one or more neon lamps. Whenever the neon tube fails to be started up or comes to the life end, or encounters faults with open-circuits at the output terminals of the neon transformer, the protection circuit will be initiated to avoid more critical hazards. These neon transformers need a protection circuit to prevent from current stresses on circuit components by neon tube fail. The input of the transformer is automatically cut off when the abnormal condition occurs, preventing waste of no-load power. As the results of the study, the core weight is reduced by $11\%$, the power factor improved by $5\%$ and the efficiency increased by $6\%$ compared with the conventional type due to the employment of the grain-oriented steel sl)eel and the optimized core shape.

  • PDF

An Experiment on Thermosyphon Boiling in Uniformly Heated Vertical Tube and Asymmetrically Heated Vertical Channel

  • Kwak, Ho-Young;Jeon, Jin-Seok;Na, Jung-Hee;Park, Hong-Chul
    • Journal of Mechanical Science and Technology
    • /
    • 제15권1호
    • /
    • pp.98-107
    • /
    • 2001
  • Continuing efforts to achieve increased circuit performance in electronic package have resulted in higher power density at chip and module level. As a result, the thermal management of electronic package has been important in maintaining or improving the reliability of the component. An experimental investigation of thermosyphonic boiling in vertical tube and channel made by two parallel rectangular plates was carried out in this study for possible application of the direct immersion cooling. Fluorinert FC-72 as a working fluid was used in this experiment. Asymmetric heated channel of open periphery with gap size of 1, 2, 4 and 26mm and uniformly heated vertical tubes with diameter of 9, 15 and 20mm were boiled at saturated condition. The boiling curves from tested surfaces exhibited the boiling hysteresis. It was also found that the gap size is not a significant parameter for the thermosyphonic boiling heat transfer with this Fluorinert. Rather pool boiling characteristics appeared for larger gap size and tube diameter. The heat transfer coefficients measured were also compared with the calculation results by Chens correlation.

  • PDF

Mechanical behavior of steel tube encased high-strength concrete composite walls under constant axial load and cyclically increasing lateral load: Experimental investigation and modeling

  • Liang Bai;Huilin Wei;Bin Wang;Fangfang Liao;Tianhua Zhou;Xingwen Liang
    • Steel and Composite Structures
    • /
    • 제47권1호
    • /
    • pp.37-50
    • /
    • 2023
  • This paper presented an investigation into steel tubes encased high-strength concrete (STHC) composite walls, wherein steel tubes were embedded at the boundary elements of high-strength concrete walls. A series of cyclic loading tests was conducted to evaluate the failure pattern, hysteresis characteristics, load-bearing capacity, deformability, and strain distribution of STHC composite walls. The test results demonstrated that the bearing capacity and ductility of the STHC composite walls improved with the embedding of steel tubes at the boundary elements. An analytical method was then established to predict the flexural bearing capacity of the STHC composite walls, and the calculated results agreed well with the experimental values, with errors of less than 10%. Finally, a finite element modeling (FEM) was developed via the OpenSees program to analyze the mechanical performance of the STHC composite wall. The FEM was validated through test results; additionally, the influences of the axial load ratio, steel tube strength, and shear-span ratio on the mechanical properties of STHC composite walls were comprehensively investigated.