• 제목/요약/키워드: Open-tube

검색결과 310건 처리시간 0.027초

흡수식냉동기용 열교환기 세관의 부식에 관한 연구 (The Study of Corrosion of Heat Exchanger Tube for Absorption Refrigeration Machine)

  • 임우조;정기철;윤병두
    • 한국마린엔지니어링학회:학술대회논문집
    • /
    • 한국마린엔지니어링학회 2002년도 춘계학술대회논문집
    • /
    • pp.147-152
    • /
    • 2002
  • This paper was studied on corrosion of heat exchanger tube for absorption refrigeration machine. In the 62 % lithium bromide solution at $60^{\circ}C$, polarization test of Cu, Al-brass, 10 % cupro nickel(90-10 % Cu-Ni) and 30 % cupronickel(70-30 % Cu-Ni) tube was carried out. And polarization behavior, polarization resistance characteristics, open circuit potential, anodic polarization of heat exchanger tube for absorption refrigeration machine were considered. The main results are as following: The open circuit potential of Al-brass tube becomes less noble than that of Cu tube, corrosion current density of that becomes lower than Cu tube. The open circuit potential of cupronickel tube is more noble than that of Cu tube, corrosion current density of that is controlled than Cu tube. The passivation critical current of 30 % Cu-Ni tube is lower than that of 10 % Cu-Ni tube, potential of passive region of that is more wide than 10 % Cu-Ni tube.

  • PDF

개방관과 밀폐관의 열음향 효과에 관한 하모닉 특성 연구(2) - 2차, 3차 하모닉 (An Experimental Study on the Characteristics for Open-Tube and Closed-Tube Thermoacoustic Effects (2)- The 2nd, 3rd Harmonic)

  • 송규조;박종호;이성노
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제4권1호
    • /
    • pp.135-139
    • /
    • 2002
  • In this study, the experimental open-tube and close-tube thermoacoustic apparatuses were built. In order to determine the optimum length of resonant tube and the optimum length of stack, the resonant characteristics of thermoacoustic apparatuses were investigated, The length of resonant tube varies from 400mm to 850mm. The experimental frequency varies from 100Hz to 1000Hz. In case of the second and third harmonics, the maximum temperature difference of open-tube thermoacoustic apparatus is 53$^{\circ}C$ (resonator length: 400mm) and the maximum temperature difference of closed-tube thermoacoustic apparatus is 51$^{\circ}C$ (resonator length: 500mm). In the open-tube thermoacoustic apparatus, the peak efficiency point is about 2%, 55%, 69% in the resonant tube and in the closed-tube thermoacoustic apparatus, the peak efficiency point is about 2%, 41%, 50% in the resonant tube.

슬롯관형 초음속 배기노즐의 공력소음에 관한 연구 (A Study on the Aerodynamic Noise of a Supersonic Exhaust Nozzle of Slotted Tube)

  • 이동훈;뢰호방총
    • 대한기계학회논문집B
    • /
    • 제24권1호
    • /
    • pp.132-142
    • /
    • 2000
  • The objective of this study is to experimentally investigate the noise propagating characteristics, the noise reduction mechanism and the performance of a slotted tube attached at the exit plane of a circular convergent nozzle. The experiment is performed through the systematic change of the jet pressure ratio and the slot length under the condition of two kinds of open area ratios, 25% and 51%. The open area ratio calculated by the tube length equivalent for the slot length is defined as the ratio of the total slot area to the surface area of a slotted tube. The experimental results for the near and far field sound, the visualization of jet structures and the static pressure distributions in the jet passing through a slotted tube are presented and explained in comparison with those for a simple tube. The propagating characteristics of supersonic jet noises from the slotted tube is closely connected with the slot length rather than the open area ratio, and its propagating pattern is similar to the simple tube. It is shown that the slotted tube has a good performance to suppress the shock-associated noise as well as the turbulent mixing noise in the range of a limited jet pressure and slot dimension. The considerable suppression of the shock‘associated noise is mainly due to the pressure relief caused by the high-speed jets passing through the slots on the tube. Both the strength of shock waves and the interval between them in a jet plume are decreased by the pressure relief. Moreover, the pressure relief is divided into the gradual and the sudden relief depending upon the open area ratio of the slotted tube. Consequently, the shock waves in a jet plume are also changed by the type of pressure relief. The gradual pressure relief caused by the slotted tube with the open area ratio 25% generates the weak oblique shock waves. On the contrary, the weak normal shock waves appear due to the sudden pressure relief caused by the slotted tube with the open area ratio 51%.

개방관형과 밀폐관형 열음향 냉동기의 1차 하모닉에 관한 특성 연구 (An Experimental Study on the 1st Harmonic Characteristic for open-tube-type and close-tube-type Thermoacoustic Refrigerators)

  • 송규조;박종호;고득용;박성제;김효봉;정철진
    • 한국초전도저온공학회:학술대회논문집
    • /
    • 한국초전도저온공학회 2002년도 학술대회 논문집
    • /
    • pp.189-192
    • /
    • 2002
  • In this study, The experimental open-tube-type and close-tube-type thermoacoustic refrigerator were constructed. The resonant characteristics of a thermoacoustic refrigerator were investigated. In order to determine the optimum resonant tube length and frequency, We changed the length of resonant tube from 400mm to 850mm and the frequency from 100Hz to 1000Hz. In case of first harmonic, the temperature difference of open-tube-type (1/4 wave) refrigerator was $41^{\circ}C$(resonator length :500mm). The temperature difference of close-tube-type (1/2 wave) refrigerator was $43^{\circ}C$(resonator length :850mm). In this experiments, the experimental 1/2 wave refrigerator is slightly cooler than the experimental l/4 wave refrigerator.

  • PDF

개방관과 밀폐관의 열음향 효과에 관한 하모닉 특성 연구(1) - 1차 하모닉 (An Experimental Study on the Characteristics for Open-Tube and Close-Tube Thermoacoustic Effects(1) - The 1st Harmonic)

  • 송규조;이성노
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제4권1호
    • /
    • pp.129-134
    • /
    • 2002
  • In this study, the experimental open-tube and close-tube thermoacoustic apparatuses were constructed. In order to determine the optimum length of resonant tube, frequency and the optimum length of stack, the resonant characteristics of thermoacoustic apparatuses were investigated, The length of resonant tube varies from 400mm to 850 mm. The experimental frequency varies from 100 Hz to 1000 Hz. In case of first harmonic, the maximum temperature difference of the open-tube thermoacoustic apparatus is 41$^{\circ}C$)resonator length: 500 mm), and the maximum temperature difference of the close-tube thermoacoustic apparatus is 42$^{\circ}C$ (resonator length : 850 mm).

분기관을 가진 연소 챔버 내 압력변동 특성에 관한 실험적 연구 (Experimental Study on the Characteristics of Pressure Fluctuation in the Combustion Chamber with Branch Tube)

  • 박장희;이대근;신현동
    • 대한기계학회논문집B
    • /
    • 제33권7호
    • /
    • pp.552-558
    • /
    • 2009
  • An experimental study using the combustor with branch tube was conducted in order to model the industry combustor with FGR (flue gas recirculation) system and to study a thermo-acoustic instability generated by a branch tube. The branch tube is a structure used to modify a system geometry and then to change its pressure field, and the thermo-acoustic instability, usually occurs in a confined geometry, can result in serious problems on industrial combustors. Thus understanding of the instability created by modifying geometry of combustor is necessary to design and operate combustor with FGR system. Pressure fluctuation in the combustion chamber was observed according to diameter and length of branch and it was compared with the solution of 1-D wave equation. It was found that branch tube affects the pressure field in the combustion chamber, and the pressure fluctuation in the combustion chamber was reduced to almost zero when phase difference between an incipient wave in the combustion chamber and a reflected wave in the branch tube is $\pi$ at the branch point. Also, the reduction of pressure fluctuation is irrespective of the installed height of branch tube if it is below $h^*=0.9$ in the close-open tube and open-open tube.

Propagation Characteristics of Compression Waves Reflected from the Open End of a Duct

  • Kim, Heuy-Dong;Lee, Dong-Hoon;H. Kashimura;T. Setoguchi
    • Journal of Mechanical Science and Technology
    • /
    • 제17권5호
    • /
    • pp.718-725
    • /
    • 2003
  • The present study addresses the distortion of the compression wave reflected from an open end of a shock tube. An experiment is carried out using the simple shock tube with an open end Computational work is also performed to represent the experimented flows. The second-order Total Variation Diminishing scheme is employed to numerically solve the unsteady, axisy-mmetric, inviscid, compressible governing equations. Both the experimented and predicted results are in good agreement. The generation and development mechanisms of the compression wave, which Is reflected from the open end of the shock tube, are obtained in detail from the present computations. The effect of size of the baffle plate at the open-end that causes the reflection of the incident expansion wave is found negligible. A good correlation is obtained for transition of the reflected compression wave to a shock wave inside the tube. The present data show that for a given wave length of the incident expansion wave the transition of the reflected compression wave to a shock wave can be predicted with good accuracy.

Enhancement of Re-closure Capacity by the Intra-amniotic Injection of Human Embryonic Stem Cells in Surgically Induced Spinal Open Neural Tube Defects in Chick Embryos

  • Lee, Gun-Soup;Lee, Do-Hun;Kim, Eun-Young;Wang, Kyu-Chang;Lee, Won-Don;Park, Sepill;Lim, Jin-Ho
    • 한국동물번식학회:학술대회논문집
    • /
    • 한국동물번식학회 2004년도 춘계학술발표대회
    • /
    • pp.275-275
    • /
    • 2004
  • To evaluate the potential of the stem cell therapy as a method for prenatal management of spinal open neural tube defect (ONTD), the influence of embryonic stem cells injected into the amniotic cavity on the re-closure capacity of spinal ONTD was investgated. Spinal neural tube was incised open for a length of 6 somites using chick embryos of Hamburger and Hamilton stage 18 or 19. (omitted)

  • PDF

Open-Tube에서 Zn확산을 이용한 GaAs에의 $p^+$층 형성 (Formation of $P^+-Layer$ in GaAs Using the Open-Tube Diffusion of Zn)

  • 심규환;강진영;민석기;한철원;최인훈
    • 대한전자공학회논문지
    • /
    • 제25권8호
    • /
    • pp.959-965
    • /
    • 1988
  • Zinc diffusion characteristics and its applicabilities have been studied using an open-tube system. Thermal decomposition of arsenide(As) at gallium arsenide(GaAs) wafer surface was well inhibited by using Ga: poly-GaAs: Zn compositon as a diffusion source. Junction depth was obtained as 4.6x10**7\ulcorner exp)-1.25/kT) where activation energy of diffusion was 1.25eV. From Boltzmann-matano analysis, it could be identified that concentration dependencies of Zn diffusivity well consisted with those of kick-out model. The ideality factor of p+-n junction formed by Zn diffusion was about 1.6 and infrared light intensity was linearly varied in the range of sixty folds. It is concluded frodm these results that Zn diffuses according to kick-out model, and open-tube method is applicable to compound semiconductor devices.

  • PDF

가스흡수식 냉온수기 열교환기용 세관의 부식특성에 관한 연구 (The Study on Corrosion Characteristics of Heat Exchanger Tube for Gas Absorption Refrigeration & Hot Water System)

  • 정기철
    • 한국가스학회지
    • /
    • 제6권1호
    • /
    • pp.92-97
    • /
    • 2002
  • 가스흡수식 냉온수기의 작동매체로 사용되고 있는 LiBr 수용액 중에서 열교환기 세관용 재료인 동 세관 및 동합금재인 큐프로니켈 세관의 부식특성에 관한 연두를 하기 위하여 $62\%$ LiBr 수용액 중에서 각 재료에 대한 전기화학적 분극실험을 실시하여 부식특성을 고찰한 결과 다음과 같은 결론을 얻었다 1) 열교환기 세관재의 분극저항은 $30\%$ 큐프로니켈 세관 > $10\%$ 큐프로니켈 세관 > 동 세관의 순으로 높게 나타난다 2) 큐프로니켈 세관의 개로전위는 동 세관보다 귀전위화되면서 부식전류밑도는 더 억제된다 3) $30\%$ 큐프로니켈 세관의 부동태 영역은 $10\%$ 큐프로니켈 세관보다 전위구간이 더 크게. 나타나면서 부동태유지 전류밀도는 더 낮아진다.

  • PDF