• Title/Summary/Keyword: Open-phase faults

Search Result 44, Processing Time 0.021 seconds

Fault Tolerant Control Methods for Dual Type Independent Multi-Phase BLDC Motor under the Open-Switch Fault Conditions

  • Kim, Yong-Hyu;Heo, Hong-Jun;Park, June-Ho;Kim, Jang-Mok
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.2
    • /
    • pp.722-732
    • /
    • 2018
  • Dual type Independent multi-phase BLDC Motor (DI-BLDCM) is designed to be robust to faulty conditions of motor and drive system. Despite the efforts of the motor design, open-switch faults of DI-BLDCM drive system cause the torque ripple of the motor. This torque ripple makes unwanted sound noise and mechanical vibration of associated systems. This paper proposes four methods for compensating the torque ripple and compares the characteristics of each proposed method. All proposed methods are able to reduce the torque ripple to similar level of the healthy condition, although the motor operates in open-switch fault conditions. However, these methods have different characteristics in various fault conditions. Therefore, from the results of the comparison, the suitable method is selected for the various fault conditions. The feasibility of the proposed methods is proved by the several experimental results.

Open Circuit Fault Diagnosis Using Stator Resistance Variation for Permanent Magnet Synchronous Motor Drives

  • Park, Byoung-Gun;Kim, Rae-Young;Hyun, Dong-Seok
    • Journal of Power Electronics
    • /
    • v.13 no.6
    • /
    • pp.985-990
    • /
    • 2013
  • This paper proposes a novel fault diagnosis scheme using parameter estimation of the stator resistance, especially in the case of the open-phase faults of PMSM drives. The stator resistance of PMSMs can be estimated by the recursive least square (RLS) algorithm in real time. Fault diagnosis is achieved by analyzing the estimated stator resistance of each phase according to the fault condition. The proposed fault diagnosis scheme is implemented without any extra devices. Moreover, the estimated parameter information can be used to improve the control performance. The feasibility of the proposed fault diagnosis scheme is verified by simulation and experimental results.

Fault Diagnosis of Solar Power Inverter Using Characteristics of Trajectory Image of Current And Tree Model (전류 궤적 영상의 특징과 트리모델을 이용한 태양광 전력 인버터의 고장진단)

  • Hwang, Jae-Ho
    • Journal of the Institute of Electronics Engineers of Korea CI
    • /
    • v.47 no.4
    • /
    • pp.102-108
    • /
    • 2010
  • The photovoltaic system changes solar energy into DC by solar cell and this DC is inverted into AC which is used in general houses by inverter. Recently, the use of power of the photovoltaic system is increased. Therefore, the study of 3 phase solar system to transmit large power is very important. This paper proposes a method that finds simply faults and diagnoses the switch open faults of 3-phase pulse width modulation (PWM) inverter of grid-connected photovoltaic system. The proposed method in $\alpha\beta$ plane uses the patterns of trajectory image as the characteristic parameters and differenciates a normal state and open states of switches. Then, the result is made into tree. The tree is composed of 21 fault patterns and the parameters to classify faults are a shape, a trajectory area, a distributed angle, and a typical vector angle. The result shows that the proposed method diagnosed fault diagnoses, classified correctly them, and made a pattern tree by fault patterns.

Novel Average Value Model for Faulty Three-Phase Diode Rectifier Bridges

  • Rahnama, Mehdi;Vahedi, Abolfazl;Alikhani, Arta Mohammad;Nahid-Mobarakeh, Babak;Takorabet, Noureddine
    • Journal of Power Electronics
    • /
    • v.19 no.1
    • /
    • pp.288-295
    • /
    • 2019
  • Rectifiers are widely used in industrial applications. Although detailed models of rectifiers are usually used to evaluate their performance, they are complex and time-consuming. Therefore, the Average Value Model (AVM) has been introduced to meet the demand for a simple and accurate model. This type of rectifier modeling can be used to simplify the simulations of large systems. The AVM of diode rectifiers has been an area of interest for many electrical engineers. However, healthy diode rectifiers are only considered for average value modeling. By contrast, faults occur frequently on diodes, which eventually cause the diodes to open-circuit. Therefore, it is essential to model bridge rectifiers under this faulty condition. Indeed, conventional AVMs are not appropriate or accurate for faulty rectifiers. In addition, they are significantly different in modeling. In this paper, a novel application of the parametric average value of a three-phase line-commutated rectifier is proposed in which one diode of the rectifier is considered open-circuited. In order to evaluate the proposed AVM, it is compared with experimental and simulation results for the application of a brushless synchronous generator field. The results clearly demonstrate the accuracy of the proposed model.

Low-Cost Fault Diagnosis Algorithm for Switch Open-Damage in BLDC Motor Drives

  • Park, Byoung-Gun;Lee, Kui-Jun;Kim, Rae-Young;Hyun, Dong-Seok
    • Journal of Power Electronics
    • /
    • v.10 no.6
    • /
    • pp.702-708
    • /
    • 2010
  • In this paper, a fault diagnosis algorithm for brushless DC (BLDC) motor drives is proposed to maintain control performance under switch open-damage. The proposed fault diagnosis algorithm consists of a simple algorithm using measured phase current information and it detects open-circuit faults based on the operating characteristic of BLDC motors. The proposed algorithm quickly recovers control performance due to its short detection time and its reconfiguration of the system topology. It can be embedded into existing BLDC drive software as a subroutine without additional sensors. The feasibility of the proposed fault diagnosis algorithm is proven by simulation and experimental results.

Switch Open Fault Diagnosis of Inverter Using Features of dq Currents (dq 전류의 특징을 이용한 인버터의 스위치 개방 고장진단)

  • Kwak, Nae-Joung;Hwang, Jae-Ho;Hong, Won-Pyo
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.48 no.1
    • /
    • pp.31-38
    • /
    • 2011
  • Faults of motor drive systems to be used for various industrial applications can cause serious problems. In this paper, a method to diagnose switch open fault of a voltage-fed PWM inverter is proposed. The proposed method normalizes dq current and fault-detection and first classification are performed by mean values of dq phase currents, second classification is performed by features such as the relation of dq phase currents, the ranges of those, the positions of those according to the results, and fault switch is diagnosed with the results. The proposed method performs the simulation for diagnosis of inverter switch open faults with MATLAB and identifies the feasibility of the proposed method. Because the proposed method is implemented by simple algorithms, the proposed algorithm can be embedded in general induction motor drive systems and be used.

A Study on Device Development for Electrical Fire Protection on Open Phase of Three-Phase Motor (3상 전동기 결상에 의한 전기화재 보호를 위한 장치 개발 연구)

  • Choi, Shin-Hyeong;Kwak, Dong-Kurl;Kim, Jin-Hwan
    • Fire Science and Engineering
    • /
    • v.26 no.1
    • /
    • pp.61-67
    • /
    • 2012
  • In the three-phase power system using the three-phase motor, when any one-phase is open-phase, the unbalanced current flows and the single-phase power supplied by power supply produces overcurrent to motor coil. As a result, the enormous damage and electrical fire can be given to the power system. Recently, the thermal over-current relay (THR) or electronic motor protection relay (EMPR) is mostly used as the open-phase detection device of the three-phase motor. When the over-current or overheat of electric line is generated, it detects and operates circuit breaker, but there is the defect that the sensing speed is slow, the operation can be sometimes failed, and the precision is decreased. In order to improve these problems, this paper is proposed a new control circuit topology for openphase protection using semiconductor devices. Therefore, the proposed open-phase protection device (OPPD) enhances the sensing speed and precision, and has the advantage of simple fitting in the three-phase motor control panel in the field, as it manufactures into small size and light weight. As a result, the proposed OPPD protects the three-phase motor, minimizes the electrical fire from openphase, and contributes for the stable driving of the power system. The performance and confidence of the proposed OPPD is confirmed by a great variety of the experiments of operation characteristic.

Digital Negative Sequence Relay Algorithm for Detection of Unbalanced State in a Generator (발전기의 불평형 검출을 위한 디지털 역상 계전 알고리즘)

  • Park, Chul-Won
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.62 no.4
    • /
    • pp.198-203
    • /
    • 2013
  • There are conditions that can be unbalanced three phase currents in a large generator by untransposed lines, unbalanced loads, unsymmetrical faults, and open phases. The unbalanced conditions can producing negative sequence components of current that induce two times frequence current in the surface of the rotor, the retaining rings, the slot wedges in the field windings. These rotor currents make the rotor rapidly overheat, so the rotor can cause substantial damage in a very short time. This paper presents the digital negative sequence relay algorithm for unbalanced protection in a generator. The proposed algorithm was tested by using collected current signals on PSCAD/EMTDC considering a hydro turbine based generator control system. It can be seen that the proposed relaying by negative sequence current is useful for detection of unbalanced state of large generator.

Analysis of Transient Characteristics of a SFCL Applied Into Third-winding Transformer in a Single Line-to-ground Fault (1선 지락 사고 시 3 권선 변압기에 적용된 초전도 한류기의 동작 특성 분석)

  • Choi, Hye-Won;Choi, Hyo-Sang;Jung, Byung-Ik
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.7
    • /
    • pp.1033-1037
    • /
    • 2013
  • Coercion transformer is commonly used in the electrical grid which in three phase of distribution system. The accident of the electrical grid is divided into a single, a double, a third line-to-ground faults and a double, a third line-to-line faults. A single line-to-ground fault accounts for nearly 75[%] among them. In this research, when a Superconducting Fault Current Limiters (SFCL) was applied to the three phase power system, operation in a single line-to-ground fault and limiting characteristics of fault current according to turns ratio of third winding were analyzed. When a single line-to-ground fault happened, secondary winding's circuit was open. Then third winding's circuit with a SFCL was closed. So fault current was limited by diverted circuit. At this time, we could find out that size of the limited fault current could be changed according to third winding rate. We confirmed that limiting operation of the fault current was carried out within one-period. These results will be utilized in adjusting the size of the SFCL.

Fault Detection and Classification with Optimization Techniques for a Three-Phase Single-Inverter Circuit

  • Gomathy, V.;Selvaperumal, S.
    • Journal of Power Electronics
    • /
    • v.16 no.3
    • /
    • pp.1097-1109
    • /
    • 2016
  • Fault detection and isolation are related to system monitoring, identifying when a fault has occurred, and determining the type of fault and its location. Fault detection is utilized to determine whether a problem has occurred within a certain channel or area of operation. Fault detection and diagnosis have become increasingly important for many technical processes in the development of safe and efficient advanced systems for supervision. This paper presents an integrated technique for fault diagnosis and classification for open- and short-circuit faults in three-phase inverter circuits. Discrete wavelet transform and principal component analysis are utilized to detect the discontinuity in currents caused by a fault. The features of fault diagnosis are then extracted. A fault dictionary is used to acquire details about transistor faults and the corresponding fault identification. Fault classification is performed with a fuzzy logic system and relevance vector machine (RVM). The proposed model is incorporated with a set of optimization techniques, namely, evolutionary particle swarm optimization (EPSO) and cuckoo search optimization (CSO), to improve fault detection. The combination of optimization techniques with classification techniques is analyzed. Experimental results confirm that the combination of CSO with RVM yields better results than the combinations of CSO with fuzzy logic system, EPSO with RVM, and EPSO with fuzzy logic system.