• Title/Summary/Keyword: Open-loop starting

Search Result 10, Processing Time 0.029 seconds

Rotor Initial Polarity Detection Method of Single-Phase PMSM Considering Asymmetric Air-Gap Structure (단상 영구자석 동기 전동기의 비대칭 공극 구조를 고려한 회전자 초기 자극 검출 기법)

  • Seo, Sung-Woo;Hwang, Seon-Hwan;Park, Jong-Won;Kim, Yong-Hyu
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.27 no.1
    • /
    • pp.80-83
    • /
    • 2022
  • This paper proposes an initial rotor polarity detection algorithm of a single-phase permanent magnet synchronous motor (SP-PMSM) related to stable open-loop starting for sensorless operation. Generally, the SP-PMSM needs an asymmetric air-gap structure to can avoid the initial starting failure at zero torque point. Therefore, the rotor polarity information can be obtained by using the DC offset current direction of a stator current through a high frequency voltage injection into an SP-PMSM with an asymmetric air gap. In this paper, the proposed rotor initial polarity detection algorithm is verified through several experimental results.

A Study on Startup-Characteristic of Sensorless Controlled IPMSM Employing Sliding Mode Observer (슬라이딩 모드 관측기를 이용한 IPMSM의 센서리스 제어의 기동특성에 관한 연구)

  • Kim, Sang-Hun;Kwon, Soon-Jae;Kim, Marn-Go;Jung, Young-Seok
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.16 no.1
    • /
    • pp.38-43
    • /
    • 2011
  • This paper presents the improvement of start-up characteristic of sensorless controlled IPMSM(Interior Permanent Magnet Synchronous Motor) with SMO(Sliding Mode Observer). It is difficult to utilize the rotor position information at starting point for the back EMF estimation based sensorless control. For this reason, open loop control is normally used during start-up period. However, changing from open loop to closed loop control might bring a problem on the transient characteristics for difference load conditions. To solve this problem, we add another rotor angle controller. Simulation results and experimental results are presented to verify proposed method.

A Heuristic Approach for Grading Operation of Hydraulic Excavator Systems using SMISMO Valve Configuration (SMISMO 밸브 구조를 채용한 유압식 굴삭기의 평탄화 작업을 위한 휴리스틱 접근)

  • Joh, Joongseon;Hwang, Cheol Min
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.30 no.11
    • /
    • pp.1153-1160
    • /
    • 2013
  • SMISMO valve configuration is now starting to draw attention of the researchers of the construction equipment industry to increase the fuel efficiency of their equipment like excavators and wheel-loaders. An open-loop control strategy for grading operation of hydraulic excavator systems using SMISMO valve configuration is investigated in this paper. Tabor's algorithm for 1 d.o.f. SMISMO system under the assumption of quasi-static operation is revealed as not adequate for multi d.o.f. system with large moment of inertia even though the motion of the system is slow. New parameters are proposed in this paper. It modifies Tabor's open-loop control strategy for the grading operation of hydraulic excavators using SMISMO valve configuration. A simulation-based parameter tuning method is also proposed. It uses GA (Genetic Algorithm) to find the best parameter values. Simulation study for a practical hydraulic excavator shows the validity of the proposed open-loop control strategy.

Sensorless Starting of Direct Drive Horizontal Axis Washing Machines

  • Dianov, Anton;Kim, Nam Su;Lim, Seung Moo
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • v.3 no.2
    • /
    • pp.148-154
    • /
    • 2014
  • This paper describes problems of the sensorless starting of horizontal axis washing machines with direct drive and suggests solution, which was experimentally verified. Horizontal axis washing machines have very difficult conditions for the drive starting, especially at full load. Inertia of the tub and water, torque from the laundry make load torque at starting higher than rated one and sometimes even higher than the maximum torque of the motor, which makes sensorless starting extremely challenging task. This paper suggests modified open-loop starting, where control system is closed shortly after beginning at low speed and rotates the drum until laundry restructuring. To ensure proper work of the sensorless algorithm at low speed additional measures for increasing of the estimation algorithm performance have been taken. These measures include special algorithm for the drive parameters estimation, which has been developed and verified by the experimental results.

Starting Characteristic Analysis of a Slotless type Permanent Magnet Linear Synchronous Motor using 3-D Space Harmonic Method (3차원 공간고조파법을 이용한 슬롯리스형 영구자석 선형 동기 전동기의 기동특성 해석)

  • An, Ho-Jin;Gang, Gyu-Hong;Kim, Gyu-Taek
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.51 no.7
    • /
    • pp.379-386
    • /
    • 2002
  • This paper deals with dynamic analysis method of a slotless type permanent magnet linear synchronous motor(PMLSM) using 3-dimensional space harmonic method. The results are good agreement with FEA results because that slotless type PMLSM has simple structure and no saturation of core. And then, Under open-loop control, starting characteristic is analyzed by voltage equation combining with dynamic equation. In order to obtain more accuracy results, this paper use instantaneous back-EMF and thrust instead of back-EMF constant and thrust constant.

Time-optimal multistage controllers from the theory of dynamical cell-to-cell mappings

  • Yoon, Joong-Sun
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1989.10a
    • /
    • pp.118-123
    • /
    • 1989
  • This work deals with fast-to-compute global control laws for time-optimal motion of strongly nonlinear dynamic systems like resolute robots. the theory of cell-to-cell mappings for dynamical systems offer the possibility of doing the vast majority of the control law computation offline in case of time optimization with constrained inputs. These cells result from a coarse discretization of likely swaths of state space into a set of nonuniform, contiguous volumes of relatively simple shapes. Once the cells have been designed, the bang-bang schedules for the inputs are determined for all likely starting cells and terminating cells. the resulting control law is an open-loop optimal control law with feedback monitoring and correction.

  • PDF

Sensorless Transition Algorithm of PM Synchronous Motor by Load Torque Estimation (영구자석동기전동기의 부하추정을 통한 센서리스 전환 알고리즘)

  • Kim, Dong-Hyun;Cho, Kwan-Yuhl;Kim, Hag-Wone
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.26 no.5
    • /
    • pp.349-356
    • /
    • 2021
  • Permanent magnet synchronous motors are mainly used in the traction of electric vehicle and home application products including air-conditioners and refrigerators. For sensorless control without rotor position sensors, I-F control is applied for initial starting at low speeds, and mode is changed to sensorless control when the rotor speed is sufficiently accelerated for estimating rotor position. When the mode is changed to the sensorless control from the open-loop starting, the initial integral value of the speed controller should be considered by load condition; otherwise, the transition to sensorless control may fail. The sensorless transfer algorithm of PM synchronous motor based on load condition for smooth transition is proposed. The performance of the proposed sensorless transfer algorithm was verified by experiments.

Initial Rotor Polarity Detection of Single-phase Permanent Magnet Synchronous Motor Based on Virtual dq-axis (단상 영구자석 동기 전동기의 가상 dq축 기반 초기 회전자 자극 검출)

  • Seo, Sung-Woo;Hwang, Seon-Hwan;Lee, Ki-Chang
    • Journal of IKEEE
    • /
    • v.24 no.4
    • /
    • pp.1004-1010
    • /
    • 2020
  • This paper proposes an initial rotor magnetic pole detection method for single-phase permanent magnet synchronous motors. The target motor cannot obtain position information based on the back emf in the low speed and stop state. Therefore, an open loop starting process is required, and in this process, initial rotor position information for low current and soft start is need. The proposed initial rotor magnetic pole detection algorithm considers the effect of asymmetric air- gap and magnetic flux. In addition, the high-frequency voltage signal injection and the offset voltage for accurate detection is used. As a result, the permanent magnet poles are is determined by acquiring the maximum value of the induced current using the virtual dq-axis.

Square Wave Voltage Injection Starting Method of SP-PMSM Considering Nonlinearity of Full-bridge Inverter (풀 브릿지 인버터의 비선형성을 고려한 단상 영구자석 동기 전동기의 구형파 전압 주입 기동 기법)

  • Yoo, Sang-Min;Hwang, Seon-Hwan;Lee, Ki-Chang
    • Journal of Aerospace System Engineering
    • /
    • v.16 no.3
    • /
    • pp.93-98
    • /
    • 2022
  • The purpose of this paper was to propose a method for improving the performance of the open-loop control of single-phase permanent magnet synchronous motor (SP-PMSM), based on a square wave voltage injection. Generally, the SP-PMSM driving systems cmprise a full-bridge inverter and asymmetric air-gap structure of magnetic circuit, because a zero torque occurs on the symmetrical air-gap. As a result, it cannot be started at a specific rotor position. Thus, it is possible to cause the start-up failure at an open-loop control for sensorless operation of SP-PMSM. In this paper, the method with square wave voltage injection considering the nonlinearity of the inverter is presented to resolve the problem. The effectiveness of the proposed algorithm is verified through several experiments.

A Study on Rotor Polarity Detection of SP-PMSM Using Offset Current Based on Current Control (전류 제어 기반 옵셋 전류를 이용한 단상 영구자석 동기 전동기의 회전자 자극 검출에 관한 연구)

  • Park, Jong-Won;Hwang, Seon-Hwan
    • Journal of IKEEE
    • /
    • v.23 no.3
    • /
    • pp.1020-1026
    • /
    • 2019
  • In this paper, a rotor polarity detection algorithm is proposed to control the single-phase permanent magnet synchronous motors(SP-PMSMs) for high speed sensorless operation. Generally, the sensorless control of a SP-PMSM is switched to the sensorless operation in a specific speed region after the open loop startup. As a result, it is necessary to detect the rotor polarity to maintain a constant rotational direction of the SP-PMSM at the starting process. There, this paper presents a novel rotor polarity detection method using a high frequency voltage signal and offset current which is generated by current regulator. The proposed algorithm verified the effectiveness and usefulness of the rotor polarity detection through several experiments.