• Title/Summary/Keyword: Open-loop

Search Result 852, Processing Time 0.022 seconds

The Implementation and Experiments of Open-Loop Cylindrical Vibratory Gyroscope (개루프 제어의 실린더 진동형 자이로 구현 및 실험)

  • 공형직;김정엽;홍성경
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.10 no.8
    • /
    • pp.669-672
    • /
    • 2004
  • This paper considers the implementation and experiments of an open-loop Cylindrical Vibratory Gyroscope(CGV). An open-loop CGV composed of thin cylindrical vibrating element, electromagnetic drive and pick-off element with open-loop control was designed and fabricated. The experimental performance tests of the open-loop CGV were done using a temperature chambered rate table. Also, the limitations of open-loop CGV were analyzed and the solution for the limitations was proposed.

Multibody Dynamics of Closed, Open, and Switching Loop Mechanical Systems

  • Youm, Youn-Gil
    • Journal of Mechanical Science and Technology
    • /
    • v.19 no.spc1
    • /
    • pp.237-254
    • /
    • 2005
  • The vast mechanical systems could be classified as closed loop system, open loop system and open & closed (switching) system. In the closed loop system, the kinematics and dynamics of 3-D mechanisms will be reviewed and closed form solutions using the direction cosine matrix method and reflection transformation method will be introduced. In the open loop system, kinematic & dynamic analysis methods regarding the redundant system which has more degrees of freedom in joint space than those of task space are reviewed and discussed. Finally, switching system which changes its phase between closed and open loop motion is investigated with the principle of dynamical balance. Among switching systems, the human gait in biomechanics and humanoid in robotics are presented.

Open loop resonator diplexer applying conjugate matching (복소 매칭을 이용한 Open Loop Resonator 다이플렉서)

  • Paek, Hyun;Han, Hyeong-Seok;Kim, Hyeong-Seok
    • 한국정보통신설비학회:학술대회논문집
    • /
    • 2008.08a
    • /
    • pp.425-428
    • /
    • 2008
  • A new type of cross-coupled planar microwave filter using coupled microstrip square open-loop resonators diplexer pro-posed. A method for the rigorous calculation of the coupling coefficients of basic four pole electric and magnetic coupling structures encountered. Simple empirical models are derived for estimation of the coupling coefficients. Experiments are performed to verify the theory. And a method for diplexer matching is conjugate matching that has characteristic better than open matching method.

  • PDF

Closed-loop Sheet Metal Forming Using Dieless Forming Apparatus (무금형 성형장치를 이용한 폐루프 판재성형)

  • 양승훈;박종우;홍예선;양현석
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2002.05a
    • /
    • pp.62-65
    • /
    • 2002
  • A dieless forming system which consists of hydraulic punch elements and elastomer/fluid pads, was developed for sheet metal forming. 2-D curved surface forming was carried out using open-loop, closed-loop, and repeated forming method. Closed-loop exhibited higher decision than open-loop forming. Repeated forming also showed reduced spring back and possibility of high precision.

  • PDF

Open-Loop Control of Combustion Instability in Hot-Firing Test Using Gaseous Hydrocarbon Fuel (기체 탄화수소 연료 연소시험에서 연소불안정의 개루프 제어)

  • Hwang, Donghyun;Ahn, Kyubok
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.22 no.6
    • /
    • pp.28-36
    • /
    • 2018
  • A study was conducted to apply open-loop control to the combustion instability in a dump combustor using gaseous hydrocarbon fuels. Control power and frequency were varied by employing a loudspeaker under combustion conditions with similar characteristic chemistry times of the fuels. In the case of open-loop control where the frequency was identical to the combustion instability frequency, the open-loop control power affected the control performance. Results obtained from conducted open-loop control tests, where the frequency was different from the combustion instability frequency, show that setting the open-loop control frequency similar to the combustion instability frequency is effective.

A STUDY ON THE CHANGES OF THE ELASTIC PROPERTIES TN LOOPED WIRES BY VARIABLE FACTORS (변환요소에 따른 LOOPED WIRE의 탄성 변화에 관한 연구)

  • Na, Yong-In;Kim, Sang-Cheol
    • The korean journal of orthodontics
    • /
    • v.25 no.3 s.50
    • /
    • pp.263-271
    • /
    • 1995
  • The purpose of this study nab to evlauate and compare the effect of the variable factors of wire on the elastic properties of looped rectangular wire. Five variable factors were presented-material(Hi-T, blue Elgiloy), wire size(.016'$\;\times\;$.022', .018'$\;\times\;$.025'), loop length(15mm, 20mm), loop configuration(open loop, closed loop), gabling (non-gable, gable). So, the total 256 specimens were divided into 32 groups, and each of those nab pulled on Instron testing machine. The load-deflection curve of each wire obtained, from which force, range in elastic limit, and stiffness were computed and analyzed statistically. The results were obtained as follows : 1. All of the variable factors - wire material, size, loop length loop configuration, and gabling - took a significant effect on load-deflection rate of looped wire. 2. The force at elastic limit was the smallest in the group of Hi-T, .016'$\;\times\;$.022', 20mm loop length, open loop, non-gable, and the largest in the group of blue Elgiloy, .018'$\;\times\;$.025', 15mm loop length, closed loop, non-gable. 3. The range at elastic limit was the smallest in the group of Hi-T, .018'$\;\times\;$.025', 15mm loop length, open loop, non-gable, and the largest in the group of HI-T, .016'$\;\times\;$.022', 20mm loop length, closed loop, gable. 4. Loop configuration and loop length were the most effective factors on the elastic properties of looped wires, and gabling was the least effective.

  • PDF

Microstrip Slow-Wave Open-Loop Resonator Filters with Reduced Size and Improved Stopband Characteristics

  • Akkaraekthalin, Prayoot;Jantree, Jaruek
    • ETRI Journal
    • /
    • v.28 no.5
    • /
    • pp.607-614
    • /
    • 2006
  • This paper presents a new class of microstrip slow-wave open-loop resonator filters with reduced size and improved stopband characteristics. A comprehensive treatment of both ends loaded with triangular and rectangular ends is described, leading to the invention of a microstrip slow-wave open-loop resonator. Two-resonator and four-resonator bandpass filters are designed at the operating frequency of about 2 GHz, and a bandwidth of 60 MHz. The size of the slow-wave open-loop resonator is optimized from the standpoint of the unloaded Q-factor. The filters are not only compact in size due to the slow-wave effect, but also have a wider upper stopband resulting from the dispersion effect. The filter designs of this type are described in details. The experimental results are demonstrated and discussed.

  • PDF

An Open-Loop Method for Point-to-Point Positioning of a Piezoelectric Actuator

  • Henmi, Nobuhiko;Tanaka, Michihiko
    • International Journal of Precision Engineering and Manufacturing
    • /
    • v.8 no.2
    • /
    • pp.9-13
    • /
    • 2007
  • We describe how to control a piezoelectric actuator using the open-loop method for point-to-point positioning. Since piezoelectric actuators have nonlinear characteristics due to hysteresis and creep between the input voltage and the resulting displacement, a special method is required to eliminate this nonlinearity for an open-loop drive. We have introduced open-loop driving methods for piezoelectric actuators in the past, which required a large input voltage and an initializing motion sequence to reset the state of the actuator before each movement. In this paper, we propose a new driving method that uses the initializing state. This method also utilizes the overshoot from both the upward and downward stepwise drives. Applying this method., we obtained precise point-to-point positioning without the influence of hysteresis and creep.

Development of a full-scale magnetorheological damper model for open-loop cable vibration control

  • Zhang, Ru;Ni, Yi-Qing;Duan, Yuanfeng;Ko, Jan-Ming
    • Smart Structures and Systems
    • /
    • v.23 no.6
    • /
    • pp.553-564
    • /
    • 2019
  • Modeling of magnetorheological (MR) dampers for cable vibration control to facilitate the design of even more effective and economical systems is still a challenging task. In this study, a parameter-adaptive three-element model is first established for a full-scale MR damper based on laboratory tests. The parameters of the model are represented by a set of empirical formulae in terms of displacement amplitude, voltage input, and excitation frequency. The model is then incorporated into the governing equation of cable-damper system for investigation of open-loop vibration control of stay cables in a cable-stayed bridge. The concept of optimal voltage/current input achieving the maximum damping for the system is put forward and verified. Multi-mode suboptimal and Single-mode optimal open-loop control method is then developed. Important conclusions are drawn on application issues and unique characteristics of open-loop cable vibration control using MR dampers.

A Study of the Influence of Groundwater Level on the System Performance of Open Loop Geothermal System (지하수 수위가 개방형 지열시스템 성능에 미치는 영향에 관한 연구)

  • Kim, Jinsang;Nam, Yujin
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.9 no.3
    • /
    • pp.1-10
    • /
    • 2013
  • Open loop geothermal heat pumps have great potential where the groundwater resources are sufficient. Performance of open loop geothermal heat pump systems is considered higher than that of ground source heat pumps. Head and power calculation of submersible pumps, heat pump units, and piping are numerically based on regression data. Results shows that the system performance drops as the water level drops, and the lowest flow rates generally achieve the highest system COPs. The highest achievable cooling system COPs become 6.34, 6.12, and 5.95 as the groundwater levels are 5m, 15m, and 25m. The highest heating system COPs also become 4.59, 4.37, and 4.20. Groundwater level and submersible pump selection greatly influence the system performance of open loop geothermal heat pumps. It needs to be analysed during the design process of open loop geothermal heat pump system, possibly with analysis tools that include wide range of pump product data.