• Title/Summary/Keyword: Open-Circuit Characteristics

Search Result 281, Processing Time 0.027 seconds

Operating Temperature Characteristics of Amorphous Silicon Solar Cells (비정질(非晶質) 실리콘 태양전지(太陽電池)의 동작온도(動作溫度) 특성(特性))

  • Han, Min-Koo
    • Solar Energy
    • /
    • v.7 no.1
    • /
    • pp.30-34
    • /
    • 1987
  • Experimental results are discussed concerning temperature effects from $25^{\circ}C$ to $100^{\circ}C$ on amorphous silicon solar cells. N-I-P hydrogenated amorphous silicon solar cells are fabricated on stainless steel and indium tin oxide glass substrates. The open circuit voltage, short circuit current, fill factor and conversion efficiency have been measured under AM1 condition as a function of temperature. The open circuit voltage decreased by $2.6mV/^{\circ}C$ while the short circuit current increases with increased temperature. The conversion efficiency is almost independent of temperature which is contrary to widely using single crystalline solar cells of which efficiencies decrease with increasing temperature.

  • PDF

An Experimental Study on the Heat Transfer Characteristics of the Conversion Efficiency in the Concentrated Photovoltaic Cells (방열 특성에 따른 집광형 태양전지의 광전변환효율 변화에 관한 실험적 연구)

  • Kim, Kangho;Jung, Sang Hyun;Kim, Youngjo;Kim, Chang Zoo;Jun, Dong Hwan;Shin, Hyun-Beom;Lee, Jaejin;Kang, Ho Kwan
    • Current Photovoltaic Research
    • /
    • v.2 no.4
    • /
    • pp.168-172
    • /
    • 2014
  • Under concentrated illuminations, the solar cells show higher efficiencies mainly due to an increase of the open circuit voltage. In this study, InGaP/InGaAs/Ge triple-junction solar cells have been grown by a low pressure metalorganic chemical vapor deposition. Photovoltaic characteristics of the fabricated solar cells are investigated with a class A solar simulator under concentrated illuminations from 1 to 100 suns. Ideally, the open circuit voltage should increase with the current level when maintained at the same temperature. However, the fabricated solar cells show degraded open circuit voltages under high concentrations around 100 suns. This means that the heat sink design is not optimized to keep the cell temperature at $25^{\circ}C$. To demonstrate the thermal degradation, changes of the device performance are investigated with different bonding conditions and heat sink materials.

Power Generation Properties and Bending Characteristics of a Flexible Thermoelectric Module Fabricated using PDMS Filling Method (PDMS 충진법을 이용하여 형성한 유연열전모듈의 발전특성과 굽힘특성)

  • Han, Kee Sun;Oh, Tae Sung
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.26 no.4
    • /
    • pp.119-126
    • /
    • 2019
  • A flexible thermoelectric module, which consisted of 18 pairs of Bi2Te3-based hot-pressed p-n thermoelectric legs, were processed by filling the module inside with polydimethylsiloxane (PDMS) and removing the top and bottom substrates. Its power generation properties and bending characteristics were measured. With putting the flexible module on the wrist, an open circuit voltage of 2.23 mV and a maximum output power of 1.69 ㎼ were generated during staying still. On the other hand, an open circuit voltage of 3.32 mV and a maximum output power of 3.41 ㎼ were obtained with walking motion. The resistance variation of the module was kept below 1% even after applying 30,000 bending cycles with a bending curvature radius of 25 mm.

RF Characteristics of Open Stubs on PES Substrate for Application to Capacitive Matching Components on Flexible MMIC

  • Yun, Young;Jeong, Jang-Hyeon;Kim, Hong-Seung;Jang, Nak-Won
    • Transactions on Electrical and Electronic Materials
    • /
    • v.16 no.3
    • /
    • pp.142-145
    • /
    • 2015
  • In this work, open stubs were fabricated on a polyether sulfone (PES) substrate, and their basic radio frequency (RF) characteristics were investigated for application to RF matching components of a flexible monolithic microwave integrated circuit (MMIC). According to the results, an open stub employing coplanar waveguide (OSCPW) on PES exhibited much lower loss than that on silicon substrate. The OSCPW with a length of $500{\mu}m$ on PES showed capacitance values of 0.031 ~ 0.044 pF from 0.5 to 50 GHz. For application to a relatively high-value capacitive matching, an open stub employing a fishbone-type transmission line (OSFTTL) was fabricated on PES, and its characteristics were investigated. The OSFTTL showed much higher capacitance values than the OSCPW due to the high effective permittivity value. Specifically, the OSFTTL on PES showed capacitance values of 0.066 ~ 0.24 pF from 0.5 to 50 GHz, which are higher than those for the open stub on silicon substrate. The above results indicate that the OSCPW and OSFTTL on PES can be effectively used for application to low/high-value capacitive matching components on microwave and millimeter wave flexible MMIC. To the best of the authors' knowledge, this work is the first report of the investigation of RF capacitive matching components on PES substrate.

Study for the Operational Characteristics of Closed Circuit Hydraulic System of Turnover-Type Sluice Gate (전도 수문용 폐회로형 유압장치의 작동 특성에 관한 연구)

  • Lee, Seong-Rae
    • Proceedings of the KSME Conference
    • /
    • 2007.05a
    • /
    • pp.897-902
    • /
    • 2007
  • The turnover-type sluice gate is typically actuated by the open circuit hydrauic system since the single-rod cylinder is used rather than the double-rod cylinder. However, here the closed circuit hydrauic system is applied for the operation of turnover-type sluice gate for the purpose of convenient operation. The closed circuit hydraulic system of turnover-type sluice gate is composed of a bi-directional pump, single-rod cylinders, pilot operated check valves, check valves and a counter balance valve. The usefulness of the closed circuit hydraulic system is verified for the several operational conditions by the computer simulations.

  • PDF

Design, Analysis, and Equivalent Circuit Modeling of Dual Band PIFA Using a Stub for Performance Enhancement

  • Yousaf, Jawad;Jung, Hojin;Kim, Kwangho;Nah, Wansoo
    • Journal of electromagnetic engineering and science
    • /
    • v.16 no.3
    • /
    • pp.169-181
    • /
    • 2016
  • This work presents a new method for enhancing the performance of a dual band Planer Inverted-F Antenna (PIFA) and its lumped equivalent circuit formulation. The performance of a PIFA in terms of return loss, bandwidth, gain, and efficiency is improved with the addition of the proposed open stub in the radiating element of the PIFA without disturbing the operating resonance frequencies of the antenna. In specific cases, various simulated and fabricated PIFA models illustrate that the return loss, bandwidth, gain, and efficiency values of antennas with longer optimum open stub lengths can be enhanced up to 4.6 dB, 17%, 1.8 dBi, and 12.4% respectively, when compared with models that do not have open stubs. The proposed open stub is small and does not interfere with the surrounding active modules; therefore, this method is extremely attractive from a practical implementation point of view. The second presented work is a simple procedure for the development of a lumped equivalent circuit model of a dual band PIFA using the rational approximation of its frequency domain response. In this method, the PIFA's measured frequency response is approximated to a rational function using a vector fitting technique and then electrical circuit parameters are extracted from it. The measured results show good agreement with the electrical circuit results. A correlation study between circuit elements and physical open stub lengths in various antenna models is also discussed in detail; this information could be useful for the enhancement of the performance of a PIFA as well as for its systematic design. The computed radiated power obtained using the electrical model is in agreement with the radiated power results obtained through the full wave electromagnetic simulations of the antenna models. The presented approach offers the advantage of saving computation time for full wave EM simulations. In addition, the electrical circuit depicting almost perfect characteristics for return loss and radiated power can be shared with antenna users without sharing the actual antenna structure in cases involving confidentiality limitations.

Design of Small-Scaled Permanent Magnet Generators for Wind Power Applications (풍력용 소용량 영구자석형 발전기의 설계)

  • Jang, Seok-Myeong;Choi, Jang-Young;Cho, Han-Wook;You, Dae-Joon;Kyoung, Nam-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2006.04b
    • /
    • pp.194-196
    • /
    • 2006
  • This paper deals with design of a small-scaled permanent magnet generator (PMG) for wind power applications. First, this paper determines rated power and rated speed of the PMG from measured characteristics of wind turbines. Second, we derive analytical solutions for the open-circuit field in order to determine optimum magnet thickness and pole pitch/arc ratio. Third, on the basis of open circuit field solutions, stator magnetic circuit is designed. And then, a diameter of stator coil which agree with a required current density is calculated, and its turns are determined from the area of slot. Finally, finite element (FE) method is employed for validity of the designed PMG and, the back-emf measurements are also given to confirm the design.

  • PDF

Design and Analysis of Direct-Coupled, Small-Scaled Permanent Magnet Generator for Wind Power Application (풍력발전을 위한 소용량 영구자석형 동기발전기의 설계 및 해석)

  • Kim, Il-Jung;Choi, Jang-Young
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.28 no.5
    • /
    • pp.39-51
    • /
    • 2014
  • This paper deals with design of a direct-coupled, small-scaled permanent magnet generator (PMG) for wind power application. First, this paper determines rated power and speed of the PMG from measured characteristics of wind turbines. Second, we derive analytical solutions for the open-circuit field in order to determine optimum magnet thickness and pole pitch/arc ratio. Third, on the basis of open circuit field solutions, stator magnetic circuit including slot opening, teeth width and yoke thickness is designed. And then, a diameter of stator coil which agree with a required current density is calculated, and its turns are determined from the area of slot considering winding packing factor. Finally, finite element (FE) method is employed in analyzing the details of the designed PMG and, test results such as back-emf measurements are given to confirm the design.

Operating Characteristics on Coupling of Fuel-Cell System with Natural Gas Reformer (휴대전원용 직접알코올 연료전지의 OCV특성 연구)

  • Park, Se-Joon;Choi, Yong-Sung;Lee, Kyung-Sup
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.58 no.4
    • /
    • pp.592-596
    • /
    • 2009
  • DAFC(direct alcohol fuel cell) takes the same structure and operational principle with PEMFC(Proton exchange membrane fuel cell). However, DAFC, which uses liquid alcohol instead of hydrogen as fuel, is able to be used as a portable power for small-scaled electronic devices such as MP3, PMP, and mobile phone because alcohol is quite convenient steady-state compound to carry and store it. This paper presents the OCV(open circuit voltage) characteristics of the cases which are alcohol species and different weight rate of ethanol, respectively. The OCV of methanol fuel cell is slightly higher 0.2V than ethanol one, and 8% wt. rate ethanol is rated as the most appropriate fuel for DAFC.

The Analysis and Application of the Parallel Coupled Line with Open Stub (개방 스터브를 갖는 평행결합선로의 해석과 응용)

  • Lee, Won-Kyun;Lee, Hong-Seob;Hwang, Hee-Yong
    • Journal of Industrial Technology
    • /
    • v.27 no.B
    • /
    • pp.153-160
    • /
    • 2007
  • In this paper, the exact analysis of the parallel coupled line with open stub is presented. This structure shows LPF characteristics with broad stopband and sharp skirt characteristics. We derived the exact Z-matrix expression of the structure. In order to show the validation of the expression we designed $3^{th}$ order Chebyshev LPF using the structure. The simulated data excellently agreed with the predicted values by the calculation using the derived expression.

  • PDF