• Title/Summary/Keyword: Open voltage

Search Result 886, Processing Time 0.024 seconds

A Study on Development of Open-Phase Protector Having Leakage Current Generation and Incapable Operation Prevention at Open-Phase Accident (결상 시 누전전류 발생과 오동작 방지 기능을 갖는 결상보호기 개발에 관한 연구)

  • Kwak, Dong-Kurl
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.64 no.1
    • /
    • pp.182-187
    • /
    • 2015
  • In the three-phase power system, when any one-phase or two-phases is open-phase, the unbalanced current flows and the single-phase power supplies to three-phase loads. Specially, motor coil and transformer coil receive over-current. As a result, great damage as well as electrical fire can occur to the power system. In order to improve these problems, this paper proposes that an open-phase detection device is designed by a new algorithm using electric potential difference between the resultant voltage of neutral point and ground, and a control circuit topology of open-phase protector is composed of highly efficient semiconductor devices. It improves response speed and reliability. The control algorithm circuit also operates the cut-off of a conventional residual current protective device (RCD) which flows an enforced leakage current to ground wire at open-phase accident. Furthermore, time delay circuit is added to prevent the incapable operation of open-phase protector about instantaneous open-phase not open-phase fault. The time delay circuit improves more reliability.

Stretchable Characteristics and Power Generation Properties of a Stretchable Thermoelectric Module Filled with PDMS (PDMS로 충진된 신축열전모듈의 신축특성과 발전특성)

  • Han, Kee Sun;Oh, Tae Sung
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.26 no.4
    • /
    • pp.149-156
    • /
    • 2019
  • A stretchable thermoelectric module consisting of 5 pairs of Bi2Te3-based hot-pressed p-n thermoelectric legs was processed by filling the module inside with polydimethylsiloxane (PDMS) and removing the top and bottom substrates. Its stretchable characteristics and power generation properties were measured. The integrity of the module was kept well even after 10 strain cycles ranging from 0 to 0.1. With increasing the tensile strain to 0.2, the module circuitry became open because of joint failure between Cu electrodes and thermoelectric legs. The stretchable thermoelectric module exhibited an open circuit voltage of 4.6 mV with a temperature difference of 2.2K across both ends of thermoelectric legs, and changes in its open circuit voltage were below 5% for tensile strains of 0~0.1. Being elongated for a strain of 0.1, it exhibited the maximum output power of 18.5 ㎼ with the temperature difference of 2.2K across its both ends.

Numerical Analysis of Electro-Hydrodynamic (EHD) Flows in Electrostatic Precipitators using Open Source Computational Fluid Dynamics (CFD) Solver (오픈 소스 전산 유체 역학 해석 프로그램을 이용한 전기집진기 내부 정전 유동 해석)

  • Song, Dong Keun;Hong, Won Seok;Shin, Wanho;Kim, Han Seok
    • Particle and aerosol research
    • /
    • v.9 no.2
    • /
    • pp.103-110
    • /
    • 2013
  • The electrostatic precipitator (ESP) has been used for degrading atmospheric pollutants. These devices induce the electrical forces to facilitate the removal of particulate pollutants. The ions travel from the high voltage electrode to the grounded electrode by Coulomb force induced by the electric field when a high voltage is applied between two electrodes. The ions collide with gas molecules and exchange momentum with each other thus inducing fluid motion, electrohydrodynamic (EHD) flow. In this study, for the simulation of electric field and EHD flow in ESPs, an open source EHD solver, "espFoam", has been developed using open source CFD toolbox, OpenFOAM(R) (Open Field Operation and Manipulation). The electric potential distribution and ionic space charge density distribution were obtained with the developed solver, and validated with experimental results in the literature. The comparison results showed good agreement. Turbulence model is also incorporated to simulate turbulent flow; hence the developed solver can analyze laminar and turbulent flow. In distributions of electric potential and space charge, the distributions become distorted and asymmetric as the flow velocity increases. The effect of electrical drift flow was investigated for different flow velocities and the secondary flow in a flow of low velocity is successfully predicted.

Substation Bus Voltage Angle Calculation Method Using Voltage Angle Difference Measured at the Tie Switch in the Distribution Line (배전선로 상시연계점 측정 전압 위상차를 이용한 변전소 모선 위상각 추정 방법)

  • Son, Ju-Hwan;Lim, Seong-Il
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.1
    • /
    • pp.9-15
    • /
    • 2016
  • Distribution networks are operated in radial fashion during the normal state. Loop configuration is also required temporally in case of live load transfer among the adjacent feeders. Voltage angles of each substation buses are very important data in order to calculate power flow of the loop structured distribution feeders. This paper proposes substation bus voltage angle calculation method using voltage angle difference measured at the normally open tie switches. Simulation case studies using Matlab simulink have been performed to establish feasibility of proposed method.

Control Strategies of Both the Heater Temperature and the Inverter Output Voltage of a Single-Phase PWM Inverter Systems for Heat Treatment (열처리용 단상 PWM인버터시스템의 히터온도 및 인버터 출력전압 제어기법)

  • Yang, Si-Gyeong;Chun, Tae-Won
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.67 no.8
    • /
    • pp.1047-1054
    • /
    • 2018
  • This paper proposed the strategies for controlling both the heater temperature and the output voltage of a single-phase inverter for the heat treatment. The single-phase inverter system for the heat treatment controls the heater temperature to its reference one, and also it limits the inverter output voltage to 60 V for safety. The stability may be deteriorated due to the large time constant difference between the heater temperature and inverter output voltage. In order to ensure the stability, a hysteresis on/off control approach for the heater temperature control is adapted, and both the open-loop and the closed-loop control strategies of the output voltage are suggested. The performances for the proposed strategies are demonstrated with the experiments.

Properties of Single $K^{+}$ Channels of Skeletal Muscle Incorporated into Planar Lipid Bilayer

  • Park, Jin-Bong;Kim, Hee-Jeong;Cho, Myung-Haing;Lee, Hang;Park, Hong-Ki;Lee, Mun-Han;Ryu, Pan-Dong
    • The Korean Journal of Physiology
    • /
    • v.29 no.1
    • /
    • pp.13-27
    • /
    • 1995
  • single $K^{+}$ channels of skeletal muscle from the rat and frog were into planar lipid bilayers and their properties were studied. Fusion was induced by an osmotic gradient. Of the four types of $K^{+}$ channels recorded, the two most frequently observed were a voltage and $Ca^{2+}-activated$ $K^{+}$ channel and a $K^{+}$ channel with a prominent conductance substate. The first $K^{+}$ channel was identified as the large $Ca^{2+}-activated$ $K^{+}$ (BK) channel because the open-state probability was increased with depolarization (e-fold change per $10.6{\pm}3.5$ mV, n=8) and internal $Ca^{2+}$ (half-activation at $16.7{\pm}3.8$ mV, n=8, pCa 4) and its conductance was large ($247{\pm}4.9$ pS, n=24 in 0.1 M KCI). Lifetime distributions of open- and closed-states could be fitted with single exponentials of several milliseconds. The mean open- and closed-lifetimes were linearly dependent on the intracellular $[Ca^{2+}]$ and $1/[Ca^{2+}]$, respectively. The second $K^{+}$ channel showed a conductance substate at $30{\sim}60%$ of the open state. Its current-voltage relation was linear in the range of $-80\;{\sim}\;+80\;mV$. The slope conductance of the substate and open-state were 40 and 144 pS in 0.2 M KCl, respectively. The channel was highly selective for $K^{+}$ over Cl. The open-state probability was weakly voltage-dependent (e-fold change per 35 mV. The lifetime distributions of open- and closed-states were fitted with two exponentials and the major gating occurred slowly at several hundred milliseconds. Based on the above results, we think the second type of $K^{+}$ channel is the sarcoplasmic reticulum $K^{+}$ (SRK) channel. In addition, both types of channel were also incorporated into the lipids extracted from the skeletal muscle. The channel properties recorded in the bilayers termed from synthetic and extracted lipids were qualitatively similar. Our data indicate that BK and SRK channels are rich in the skeletal muscle and their properties and regulation could be effectively studied in planar lipid bilayer.

  • PDF

PEMFC performance on reverse voltage by fuel starvation (연료 부족에 의한 고분자전해질형 연료전지의 역전압 성능)

  • Lee, Hung-Joo;Song, Hyun-Do;Kim, Jun-Bom
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.17 no.2
    • /
    • pp.133-140
    • /
    • 2006
  • The performance of proton exchange membrane fuel cell was decreased by reverse voltage using fuel starvation. Performance decrease in local area could be affected by duration and extent of reverse voltage. Hydrogen and air stoichiometic ratio was used to find the experimental condition of abrupt voltage decrease. LabVIEW was used to make control logic of automatic load off system in preset voltage. Reverse voltage experiment was done down to -1.2 V at constant current condition. When fuel cell voltage was reached to preset voltage, electronic load was disconnected to make open circuit voltage for 1 minute. Fuel cell performance was checked every 5 cycle and the degree of performance decrease and/or recovery was estimated. Ohmic resistance and charge transfer resistance were increased and platinum surface area was reduced 41% after reverse voltage experiment.

A Low-voltage Vibrational Energy Harvesting Circuit using a High-performance AC-DC converter (고성능 AC-DC 변환기를 이용한 저전압 진동에너지 하베스팅 회로)

  • Kong, Hyo-sang;Han, Jang-ho;Choi, Jin-uk;Yoon, Eun-jung;Yu, Chong-gun
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2016.10a
    • /
    • pp.533-536
    • /
    • 2016
  • This paper describes a vibrational energy harvesting circuit with MPPT control. A high-performance AC-DC converter of which the efficiency is improved by using body-bias technique and bulk-driven technique is proposed and applied for the vibrational energy harvesting circuit design. MPPT (Maximum Power Point Tracking) control function is implemented using the linear relationship between the open-circuit voltage of a vibrational device and its MPP voltage. The designed MPPT control circuit traces the maximum power point by periodically sampling the open circuit voltage of a vibrational device, makes the reference voltages using sampled voltage and delivers the maximum available power to load. The proposed circuit is designed with a $0.35{\mu}m$ CMOS process, and the chip area is $1.21mm{\times}0.98mm$.

  • PDF

Design of a Low Phase Noise Voltage Tuned Planar Composite Resonator Oscillator Using SIW Structure (SIW 구조를 이용한 저 위상잡음 전압 제어 평판형 복합공진기 발진기 설계)

  • Lee, Dong-Hyun;Son, Beom-Ik;Yeom, Kyung-Whan
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.25 no.5
    • /
    • pp.515-525
    • /
    • 2014
  • In this paper, we present a design and implementation of a Voltage-tuned Planar Composite Resonator Oscillator(Vt-PCRO) with a low phase noise. The designed Vt-PCRO is composed of a resonator, two phase shifters, and an amplifier. The resonator is designed using a dual mode SIW(Substrate Integrated Waveguide) resonator and has a group delay of about 40 nsec. Of the two phase shifters (PS1 and PS2), PS1 with a phase shift of $360^{\circ}$ is used for the open loop gain to satisfy oscillation condition without regard to the electrical lengths of the employed microstrip lines in the loop. PS2 with a phase shift of about $70^{\circ}$ is used to tune oscillation frequency. The amplifier is constructed using two stages to compensate for the loss of the open loop. Through the measurement of the open loop gain, the tune voltage of the PS1 can be set to satisfy the oscillation condition and the loop is then closed to form the oscillator. The oscillator with a oscillation frequency of 5.345 GHz shows a phase noise of -130.5 dBc/Hz at 100 kHz frequency offset. The oscillation power and the electrical frequency tuning range is about 3.5 dBm and about 4.2 MHz for a tuning voltage of 0~10 V, respectively.

Fault-Tolerant Strategy to Control a Reverse Matrix Converter for Open-Switch Faults in the Rectifier Stage

  • Lee, Eunsil;Lee, Kyo-Beum
    • Journal of Power Electronics
    • /
    • v.16 no.1
    • /
    • pp.57-65
    • /
    • 2016
  • Reverse matrix converters, which can step up voltages, are suitable for applications with source voltages that are lower than load voltages, such as generator systems. Reverse matrix converter topologies are advantageous because they do not require additional components to conventional matrix converters. In this paper, a detection method and a post-fault modulation strategy to operate a converter as close as possible to its desired normal operation under the open-switch fault condition in the rectifier stage are proposed. An open-switch fault in the rectifier stage of a reverse matrix converter causes current distortions and voltage ripples in the system. Therefore, fault-tolerant control for open-switch faults is required to improve the reliability of a system. The proposed strategy determines the appropriate switching stages from among the remaining healthy switches of the converter. This is done based on reference currents or voltages. The performance of the proposed strategy is experimentally verified.