• Title/Summary/Keyword: Open suction

Search Result 52, Processing Time 0.022 seconds

Effect of Opening Roller Speed, Drums Speed Difference and Suction Air Pressure on Properties of Open-End Friction Spun Polyester and Acrylic Yarns

  • Vishnoi Prashant;Ishtiaque S. M.;Das A.
    • Fibers and Polymers
    • /
    • v.6 no.3
    • /
    • pp.250-258
    • /
    • 2005
  • The present paper is concerned with the influence of opening roller speed, drum speed difference and suction air pressure on properties of polyester and acrylic open-end friction spun yams. The results shows that the opening roller speed and the suction air pressure have considerable influence on the characteristics of polyester and acrylic open-end friction spun yams. In case of polyester yams the unevenness, imperfection and hairiness decreases and the yam tenacity increases with the increase in opening roller speed and suction air pressure. However for acrylic yams the unevenness and imperfections decreases and tenacity increases with the increase in opening roller speed and suction air pressure.

Comparison of a Closed with an Open Endotracheal Suction: Costs and the Incidence of Ventilator-associated Pneumonia (비용, 인공환기관련폐렴 발생 빈도에 있어서의 개방 기관내 흡인술에 대한 폐쇄 흡인술의 비교)

  • Jung, Jae Woo;Choi, Eun Hee;Kim, Jin Hee;Seo, Hyo Kyung;Choi, Ji Yeon;Choi, Jae Cheol;Shin, Jong Wook;Park, In Won;Choi, Byoung Whui;Kim, Jae Yeol
    • Tuberculosis and Respiratory Diseases
    • /
    • v.65 no.3
    • /
    • pp.198-206
    • /
    • 2008
  • Background: Tracheobronchial suctioning using the closed suctioning system has physiological benefits for critically ill patients. Despite these benefits, there are concerns about increased colonization of tracheobronchial tree by pathogenic organisms. The cost is another hinder to the introduction of closed suction system. The aim of this study was to evaluate the incidence of colonization and ventilator associated pneumonia and the cost-effectiveness of closed suction compared with open suction. Methods: During separated one month period, patients admitted MICU were cared by multiple-use, open suction, single-use, open suction and multiple-use, closed suction method, consecutively. Costs, colonization of tracheobronchial tree by MRSA and the incidence of ventilator-associated pneumonia (VAP) were analyzed. Results: One-hundred and six patients were enrolled. Twenty patients were treated with multiple-use, open suction, while 42 and 44 patients were cared with single-use, open catheter and multiple-use, closed catheter, respectively. Colonization by MRSA and the incidence of VAP were not different among three ways of suctioning. The overall costs per patient per day for suctioning were $10.58 for multiple-use, open suction, $28.27 for single-use, open suction and $23.76 for multiple-use, closed suction. Conclusion: Multiple-use, closed suctioning, when suction catheters were changed every 48 hrs, has the similar incidence of colonization of MRSA and occurrence of VAP and is a cost-efficient way of endotracheal suction.

A Comparison of the Opened Versus Closed-System of Suctioning -In Oxygen Saturation, Vital Signs and Suction Time- (개방형 흡인술과 폐쇄형 흡인술이 인공호흡기 사용 중환자의 산소포화도와 활력징후에 미치는 효과)

  • Seo, Min-Sook;Park, Kyung-Sook
    • Korean Journal of Adult Nursing
    • /
    • v.21 no.2
    • /
    • pp.141-154
    • /
    • 2009
  • Purpose: The purpose of this study was to compare the difference of change in oxygen saturation, vital signs and suction time taken for the suctioning during endotracheal suctioning performed with closed suction system and with opened suction system. Methods: Data were collected from 31 adult patients with ventilator treatment who were admitted to a university hospital in Seoul and the collection period was from July 1 to November 15, 2005. Oxygen saturation, heart rate, respiration rate and mean arterial pressure were collected immediately prior to the suctioning intervention, during and 1 and 5 minutes after the suctioning from opened suction system and closed suction system. Results: 1) The difference in oxygen saturation was statistically significant in recovery time for oxygen saturation to return to baseline values after suctioning was significantly rapid on closed suction system (p<.05). 2) The difference in heart rate, respiration rate and mean arterial pressure was statistically insignificant 3) The suction time was shorter in closed suction system. Conclusion: Closed suction system is more efficient, as compared with the open suction system in the ventilator treatment.

  • PDF

Effect of Air Layer on the Performance of an Open Ducted Cross Flow Turbine

  • Wei, Qingsheng;Chen, Zhenmu;Singh, Patrick Mark;Choi, Young-Do
    • The KSFM Journal of Fluid Machinery
    • /
    • v.18 no.1
    • /
    • pp.11-19
    • /
    • 2015
  • Recently, the cross flow turbines attract more attention for their good performance over a large operating regime at off design point. This study employs a very low head cross flow turbine, which has open inlet duct and has barely been studied before, to investigate the performance of the cross flow turbine with air suction from the rear part of the runner. Unlike conventional cross flow turbines, a draft tube is attached to the outlet of runner to improve the turbine performance. Water level and pressure in the draft tube are monitored to investigate the influence of air suction. Torque at local blade passage of three parts of runner is examined in detail under the conditions of different air suction. Consequently, it is found that with proper air suction in the runner chamber, the water level in the draft tube gradually drops to Stage 2 of the runner and the efficiency of the turbine can be raised by 10%. Overall, the effect of air-layer on the performance of the turbine is considerable.

Parametric Study on Scouring around Suction Bucket Foundation (파라미터 변화에 따른 석션버켓기초에 발생하는 세굴현상에 대한 수치해석 연구)

  • Park, Sunho;Song, Seongjin;Wang, Haiqing;Joung, Taehwan;Shin, Yunsup
    • Journal of Ocean Engineering and Technology
    • /
    • v.31 no.4
    • /
    • pp.281-287
    • /
    • 2017
  • In the case of fixed offshore wind turbines, scouring phenomena have been reported around sub-structures as a result of currents, which seriously damage the structural stability. A parametric study of the various sub-structures of a fixed offshore wind turbine was performed to investigate their effects on the scouring phenomena. For a suction bucket foundation and monopile, the effects of the stick-up heights and water depth were studied, respectively. The open source libraries, called OpenFOAM, were used to simulate a violent flow around a foundation. The numerical methods were selected based on a two-dimensional analysis of a suction bucket. Based on the results for various stick-up heights, a larger scouring region was observed with an increase in the stick-up height because of the down-wash flow around a foundation. Based on the results for various monopile water depths, the water depth had an insignificant effect on the scouring.

Effects of Tracheal Suction and Method of Bronchodilator Inhalation on Vital Signs and Pulmonary functions in Patients with Open Heart Surgery(OHS) (심장수술 환아에게 기도흡인과 기관지 확장제의 투여 방법이 활력징후 및 폐기능에 미치는 효과)

  • Song Hyo-Sook;Jun Tae-Gook;Park Pyo-Won;Kim Kyoung-Eun;Chung Ji-Hye
    • Journal of Korean Academy of Fundamentals of Nursing
    • /
    • v.10 no.1
    • /
    • pp.96-107
    • /
    • 2003
  • Objective: The purpose of this study was to identify the effects of tracheal suction and the effects of different methods of bronchodilator inhalation (Ultrasonic nebulizer: MDI puff, MDI puff with spacer) in VSD surgery patients. Material & Method: From June 2001 to March 2002, sixty consecutive patients were randomly assigned to a control group (n= 15), ultrasonic nebulizer group (n=15), metered dose inhalation (MDI) puff group (n=15) and MDI with spacer group (n=15). Vital signs (HR, BP, CVP), ABGA and pulmonary functions were measured before suction (baseline for suction), after suction, 15 minutes after suction (base of bronchodilator inhalation), 30 minutes after bronchodilator inhalation, and 2 hours after bronchodilator inhalation. Stastistical analysis was performed using SPSS software. Repeated measure ANOVA was used to examine the effects of tracheal suction. One way ANOVA with Bonferroni's correction and multiple range test (the least significant difference test) were used to examine the effects of albuterol inhalation. Result: 1. Heart .ate increased significantly immediately after suction (p<.01) and recovered 15 minutes after suction. 2. $PaO_2$ and PH decreased significantly immediately after suction (p<.05) and $PaO_2$ recovered 15 minutes after suction. $PaCO_2$ increased immediately after suction and significantly 15 minutes after suction (p<.01). But changes in vital signs and ABGA were within the normal range. 3. Tidal volume decreased significantly 15 minutes after suction (p<.05). 4. Changes of HR and tidal volume were greater in the nebuizer group compared to the other groups (p<.05) 30 minutes after bronchodilator inhalation and recovered 2 hours after bronchodilator inhalation. 5. Changes of airway deadspace was greater in the nebulizer group compared to the control group and MDI puff group 30 minutes after albuterol inhalation (p<.05) and at 2 hours (p<.01). Conclusion: Tracheal suction did not have significant effect on vital signs and pulmonary functions after OHS. Although the methods of bronchodilator inhalation did not showed any significant difference on pulmonary function, the nebulizer method increased $PaO_2$ (20%) and tidal volume transiently. If the patient needs bronchodilator inhalation with bronchospasm after OHS, the nebulizer method is the best choice. More study on the effects of bronchodilator inhalation in bronchospasm group is needed.

  • PDF

Effects of Open or Closed Suctioning on Lung Dynamics and Hypoxemia in Mechanically Ventilated Patients (기관 내 흡인 유형이 인공호흡기 대상자의 폐기능과 저산소혈증에 미치는 효과)

  • Lee, Eun Young;Kim, Su Hyun
    • Journal of Korean Academy of Nursing
    • /
    • v.44 no.2
    • /
    • pp.149-158
    • /
    • 2014
  • Purpose: This study was conducted to compare effects of open and closed suctioning methods on lung dynamics (dynamic compliance, tidal volume, and airway resistance) and hypoxemia (oxygen saturation and heart rate) in mechanically ventilated patients. Methods: This study was a cross-over repeated design. Participants were 21 adult patients being treated with endotracheal intubation using a pressure-controlled ventilator below Fraction of Inspired Oxygen ($FiO_2$) 60% and PEEP $8cmH_2O$. Data were collected at baseline and 1, 2, 3, 4, 5, and 10 minutes after suctioning. Data were analyzed using two-factor ANOVA with repeated measures on time and suctioning type. Results: Effects of the interaction between suction type and time were significant for oxygen saturation and heart rate but not significant for dynamic compliance, tidal volume, or airway resistance. Prior to performance of suctioning, tidal volume and oxygen saturation were significantly lower, but airway pressure and heart rate were significantly higher using the closed suctioning method as compared with the open suctioning method. Conclusion: For patients on ventilator therapy below $FiO_2$ 60% and PEEP $8cmH_2O$, open suctioning performed after delivery of 100% $FiO_2$ using a mechanical ventilator may not have as much negative impact on lung dynamics and hypoxemia as closed suctioning.

Endotracheal Colonization and Ventilator-associated Pneumonia in Mechanically Ventilated Patients according to Type of Endotracheal Suction System (기관 흡인술 유형에 따른 인공호흡기 적용 환자의 기관 내 균집락화와 폐렴 발생률)

  • Cha, Kyeong-Sook;Park, Ho-Ran
    • Journal of Korean Academy of Nursing
    • /
    • v.41 no.2
    • /
    • pp.175-181
    • /
    • 2011
  • Purpose: This study was conducted to identify endotracheal colonization and the incidence of ventilator-associated pneumonia related to the type of endotracheal suction system. Methods: The participants in this study were ICU patients hospitalized between October 2009 to March 2010 who used ventilators for over 48 hr with closed (CSS, n=30) or open (OSS, n=32) suction systems. To standardize the pre-intervention suction system, a suctioning protocol was taught to the ICU nurses. Collected data were analyzed using ${\chi}^2$-test, Fisher's exact test, Wilcoxon rank sums test, Wilcoxon test, Log-rank test and Poisson regression. Results: Endotracheal colonization was higher in OSS than CSS from day 1 to day 8 while using a ventilator and there was a significant difference between the two groups. The CSS reached 50% of endotracheal colonization by the 4th day, whereas for the OSS, it was the 2nd day (p=.04). The incidence of ventilator-associated pneumonia showed no significant difference. Conclusion: For patients with a high risk of pneumonia, CSS must be used to lower endotracheal colonization.

Proper Time of the Sterile Tracheal Suction Catheter Change Based on Nursing Clinic (기도흡인용 카테터의 교환시기를 규명하기 위한 임상적 근거)

  • Lee, Myung-Ok;Lee, Yoo-Jin
    • Journal of Korean Biological Nursing Science
    • /
    • v.5 no.1
    • /
    • pp.45-53
    • /
    • 2003
  • The purpose of this study was to identify the proper changing time of tracheal suction catheter by examining the microorganisms inside after used The samples were the adult and the elderly patients who were in the intensive cane unit of one university hospital in Korea from the early December, 2002 to the end of May 2003. Since the patients needed tracheal suction, sterile catheter including other equipments were used whenever tracheal suction provided, to the experimental group. The sterile catheter with others was provided when the catheter repeatedly used for four hours, to the comparative group. Research was permitted by the head of hospital administration, hospital nursing department; microbiology and intensive care unit. The main results of the study are as follows. 1) The demographic characteristics between the two groups present statistically no difference. 2) Every the experimental group showed various kinds of microorganisms, the numbers of the kinds and carries of the microorganisms were less than those of the comparative group. 3) The mean numbers of the microorganisms between the two groups were significantly different, p < 0.05. This study results strongly emphasize the needs of using sterile catheter whenever a nurse suctions to keep patient's airway open.

  • PDF

Investigation on the Penetration Resistance of Suction Bucket Foundation in Sand using Model Test (모형실험을 통한 모래지반에서 석션버켓기초의 관입저항력 평가)

  • Kim, Keunsoo;Kwon, Osoon;Oh, Myounghak;Jang, Insung
    • Journal of the Korean GEO-environmental Society
    • /
    • v.15 no.6
    • /
    • pp.75-83
    • /
    • 2014
  • Suction bucket foundation is installed with the differential pressure created by pumping water out of bucket. Bucket foundation has usually been utilized in mooring anchor for offshore platform or floating oil and gas production facilities in the open sea. After suction bucket foundation successfully was applied as the foundation for offshore wind turbines in Europe, it recently attracts much attention in Korea, too. To estimate the penetration resistance of the suction bucket foundation is one of the important matters that should be considered during its installation. This study carried out a series of model tests to investigate the penetration resistance of suction bucket foundation. And the mobilized soil strength factor was reviewed through comparing the experimental results by two installation ways (e.g., push-in-load and suction) and the results calculated by the conventional equation.