• Title/Summary/Keyword: Open fault

Search Result 267, Processing Time 0.025 seconds

Estimation Method of Cable Fault Location in Rocket Motors Using M-sequence Signals (M시퀀스 신호를 이용한 로켓 추진기관 케이블 결함 위치 추정 기법)

  • Son, Ji-Hong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.5
    • /
    • pp.84-92
    • /
    • 2020
  • This paper describes the estimation method of cable fault location in rocket motors using M-sequence (Maximal Length Sequence). In order to estimate the location of a cable fault, three methods have been usually used: TDR (Time Domain Reflectometry), FDR (Frequency Domain Reflectometry), and TFDR (Time-Frequency Domain Reflectometry). However, these methods suffer the disadvantage of requiring users to be close to a test field, which is dangerous. The estimation method of cable fault location using M-sequence is proposed to solve this problem. The proposed method can make use of DAS (Data Acquisition System). The experiments were three cases: damaged, open, and short. The RG-58 coaxial cable was used in the experiments. As a result, the proposed method has better performance than that of conventional methods such as TDR and TFDR.

Fault Diagnosis of Voltage-Fed Inverters Using Pattern Recognition Techniques for Induction Motor Drive (패턴인식 기법을 이용한 유도전동기 구동용 전압형 인버터의 고장진단)

  • Park, Jang-Hwan;Park, Sung-Moo;Lee, Dae-Jong;Kim, Dong-Hwa;Chun, Myung-Geun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.19 no.3
    • /
    • pp.75-84
    • /
    • 2005
  • Since an unexpected fault of induction motor drive systems can cause serious troubles in many industrial applications, which the technique is required to diagnose faults of a voltage-fed PWM inverter for induction motor drives. The considered fault types are rectifier diodes, switching devices and input terminals with open-circuit faults, and the signal for diagnosis is derived from motor currents. The magnitude of dq-current trajectory is used for the feature extraction of a fault and PCA LDA are applied to diagnose. Also, we show results with respect to the execution time because of the possibility to use that a diagnosis software is embedded in the controllers of medium and small size induction motors drive for real-time diagnosis. After we performed various simulations for the fault diagnosis of the inverter, the usefulness of proposed algerian was verified.

Implementation of the Traffic Control System based Low Cost Dual Modular Redundancy (저비용 이중화 시스템 기반 교통신호제어 (시스템) 구현)

  • Lee, Dong-Woo;Na, Jong-Whoa;Kim, Nam-Sun
    • Journal of Advanced Navigation Technology
    • /
    • v.21 no.5
    • /
    • pp.491-500
    • /
    • 2017
  • This paper investigates a low cost dual modular redundancy system based on heartbeat which can be applied to traffic control signal system. Failure of the traffic control signal system can cause traffic confusion and traffic accidents. Therefore safety and reliability of traffic control should be secured using fault tolerance technology. To do this, we configured a redundant board using the open source hardware and the heartbeat technique of Linux HA. The function of the traffic signal control system was verified and the fault recovery time was measured using fault injection test. As a result of the test, the fault recovery time was confirmed to be less than 9 seconds on average, confirming that the reliability target time is satisfied. Based on the results of this study, it is expected that it can be applied to fields requiring high reliability systems such as aviation, space, and nuclear power embedded systems.

Fault Diagnosis of 3 Phase Induction Motor Drive System Using Clustering (클러스터링 기법을 이용한 3상 유도전동기 구동시스템의 고장진단)

  • Park, Jang-Hwan;Kim, Sung-Suk;Lee, Dae-Jong;Chun, Myung-Geun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.18 no.6
    • /
    • pp.70-77
    • /
    • 2004
  • In many industrial applications, an unexpected fault of induction motor drive systems can cause serious troubles such as downtime of the overall system heavy loss, and etc. As one of methods to solve such problems, this paper investigates the fault diagnosis for open-switch damages in a voltage-fed PWM inverter for induction motor drive. For the feature extraction of a fault we transform the current signals to the d-q axis and calculate mean current vectors. And then, for diagnosis of different fault patterns, we propose a clustering based diagnosis algorithm The proposed diagnostic technique is a modified ANFIS(Adaptive Neuro-Fuzzy Inference System) which uses a clustering method on the premise of general ANFIS's. Therefore, it has a small calculation and good performance. Finally, we implement the method for the diagnosis module of the inverter with MATLAB and show its usefulness.

A Novel Testing Method for Operational Amplifier Using Offset and High Frequency (오프셋과 고주파수를 이용한 연산증폭기의 새로운 테스트 방식)

  • 송근호;백한석;문성룡;서정훈;김강철;한석붕
    • Proceedings of the IEEK Conference
    • /
    • 2000.06b
    • /
    • pp.189-192
    • /
    • 2000
  • In this paper, we propose the novel test method to detect short and open faults in CMOS Op-amp. The proposed method is composed of two test steps - the offset and the high frequency test. Using HSPICE simulation, we get a 100% fault coverage. To verify the proposed method, we design and fabricate the CMOS op-amp that contains various short and open faults through Hyundai 0.65$\mu\textrm{m}$ 2-poly 2-metal CMOS process. Experimental results of fabricated chip demonstrate that the proposed test method can detect short and open faults in CMOS Op-amp.

  • PDF

An Instrumentation System Design for Electrical Accident Prevention of 3-Phase Electrical Control Panel (3상 전기제어반 전기사고 예방을 위한 계측시스템 설계)

  • Kwak, D.K.;Choi, J.K.;Kim, J.J.;Kwon, Y.J.;Song, G.
    • Proceedings of the KIPE Conference
    • /
    • 2016.07a
    • /
    • pp.36-37
    • /
    • 2016
  • The main cause of electrical fires are caused due to short circuit and open circuit. This is generates an instantaneous electric arc or spark accompanied with such electric faults. These arcs generate a pressed wire, contact badness, and a weakness in the wire coating etc.. This research proposes a protection circuit to prevent open-phase accident due to contact failure of electromagnetic contactor, tracking arc fault, open-phase within the three-phase electrical control panel which is the most commonly applied in the industry. The proposed circuit also alarms and cuts off of power system when electrical faults occurs. In addition, the proposed circuit is validated by various electric accident simulator.

  • PDF

Reconfigurable Position Control of Unmanned Expedition Vehicles under the Open Control Platform based Ubiquitous Environment (유비쿼터스 환경에서 개방형 제어 플랫폼에 기반한 무인탐사차량의 재형상 가능 위치제어)

  • Shim Duk-Sun;Yang Cheol-Kwan;Ah Kyu-Seob;Lee Joon-Hak
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.11 no.12
    • /
    • pp.1002-1010
    • /
    • 2005
  • We study on the implementation of reconfigurable position control system which is based on Open Control Platform(OCP) for Unmanned Expedition Vehicles(UEV) in ubiquitous environment. The control system uses hierarchical control structure and OCP structure which contains three layers such as core OCP, reconfigurable control API(Application Programmer Interface), generic hybrid control API. The goal of our research is to implement an UEV control system using advanced software technology. As a specific control problem, we study a transition management problem between PID control and neural network control depending on fault or parameter change of the plant, i.e., UEV. The concept of the OCP-based software-enabled control can provide synergy effect by the integration of software component, middleware, network communication, and control, and thus can be applied to various systems in ubiquitous environment.

A Method for Optimal Location of Feeder Tie Switches for Improving Equal Load of Electric Power Equipment in Distribution Automation System (배전자동화 시스템에서 전력설비 부하균등화를 고려한 피더간 연계점 최적위치선정)

  • Lim, Il-Hyung;Lim, Seong-Il;Choi, Myeon-Song;Lee, Seung-Jae;Shin, Chang-Hoon;Ha, Bok-Nam
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.5
    • /
    • pp.821-828
    • /
    • 2007
  • This paper proposes a new algorithm to find optimal location of open switches connecting feeders in distribuion system. In order to enhance power system reliability by minimizing outage area in case of fault, the load balance among the facilities such as transformers and feeders is considered to optimize. The combination of optimal position of normal open switches can be found by moving tie along the direct path connecting two feeders related to the open switch while the whole optimization problem is separated into many small problems. The proposed algorithm is shown by case study results that, it is simple and takes short calculation time to apply to the DAS (Distribution Automation System) in KEPCO (Korea Electric Power Cooperation).

Analytical model for the prediction of the eigen modes of a beam with open cracks and external strengthening

  • Ovigne, P.A.;Massenzio, M.;Jacquelin, E.;Hamelin, P.
    • Structural Engineering and Mechanics
    • /
    • v.15 no.4
    • /
    • pp.437-449
    • /
    • 2003
  • The aim of this study is to develop an analytical model of a beam with open cracks and external strengthening which is able to predict its modal scheme components (natural frequencies and mode shapes). The model is valid as far as the excitation level is low enough not to activate non linear effects. The application field of the model are either the prediction of the efficiency of the reinforcement or the non destructive assessment of the structural properties. The degrees of freedom associated to the fault lips must be taken into account in order to introduce the effect of the external strengthening. In a first step, an analytical formulation of a beam with thin notches is proposed according to the references. The model is then extended to incorporate the strengthening consisting in a longitudinal stiffness applied in the vicinity of the cracks. In a second step, the analytical results are compared with these obtained from a finite element simulation.

A Study of Over Voltage Ground Relay Operation Status at Opening of No-load Charged Cable (무부하 충전케이블 개방시 잔류전압에의한 과전압계전기 동작현상 연구)

  • Kim, Yeong-Han;Choi, Jong-Hyuck;Yoon, Ki-Seob
    • Proceedings of the KIEE Conference
    • /
    • 2000.07a
    • /
    • pp.185-187
    • /
    • 2000
  • Fault current is flowed into 154/23kV M. Tr when line-to-ground fault occurs in power system. NGR(Neutral Grounded Reactor) is set up in order to prevent M.Tr fault by limiting magnitude of fault currents. Here, disconnection of NGR causes voltage increase by L-C resonance and line-to-ground fault in an unearthed system results in voltage increase at healthy phases. So Over Voltage Ground Relay(OVGR) is used for tripping M.Tr. Also, buses at second phases of M.Trs are all connected with section circuit breakers closed for the purpose of parallel operation and load shedding. In case of speciality buses are comprised of power cable in part for GIS connection. When no-load charged cable or bus is open by a section CB, unbalanced voltage charged on the bus is induced. Also discrepant opening time for circuit breakers on different phases gives rise to unbalanced zero sequence voltage. It was observed that this zero sequence voltage detected in the 22.9kV P.T (Potential Transformer for bus) mal-operated 59GT and tripped M.Tr. The zero sequence voltage of which vanishing time is longer than relay operating time came out by EMTDC simulation. Also, it was shown that the voltage waves of actual test are similar to those of simulation. On the basis of above results, R-C circuit complement on the relay without any effect on a power system made operating time of the relay longer than vanishing time of distorted waves. Consequently, operating time of the relay was delayed and magnitude of distorted waves was decreased by increasing time constant of the relay.

  • PDF