• Title/Summary/Keyword: Open and Closed

Search Result 1,788, Processing Time 0.033 seconds

Finite Element Analysis of Glass Lens Forming Process Using Open Die (개방형 금형을 이용한 유리 렌즈 성형 해석)

  • 나진욱;임성한;전병희;오수익
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2003.05a
    • /
    • pp.143-147
    • /
    • 2003
  • Despite of outstanding optical performance of glass lens, glass lens have not been widely used because of poor productivity and high cost due to manufacturing process i.e. grinding, polishing. However, press-forming method of glass lens overcomes this disadvantage because of mass production. When glass lens is produced by press-forming method using closed die, it is needed that the volume of glass lens preform precisely measured in order to prevent incomplete products and to increase in life of die. The present paper shows the shortcoming of forming process with closed die, and performs FEM simulation of forming process with open die in order to overcome this shortcoming. The design parameter of open die is selected in standard of assembly with optical module and maintenance of optical performance. FEM simulation is carried out with selected parameter of open die and two basic preform. According to distribution of effective strain in glass lens, optical property of glass lens formed at each set of die and preform is compared.

  • PDF

Finite Element Analysis of Glass Lens Forming Process Using Open Die (개방형 금형을 이용한 유리 렌즈 성형 해석)

  • 나진욱;임성한;오수익;전병희
    • Transactions of Materials Processing
    • /
    • v.12 no.4
    • /
    • pp.296-301
    • /
    • 2003
  • Though a glass tens has outstanding optical performance, it has not been widely used because manufacturing process shows poor productivity and high cost. However, press-forming method of glass lens overcomes these disadvantages with mass production. When glass lens is produced by press-forming method using closed die, it is needed that the volume of glass lens preform is precisely measured in order to prevent incomplete products and to increase in life of die. The present. paper shows the shortcoming of forming process with closed die, and performs FEM simulation of forming process with open die in order to overcome this shortcoming. The design parameters of open die are selected on the basis of assembly with optical module and maintenance of optical performance. FEM simulation is carried out with selected parameter of open die and two basic preform. According to distribution of effective strain in glass lens, optical property of glass lens formed at each set of die and preform is compared.

Automatic Protection Schemes for Distribution System with Open and Closed-loop

  • Guan, Kang-Le;Lee, Seung-Jae;Choi, Myeon-Song
    • Journal of Electrical Engineering and Technology
    • /
    • v.8 no.5
    • /
    • pp.969-974
    • /
    • 2013
  • Protection issues in distribution systems which are to be operated in open and closed-loop modes in a smart grid are studied and a generalized protection setting method is proposed to meet the new requirements. The developed setting method assumes a conventional over-current protection scheme for the system with reclosers and over-current relays. In a closed-loop mode, it identifies protective devices that have to be sacrificed in order to maximize protection coordination for bidirectional fault current flow. The proposed setting method has been tested on many systems with different complexity and is proved effective.

Buckling conditions and strengthening by CFRP composite of cylindrical steel water tanks under seismic load

  • Ali Ihsan Celik;Mehmet Metin Kose;Ahmet Celal Apay
    • Earthquakes and Structures
    • /
    • v.27 no.2
    • /
    • pp.97-111
    • /
    • 2024
  • In this paper, buckling conditions and retrofitting of cylindrical steel water storage tanks with different roof types and wall thicknesses were investigated by using finite element method. Four roof types of cylindrical steel tanks which are open-top, flat-closed, conical-closed and torispherical-closed and three wall thicknesses of 4, 6 and 8 mm were considered in FE modeling of cylindrical steel tanks. The roof shapes significantly affect load distribution on the tank shell under the seismic action. Composite FRP materials are widely used for winding thin-walled cylindrical steel structures. The retrofitting efficiency of cylindrical steel water tank is tested under the seismic loading with the externally bonded CFRP laminates. In retrofitting of cylindrical steel tank, the CFRP composite material coating method was used to improve of seismic performance of cylindrical steel tanks. ANSYS software was used to analyze the cylindrical steel tanks and maximum equivalent (von-Mises) and directional deformation were obtained. Equivalent (von-Mises) stresses significantly decreased due to the coating of the tank shell with FRP composite material. In thin-walled steel structures, excessive stress causes buckling and deformations. Therefore, retrofitting led to decrease in stress, reductions in directional and buckling deformation of the open-top, flat-closed, conical-closed and torispherical-closed tanks.

Film: Ending of a Story and an Open Ending (영화, 이야기의 결말과 열린 결말)

  • Kim, Sam-Ryeok
    • The Journal of the Korea Contents Association
    • /
    • v.19 no.7
    • /
    • pp.47-53
    • /
    • 2019
  • This study is an analysis of endings of films and open endings. Particularly, the key of this study is the investigation of the definition and interpretation of open endings. For this purpose, the 'ending' was defined first, and subsequently, endings were divided into 'closed' and 'open' endings with a goal pursuit model of David Howard and Robert McKee. Thus, it was found in this study that the thoughts of an audience as well as the intention of a creator are crucial in defining an ending. Although a story is designed by a creator, its interpretation is at the disposal of an audience in the end, and the audience may take an ending differently depending on their value system or interest in the story, which eventually leads to their own definition of the ending. For sure, a traditional fact is that most of films including those mentioned to have open endings have closed endings, and such a structure of stories will not change significantly in the future. However, the ending of a film designed to have a closed ending may be changed to be open ended depending on the intention of a creator or the thoughts of an audience, and furthermore, the intention of an open ending may not be readily accepted by an audience.

Closed Manual Reduction of Mandibular Condylar Fracture Assisted by C-arm Fluoroscopy (C-arm 형광투시를 이용한 하악관절돌기골절의 비관혈적 도수정복)

  • Choi, Eui Chul;Kang, Sang Gue;Jung, Sung Gyun
    • Archives of Craniofacial Surgery
    • /
    • v.10 no.2
    • /
    • pp.131-134
    • /
    • 2009
  • Purpose: Mandible fractures are common in maxillofacial trauma and the incidence of condylar fracture is high. The management of mandibular condylar fracture continues to be controversial. Conservative treatment of it may lead to complications such as asymmetry, malocclusion, temporomandibular joint dysfunction. Moreover, open reduction can cause facial nerve injury, parotid gland injury, scarring and hematoma formation. We present a case of mandibular condylar fracture that was treated by manual reduction without incision under C-arm fluoroscopy. Methods: A 76-year-old female was admitted due to left side mandibular condylar fracture that required surgical intervention. Because of her age, history of diabetes mellitus, hypertension, she underwent closed manual reduction under general anesthesia. We adopted C-arm fluoroscopy as a method of identifying the fracture site and a evaluation of reduction state. C-arm fluoroscopy was set up like modified Towne's view. Results: The reduction was successful and didn't result in any complications that could occur in open reduction-facial nerve injury, infection, parotid gland injury, hematoma, avascular necrosis. The mandibular-maxillary fixations were removed after 4 weeks and patients were could open 3.5 cm after 6 weeks with physical therapy. Conclusion: We tried closed manual reduction of mandibular condylar fracture due to high risk of complication using C-arm fluoroscopy and did achieve anatomic reduction with avoiding open incision. This is simple, effective, reversible, time saving and fairly attemptable method in condylar fracture cases before open reduction.

A Location-Routing Problem for Logistics Network Integrating Forward and Reverse Flow (역물류를 고려한 통합물류망에서의 입지:경로문제)

  • Na, Ho-Young;Lee, Sang-Heon
    • IE interfaces
    • /
    • v.22 no.2
    • /
    • pp.153-164
    • /
    • 2009
  • An effective management for reverse flows of products such as reuse, repair and disposal, has become an important issue for every aspect of business. In this paper, we study the Location-Routing Problem (LRP) in the multi-stage closed-loop supply chain network. The closed-loop supply chain in this study integrated both forward and reverse flows. In forward flow, a factory, Distribution Center (DC) and retailer are considered as usual. Additionally in reverse flow, we consider the Central Returns collection Center (CRC) and disposal facility. We propose a mixed integer programming model for the design of closed-loop supply chain integrating both forward and reverse flows. Since the LRP belongs to an NP-hard problem, we suggest a heuristic algorithm based on genetic algorithm. For some test problems, we found the optimal locations and routes by changing the numbers of retailers and facility candidates. Furthermore, we compare the efficiencies between open-loop and closed-loop supply chain networks. The results show that the closed-loop design is better than the open one in respect to the total routing distance and cost. This phenomenon enlarges the cut down effect on cost as an experimental space become larger.

The Study of the Compatibility of MSDS for the Classification of Flammable Materials (위험물의 분류를 위한 MSDS 이용의 적정성 연구)

  • Kwon, Kyung-Ok
    • Fire Science and Engineering
    • /
    • v.21 no.3
    • /
    • pp.56-60
    • /
    • 2007
  • The usage of MSDS (Material Safety Data Sheet) is increased world widely for the implementation of GHS and REACH. In order to know the accuracy of the data in MSDS the flash point of n-Decanol was measured by using a Tag closed tester, a Seta-flash closed tester, a Pensky-Martens closed tester and a Cleveland open tester in Japan and Korea, respectively. The test results of flash points of n-Decanol purchased different manufacturer were compared to the data of the references and MSDS. The flash points determined in Japan were similar to those in Korea but have shown much difference from those in MSDS and literatures. It is suggested that the results of flash points determined in this research have validity and manufacturers should be more careful when they make MSDS as well as for the classification of GHS and REACH.

MRI findings of the antero-superior attachment of the disc in TMJ internal derangement (측두하악관절 내장증에서의 관절원판 전상방부착부의 자기공명영상)

  • Cho Bong-Hae;Jung Yun-Hoa
    • Imaging Science in Dentistry
    • /
    • v.36 no.2
    • /
    • pp.73-79
    • /
    • 2006
  • Purpose : To describe the MRI findings of the antero-superior attachment of the disc in patients with internal derangement. Materials and Methods : One hundred fifty-six MR images from 40 normal subjects and 55 abnormal subjects were classified into three study groups of normal, anterior disc displacement with reduction and anterior disc displacement without reduction. On both closed- and open-mouth proton density sagittal images, the depiction of the antero-superior attachment of the disc and its demarcation from the disc were evaluated in three cuts of lateral, central and medial one thirds of the condyle. Results : The depiction of antero-superior attachment was more frequent by the order of normal, anterior disc displacement with reduction and anterior disc displacement without reduction groups, and the significant differences were found on lateral cut of the closed images and lateral and central cuts of the open images. In study for the demarcation between the antero-superior attachment and the disc the lateral cut of the closed images and all three cuts of the open images showed significant differences. Conclusion : Open images are useful to show the difference in depiction of the antero-superior attachment of the disc among the TMJ groups.

  • PDF

Comparison of a Closed with an Open Endotracheal Suction: Costs and the Incidence of Ventilator-associated Pneumonia (비용, 인공환기관련폐렴 발생 빈도에 있어서의 개방 기관내 흡인술에 대한 폐쇄 흡인술의 비교)

  • Jung, Jae Woo;Choi, Eun Hee;Kim, Jin Hee;Seo, Hyo Kyung;Choi, Ji Yeon;Choi, Jae Cheol;Shin, Jong Wook;Park, In Won;Choi, Byoung Whui;Kim, Jae Yeol
    • Tuberculosis and Respiratory Diseases
    • /
    • v.65 no.3
    • /
    • pp.198-206
    • /
    • 2008
  • Background: Tracheobronchial suctioning using the closed suctioning system has physiological benefits for critically ill patients. Despite these benefits, there are concerns about increased colonization of tracheobronchial tree by pathogenic organisms. The cost is another hinder to the introduction of closed suction system. The aim of this study was to evaluate the incidence of colonization and ventilator associated pneumonia and the cost-effectiveness of closed suction compared with open suction. Methods: During separated one month period, patients admitted MICU were cared by multiple-use, open suction, single-use, open suction and multiple-use, closed suction method, consecutively. Costs, colonization of tracheobronchial tree by MRSA and the incidence of ventilator-associated pneumonia (VAP) were analyzed. Results: One-hundred and six patients were enrolled. Twenty patients were treated with multiple-use, open suction, while 42 and 44 patients were cared with single-use, open catheter and multiple-use, closed catheter, respectively. Colonization by MRSA and the incidence of VAP were not different among three ways of suctioning. The overall costs per patient per day for suctioning were $10.58 for multiple-use, open suction, $28.27 for single-use, open suction and $23.76 for multiple-use, closed suction. Conclusion: Multiple-use, closed suctioning, when suction catheters were changed every 48 hrs, has the similar incidence of colonization of MRSA and occurrence of VAP and is a cost-efficient way of endotracheal suction.