• 제목/요약/키워드: Open Water Condition

검색결과 224건 처리시간 0.028초

이상강우에 대비한 성주댐의 홍수조절 능력 분석 (Evaluation of Flood Control Capacity for Seongju Dam against Extreme Floods)

  • 권순국;한건연;서승덕;최혁준
    • 한국농공학회지
    • /
    • 제45권6호
    • /
    • pp.109-118
    • /
    • 2003
  • As a fundamental research to establish a safety operation plan for irrigation dams, this study presents hydrologic analysis conducted in Sungju Dam watershed based on various rainfall data. Especially those reservoirs without flood control feature are widely exposed to the risk of flooding, a safe and optimized operation program need to be improved against arbitrary flooding. In this study, reservoir routing program was developed and simulated for reservoir runoff estimation using WMS hydrology model. The model simulated the variations of reservoir elevation under the condition of open or closed emergency gate. In case of closed emergency gate, water surface elevation was given as 193.15 m, and this value exceeds the dam crest height by 1.65 m. When the emergency gate is open, the increment of water surface elevation is given as 192.01 m, and this value exceeds dam crest height by 0.57 m. As an alternative plan, dam height increase can be considered for flood control under the PMP (Probable Maximum Precipitation) condition. Since the dam size is relatively small compare to the watershed area, sound protection can be expected from the latter option rather than emergency gate installation.

타 단독 특성의 이론적 해석 (Theoretical Analysis of Open Water Characteristics of a Rudder)

  • 공인영;강창구;이창민
    • 대한조선학회논문집
    • /
    • 제29권1호
    • /
    • pp.29-42
    • /
    • 1992
  • Spade Type 타의 단독 특성을 추정하기 위하여 3차원 Panel Method를 사용하였다. 입사류는 균일하며 시간에 따라 변하지 않는다고 가정하였고, 타 표면에 쏘오스 및 다이폴을 분포하였다. 후류면은 타의 뒷날에서 물체로부터 떨어져 나간다고 가정하였으며, 후류면에는 다이폴을 분포하였다. 후류면은 물체의 뒷날과 무한 원방에서 적당한 조건을 부여함으로써 그 형상을 가정하였으며, 후류 형상의 차이가 최종 결과에 미치는 영향을 고찰하였다. 뒷날에서는 3차원 압력 Kutta 조건을 적용하였으며, 2차원 Kutta조건을 적용한 결과와 비교하여 보았다. Spade Type 타에 대한 계산을 수행하였으며, 실험 결과와 전반적으로 잘 일치함을 확인하였다. 본 연구에서 사용한 방법은 타의 초기 설계 단계에서 유용하게 사용할 수 있을 것이다.

  • PDF

개수로 흐름에서 조류 터빈의 최적 배열 (Optimal layout of tidal current turbine array in open channel flow)

  • 한지수;정재영;황진환
    • 한국수자원학회:학술대회논문집
    • /
    • 한국수자원학회 2021년도 학술발표회
    • /
    • pp.433-433
    • /
    • 2021
  • 본 연구는 개수로 흐름에서 조류발전단지의 터빈 최적 배열의 거시적 특성에 관한 연구를 수행하였다. 천수방정식을 통해 직사각형 개수로의 흐름장을 해석하였고, 상류와 하류단에 대해 각각 유입경계조건(inlet boundary condition)과 Flather 형식의 개방경계조건(open boundary condition)을 부여하여 일정 유량으로 흐르는 개수로 흐름을 구현하였다. 더불어, Strickler의 법칙을 확장한 반력공식을 연계하여, 개수로 흐름에 대한 조류 터빈의 영향을 반영하였다. 주어진 상류의 흐름 조건에 대해 조류발전량을 최대로 하는 최적 배열을 구하기 위해 터빈 반력모형을 연계한 천수방정식, 터빈간 최소간격, 그리고 발전단지영역을 제한조건으로 하는 발전량 최대화 문제를 구성하였다. 여기서 조류 터빈의 위치를 나타내는 벡터를 설계변수로 두었는데, 설계되는 터빈의 수가 증가함에 따라 최적화 문제의 계산량이 증가하지 않도록 수반법(adjoint method)을 경사도기반법(gradient-based method)에 연계한 방법이 이용되었다. 다수의 터빈초기배치로 상당한 수치실험이 수행되었고, 발전량 최대화를 이루도록 최적화된 터빈의 배치들이 큰 규모에서 고유한 형상으로 수렴함을 확인하였다. 이러한 특성은 발전단지의 너비와 터빈의 최소간격의 함수로 정의된 무차원수 E를 바탕으로 설명되었다. 구체적으로, E가 1보다 작을 때에는 선형배열이 최적배열로 나타났고, E가 1을 넘어 점차 커짐에 따라 하류에 오목한 형상을 보이다가 V-형태로 발전하는 양상을 보였다. 또한, 어느 임계 수 이상의 터빈이 배치되는 경우 일열 배열을 유지하지 못하고 이열 배열로 분리됨이 관찰되었다.

  • PDF

쇄빙 유조선과 일반 유조선의 저항특성 비교연구 (Comparison Study on the Resistance Characteristics of an Arctic Tanker and a General Tanker)

  • 김현수;하문근;안당;전호환
    • 대한조선학회논문집
    • /
    • 제43권1호
    • /
    • pp.43-49
    • /
    • 2006
  • The hull form of icebreaking tanker depends on the trade route and ice characteristic. The hull form has to be designed for icebreaking concept if the vessel is operating in heavy ice and also the hull from has to be optimized for general tanker when the ship is operating in ice-free ocean. This paper presents comparison of ship resistance in pack ice, level ice and open water. Four ships are used to compare the resistance characteristic. One is conventional tanker and three ships are icebreaking tankers. The ice model test was carried out at the IOT (Institute for Ocean Technology, Newfoundland, Canada) and open water test was performed at 55MB (Samsung Ship Model Basin). The ice resistance of conventional tanker was predicted by Colbourne's method. The resistance of open water, pack ice and level ice are compared and discussed. The best hull form of icebreaker is not good in open water performance compare to conventional tanker. This result explains that the hull form of icebreaker and normal tanker have to compromise when the ship is operated in ice and ice-free condition. The result of this paper gives a guide for icebreaking tanker design.

수리실험에 의한 조력발전용 수문의 유량계수 산정에 관한 고찰 (Study on the Estimation of Discharge Coefficient of Sluice for Tidal Power Generation by Performing Physical Experiment)

  • 오상호;이광수;이달수;장세철
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2011년도 추계학술대회 초록집
    • /
    • pp.160.1-160.1
    • /
    • 2011
  • In this study, the influence of methodology of assessing water levels on the discharge coefficient of sluice for tidal power generation was investigated. A physical experiment was performed in a planar open channel by installing 1/70 scale model of the sluice caisson in the planar open channel. In front of and behind the sluice model, sloping bathymetry was made to reproduce corresponding field condition. By analyzing the experimental results, it was found that the location of measuring water levels significantly affects the estimates of the discharge coefficient, due to the variability of the parameter according to the head difference between the measuring locations. Therefore, it is necessary to be careful in estimating and utilizing the discharge coefficient in the relevant study of a tidal power generation.

  • PDF

Influence of Manufacturing Environment on Delamination of Mixed Cross Laminated Timber Using Polyurethane Adhesive

  • SONG, Dabin;KIM, Keonho
    • Journal of the Korean Wood Science and Technology
    • /
    • 제50권3호
    • /
    • pp.167-178
    • /
    • 2022
  • To investigate the influence of manufacturing environment on bonding performance of mixed cross laminated wood (CLT) using polyurethane (PUR) adhesive, a boiling water soak delamination test according to the temperature and relative humidity was conducted. The 5-ply mixed CLT consisted of Japanese Larch for external and middle layer and yellow poplar for internal layer. The PUR adhesives with different opening times of 10 and 30 minutes were used. The mixed CLT was manufactured according to pressing times of PUR and manufacturing environments of summer and winter. In case of summer environment, the delamination rate of the mixed CLT with pressing time of 4 hours using a PUR adhesive with open time of 10 minutes met the requirements of KS F 2081. In case of winter environment, the delamination rate of the mixed CLT didn't meet the requirements of KS standard. However, it was possible to confirm the effect of improving the adhesive performance by adjusting the pressing time according to the open time of the adhesive under the manufacturing conditions. The delamination rate of CLT with open time 30 minutes PUR, manufactured by indirect moisture supply methods was 11.2% better than direct moisture supply methods. As a result of delamination test in the same condition of relative humidity and adhesive, it was found that the temperature of manufacturing environment influences the adhesive performance.

침수식생 개수로에서 난류 및 부유사 이동 특성 (Characteristics of Turbulent Flows and Suspended Sediment Transport in Open-channel with Submerged Vegetation)

  • 양원준;장지연;최성욱
    • 한국수자원학회논문집
    • /
    • 제44권5호
    • /
    • pp.417-427
    • /
    • 2011
  • 침수식생 개수로 흐름은구조적으로상부영역과식생영역으로구분되는데, 상부영역은 일반 개수로의 흐름특성을 보이며 식생영역은 줄기에 의해 난류가 억제되어 정수식생 조건의 흐름과 유사하게 단순한 흐름특성을 보인다. 본 논문은 침수식생 개수로 흐름의 난류 및 유사이동 특성에 관한 실험연구이다. 이를 위해 폭 0.5m, 길이 12m인 개수로 실험장치를 이용하여수리실험을 실시하였다. 다양한 유량에 대하여 수심비 2~3인 흐름을 구현하였고, 나무원형 실린더를 이용하여 식생을 재현하였다. 평형상태에서 부유사 농도 분포를 측정하기 위해서중앙입경이 75 ${\mu}M$인 모래를 한계조건에 도달하기까지 지속적으로 투입하였다. 유속 성분의 계측을 위하여 레이저 도플러 유속계를 사용하였고, 튜브를 이용한 사이포닝 방식으로 시료를 직접 채취하여 부유사 농도를 측정하였다. 측정된 자료를 이용하여 실험조건에 따른 평균흐름과 난류량의 특성을 살펴보았고, Rouse 수에 따른 부유사 농도 분포를 제시하였다.

폐색 저감형 산기관의 개발 및 적용성 평가 (A study on the Development and Evaluation of Sludge Occlusion Reduced Diffuser)

  • 김영훈;김관엽;이의종;남종우;이창하;전민정;김형수
    • 상하수도학회지
    • /
    • 제25권1호
    • /
    • pp.41-49
    • /
    • 2011
  • The diffuser which is conventionally adapted to MBR, has problem that decreasing the cleaning effect of membrane module by inflexible air supply due to the occlusion of sludge from diffuser hole. To solve this problem, diffuser structure of submerged module should be improved to discharge sludge which is flow into the diffuser for prevent occlusion in the diffuser. In this study, the structure of the diffuser was reformed to open lower part for preclusion the blocking. And the outlet diameter of the diffuser was drawn through the condition for the depth of water and air rate, to prevent air-leak condition of improved diffuser. Moreover, application is evaluated by comparing test with occlusion effect of the conventional and improved diffuser. From the results, air-water boundary changes are steady with changes of water depth and it shows linear relation about air rate. By using this linear numerical formula, the height of diffuser's outlet can be decided. Also, it displays that it can prevent the occlusion effect during the comparing test. Hereafter, if this diffuser is applied to practical MBR process, the occlusion problem of diffuser will be disappeared.

소규모 개방형 사무실 배경 소음 레벨에 따른 최적 물소리 마스킹 레벨 (Preferred masking levels of water sounds according to various noise background levels in small scale open plan offices)

  • 김태희;이상현;윤채현;심효원;홍주영
    • 한국음향학회지
    • /
    • 제42권6호
    • /
    • pp.617-626
    • /
    • 2023
  • 개방형 사무실에서 소음과 스피치 프라이버시 문제는 꾸준히 제기되어 왔다. 이러한 개방형 사무실의 문제점을 해결하기 위한 마스킹 음원에 대한 연구가 필요하다. 따라서 본 연구에서는 청취 실험을 통하여, 쾌적한 물소리를 마스킹 음원으로 제안하고자 한다. 먼저 다양한 소음 레벨에 대하여 음환경 쾌적도와 스피치 프라이버시를 고려한 최적 물소리 레벨에 대하여 고찰하고자 한다. 이후 최적 레벨의 물소리 도입이 업무효율성에 미치는 영향을 검정하고자 한다. 청취실험에서 사용된 사무실 소음은 실제 개방형 사무실에서 바이노럴 마이크를 활용해 녹음하였고, 헤드폰을 통해 피험자들에게 제시하였다. 청취실험 음원은 각각 3개의 등가 배경소음레벨(55 dBA, 60 dBA, 65 dBA)과 5개의 신호대잡음비[Signal to noise ratio(SNR) -10 dB, -5 dB, 0 dB, +5 dB, +10 dB]의 조합로 구성하였고, 각 음원에 대한 주관평가로 전체적인 음환경 쾌적도(Overall Soundscape Quality, OSQ)와 듣기 어려운 정도(Listening Difficulty, LD)를 평가하였다. 평가 결과 배경음 보다 물소리가 커질수록 LD는 증가하였지만 OSQ는 감소하였다. 특히 물소리가 사무실 소음 보다 클경우 도입 전보다 OSQ가 감소하였다. 따라서 OSQ와 LD를 고려하였을 때 소음레벨별 최적 SNR은 모든 소음레벨에 대하여, -5 dB로 나타났다. 이후 업무 효율성을 평가하기 위하여, 최적 레벨의 물소리 도입 전후에 인지능력(Cognitive performance)을 평가하였다. 평가 결과 최적 레벨의 물소리를 도입할 경우, 배경소음이 55 dBA에서는 인지능력평가 결과가 물소리 도입 전에 비해 감소하는 것으로 나타났으나, 60 dBA와 65 dBA에서는 증가하는 것으로 나타났다.

환경 및 섬유 특성이 멀티레이어 직물시스템의 투습성에 미치는 영향 (Effects of Relative Humidity and Fiber Properties on the Moisture Permeability of Multilayer Fabric Systems)

  • 이수현;박소현
    • 한국의류산업학회지
    • /
    • 제25권1호
    • /
    • pp.119-126
    • /
    • 2023
  • This study aimed to determine the effects of relative humidity and fiber properties on the moisture permeability of multilayer systems by measuring water vapor transmission in the overlapping condition of various fabrics. The results confirmed that the property of the fabric in contact with the humid environment affects the moisture permeability. If the layer facing the humid environment is hydrophobic and the layer facing the dry environment is superhydrophobic, water vapor transmission increases by up to 17.8% compared to the opposite conditions. Comparing the correction values of the water vapor transmission reflecting the thickness of the specimen under the multilayer condition showed that permeability was higher when the hydrophilic or hydrophobic layer was facing the humid environment. The opposite was true from the "push-pull" effect of absorption mechanism. In the case of moisture permeability, the more hydrophilic the surface facing the humid environment, the more permeable that water vapor diffuses and passes through. It was concluded that the "pull-push" effect, in which water vapor diffuses widely through the hydrophilic facing a humid environment and then passes through the hydrophobic layer, contributes to the improvement of permeability. Permeability differed according to the multilayer overlapping condition. When the relative humidity was high, the "pull-push" effect was insignificant. This is caused by water droplets absorption after the partial migration of water due to condensation. These results suggest that the overlapping conditions and properties of fabrics should vary depending on heavy sweating or not.