• Title/Summary/Keyword: Open Standard

Search Result 1,294, Processing Time 0.026 seconds

OpenGL ES 2.0 Emulation on Desktop PCs (데스크탑 상에서의 OpenGL ES 2.0 에뮬레이션)

  • Baek, Nakhoon
    • KIPS Transactions on Computer and Communication Systems
    • /
    • v.3 no.4
    • /
    • pp.125-128
    • /
    • 2014
  • OpenGL ES(OpenGL for Embedded System) 2.0 is one of the most widely used 3D graphics API(application progrma interface) standard for smart phones and tablet PCs at this time. During programming with this API, they prefer desktop environment rather than the target mobile environment, which has relatively low computing power. Thus, we need to emulate the OpenGL ES 2.0 API on the desktop PCs, where only OpenGL API libraries are available. In this paper, we present technical difficulties and their solutions to emulate OpenGL ES 2.0 on desktop PCs. Our final implementation of OpenGL ES 2.0 emulation library works on desktop PCs and passed over more than 96% of the official CTS(conformance test suites) to prove the correctness of our implementation. Additionally, for the commercially available benchmark programs, our implementation shows equivalent execution speeds to the previous commercial OpenGL ES 2.0 implementations.

A Transaction Analysis Model for OpenADR 2.0b Payload (OpenADR 2.0b 페이로드 트랜잭션 분석 모델 연구)

  • Choi, Min-Young;Lee, June-Kyoung;Lee, Kyoung-Hak
    • Journal of the Korea Convergence Society
    • /
    • v.8 no.3
    • /
    • pp.23-30
    • /
    • 2017
  • OpenADR is a national standard communication protocol of demand response service. OpenADR uses XML message, called a payload, to support logical transaction of demand response service. For this purpose, OpenADR defines a XML element as transaction identifier which is called requestID. Unfortunately, OpenADR 2.0b profile specification describes some information about requestID but, it is not enough for understanding properly. Ambiguous definition of payload transaction makes vulnerabilities of implementing VEN & VTN and confuses mapping OpenADR 2.0b protocol into other smart grid protocols. Therefore, this paper redefines payload transaction to solve an ambiguous information of OpenADR 2.0b profile specification, proposes a model of analyzing payload transaction, and shows how to detect a payload transaction vulnerability in real-world.

Design and Implementation of Buffer Management Method for Enhancing Performance of Open GIS Components (개방형 GIS 컴포넌트의 성능 개선을 위한 버퍼 관리 방법의 설계 및 구현)

  • Cho, Dae-Soo;Min, Kyoung-Wook
    • The KIPS Transactions:PartD
    • /
    • v.11D no.1
    • /
    • pp.51-60
    • /
    • 2004
  • In open GIS environment, a GIS client can access spatial data in different types of GIS sowers with the same Interfaces. This means that open GIS components software ensures the interoperability throughout the heterogeneous GIS servers. The user response time, however, tends to be increased, if the client makes use of the standard interfaces for data accesses that can ensure interoperability. This is because the format of spatial data accessed from a specific GIS server must be transformed into common format, such as Rowset in OLE/DB, which is compatible with the standard interfaces. In this paper, we develop efficient techniques for data buffering in GIS client to reduce the response time. We design the buffer management method, which Is based on the space partitioning, and Integrate buffer management components into MapBase, an open GIS component software. And we also, show that buffer management proposed in this paper yields significant performance improvement in GIS client.

SEJONG OPEN CLUSTER SURVEY (SOS). 0. TARGET SELECTION AND DATA ANALYSIS

  • Sung, Hwankyung;Lim, Beomdu;Bessell, Michael S.;Kim, Jinyoung S.;Hur, Hyeonoh;Chun, Moo-Young;Park, Byeong-Gon
    • Journal of The Korean Astronomical Society
    • /
    • v.46 no.3
    • /
    • pp.103-123
    • /
    • 2013
  • Star clusters are superb astrophysical laboratories containing cospatial and coeval samples of stars with similar chemical composition. We initiate the Sejong Open cluster Survey (SOS) - a project dedicated to providing homogeneous photometry of a large number of open clusters in the SAAO Johnson-Cousins' UBV I system. To achieve our main goal, we pay much attention to the observation of standard stars in order to reproduce the SAAO standard system. Many of our targets are relatively small sparse clusters that escaped previous observations. As clusters are considered building blocks of the Galactic disk, their physical properties such as the initial mass function, the pattern of mass segregation, etc. give valuable information on the formation and evolution of the Galactic disk. The spatial distribution of young open clusters will be used to revise the local spiral arm structure of the Galaxy. In addition, the homogeneous data can also be used to test stellar evolutionary theory, especially concerning rare massive stars. In this paper we present the target selection criteria, the observational strategy for accurate photometry, and the adopted calibrations for data analysis such as color-color relations, zero-age main sequence relations, Sp - MV relations, Sp - $T_{eff}$ relations, Sp - color relations, and $T_{eff}$ - BC relations. Finally we provide some data analysis such as the determination of the reddening law, the membership selection criteria, and distance determination.

A Conversion Process to IFC Files for Integrated Use of Open and Web-based BIM Quantities, Process, and Construction Costs in Civil Engineering

  • Lee, Jae-Hong;Hwang, Hee-Suk
    • Journal of the Korea Society of Computer and Information
    • /
    • v.24 no.10
    • /
    • pp.11-23
    • /
    • 2019
  • This paper designs and proposes a file conversion process to IFC file, the international standard file format for BIM, in order to ensure mutual compatability and manageability among users of commercial BIM modeling and design softwares in the civil engineering area. The proposed process insert additional properties consisting of the properties of quantity calculation codes and properties of CBS/OBS/WBS standard classification scheme, to the three dimensional object shape information of the converted IFC files, using add-in converters for commercial BIM modeling softwares. In addition, a process of integrated use of IFC files for open web-based quantity, process(4D), and construction cost(5D) management is additionally designed and implemented. Based on these works, the ultimate goal of this study is to propose a novel process for integrated use of open web-based quantity, process(4D), and construction cost(5D), from the design stage of BIM modeling to the final construction stage in the civil engineering area.

An Experimental Research on the Room Acoustical Environment of the Elementary School Classrooms (초등학교 교실의 음환경 평가에 관한 실험적 연구)

  • Haan, Chan-Hoon;Moon, Kyu-Chun
    • Journal of the Korean Institute of Educational Facilities
    • /
    • v.11 no.1
    • /
    • pp.5-14
    • /
    • 2004
  • Since 1990s in Korea, elementary school classrooms have been designed toward open education system in pursuit of variety of educational purpose. Also, the architectural designs of schools have been acomplished for individual school not based on the standard design code. The present paper aims to investigate the acoustic environment of existing classrooms and to compare the sound insulation capacity between the ordinary classrooms and the newly built classrooms for open education. The current acoustical situation of elementary classrooms was analyzed using field measurements and questionnaire survey. In order to this, Three elementary schools were selected which were built in 1978, 1996 and 2000 respectively. Room acoustical parameters including Reverberation time(RT), Definition(D50), Speech Intelligibility(RASTI), Transmission loss(TL) and STC were measured in a classroom in each elementary school classroom. Each measurement was undertaken with the windows and doors being open or closed. As the result, it was found that the transmission loss between rooms in open classrooms is, $5{\sim}6dB$ in average, inferior than the ordinary classrooms. The RASTI of 0.70 was measured in newly built classrooms which is better than old classrooms(0.70) and open classrooms(0.73). This was shown as same in the speech definition measurements. This results from the condition of sealing and airtightness of classrooms and floor materials. The results denote that open classrooms have poor acoustic condition in sound insulation and speech intelligibility.

Design and Implementation of Mobile 3D Bluetooth Engine based on OpenGL-ES (OpenGL-ES 기반의 모바일 3D 블루투스 엔진 설계 및 구현)

  • Cho, Jong-Keun;Kim, Jong-Min
    • Journal of Korea Game Society
    • /
    • v.6 no.1
    • /
    • pp.21-28
    • /
    • 2006
  • This study focused on design and implementation of Mobile 3D Bluetooth Engine based on OpenGL-ES. In Mobile 3D network game so far, there is a form the mainstream of wireless internet game using WAP and VM. But, VM game are popular because of an excessive communication expense problem for this mobile network game that occur when connect to wireless internet as point out to problem by it, that is, stand-alone game are very popular. This study introduce a mobile 3D Bluetooth Engine which is based on mobile 3D standard using OpenGL-ES to solve a mobile network game generally that occurs when connect to take pleasure a wireless internet from some people into a short distance.

  • PDF

Open Posterior Approach versus Arthroscopic Suture Fixation for Displaced Posterior Cruciate Ligament Avulsion Fractures: Systematic Review

  • Song, Jae-Gwang;Nha, Kyung-Wook;Lee, Se-Won
    • Knee surgery & related research
    • /
    • v.30 no.4
    • /
    • pp.275-283
    • /
    • 2018
  • Purpose: To compare the clinical outcomes between the open posterior approach and arthroscopic suture fixation for displaced posterior cruciate ligament (PCL) avulsion fractures. Methods: A literature search was performed on MEDLINE, EMBASE, and the Cochrane Library databases. The inclusion criteria were as follows: papers written in English on displaced PCL avulsion fractures, clinical trial(s) with clear description of surgical technique, adult subjects, a follow-up longer than 12 months and modified Coleman methodology score (CMS) more than 60 points. Results: Twelve studies were included with a mean CMS value of 72.4 (standard deviation, 7.6). Overall, 134 patients underwent the open posterior approach with a minimum 12-month follow-up, and 174 patients underwent arthroscopic suture fixation. At final follow-up, the range of Lysholm score was 85-100 for the open approach and 80-100 for the arthroscopic approach. Patients who were rated as normal or nearly normal in the International Knee Documentation Committee subjective knee assessment were 92%-100% for the open approach and 90%-100% for the arthroscopic approach. The range of side-to-side difference was 0-5 mm for both approaches. Conclusions: Both arthroscopic and open methods for the treatment of PCL tibial-side avulsion injuries resulted in comparably good clinical outcomes, radiological healing, and stable knees.

Analysis on TVOC Concentrations and Influence Factors of Newly-Built Apartments (신축 아파트의 총휘발성유기화합물 농도와 관련요인 분석)

  • Choi, Yoon-Jung;Kang, Mi-Ra;Lee, Hye-Min;An, Hye-Jung
    • Proceedings of the Korean Institute of Interior Design Conference
    • /
    • 2006.05a
    • /
    • pp.268-271
    • /
    • 2006
  • The purpose of this study was to identify the influence of living factors on TVOC(Total Volatile Organic Compounds) concentrations for newly-built apartments. The field measurements of TVOC concentrations were made totally 30 times(5 times per one subject house) in six apartment units in which residents recently moved. Those apartments authorized its business approval before May 2004, the Act of Indoor Air auality Management for multi-use facilities. The findings were as follows: The TVOC concentrations of the measured subject apartments ranged from about 1/10 of the recommended standard for multi-use facilities($400{\mu}g/m^3$) to up to 90 times as high as the standard. Since then, the Recommended Standard of Indoor Air Quality Management for newly-built apartment house was announced in December 2005. In accordance with this standard($2390{\mu}g/m^3$) it ranged from about 1/100 to up to 15 times as high as the standard. The subject house whose TVOC concentrations reduced below the recommendation standard in the shortest period had the largest amount of ventilation (all the windows were open for ventilation in the past three months) among ail measured houses. The reason of another house whose TVOC concentrations were much higher than the rest was fronted with new furniture in the room. It's recommended that they should open all the windows for at least three months for ventilation in newly-built houses, and it would be better to avoid remodeling than needs be.

  • PDF

TVOC Concentrations and Residents' Responses on Sick House Syndrome of Newly-Built Apartments (신축 아파트의 TVOC 농도 및 거주자의 새집증후군 반응)

  • Choi Yoon-Jung;An Hye-Jung;Kang Mi-Ra;Lee Hye-Min
    • Korean Institute of Interior Design Journal
    • /
    • v.15 no.4 s.57
    • /
    • pp.129-137
    • /
    • 2006
  • The purpose of this study was to identify the influence of living factors on TVOC(Total Volatile Organic Compounds) concentrations and personal factors to reduce the Sick House Syndrome for newly-built apartments. The field measurements of TVOC concentrations were made totally 30 times(5 times per one subject house) in six apartment units in which residents recently moved. Those apartments authorized its business approval before May 2004, the Act of Indoor Air Quality Management for multi-use facilities. The Questionnaire surveys of residents' subjective responses on the Sick House Syndrome were carried out in 2nd measurement of each house. Respondents consisted of 20 residents living in the measured houses. The findings were as follows: The TVOC concentrations of the measured subject apartments ranged from about 1/10 of the recommended standard for multi-use facilities($400{\mu}g/m^3$) to up to 90 times as high as the standard. Since then, the Recommended Standard of Indoor Air Quality Management for newly-built apartment house was announced in December 2005. In accordance with this standard($2390{\mu}g/m^3$) it ranged from about 1/100 to up to 15 times as high as the standard. The subject house whose TVOC concentrations reduced below the recommendation standard in the shortest period had the largest amount of ventilation (all the windows were open for ventilation in the past three months) among all measured houses. The reason of another house whose TVOC concentrations were much higher than the rest was fronted with new furniture in the room. There turned out to be no apparent relations between the TVOC concentrations and the residents' individual responses of Sick House Syndrome. The responses were serious in those who stayed in their new houses for a long period or had disease like allergy. It's recommended that they should open all the windows for at least three months for ventilation in newly-built houses, and it would be better to avoid remodeling than needs be.