• Title/Summary/Keyword: Open Door

Search Result 260, Processing Time 0.029 seconds

Comparison of Early Surgical Outcome between Unilateral Open-Door Laminoplasty and Midline Splitting Laminoplasty

  • Baek, Hyun-Chul;Kang, Suk-Hyung;Jeon, Sang-Ryong;Roh, Sung-Woo;Rhim, Seung-Chul
    • Journal of Korean Neurosurgical Society
    • /
    • v.41 no.6
    • /
    • pp.382-386
    • /
    • 2007
  • Objective : Various techniques of cervical laminoplasty have been developed to decompress the spinal canal in patients with multilevel cervical spondylotic myelopathy. This study compared the early surgical outcomes between unilateral open-door laminoplasty and midline splitting cervical laminoplasty. Materials and Methods : From March 2004 to August 2005, we performed cervical laminoplasty in 34 patients with cervical myelopathy. Of these patients, 24 were treated by unilateral open-door laminoplasty [open-door group] and 10 by midline splitting cervical laminoplasty [splitting group]. The mean duration of follow up was 9.2 months in the open-door group and 15.8 months in the splitting group. We retrospectively analyzed neurological outcomes using the Japanese Orthopedic Association [JOA] score, and compared the radiological changes between the two groups. Results : Postoperative JOA score and recovery rate were $13.29{\pm}4.01$ and $56.28{\pm}44.91%$ in the open-door group and $15.75{\pm}0.88$ and $72.69{\pm}19.99%$ in the splitting group. There was no statistical difference between the two groups [p>0.05]. Regarding the radiological assessment, the increase of postoperative axial canal area was $63.23{\pm}23.24%$ in the open-door group and $42.30{\pm}14.96%$ in the splitting group [p<0,05]. Conclusion : There was no statistical difference in the neurological outcome when the early surgical outcomes of the open-door group and the splitting group were compared. However, the open-door group showed wider cervical spinal canal areas than the splitting group.

Sound Quality analysis for Fuel Filler Door open system (연료주입구 Door open 음의 음질분석)

  • Park, D.C.;Lee, D.H.;Jung, S.G.
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2000.06a
    • /
    • pp.1467-1472
    • /
    • 2000
  • This paper describes an investigative study for Fuel Filler Door open sound. Using statistical method of analyzing jury preference data, we extract important factor for subjective feeling and also define sound quality index and sound quality guideline for development of fuel filler system.

  • PDF

A Study On The Relationship Characteristics Between Inborn(Myers-Brigg's Type Indicator: MBTI) and Acquired(Personality Adaptation Type: PAT) Factors of Personality (성격의 선천적 요인(MBTI)과 후천적 요인(PAT)의 관계특성 연구)

  • Oh, Soo-Hee
    • 한국사회복지학회:학술대회논문집
    • /
    • 2004.04a
    • /
    • pp.757-779
    • /
    • 2004
  • The purpose of study is to provide efficient initial approaches for counseling in social work practice settings. First, it attempts to identify the correlation between the Myers-Brigg's Type Indicator(MBTI), a personality index based on the theory of psychological typology, and Personality Adaptation Types(PAT) models. Second, it attempts to develop a counseling method which can be applied to the initial interview, using the paradigm of door to therapy such as "Open Door", "Target Door", and "Trap Door" based on the PAT theory. The result of the quantitative study showed the correlation between MBTI and PAT as follows: MBTI Extrovert and Feeling(E, F) type was statistically correlated to hysterical PAT. MBTI Extrovert, Intuition and Perceiving(E, N, P) type was statistically correlated to Obsessive-Compulsive PAT. In conclusion, this study finds that when a clinical social worker approaches a client with the client's MBTI personality type and an interventional personality adaptation theory approach such as "Open Door", "Target Door", or "Trap Door", the efficiency of communication is increased significantly.

  • PDF

Numerical Analysis on Features of Airflow through Open Door in Pressure Differential System (급기가압 제연시스템의 방연풍속 형성특성에 대한 수치해석적 분석)

  • Kim, Jung-Yup;Rie, Dong-Ho;Kim, Ha-Young
    • Proceedings of the SAREK Conference
    • /
    • 2008.11a
    • /
    • pp.463-468
    • /
    • 2008
  • The fact that the major cases of life casualties are from smoke in the fire accidents and the expected steep increase of skyscrapers, huge spaces, multiplexes and huge scaled underground spaces demand establishment of efficient smoke countermeasure. In pressure differential systems for smoke management, the speed of airflow through open door between accommodation and lobby should be maintained over 0.5m/s on the whole area of door to prevent smoke from infiltrate into evacuation root when the door is open for refuge. The numerical analysis on features of airflow through open door are carried out and the results are presented.

  • PDF

Estimating Door Open Time Distributions for Occupants Escaping from Apartments

  • Hopkin, Charlie;Spearpoint, Michael;Hopkin, Danny;Wang, Yong
    • International Journal of High-Rise Buildings
    • /
    • v.10 no.1
    • /
    • pp.73-83
    • /
    • 2021
  • The door open time, resulting from occupants evacuating from apartments, is an important parameter when assessing the performance of smoke ventilation systems in high-rise apartment buildings. However, the values recommended in UK design guidance appear to have limited substantiation. Monte Carlo simulations have been carried out considering variabilities in door swing time, flow rate and number of occupants. It has been found that the door open time can be represented by a lognormal distribution with a mean of 6.6, 8.7 and 11.1 s and a standard deviation of 1.7, 3.2 and 4.7 s for one, two and three-bedroom apartments, respectively. For deterministic analyses, it is proposed that the 95th percentile values may be adopted in line with recommended practice for other fire safety design parameters such as fuel load density and soot yield, giving door open times of 10 s to 19 s, depending on the number of bedrooms.

Shielding Effect according to the Direction of Control Room Door Opening during Radiography (방사선촬영 중 제어실 문의 열린 방향에 따른 차폐효과)

  • Choi, Weon-Keun;Kim, Jung-Hoon;Kang, Bo-Sun;Bae, Seok-Hwan;Lim, Chang-Seon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.11 no.9
    • /
    • pp.3347-3352
    • /
    • 2010
  • It is recommended that the door of control room is closed during radiography to protect a radiologic technologist. However, for those patients such as of emergency or pediatrics, the door must be kept open unavoidably to apply immediate medical administration and treatment on the potential case of emergency which could be happened through the course of radiography. In addition, it could be efficient by reducing patients waiting time when the door is open for a general case. This study was conducted to evaluate practical exposure rate to a radiologic technologist when the door is open during the radiography, and to find out the ways to minimize radiation exposure and to increase the efficiency simultaneously. Measuring practical exposure rate was fulfilled with glass dosimeter, and it was 2.02 mGy/week at the location of radiologic technologist under the condition that the door is open during the radiography, which was about 2.3 times higher than the 100 mR/week. It means that the considerable amount of scattered rays through the door opening, and increase exposure rate at the radiologic technologist. Hence we confirmed that a radiologic technologist probably overexposed if the door is open during the radiography. It was also confirmed by the Monte Carlo simulation that the exposure rate could be reduced up to approximately 1/100 by change only the door opening direction. In conclusion, since the proper door opening direction provides same shielding effect whether it is open or close, the door opening direction need to be considered when it is installed at radiography facilities.

TTL : An automatic door lock system utilizing time and applications (TTL : 시간과 어플리케이션을 활용한 자동 도어락 시스템)

  • Jung, Jin-young;Moon, Sangook
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2015.05a
    • /
    • pp.900-902
    • /
    • 2015
  • Doors are to be the most basics of our lives from opening, closing and even keeping our property. Hence, doors have been innovated to blend in and make our daily lives more convenient. However, we find it difficult to open and close the doors manually of offices or tour zones, where they open and close at a precise time everyday. To solve this, we added a dimension of time to previous Door Locks. By this, every door with this specific door lock will open and close at a certain time we want them to open or close. Also, through the application you can control the time or use it to open and close the doors remotely. In order to do this, we systemed the door lock time system based on Java Programing language to make it easy to communicate and open or close the doors through smart phone applications, with the C programming language for the ATmega128 which will open and close the doors.

  • PDF

Technical Modification and Comparison of Results with Hirabayashi's Open-door Laminoplasty

  • Kim, Young-Sung;Yoon, Seung-Hwan;Park, Hyung-Chun;Park, Chong-Oon;Park, Hyeon-Seon;Hyun, Dong-Keun
    • Journal of Korean Neurosurgical Society
    • /
    • v.42 no.3
    • /
    • pp.168-172
    • /
    • 2007
  • Objective : Hirabayashi's open-door laminoplasty is a good procedure to use to treat patients with myelopathy of the cervical spine; however, the authors have experienced problems in maintaining an open-window in cervical spines after the surgery. The authors developed a modified method of the expanded open-door laminoplasty and compared the radiological and clinical results with those of the classical method. Methods : In the modified method, wiring fixation with lateral mass screws on the contra lateral-side instead of fixing the paraspinal muscle or facet joint, as in the classical methods, was used in the open window of the cervical spine. Fifteen patients with cervical myelopathy were treated using the classical method and 12 patients were treated using the modified method. Preoperative and postoperative clinical conditions were assessed according to the Japanese Orthopedic Association (JOA) score. The radiological results were compared with the preoperative and postoperative computed tomography (CT) findings. Results : In both methods, the clinical results revealed a significant improvement in neurological function (p<0.001). Image analysis revealed that the cervical canals were continuously expanded in patients treated using the modified methods. However, authors have observed restenosis during the follow-up periods in 4 patients treated using the original method. Progression to deformity and spinal instability were not observed in any of the patients in the radiological results. Conclusion : Although analysis with a larger population and a longer follow-up period needs to be undertaken, our modified open-door laminoplasty has shown an advantage in better maintaining an open window in comparison with the Hirabayashi's open-door laminoplasty.

Door lock remote control system using Wi-Fi (와이파이를 이용한 도어락 원격제어 시스템)

  • Kim, Gi Bum;Kim, Dong Hyun
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2017.10a
    • /
    • pp.86-88
    • /
    • 2017
  • The digital door lock is an electronic door lock that uses a password system and has the function of automatically locking the door when the door is closed, thus eliminating the worry about the door lock. As the technology has gradually developed, various authentication technologies such as semiconductor key system, RFID, and fingerprint recognition have been introduced. However, there is a danger of copying the door lock key, and there are password stealing and infringement. In this paper, we develop a remote control system that can unlock or open a smartphone to supplement the user's risk. The system you are going to develop can use WiFi to check if the door is locked or open on your smartphone, and you can lock or unlock the door remotely.

  • PDF

Car-door-controlled collision protection system using proximity sensor (근접센서를 이용한 차량 도어 제어 충돌 방지 시스템)

  • Lee S.H.;Cho H.S.;Heo J.K.;Lee J.H.;Kim W.K.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.10a
    • /
    • pp.971-975
    • /
    • 2005
  • In this study, a car-door-controlled collision protection system using proximity sensor is proposed and its preliminary analysis and several preliminary experiments are conducted. The proposed system has three additional sub-components on the car-door that is, a pair of extra electro-magnetic actuator that are attached to the sliding bar of the open/close car-door four-bar mechanism, a proximity sensor that would be attached to the outside surface of the door which is likely to frequently contact to the object and a driving control circuit of the whole system. A proximity sensor is used to detect object close to the car-door, the driving control circuit provides actuating power command to the electro-magnets to generate braking force to stop the swing motion of the car-door. It is verified through kinematic analysis of the four-bar car-door open/close mechanism and through experiments that the magnitude of maximum electronic magnetic force could provide the braking force enough for this application. For this purpose, an electro-magnet driving circuit is implemented and tested. And also to increase the safety of the system a time delay circuit is implemented and tested.

  • PDF