• Title/Summary/Keyword: Open Control Valve

Search Result 109, Processing Time 0.029 seconds

A Heuristic Approach for Grading Operation of Hydraulic Excavator Systems using SMISMO Valve Configuration (SMISMO 밸브 구조를 채용한 유압식 굴삭기의 평탄화 작업을 위한 휴리스틱 접근)

  • Joh, Joongseon;Hwang, Cheol Min
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.30 no.11
    • /
    • pp.1153-1160
    • /
    • 2013
  • SMISMO valve configuration is now starting to draw attention of the researchers of the construction equipment industry to increase the fuel efficiency of their equipment like excavators and wheel-loaders. An open-loop control strategy for grading operation of hydraulic excavator systems using SMISMO valve configuration is investigated in this paper. Tabor's algorithm for 1 d.o.f. SMISMO system under the assumption of quasi-static operation is revealed as not adequate for multi d.o.f. system with large moment of inertia even though the motion of the system is slow. New parameters are proposed in this paper. It modifies Tabor's open-loop control strategy for the grading operation of hydraulic excavators using SMISMO valve configuration. A simulation-based parameter tuning method is also proposed. It uses GA (Genetic Algorithm) to find the best parameter values. Simulation study for a practical hydraulic excavator shows the validity of the proposed open-loop control strategy.

Characteristics of Capacity Control of Variable Speed Water Cooler with the Electronic Expansion Valve Open/Close Degree (전자팽창밸브 개도에 따른 가변속 수냉각기의 용량제어 특성)

  • Beak, Seung-Moon;Moon, Choon-Geun;Kim, Hyun-Woo;Jeong, Seok-Kwon;Yoon, Jung-In
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.34 no.2
    • /
    • pp.282-288
    • /
    • 2010
  • The paper presents the characteristics of capacity control of variable speed water cooler with the electronic expansion valve open/close degree. It is a preliminary study on the optimum control of the water cooler system using a variable speed compressor controlled by inverter. The electronic expansion valve controlled by the variation of compressor speed maintains the constant degree of superheat at the evaporator outlet, which aims to find the degree of superheat obtaining the optimum refrigeration effect. The investigation indicates that there is a point achieving the maximum cooling capacity by the variation of the electronic expansion valve open/close degree with constant compressor speed.

Design and Performance Test of Vacuum Control Valve for Electron Beam Lithography (전자빔 가공기의 진공제어 밸브설계 및 특성평가)

  • Lee Chan-Hong;Lee Hu-Sang
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.06a
    • /
    • pp.777-780
    • /
    • 2005
  • The high vacuum in a electron beam lithography is basic condition, because electron beam vanish by collision with air molecules in generally atmosphere. To make high vacuum state, the vacuum control valve is essential. Most vacuum control valve are manual units. So, user of manual vacuum valve must have understanding vacuum process to change from low vacuum to high vacuum state. The user of electron beam lithography are troubled with operation of manual vacuum valve, in case the vacuum chamber is frequently open. In this paper, the design and performance test of auto vacuum control valve for electron beam lithography are described. With the auto vacuum control valve, the high vacuum level can reach 2.8E-5 Torr.

  • PDF

A Study of Flow Characteristics in Pressure Independent Control Valve for Hydronic System (냉난방수배관시스템용 차압독립형 유량제어밸브의 유동특성 연구)

  • Min, Joon-Ki;Won, Bo-Young;Jeong, Shin-Kyu
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.13 no.3
    • /
    • pp.9-15
    • /
    • 2017
  • In this study, set values of PICV(Pressure Independent Control Valve) were simulated according to the pressure distribution and velocity. The higher the set value and the open rate, as the lower the pressure in the neck. On the contrary, the lower the set value and open rate, as the higher the pressure in the neck. When the set value was small, the pressure was distributed sufficiently and confirmed that the pressure was generated by the VOF, confirming that it could generate a vapor pressure. When the set value 100 %, the lower corn open rate of the differential pressure was 46 % to 29 %, set value 100 % was 29 % to 19 %, and set value 6 % was 12 % to 6 % for the lower corn open rate percentile, it was limited to within 50 %. Thus, the results of this study on the correlation between open rate and differential pressure of the set value of the PICV will be beneficial to improve performance of flow control valves and contribute to their efficient operation used for a hydronic system.

A Study on the Numerical Analysis of Internal Flow in a Cone Type Valve (Cone Type 밸브 내부유동 수치해석에 관한 연구)

  • Chin, Do-Hun
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.23 no.2_2
    • /
    • pp.199-207
    • /
    • 2020
  • These days, many different types of valves are developed in the industrial area according to their use purpose. Multiple kinds of valves are installed to control a flow and pressure of the pipe conveying fluid. Valves serve as critical roles in land plants such as power plants. The performance of equipment varies depending on valve characteristics. In this study, the internal flow analysis on Cone-type valve is conducted to analyze flow field and secure a value of the flow coefficient Cv. According to the internal flow analysis, when the flow distribution of the middle cross-section of valve was open 100%, flow field was relatively and smoothly taken out. If it was open 50%, flow recirculation region increased and a little complex flow field occurred. Unlike ball valve or butterfly valve, this valve had flow recirculation in its outlet depending on a valve opening amount. Therefore, it was found that there was no flow recirculation in the outlet of Cone-type valve.

LOW FUEL CONSUMPTION AND LOW EMISSIONS - ELECTROMECHANICAL VALVE TRAIN IN VEHICLE OPERATION

  • Pischinger, M.;Salber, W.;Staay, F.V.D.;Baumgarten, H.;Kemper, H.
    • International Journal of Automotive Technology
    • /
    • v.1 no.1
    • /
    • pp.17-25
    • /
    • 2000
  • The electromechanical valve train (EMV) technology allows for a reduction in fuel consumption while operating under a stoichiometric air-fuel-ratio and preserves the ability to use conventional exhaust gas aftertreatment technology with a 3-way-catalyst. Compared with an engine with a camshaft-driven valve train, the variable valve timing concept makes possible an additional optimization of cold start, warm-up and transient operation. In contrast with the conventionally throttled engine, optimized control of load and in-cylinder gas movement can be used for each individual cylinder and engine cycle. A load control strategy using a "Late Intake Valve Open" (LIO) provides a reduction in start-up HC emissions of approximately 60%. Due to reduced wall-wetting, the LIO control strategy improves the transition from start to idle. "Late Exhaust Valve Open" (LEO) timing during the exhaust stroke leads to exhaust gas afterburning and, thereby, results in high exhaust gas temperatures and low HC emissions. Vehicle investigations have demonstrated an improved accuracy of the air-fuel-ratio during transient operation. Results in the New European Driving Cycle have confirmed a reduction in fuel consumption of more than 15% while meeting EURO IV emission limits.

  • PDF

High-Precision Direct-Operated Relief Valve with a Variable Elasticity Spring (변탄성 스프링을 이용한 고정밀 직동형 릴리프 밸브)

  • Kim, SungDong
    • Journal of Drive and Control
    • /
    • v.17 no.4
    • /
    • pp.87-96
    • /
    • 2020
  • In this study, a variable elasticity spring was applied to improve the pressure control precision of conventional relief valves. The equilibrium equation of the forces acting on the valve poppet was derived; it is demonstrated that matching the elastic rate of the pressure-adjusting coil spring to the equivalent elastic rate of the flow force improved the pressure override. The procedures that were used to design the variable elasticity spring are presented, and some applications of the variable elasticity spring are also introduced. Computer simulations were used to analyze three cases: a poppet-closed flow force structure, a poppet-open flow force structure with a constant elasticity spring, and a structure containing a variable elasticity spring. It is confirmed that the pressure control precision of the relief valve can be significantly improved upon by applying a variable elasticity spring to the poppet-open flow force structure.

Liner Analysis of IMV Proportional Flow Control Valve Static Characteristics (IMV 비례 유량제어밸브 정특성 선형해석)

  • Jung, Gyuhong
    • Journal of Drive and Control
    • /
    • v.16 no.4
    • /
    • pp.56-64
    • /
    • 2019
  • Recently, as the environmental regulation for earth moving equipment has been tightened, advanced systems using electronic control have been introduced for energy savings. An IMV(Independent Metering Valve), which consists of four 2-way valves, is one of the electro-hydraulic control systems that provides more flexible controllability and potential for energy savings in excavators, when compared to the conventional 4-way spool valve system. To fully realize an IMV, a two-stage bi-directional flow control valve which can regulate the large amount of flow in both directions, should be developed in advance. A simple design that allows proportional flow control to apply the pilot pressure from the current-controlled solenoid to the spring loaded flow control spool and thus valve displacement, is proportional to the solenoid current. However, this open-loop type valve is vulnerable to flow force which directly affects the valve displacement. Force feedback servo of which the position loop is closed by the feedback spring which interconnects the solenoid valve and flow control spool, could compensate for the flow force. In this study, linearity for the solenoid current input and robustness against load pressure disturbance is investigated by linear analysis of the static nonlinear equations for the IMV proportional flow control valve with feedback spring. Gains of the linear system confirm the performance improvement with the feedback spring design.

Cam Profile Design for Impulsive Noise Reduction of Automotive Engine Valve Train (자동차 엔진 밸브트레인의 타음감소를 위한 캠 형상 설계)

  • An, Ki-Yong;Kim, Do-Joong
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.14 no.4
    • /
    • pp.139-148
    • /
    • 2006
  • Valve train is one of the important noise sources in idling engines. Valve train noise comes mostly from two different impacts. One is the impact between cam and tappet at the beginning of the valve open period, which is an important source of impulsive noise of valve trains. The other is the impact between valve and valve seat at the closing of the valve open period. In case of mechanical lash adjusters, it is very difficult to control the initial impact. In this paper, we designed various types of cam profiles, especially in the opening ramp design, and investigated the effect of cam profiles on the magnitude of the initial impact. The effects that some cam design parameters have on the impulsive noise are also observed.