• Title/Summary/Keyword: Onset Detection

Search Result 159, Processing Time 0.023 seconds

Development of a foaling alarm system using an accelerometer

  • Youngwook, Jung;Honghee, Chang;Minjung, Yoon
    • Journal of Animal Science and Technology
    • /
    • 제64권6호
    • /
    • pp.1237-1244
    • /
    • 2022
  • Horse breeders suffer massive economic losses due to dystocia, abortion, and stillbirths. In Thoroughbred mares, breeders often miss the foaling process because approximately 86% of the foaling events occur from 19:00 to 7:00; consequently, breeders cannot assist mares experiencing dystocia. To solve this problem, various foaling alarm systems have been developed. However, there is a need to develop a new system to overcome the shortcomings of the existing devices and improve their accuracy. To this end, the present study aimed to (1) develop a novel foaling alarm system and (2) compare its accuracy with that of the existing FoalertTM system. Specifically, eighteen Thoroughbred mares (11.9 ± 4.0 years old) were included. An accelerometer was used to analyze specific foaling behaviors. Behavioral data were transmitted to a data server every second. Depending on the acceleration value, behaviors were automatically classified by the server as categorized behaviors 1 (behaviors without change in body rotation), 2 (behaviors with sudden change in body rotation, such as rolling over), and 3 (behaviors with long-term change in body rotation, such as lying down laterally). The system was designed to alarm when the duration of categorized behaviors 2 and 3 was 12.9% and that of categorized behavior 3 was 1% during 10 min. The system measured the duration of each categorized behavior every 10 min and transmitted an alarm to the breeders when foaling was detected. To confirm its accuracy, the foaling detection time of the novel system was compared with that of FoalertTM. The novel foaling alarm system and FoalertTM alarmed foaling onset respectively 32.6 ± 17.9 and 8.6 ± 1.0 min prior to foal discharge, and the foaling detection rate of both systems was 94.4%. Therefore, the novel foaling alarm system equipped with an accelerometer can precisely detect and alert foaling onset.

Speech Perception and Gap Detection Performance of Single-Sided Deafness under Noisy Conditions

  • Kwak, Chanbeom;Kim, Saea;Lee, Jihyeon;Seo, Youngjoon;Kong, Taehoon;Han, Woojae
    • Journal of Audiology & Otology
    • /
    • 제23권4호
    • /
    • pp.197-203
    • /
    • 2019
  • Background and Objectives: Many studies have reported no benefit of sound localization, but improved speech understanding in noise after treating patients with single-sided deafness (SSD). Furthermore, their performances provided a large individual difference. The present study aimed to measure the ability of speech perception and gap detection in noise for the SSD patients to better understand their hearing nature. Subjects and Methods: Nine SSD patients with different onset and period of hearing deprivation and 20 young adults with normal hearing and simulated conductive hearing loss as the control groups conducted speech perception in noise (SPIN) and Gap-In-Noise (GIN) tests. The SPIN test asked how many presented sentences were understood at the +5 and -5 dB signal-to-noise ratio. The GIN test was asked to find the shortest gap in white noise with different lengths in the gap. Results: Compared to the groups with normal hearing and simulated instant hearing loss, the SSD group showed much poor performance in both SPIN and GIN tests while supporting central auditory plasticity of the SSD patients. Rather than a longer period of deafness, the large individual variance indicated that the congenital SSD patients showed better performance than the acquired SSD patients in two measurements. Conclusions: The results suggested that comprehensive assessments should be implemented before any treatment of the SSD patient considering their onset time and etiology, although these findings need to be generalized with a large sample size.

Speech Perception and Gap Detection Performance of Single-Sided Deafness under Noisy Conditions

  • Kwak, Chanbeom;Kim, Saea;Lee, Jihyeon;Seo, Youngjoon;Kong, Taehoon;Han, Woojae
    • 대한청각학회지
    • /
    • 제23권4호
    • /
    • pp.197-203
    • /
    • 2019
  • Background and Objectives: Many studies have reported no benefit of sound localization, but improved speech understanding in noise after treating patients with single-sided deafness (SSD). Furthermore, their performances provided a large individual difference. The present study aimed to measure the ability of speech perception and gap detection in noise for the SSD patients to better understand their hearing nature. Subjects and Methods: Nine SSD patients with different onset and period of hearing deprivation and 20 young adults with normal hearing and simulated conductive hearing loss as the control groups conducted speech perception in noise (SPIN) and Gap-In-Noise (GIN) tests. The SPIN test asked how many presented sentences were understood at the +5 and -5 dB signal-to-noise ratio. The GIN test was asked to find the shortest gap in white noise with different lengths in the gap. Results: Compared to the groups with normal hearing and simulated instant hearing loss, the SSD group showed much poor performance in both SPIN and GIN tests while supporting central auditory plasticity of the SSD patients. Rather than a longer period of deafness, the large individual variance indicated that the congenital SSD patients showed better performance than the acquired SSD patients in two measurements. Conclusions: The results suggested that comprehensive assessments should be implemented before any treatment of the SSD patient considering their onset time and etiology, although these findings need to be generalized with a large sample size.

Early Detection of Epiphytic Anthracnose Inoculum on Phyllosphere of Diospyros kaki var. domestica

  • Lee, Jung-Han;Han, Ki-Soo;Lee, Sun-Cheol;Shim, Chang-Ki;Bae, Dong-Won;Kim, Dong-Kil;Kim, Hee-Kyu
    • The Plant Pathology Journal
    • /
    • 제20권4호
    • /
    • pp.247-251
    • /
    • 2004
  • We developed a polyclonal antibody (PAh) based- ELISA system to accurately and rapidly monitor inocula on plant surface before onset of anthracnose. Titer of mouse antisera against conidia of Colletotrichum gloeosporioides was determined by using indirect ELISA. It was high enough to be detectable up to ${\times}$ 12,800 dilutions. Absorbance readings exceeded (1.5even at a 10$^{-5}$ dilution. Sensitivity of PAb was precise enough to detect spore concentration as low as 50 conidia/well by indirect ELISA. PAb1 and PAb2 proved to be very sensitive and highly specific to the target pathogen, C. gloeosporioides, apparently discriminating other unrelated pathogens, or epiphytes. Absorbance values for original isolate exceeded 1.0, but no reaction was detected with other isolates, except three other anthracnose fungi: C. gloeosporioides (pepper strain), Glomerella cingulata (apple strain) and C. lagenarium. Our data suggest that PAb1 and PAb2 bind with the protein epitope that partially contains residues of amino acid, arginine, and Iysine. This kit fulfills the require-ments for detecting inoculums before infection and during onset of anthracnose on sweet persimmon.

피로골절 환자에서 골주사 소견과 방사선 소견의 비교 (Radioisotopic and Radiological Evaluation in Patient with Stress Fracture)

  • 고광섭;김재영;강성구;김소연;이권전
    • 대한핵의학회지
    • /
    • 제21권1호
    • /
    • pp.39-46
    • /
    • 1987
  • The stress fracture is a disease caused by and abnormal stress to the normal bone with constant, repeated pull. Early detection of stress fracture plays an important role in treatment and prevention of its complication. Bone scintigraphy was performed to evaluate 18 patients with stress fracture of the lower extremities from May, 1985 to April, 1987, in the Department of Internal Medicine of National Police Hospital. The results were as follows: 1) Seventeen of the 18 cases showed positive bone scans at the initial study performed from 1 week to S months after the onset of symtom. 2) Ten of the 18 patients had findings of stress fracture at the initial X-ray film. Two out of 8 negative case revealed positive findings in the follow-up studies. 3) The bone scans in the 2 cases taken 5 months after the onset of symton; the one showed only slightly increased radiouptake, the other showed no abnormal findings. In conclusion, bone scanning is a more sensitive indicator of early stress fracture than radiologic study. The healing phase is characterized by a gradual decline in radioactivity at the fracture site in concordance with subsidence of symptom.

  • PDF

Distributed crack sensors featuring unique memory capability for post-earthquake condition assessment of RC structures

  • Chen, Genda;McDaniel, Ryan;Sun, Shishuang;Pommerenke, David;Drewniak, James
    • Smart Structures and Systems
    • /
    • 제1권2호
    • /
    • pp.141-158
    • /
    • 2005
  • A new design of distributed crack sensors based on the topological change of transmission line cables is presented for the condition assessment of reinforced concrete (RC) structures during and immediately after an earthquake event. This study is primarily focused on the performance of cable sensors under dynamic loading, particularly a feature that allows for some "memory" of the crack history of an RC member. This feature enables the post-earthquake condition assessment of structural members such as RC columns, in which the earthquake-induced cracks are closed immediately after an earthquake event due to gravity loads, and are visually undetectable. Factors affecting the onset of the feature were investigated experimentally with small-scale RC beams under cyclic loading. Test results indicated that both crack width and the number of loading cycles were instrumental in the onset of the memory feature of cable sensors. Practical issues related to dynamic acquisition with the sensors are discussed. The sensors were proven to be fatigue resistant from shake table tests of RC columns. The sensors continued to show useful performance after the columns can no longer support additional loads.

진동연소 발생에 관한 징후와 이의 검출 (Symptoms on Generation of Combustion Oscillation and their Detection)

  • 양영준
    • 에너지공학
    • /
    • 제13권3호
    • /
    • pp.205-213
    • /
    • 2004
  • 본 연구에서는 고가인 고속도 CCD카메라가 아닌 비교적 간단한 광파이버 시스템을 이용한 자려진동연소 발생에 관한 검출과, 진동연소가 발생하기 전에 이를 미리 예견할 수 있는 통계학적 수법에 관해 조사를 하였다. 먼저 자려진동연소의 발생시에 사용될 수 있는 광파이버의 유용성이 검증되었다. 광파이버에 의해 검출되어진 OH 라디칼 자발광 강도는 고속도 CCD카메라에 의해 얻어진 값과 강한 자려진동연소가 발생할 때에 거의 일치를 하였다. 자려진동연소가 발생하면 시스템과 연소기기에 손상을 가하게 된다. 이러한 피해가 발생하기 전에 자려진동연소의 발생 징후를 미리 포착하려는 시도를 하였다. 이를 위해 압력과 OH라디칼 자발광과 같은 화염에서의 변동성분께 대한 통계학적 처리를 이용하여 자려진동연소의 발생을 예견할 수 있는 독특한 수법에 관해 조사를 하였다.

실시간 동영상 시청시 주제탐색조건과 주제관련성이 내재적 유발전위 활성에 미치는 영향 (The Influence of Topic Exploration and Topic Relevance On Amplitudes of Endogenous ERP Components in Real-Time Video Watching)

  • 김용호;김현희
    • 한국멀티미디어학회논문지
    • /
    • 제22권8호
    • /
    • pp.874-886
    • /
    • 2019
  • To delve into the semantic gap problem of the automatic video summarization, we focused on an endogenous ERP responses at around 400ms and 600ms after the on-set of audio-visual stimulus. Our experiment included two factors: the topic exploration of experimental conditions (Topic Given vs. Topic Exploring) as a between-subject factor and the topic relevance of the shots (Topic-Relevant vs. Topic-Irrelevant) as a within-subject factor. For the Topic Given condition of 22 subjects, 6 short historical documentaries were shown with their video titles and written summaries, while in the Topic Exploring condition of 25 subjects, they were asked instead to explore topics of the same videos with no given information. EEG data were gathered while they were watching videos in real time. It was hypothesized that the cognitive activities to explore topics of videos while watching individual shots increase the amplitude of endogenous ERP at around 600 ms after the onset of topic relevant shots. The amplitude of endogenous ERP at around 400ms after the onset of topic-irrelevant shots was hypothesized to be lower in the Topic Given condition than that in the Topic Exploring condition. The repeated measure MANOVA test revealed that two hypotheses were acceptable.

단계별 기저선 정렬을 이용한 ECG 신호에서 P파와 T파 검출 알고리즘 (P-Waves and T-Wave Detection Algorithm in the ECG Signals Using Step-by-Step Baseline Alignment)

  • 김정홍;이승민;박길흠
    • 한국멀티미디어학회논문지
    • /
    • 제19권6호
    • /
    • pp.1034-1042
    • /
    • 2016
  • The detection of P-waves and T-wave in the electrocardiogram signal analysis is an important issue. But the accuracy of the boundary detection algorithm is an insufficient level in the change of slow transition in the signal compared to the QRS complex. This study proposes an algorithm to detect P-wave and T-wave sequentially after determining local baseline using QRS complex. First, we detected the peak points based on local baseline and determined the onset and offset through the calculation of the area of the section. After modifying the baseline using detected waveform, we detected the other waveform in the same way and separated the P-wave and the T-wave based on the location. We used the PhysioNet QT database to evaluate the performances of the algorithm, and calculate the mean and the standard deviations. The experiment results show that standard deviations are under the tolerances accepted by expert physicians, and outperform the results obtained by the other algorithms.

Application of principal component analysis and wavelet transform to fatigue crack detection in waveguides

  • Cammarata, Marcello;Rizzo, Piervincenzo;Dutta, Debaditya;Sohn, Hoon
    • Smart Structures and Systems
    • /
    • 제6권4호
    • /
    • pp.349-362
    • /
    • 2010
  • Ultrasonic Guided Waves (UGWs) are a useful tool in structural health monitoring (SHM) applications that can benefit from built-in transduction, moderately large inspection ranges and high sensitivity to small flaws. This paper describes a SHM method based on UGWs, discrete wavelet transform (DWT), and principal component analysis (PCA) able to detect and quantify the onset and propagation of fatigue cracks in structural waveguides. The method combines the advantages of guided wave signals processed through the DWT with the outcomes of selecting defect-sensitive features to perform a multivariate diagnosis of damage. This diagnosis is based on the PCA. The framework presented in this paper is applied to the detection of fatigue cracks in a steel beam. The probing hardware consists of a PXI platform that controls the generation and measurement of the ultrasonic signals by means of piezoelectric transducers made of Lead Zirconate Titanate. Although the approach is demonstrated in a beam test, it is argued that the proposed method is general and applicable to any structure that can sustain the propagation of UGWs.