• 제목/요약/키워드: One-Step

검색결과 4,648건 처리시간 0.043초

Scaling Factor Design Based Variable Step Size Incremental Resistance Maximum Power Point Tracking for PV Systems

  • Ahmed, Emad M.;Shoyama, Masahito
    • Journal of Power Electronics
    • /
    • 제12권1호
    • /
    • pp.164-171
    • /
    • 2012
  • Variable step size maximum power point trackers (MPPTs) are widely used in photovoltaic (PV) systems to extract the peak array power which depends on solar irradiation and array temperature. One essential factor which judges system dynamics and steady state performances is the scaling factor (N), which is used to update the controlling equation in the tracking algorithm to determine a new duty cycle. This paper proposes a novel stability study of variable step size incremental resistance maximum power point tracking (INR MPPT). The main contribution of this analysis appears when developing the overall small signal model of the PV system. Therefore, by using linear control theory, the boundary value of the scaling factor can be determined. The theoretical analysis and the design principle of the proposed stability analysis have been validated using MATLAB simulations, and experimentally using a fixed point digital signal processor (TMS320F2808).

Modified Asymmetrical Variable Step Size Incremental Conductance Maximum Power Point Tracking Method for Photovoltaic Systems

  • Tian, Yong;Xia, Bizhong;Xu, Zhihui;Sun, Wei
    • Journal of Power Electronics
    • /
    • 제14권1호
    • /
    • pp.156-164
    • /
    • 2014
  • The power-voltage (P-V) characteristic of a photovoltaic (PV) array is nonlinear and time varying with the change in atmospheric conditions. As a result, the maximum power point tracking (MPPT) technique must be applied in PV systems to maximize the generated energy. The incremental conductance (INC) algorithm, one of the MPPT strategies, is widely used for its high tracking accuracy, good adaptability to rapidly changing atmospheric conditions, and easy implementation. This paper presents a modified asymmetrical variable step size INC MPPT method that is based on the asymmetrical feature of the P-V curve. Compared with conventional fixed or variable step size method, the proposed method can effectively improve tracking accuracy and speed. The theoretical foundation and design principle of the proposed approach are validated by the simulation and experimental results.

ISO 14649 표준을 위한 신속조형용 설계정보모델 (A Rapid Prototyping Data Model for ISO 14649)

  • 김인배;지해성
    • 한국CDE학회논문집
    • /
    • 제10권4호
    • /
    • pp.225-236
    • /
    • 2005
  • The primary goal of the study is to provide a newly refined data model, an information exchange foundation of modeling operation for rapid prototyping, as one among non-milling STEP-NC modules. The previous data model has been first modified and refined by reflecting specific user requirements. Second, subsidiary information such as fabrication history as well as traditional process information has been introduced into the newly refined model in order to consolidate the model functionality. In short, the main contribution of the study is to provide a foundation where a newly refined data model is utilized easily and conveniently for practical rapid prototyping fabrication within the newly constructed STEP-NC environment.

고속유동장내 액체분열현상 (Phenomena of Liquid Jet Breakup in High Speed Gas Stream)

  • 박용국;석지권;이충원
    • 한국분무공학회지
    • /
    • 제1권2호
    • /
    • pp.66-73
    • /
    • 1996
  • The present study investigates experimentally the characteristics of liquid jet, which is, the spray flow in the normal direction of the air stream under the flow conditions of air velocity $110\sim125m/s$. The present study adopts with the flow visualization technique using a short duration light bulb and the image processing analyse with CCD camera. Two types of injector were used: one is a flat plate type, and the other is backward facing step type, which height are 5, 8, 10mm. Dispersion of liquid jet can be represented by gray level of CCD camera. In the upstream of liquid jet, the backward facing step shows better liquid jet penetration. However, in the downstream. mean droplet size for backward facing step injector is smaller than that for flat plate injector

  • PDF

New Parameterizations for Multi-Step Unconstrained Optimization

  • Moghrabi, I.A.;Kassar, A.N
    • Journal of the Korean Society for Industrial and Applied Mathematics
    • /
    • 제3권1호
    • /
    • pp.71-79
    • /
    • 1999
  • We consider multi-step quasi-Newton methods for unconstrained optimization. These methods were introduced by Ford and Moghrabi [1, 2], who showed how interpolating curves could be used to derive a generalization of the Secant Equation (the relation normally employed in the construction of quasi-Newton methods). One of the most successful of these multi-step methods makes use of the current approximation to the Hessian to determine the parameterization of the interpolating curve in the variable-space and, hence, the generalized updating formula. In this paper, we investigate new parameterization techniques to the approximate Hessian, in an attempt to determine a better Hessian approximation at each iteration and, thus, improve the numerical performance of such algorithms.

  • PDF

Symbolic Cluster Analysis for Distribution Valued Dissimilarity

  • Matsui, Yusuke;Minami, Hiroyuki;Misuta, Masahiro
    • Communications for Statistical Applications and Methods
    • /
    • 제21권3호
    • /
    • pp.225-234
    • /
    • 2014
  • We propose a novel hierarchical clustering for distribution valued dissimilarities. Analysis of large and complex data has attracted significant interest. Symbolic Data Analysis (SDA) was proposed by Diday in 1980's, which provides a new framework for statistical analysis. In SDA, we analyze an object with internal variation, including an interval, a histogram and a distribution, called a symbolic object. In the study, we focus on a cluster analysis for distribution valued dissimilarities, one of the symbolic objects. A hierarchical clustering has two steps in general: find out step and update step. In the find out step, we find the nearest pair of clusters. We extend it for distribution valued dissimilarities, introducing a measure on their order relations. In the update step, dissimilarities between clusters are redefined by mixture of distributions with a mixing ratio. We show an actual example of the proposed method and a simulation study.

A New Transition Criterion for Stratified and Nonstratified Flows in Pipes

  • Sung, Chang-Kyung;Chun, Moon-Hyun
    • 한국원자력학회:학술대회논문집
    • /
    • 한국원자력학회 1996년도 춘계학술발표회논문집(2)
    • /
    • pp.219-226
    • /
    • 1996
  • A two-step approach has been used to obtain a new transition criterion for the stratified and nonstratified flow in horizontal pipe: (1) In the first step, a more general expression than the existing models for the flow transition criterion has been derived from the analysis of singular points and neutral stability conditions, or the parallel lines conditions of the transient one-dimensional two- phase flow equations of two-fluid model. (2) In the second step, introducing simplifications and incorporating a parameter into the general expression obtained in the first step to satisfy a number of physical conditions a priori specified, a new simple flow transition criterion for horizontal pipes has been derived. Comparison between results predicted by the present theory with the experimental data and theories in the pipe flow conditions, show good agreement.

  • PDF

Correction of the Approximation Error in the Time-Stepping Finite Element Method

  • Kim, Byung-Taek;Yu, Byoung-Hun;Choit, Myoung-Hyun;Kim, Ho-Hyun
    • Journal of Electrical Engineering and Technology
    • /
    • 제4권2호
    • /
    • pp.229-233
    • /
    • 2009
  • This paper proposes a correction method for the error inherently created by time-step approximation in finite element analysis (FEA). For a simple RL and RLC linear circuit, the error in time-step analysis is analytically investigated, and a correction method is proposed for a non-linear system as well as a linear one. Then, for a practical inductor model, linear and non-linear time-step analyses are performed and the calculation results are corrected by the proposed methods. The accuracy of the corrected results is confirmed by comparing the electric input and output powers.

FACTOR/AIM을 이용한 통합자동 생산시스템의 성능분석을 위한 비교연구 (A Comparative Study of FMS Performance Evaluation Modeling Using FACTOR/AIM)

  • 황흥석
    • 산업공학
    • /
    • 제9권2호
    • /
    • pp.191-202
    • /
    • 1996
  • A variety of approaches on performance evaluation modeling have appeared in the technical literature for flexible manufacturing systems(FMS) which can be evaluated only through computer simulation. This study represents a comparative approach for FMS performance evaluation modeling based on reliability, availability and maintainability, and life cycle cost. The methodology proposed in this research includes the following three-step generative approaches. First, a static model to find the initial system configuration is considered under the assumption that the system availability is given as one (failure and maintenance are not considered), and in second step, a stochastic simulation is proposed to serve as a performance evaluation model for FMS with stochastic failure and repair time. In the last step, we developed a simulation modeling using a simulator, FACTOR/AIM to consider a variety of performance factors and dynamic behavior of FMS. Also the applicability and validity of the proposed approaches has been tested and compared through the results of a sample problem using computer programs and procedures developed in each step.

  • PDF

STEP 기반 CAD 데이터베이스의 액세스 성능 평가 실험 (An Evaluation of Access Performance of STEP-based CAD Database)

  • 김준환;한순홍
    • 산업공학
    • /
    • 제17권2호
    • /
    • pp.226-232
    • /
    • 2004
  • In shipbuilding area, data sharing is one of the crucial issues. Recently, for collaborative design, ship structural CAD systems adopt the database as its primary storage. Database is useful to deal with the large amount of design information among the heterogeneous design department and design stage. To make the database-based CAD system object-oriented database(OODB) and object-relational database(ORDB) can be used. It is important to select proper database because the CAD system performance mainly depends on access performance of database. In this research, using prototype CAD system from other research, access performance of OODB and ORDB form CAD system was evaluated. STEP application protocol was used as the database schema and experiment was made in query by property and query by region. The results give some idea of how to choose the database for CAD systems.