• 제목/요약/키워드: One room

검색결과 2,388건 처리시간 0.036초

다수의 출구를 가진 선박용 대형 저소음 룸유닛 개발 (Development of shipboard large-sized low-noise room unit with multiple outlets)

  • 김상렬;김현실;이성현;박근효
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2012년도 춘계학술대회 논문집
    • /
    • pp.600-605
    • /
    • 2012
  • In this paper, the acoustic performance of a shipboard large-sized room unit is studied. The room unit is a kind of rectangular absorptive chamber with a partition whose surface absorptive material with fabric skin is attached to. The room unit has one inlet and three outlet. At the inlet, a plane damper is installed to control the flow rate. The acoustic performance of a prototype room unit is measured using a HVAC mock-up. It is shown that its insertion loss is comparable with that of a commercially-used room unit but the developed room unit generates flow noise higher than the other one. The major source of flow noise is analyzed by NADS-R, the noise analysis program for room unit. Cone-shaped dampers are proposed to be used as the damper of a room unit to reduce flow noise. It is shown that the cone-shaped damper decrease flow noise remarkably.

  • PDF

다수의 출구를 가진 선박용 대형 저소음 룸유닛 개발 (Development of Shipboard Large-sized Low-noise Room Unit with Multiple Outlets)

  • 김상렬;김현실;이성현;박근효
    • 한국소음진동공학회논문집
    • /
    • 제22권5호
    • /
    • pp.468-473
    • /
    • 2012
  • In this paper, the acoustic performance of a shipboard large-sized room unit is studied. The room unit is a kind of rectangular absorptive chamber with a partition whose surface absorptive material with fabric skin is attached to. The room unit has one inlet and three outlets. At the inlet, a plane damper is installed to control the flow rate. The acoustic performance of a prototype room unit is measured using a HVAC mock-up. It is shown that its insertion loss is comparable with that of a commercially-used room unit but the developed room unit generates flow noise higher than the other one. The major source of flow noise is analyzed by NADS-R, the noise analysis program for room unit. Cone-shaped dampers are proposed to be used as the damper of a room unit to reduce flow noise. It is shown that the cone-shaped damper decrease flow noise remarkably.

대학주변 원룸형 다가구주택에 있어서 거주자 평가에 의한 소음실태분석 (The Analysis on the Present Condition of Noise of the Residents Subjective Responses in One-Room Type Multi-Family Housing around Campus)

  • 최윤정
    • 대한가정학회지
    • /
    • 제41권10호
    • /
    • pp.1-13
    • /
    • 2003
  • The purpose of this study is to make clear the present condition and the reason of noise in one-room ape multi-family housing around the campus by residents' subjective responses. The respondents are 104 residents living in one-room ape multi-family housing around the campus. The results are as follows. 1) The residents show relatively non-positive responses at evening and night on the present condition of noise in outdoor and indoor of building or indoor of house unit. 2) The types of outdoor noise of building are checked frequently are 'talking loudness' and 'traffic noise'. 'Walking and talking sounds in stairs and corridors' among the types of indoor noise of building shows highest percentage. They answer 'living equipment noise' and 'water hammer' as major types of indoor noise of house unit.

룸 튜닝에 의한 실내 공진의 최소화 (On the Minimization of Room Resonance by Room Tuning)

  • 강성훈
    • 한국음향학회지
    • /
    • 제31권8호
    • /
    • pp.507-513
    • /
    • 2012
  • 스피커를 실내에서 재생하면 공진에 의해서 저역에 피크와 딥이 생겨서 좋은 저음을 재생하기 어렵다. 이러한 공진을 줄이기 위해서 어느 특정 지점에서 전기적으로 이퀄라이징을 하지만, 이는 그 지점에서만 유효하다. 그리고 이퀄라이징으로 주파수 특성을 평탄하게 조정할 수 있지만, 특정 주파수에서 울림(ringing)은 제거되지 않는다. 다른 방법은 실내 공진이 여기되지 않은 지점에 스피커를 설치하는 것이다. 그러나 현실적으로 실내에서는 여러 가지 제약 때문에 원하는 지점에 스피커를 실제로 설치하기가 어렵다. 따라서 실내 공진에 의한 저주파수의 문제를 해결하기 위한 이상적인 방법은 베이스 트랩을 사용하는 것이다. 본 논문에서는 이퀄라이징에 의한 룸 튜닝과 스피커를 설치하는 위치의 최적화를 논의하고, 공진 모드에 의한 저주파수의 문제는 베이스 트랩을 실내에 설치하여 해결하는 것이 최상의 방법이라는 것을 제시하였다.

황색종 잎담배 공동건조장의 환경개선

  • 신승구;백기현;이승철
    • 한국연초학회지
    • /
    • 제20권2호
    • /
    • pp.160-165
    • /
    • 1998
  • The Joint curing barns for flue-cured tobacco is a favorite with the tobacco farmers in Korea. However, most of farmer utilizing the joint curing barns indicated many problems such as high temperature and noise in the working room and a dry of cured leaves in the storage room. A structure of Joint curing barns has been modified to meet the needs of tobacco farmers. Compared with the unimproved joint curing barns, the improved one showed that the noise of workshop decreased about 7.7~10.8db, the amount of $CO_2$ decreased 40~50ppm in a working room and 80~100ppm in a machine room. Ammonia gas decreased 0.29mg/㎥ and the temperature of a working room dropped about 2.1~3.5$^{\circ}C$. The amount of air flow in a working room increased 23.2% at a site being 2m away from the entrance and 30.8% at a center. The inner temperature of the improved storage room showed that maximum temperature dropped about 3$^{\circ}C$, minimum temperature was high about 2$^{\circ}C$. The highest relative humidity was low 6%, the lowest one increased high about 10% when compared with the unimproved joint curing barns.

  • PDF

대학가 원룸촌 외부공간의 생활안전 기능요소에 관한 연구 -충청북도 소재 'O' 대학교 원룸촌 사례를 중심으로- (A Study on the elements of Life Safety Environment in the exterior Space of the University neighborhood One-room village -Focused on the case of 'O' university neighborhood One-room village in Chungcheongbukdo-)

  • 김환식
    • 한국산학기술학회논문지
    • /
    • 제19권12호
    • /
    • pp.321-331
    • /
    • 2018
  • 본 연구는 거주자의 생활안전도를 연구하기 위한 기초 단계로서, 대학교 인근 원룸촌을 대상으로 거주자 의식조사 및 현장조사 등을 통해 대학가 원룸촌의 생활안전요소를 도출하고, 문제점 및 해결방향을 건축계획적 차원에서 다음과 같이 제시하였다. 첫째, 선행연구 결과 거주공간의 진입로 등 넓은 범위의 외부공간에 대한 생활안전 관련 연구나 실제 제도는 상대적으로 미흡하였다. 의식조사 결과, 거주공간의 생활안전 환경에 가장 심리적 영향을 미치는 요소는 보행로와 같은 외부공간의 환경이 거주지의 생활안전성에 가장 큰 영향을 미치는 것으로 나타났다. 둘째, 거주지 외부공간의 생활안전 기능요소는 건축 계획적 차원에서 크게 거주자 감시, 동선유도와 영역 구분, 외부의 공적 공간 활용, 쾌적한 환경 유지 등의 4개 유형으로 분류할 수 있으며, 이러한 요소는 건물 진입 공간뿐만 아니라 보행로나 기타 오픈스페이스 등 보다 넓은 범위의 공간에도 적용될 수 있다. 셋째, 대학가 원룸촌의 외부공간을 조사 분석한 결과, 보행로 같은 외부공간의 생활안전 환경이 거주인구와 원룸 건축물이 가장 많은 구역에서 매우 열악한 것으로 나타났다.

A study on DCGL determination and the classification of contaminated areas for preliminary decommission planning of KEPCO-NF nuclear fuel fabrication facility

  • Cho, Seo-Yeon;Kim, Yong-Soo;Park, Da-Won;Park, Chan-Jun
    • Nuclear Engineering and Technology
    • /
    • 제51권8호
    • /
    • pp.1951-1956
    • /
    • 2019
  • As a part of the preliminary decommissioning plan of KEPCO-NF fuel fabrication facility, DCGLs of three target radionuclides, 234U, 235U, and 238U, were derived using RESRAD-BUILD code and contaminated areas of the facility were classified based on contamination levels from the derived DCGLs. From code simulations, one-room modeling results showed that the grinding room in building #2 was the most restrictive (DCGLgross = 10493.01 Bq/㎡). The DCGLgross results in contaminated areas from one-room modeling were slightly more conservative than three-room modeling. Prior to the code simulation, field survey and measurements conducted by each survey unit. For a conservative approach, the most restrictive DCGLgross in each survey unit was taken as a reference to classify the contaminated areas of the facility. Accordingly, seven rooms and 37 rooms in the nuclear-fuel buildings were classified as Class 1 and Class 2, respectively. As expected, fuel material handling and processing rooms such as the grinding room, sintering room, compressing room, and powder collecting room were included in the Class 1 area.

반도체공장 Clean Room에 대한 화재요인 분석 및 성능위주 화재안전설계 (Fire Hazard Analysis and Performance Based Fire safety Design for the Clean Room in Semiconductor Factory)

  • 한수진;강경식
    • 대한안전경영과학회:학술대회논문집
    • /
    • 대한안전경영과학회 2006년도 추계공동학술대회
    • /
    • pp.325-336
    • /
    • 2006
  • This research analyzes clean room major fire prevention standard of clean Room (FM, IRI, and NFPA Code), the structure of Performance-Based Fire Safety Design (PBD) applied the korean fire industry situation. Performance-Based Fire Safety can operate effectively the performance of fire protection equipment & building design, so the fitness of fire safety system can be embodied by operating this. moreover, cost to be consume fire safety of real building can reduce and Performance-Based Fire Safety is considered to important technique in fire protection field. A fire in a clean room may cause a serious loss by spreading smoke particles. We will be investigated by using a computational fluid dynamics, for loss prevention by smoke spreading from one fire area to another for clean room and compared the Performance-Based Fire Safety Design with the prescriptive code design. The methodology of fire safety performance-based fire safety design and guarantee of many kinds design skill of fire system and developing design procedure will be very serious one in order to improve efficiency of domestic system. Therefore, This research will be contributing to secure safety of clean room and to set up the performance-based fire safety design in Korea by regulation for the performance-based fire safety design effectively.

  • PDF

반도체공장 Clean Room에 대한 화재요인 분석 및 성능위주 화재안전설계(1) (Fire Hazard Analysis and Performance Based Fire safety Design for the Clean Room in Semiconductor factory(1))

  • 한수진;강경식
    • 대한안전경영과학회지
    • /
    • 제8권5호
    • /
    • pp.211-229
    • /
    • 2006
  • This research analyzes clean room major fire prevention standard of clean Room(FM, IRI, and NFPA Code), the structure of Performance-Based Fire Safety Design(PBD) applied the korean fire industry situation. Performance-Based Fire Safety can operate effectively the performance of fire protection equipment & building design, so the fitness of fire safety system can be embodied by operating this. moreover, cost to be consume fire safety of real building can reduce and Performance-Based Fire Safety is considered to important technique in fire protection field. A fire in a clean room may cause a serious loss by spreading smoke particles. We will be investigated by using a computational fluid dynamics, for loss prevention by smoke spreading from one fire area to another for clean room and compared the Performance-Based Fire Safety Design with the prescriptive code design. The methodology of fire safety performance-based fire safety design and guarantee of many kinds design skill of fire system and developing design procedure will be very serious one in order to improve efficiency of domestic system. Therefore, This research will be contributing to secure safety of clean room and to set up the performance-based fire safety design in Korea by regulation for the performance-based fire safety design effectively.

거실수납가구의 디자인 특성 분석 (A Study on Design Charateristic of Living Room Storage Furniture)

  • 박혜숙;김수경
    • 한국실내디자인학회논문집
    • /
    • 제19권1호
    • /
    • pp.94-99
    • /
    • 2010
  • The purpose of this study is to develop living room storage furniture with multiple functions and for analyzing living room system furniture that can correspond with lifestyles in the living room. Literature survey was used by collecting data on interior design books and magazines. System furniture is very functional depending on the purpose and spaces, and can be modified effectively with the development of design based on the resident's demand. Living room furniture was mostly arranged by two types. One was lower and slimmer in order to use the space effectively, the other totally occupied one side of the living room wall. Furniture combined with multiple functions of lights and electronics can increase the satisfaction and convenience of users. And furniture maximizes storage space and is systemized so that mixture and arrangement are diversified. Flexible and active way furniture that accept various electronic fixtures and performances in the living room. Furniture forms, materials, and colors will be designed for the functions and atmosphere of living rooms. This results will contribute to develop furniture that has additional features such as lighting and electronic appliances hereafter.