• Title/Summary/Keyword: One Chicago

Search Result 114, Processing Time 0.021 seconds

Effects of SLA surface treated with NaOH on surface characteristics and response of osteoblast-like cell (염기처리한 SLA 표면이 표면 특성 및 골모유사세포의 반응에 미치는 영향)

  • Park, Jin-Chul;Kim, Joo-Hyeun;Kang, Eun-Sook;Ryu, Jae-Jun;Huh, Jung-Bo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.52 no.3
    • /
    • pp.211-221
    • /
    • 2014
  • Purpose: The purpose of this study was to evaluate the surface characteristics and response of osteoblast-like cell at SLA surface treated with NaOH. Materials and methods: Three kinds of specimens were fabricated for the experiment groups. Control group was a machined surface, SLA group was a conventionally SLA treated surface, and SLA/NaOH gorup was SLA surface treated with NaOH. To evaluate the surface characteristics, the surface elemental composition (XPS), surface roughness and surface contact angle were evaluated in each group. And the cytotoxicity, cell adhesion, cell proliferation and ATP activity of osteoblast-like cells (MG-63 cells) were compared in each group for evaluatation of the cell responses. Statistical comparisons between groups were carried out via one-way ANOVA using the SPSS software (SPSS Inc., Chicago, USA), and then performed multiple comparisons. The differences were considered statistically significant at P<.05. Results: SLA surface treated with NaOH (SLA / NaOH group) was changed to hydrophilic surface. All groups did not show the cytotoxicity to the MG-63. In cell adhesion studies, SLA / NaOH group showed the higher degree of adhesion than anothers (P<.05), Up to 7 days of incubation, the proliferation was showed the increasing tendency in all groups but SLA / NaOH group showed the highest cell proliferation between the three groups (P<.05). At 7 days of incubation, there was no difference in ALP activities between the three groups, but at 14 days, SLA / NaOH group showed significant increase in ALP activities (P<.05). Conclusion: In this study, SLA surface treated with NaOH promoted cell adhesion, proliferation and differentiation. It means that SLA/NaOH group is possible to promote osseointegration of implants.

A Study on Matched Errors between PET and CT Images in PET/CT Examination According to Breathing Protocols (PET/CT 검사에서 호흡법에 따른 PET과 CT 영상의 정합오차)

  • Kim, Sang Un;Kwak, Dong Woo;Park, Hyeon Soo;Bang, Seong Ae;Park, Yeong Jae;LEE, In Won
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.17 no.1
    • /
    • pp.7-10
    • /
    • 2013
  • Purpose : This study evaluated the effects of breathing protocols on matching results of PET and CT images using two breathing protocols such as free breathing and acquisition in holding the breathing after the normal expiration in acquiring CT images. Materials and Methods: Whole body FDG PET and CT images of 200 patients (mean age: 58 (range 20~84), 103 males and 97 females) using Discovery VCT (GE Healthcare, Milwaukee, USA). When taking CT images, subjects were asked to breathe freely (free breathing, n=100) or hold the breathing after the normal expiration (Hold, n=100). In the whole body image coronal section where PET and CT were matched, the matched error of the boundary between diaphragm and liver was measured in length. The matched errors were compared according to breathing protocol by age, sex and disease. The verification of statistical significance was made by SPSS 15.0 (SPSS Inc., Chicago, IL, USA) via one way ANOVA. Results: The matched error in all was 0.87 mm. According to breathing protocol, there was no significant difference in matched error as1.01 mm in free breathing and as 0.73 mm in hold breathing (p=.688). The matched error according to sex did not show significant difference as 1.08 mm of males, and 0.93 mm of females in free breathing (p=.517). In hold breathing, there was no significant difference as 0.79 mm of males and 0.66 mm of females (p=.738). There was no significant difference in matched error by age between free breathing and hold breathing (free breathing (p=.728), hold (p=.465). There was no significant difference in matched error by disease between free breathing and hold breathing (free breathing (p=.197), hold (p=.518) Conclusion: The difference in matched error between free breathing and hold breathing was less than 5 mm at 99%. There was no statistically significant difference in matched error by breathing protocol, age and disease. It was proved that there was no difference in matched error between PET and CT images according to breathing protocol during PET/CT scan.

  • PDF

Consideration on the Satisfaction of Patients and SUV Variation According to Whether or not to Listen to Music after 18F-FDG Injection (PET/CT 검사에서 18F-FDG 투여 후 음악 청취 여부에 따른 SUV변화와 환자의 만족도에 관한 고찰)

  • Park, Suyoung;Yun, Sunhee;Kim, Hwasan;Kim, Hyunki
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.17 no.2
    • /
    • pp.37-43
    • /
    • 2013
  • Purpose: PET/CT scan using the SUV (Standardized Uptake Value) of radiopharmaceutical uptake in organs and tissues as an objective indicator makes it possible to analyze physiological and chemical reactions of human organs. This study analyzes the change of the SUV uptake in accordance with the way how PET/CT patients take a rest after the injection of $^{18}F-FDG$ (Fluororo-deoxyglucose). And also subjective satisfaction is assessed listening to music while taking a rest. Materials and Methods: From April 2011 until February 2013, Among the Primary cancer patients who admitted to the Catholic Medical Center (Seoul & Bucheon St. Mary's Hospital) and scanned $^{18}F-FDG$ PET/CT and also received care through the tracking test (mean age $55.61{\pm}12.41$ years, 108 people, 48 men and 60 women) were selected. The patients were divided into two groups. The first group (A: basal study) is requested to take a rest in bed quietly after the injection. However the second one (B: follow up study) is requested to listen to the music while taking a rest. And then SUV analysis was performed respectively. At the end of the scan, ROI (Region Of Interest) were set from the center of the liver (right lobe) and 3 spots of the brain (frontal, temporal, and occipital lobes). And the SUV was calculated. To identify the correlation among those ROIs, paired t-test was performed using SPSS software (Version 12.0K for windows, P>0.05). Also, after the PET/CT scan the satisfaction study was conducted of all the patients. 1:1 questionnaire survey was performed, and that questionnaire was made using the Likert 5-point scale. By utilizing those questionnaires, the analysis about simple frequency, percentage, average, and standard deviation was performed. Results: The SUV change of the 4 designated ROIs in accordance with listening to music was not statistically significant. (Frontal lobe P-value=0.611, Occipital lobe P-value=0.499, Temporal lobe P-value=0.717, Liver P-value=0.334: P-value>0.05) And the satisfaction study indicated that group B was appear to be 0.42 points (5 basis points) higher than group A. It showed that patients are more satisfied in group B than group A. Conclusion: when performing PET/CT scan using $^{18}F-FDG$, listening to music after the injection of the radiopharmaceuticals does not affect the SUV but given the state of the psychological comfort that may increase the patient's satisfaction.

  • PDF

The Definition of Outer Space and the Air/Outer Space Boundary Question (우주의 법적 지위와 경계획정 문제)

  • Lee, Young-Jin
    • The Korean Journal of Air & Space Law and Policy
    • /
    • v.30 no.2
    • /
    • pp.427-468
    • /
    • 2015
  • To date, we have considered the theoretical views, the standpoint of states and the discourse within the international community such as the UN Committee on the Peaceful Uses of Outer Space(COPUOS) regarding the Air/Outer Space Boundary Question which is one of the first issues of UN COPUOS established in line with marking the starting point of Outer Space Area. As above mentioned, discussions in the United Nations and among scholars of within each state regarding the delimitation issue often saw a division between those in favor of a functional approach (the functionalists) and those seeking the delineation of a boundary (the spatialists). The spatialists emphasize that the boundary between air and outer space should be delimited because the status of outer space is a type of public domain from which sovereign jurisdiction is excluded, as stated in Article 2 of Outer Space Treaty. On the contrary art. I of Chicago Convention is evidence of the acknowledgement of sovereignty over airspace existing as an international customary law, has the binding force of which exists independently of the Convention. The functionalists, backed initially by the major space powers, which viewed any boundary demarcation as possibly restricting their access to space, whether for peaceful or non-military purposes, considered it insufficient or inadequate to delimit a boundary of outer space without obvious scientific and technological evidences. Last more than 50 years there were large development in the exploration and use of outer space. But a large number states including those taking the view of a functionalist have taken on a negative attitude. As the element of location is a decisive factor for the choice of the legal regime to be applied, a purely functional approach to the regulation of activities in the space above the Earth does not offer a solution. It seems therefore to welcome the arrival of clear evidence of a growing recognition of and national practices concerning a spatial approach to the problem is gaining support both by a large number of States as well as by publicists. The search for a solution to the problem of demarcating the two different legal regimes governing the space above Earth has undoubtedly been facilitated and a number of countries including Russia have already advocated the acceptance of the lowest perigee boundary of outer space at a height of 100km. As a matter of fact the lowest perigee where space objects are still able to continue in their orbiting around the earth has already been imposed as a natural criterion for the delimitation of outer space. This delimitation of outer space has also been evidenced by the constant practice of a large number of States and their tacit consent to space activities accomplished so far at this distance and beyond it. Of course there are still numerous opposing views on the delineation of a outer space boundary by space powers like U.S.A., England, France and so on. Therefore, first of all to solve the legal issues faced by the international community in outer space activities like delimitation problem, there needs a positive and peaceful will of international cooperation. From this viewpoint, President John F. Kennedy once described the rationale behind the outer space activities in his famous "Moon speech" given at Rice University in 1962. He called upon Americans and all mankind to strive for peaceful cooperation and coexistence in our future outer space activities. And Kennedy explained, "There is no strife, ${\ldots}$ nor any international conflict in outer space as yet. But its hazards are hostile to us all: Its conquest deserves the best of all mankind, and its opportunity for peaceful cooperation may never come again." This speech seems to even present us in the contemporary era with ample suggestions for further peaceful cooperation in outer space activities including the delimitation of outer space.