• 제목/요약/키워드: Ondol system

검색결과 142건 처리시간 0.022초

온돌난방에서의 자세에 따른 온열생리적 반응의 성차 (Effectsd of posture on physiological thermal responses with Ondol heating system)

  • 신정화;최정화
    • 한국의류학회지
    • /
    • 제22권8호
    • /
    • pp.1020-1031
    • /
    • 1998
  • This study was done to investigate thermal reponses and to obtain the basic information of thermal comfort by sex and posture under the Ondol heating system. Six healthy males and females were exposed to Ondol(Room Temp.: 25$\pm$1$^{\circ}C$, 50$\pm$10%R.H, Floor Temp.:30$\pm$1$^{\circ}C$) on the of posture such as sitting, lying aside and supine on the floor for 30 minutes after 30 minutes' control phase. During the experiment, rectal temperature, skin temperature of 10 areas, local sweating rate, clothing microclimate, subjective sensation were measured. Rectal temperature gradually decreased and mean skin temperature grad-ually increased both male and female in any posture. There was not significant difference between male and female in rectal temperature and mean skin temperature. There were significant difference among the postures in rectal temperature(p<0.001) and mean skin temperature(p<0.001). In lying aside and supine on the floor, appearances of change and changes in rectal temperature and mean skin temperature were large, changes of weight were small. In sitting on the floor, appearances of change and changes in rectal temperature and mean skin temperature were small, changes of weight were large. The trunk skin tem-perature was higher in female than in male, but the extremity skin temperature was higher in male than in female. In sitting on the floor, foot skin temperature(p<0.001) was higher than any other local skin temperature. In supine on the floor, back skin temperature(p<0.001) was higher than any other local skin temperature.

  • PDF

유한차분법(有限差分法)을 이용한 온수온돌(溫水溫突) 바닥구조체(構造體)의 비정상(非正常) 열전달(熱傳達) 해석(解析)과 실험(實驗) 연구(硏究) (An Experimental Study and Transient Simulations of the Radiant Heating Floor Panel by Using Finite Difference Methods)

  • 손장렬;정광섭;박병윤
    • 설비공학논문집
    • /
    • 제3권1호
    • /
    • pp.69-77
    • /
    • 1991
  • "Ondol" have been used in residential buildings for several thousands years in Korea. The traditional "Ondol" heating system of Korea has changed into the radiant heating system with piping embedded in floors or slabs. This study reports the results of transient experiments performed on a radiant heating system and enclosure. The paper presents some details of the thermal response of slab-heated buildings to varying patterns of heat input. Furthermore, I'll compare the results of experimentation with the ones of the numerical simulation by using the explicit and implicit forms of the finite difference methods (FDM). The study has contributed to testify the feasibility of numerical analysis, and the understanding of the transient behavior of radiant heating panels and enclosure exposed to this type of heating system.

  • PDF

온돌을 이용한 바닥복사냉방의 제습시스템 적용에 관한 연구 (A Study on the Application of the Dehumidification System for Radiant Floor Cooling Using Ondol)

  • 임재한;여명석;양인호;김광우
    • 설비공학논문집
    • /
    • 제14권7호
    • /
    • pp.607-616
    • /
    • 2002
  • This study has been conducted to evaluate the applicability of the control method in the dehumidification-integrated radiant floor cooling system in terms of stability of the room air temperature and the control variables through experiments. To do this, the relationship between the control variables in preventing floor surface condensation is first analyzed and the control method is predetermined through simulations. The results are as follows. First, it is necessary to determine the operation status of the dehumidification system according to the relationship between floor surface temperature and dew point temperature in the conditioned space. Second, outdoor reset with indoor temperature feedback control is better than on/off bang-bang control with respect to temperature stability in controlling the room air temperature and the possibility of energy savings. Finally, the humidity sensor can be located with the current thermostat in that there are small differences in absolute humidity in vertical distribution.

환기시스템을 갖춘 온돌 성능에 관한 연구 (A Study on the Performance of Ondol with a Ventilation System)

  • 전성택;조진표
    • 한국산학기술학회논문지
    • /
    • 제15권7호
    • /
    • pp.4047-4051
    • /
    • 2014
  • 현대의 공동 주택은 에너지 효율을 높이기 위해 고기밀, 고단열 방식으로 지어지고 있는데 이러할 경우 환기량 부족에 따른 각종 부작용이 발생을 한다. 본 연구에서는 우리나라의 겨울철 대표적인 난방원으로 사용되고 있는 온돌시스템을 기본으로 구성하고 환기방법에 따른 실내 열환경을 평가하여 환기 방식에 따른 에너지 절감 요인을 분석하였다. 실험장치는 일정한 외기 조건을 모사하기 위해 항온항습 챔버에 뜬바닥 온돌 시스템을 설치하고 온돌시스템의 외기온도/습도 조건은 3조건($10^{\circ}C$/50%Rh, $0^{\circ}C$/-, $-10^{\circ}C$,-)으로 설정 하였다. 공급되는 온수온도는 2 조건($60^{\circ}C$, $50^{\circ}C$) 설정하여 설정된 환기 방식에 따라 성능시험을 수행 하여 열 환경 및 에너지 절감 요인을 비교 분석 하였다. 실험결과 급기온도는 온수온도가 높을수록 급기풍량이 적을수록 높았으며 바닥 급/배기 > 전열교환 급/배기 > 강제 급/배기 순으로 나타났다. 본 연구를 통해 다양한 환기 방식의 적용 가능성에 대하여 검토 할 수 있었다.

공동주택에서 비난방세대가 미치는 열적 영향 (Analysis for Thermal Effect by an Unheated Housing Unit in Apartment)

  • 이은주;구준모;홍희기
    • 설비공학논문집
    • /
    • 제28권1호
    • /
    • pp.42-47
    • /
    • 2016
  • Adjacent housing units suffer inevitable thermal losses if an unheated unit exists in an apartment building. Thermal loss of the units adjoining the unheated apartment can be neglected because the contact area is small and insulators are located in the walls. When insulators are not included in the slab between the upper and lower units, 70% of the heat supplied by an Ondol system may be used in the original unit, but 30% is transferred to the unit on the lower floor. Another 30% can be obtained from the ceiling if the upper floor housing unit is heated. This strong thermal connection is a characteristic of Ondol heating in apartment buildings. When there is an unheated unit, the lower floor unit uses 42.3% more heating energy if there is no insulation and 19.5% if a 35 mm insulator is used as in the current guidelines. Therefore, much thicker insulation should be applied to weaken the thermal connection.

안동 "임청각(臨淸閣)"의 건축 이력과 원형 가구(架構) 추정 -사랑채와 안채를 중심으로- (Construction History of the Old House "IMCHEONGGAK" in Andong and Estimation of its Original Structure -Focused on the 'Inner chamber' and the 'Sarang section'-)

  • 이종서
    • 건축역사연구
    • /
    • 제25권2호
    • /
    • pp.31-44
    • /
    • 2016
  • Imcheong-gak[臨淸閣] was a familial residence constructed in the early half of the Joseon dynasty period. It was partially destroyed by a fire during the 1590s war[壬辰倭亂] with the Japanese, and another fire that was caused between 1631 and 1634. The inner chamber[An-chae] and the Sarang section[Sarang-chae] today is the result of a partial reconstruction that took place back in 1626 and again around 1634. The residence also went through some changes because the new Ondol[溫突] heating system had to be applied to the structure. Based upon sections that remain in their original forms, we can presume that the Imcheong-gak residence originally had an inner chamber which was composed of the following elements: A main structure which was built upon a foundation featuring a Matbae[맞배] roof, two "Ik'rang[翼廊, flank]" sections on the East and West sides of the inner chamber, and a "Haeng'rang[行廊, passage]" structure on the opposite side of the main structure. Unlike the main structure, other portions of the inner chamber were all built directly upon the ground, and showed multiple stories, with Matbae roofs of their own. We can also assume that the Sarang section in the south would have been a pre-Ondol[溫突] bedroom, with a Board platform[板房] and a Gomi-ceiling[Gomi-banza] fashion.

잠열저장재를 이용한 온돌판넬의 축열 및 방열특성에 관한 연구 (The characteristics of heat storage and emission of PCM in Ondol system)

  • 조수;유제인;정헌생
    • 태양에너지
    • /
    • 제10권2호
    • /
    • pp.38-43
    • /
    • 1990
  • 본 연구는 염화칼슘6수화물($CaCl_2{\cdot}6H_2O$)을 온돌판넬에 적용하여 가열시간에 따른 잠열재판넬의 축열 및 방열특성을 조사하기 위하여 같은 크기의 실험동($1.8m^L{\times}1.8m^W{\times}1.8m^H$)을 지었다. 잠열재판넬에 적용할 알루미늄 용기는 $1.6cm^T{\times}9cm^W{\times}80cm^H$ 크기로 제작하여 염화칼슘6수화물(1.25kg)을 충진시켰다. 잠열재인 염화칼슘6수화물을 넣은 온돌판넬은 실내공기온의 변화폭을 줄이고, 잠열재의 상변화과정에서 방열되는 시간은 축열에 필요한 가열시간의 $2{\sim}4$배 정도였다.

  • PDF

應答係數法에 의한 溫水 溫室 暖房 시스템의 Simulation (Simulation of the hot water ONDOL heating system by response factor method)

  • 조상준;민만기;최영돈
    • 대한기계학회논문집
    • /
    • 제11권3호
    • /
    • pp.409-424
    • /
    • 1987
  • 본 연구에서는 유한차분법보다는 정확도가 약간 떨어지지만 공기조화 분야의 계산에 적합하고 계산시간이 적게 소요되는 응답계수법을 사용하여 온수온돌방계의 비 정상 열전달을 해석하였다.

온돌의 연탄개스유량에 관한 연구(1) (함습저온열기류의 굴뚝통풍력) (Study on the Flow of Briquette Gas in the Ondol Heating System (Chimney Draft of Low Temperature Moist Air))

  • 민만기
    • 대한설비공학회지:설비저널
    • /
    • 제4권2호
    • /
    • pp.119-128
    • /
    • 1975
  • Natural draft and flow which low temperature moist gas produces in the chimney of an Ondol heating system were numerically analysed. Among several factors involved inlet gas temperature has the strongest influence on the chimney performance and then next specific humidity of the gas. Thermal conductivity of the chimney wall, however, has little influence on the performance of such a low temperature chimney. Under given flow conditions there exists an optimum chimney height which gives a maximum flow rate for a given chimney diameter. This optimum value of chimney height inereases with increase in chimney diameter, inlet gas temperature and specific humidity.

  • PDF