• Title/Summary/Keyword: Ondol system

Search Result 142, Processing Time 0.023 seconds

An Experimental Study on the Thermal Efficiency of the Ondol House Beating System (온돌의 열효율에 관한 실험적 연구)

  • Bae soonhoon;Kang Shin-Hyoung
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.4 no.3
    • /
    • pp.183-190
    • /
    • 1975
  • Most Korean houses are heated by the Ondol heating system. There has been, however, no reasonable design procedure availabe yet for the system. The conventional design should be improved to have auniform floor surface. temperature distribution and to have a high thermal efficiency. Thermal efficiencies of the ondol were defined and the method of experimentation was studied. An experiment, using a life-size model which was well insulated, was performed to observe the variation in thermal efficiency as the length of fuel burning time was varied.

  • PDF

Characteristics of Ondol Heating Load for the Determination of Heat Pump Power (열펌프 시스템의 규모 결정을 위한 온돌난방부하 특성)

  • 노정근;백은기;송현갑
    • Journal of Biosystems Engineering
    • /
    • v.28 no.3
    • /
    • pp.217-224
    • /
    • 2003
  • To find out heating load and to determine the power of heat pump compressor for the Ondol room heating the COP of heat pump, the variation of Ondol room air temperature, the variation of ambient temperature and power consumption of heat pump are analyzed. The results from this study were summarized as follows: 1. The COP of the heat pump in close loop decreased as the ambient air temperature. The COP was 2.26 when the temperature difference of condenser was $20\pm3^{\circ}C$. 2. The Ondol surface temperature was $25\pm3^{\circ}C$ when the hot water of $40^{\circ}C$ was supplied from hot water storage tank to the Ondol and the temperature difference between the Ondol surface and the room air temperature was $7~8^{\circ}C$. 3. The ratio of thermal conduction heating load to total heating load in Ondol heating space was found to be 83% and ratio of ventilation heating load was 17%. Therefore, the thermal conduction heating load was confirmod to be a major heating load in Ondol heating space. 4. In case of the ambient temperature of $3.2^{\circ}C$, the efficiency of heat exchange of Ondol heating system was 85%. 5. The heating load per Ondol heating surface area and volume of Ondol room space were theoretically analyzed. In case of the room temperature of $20^{\circ}C$ and the ambient temperature of $-3.2~3.8^{\circ}C$, the heating load per Ondol surface area was 115.8~167.6kJ/h ㆍ㎥ and per Ondol mom space volume was 50.2~72.7kJ/h ㆍ㎥. 6. The compressor power of heat pump fur the Ondol room heating could be determined with the heating load analyzed in this study In case of the Ondol room air temperature of 17~2$0^{\circ}C$ and the ambient temperature of -5~3.8$^{\circ}C$, the compressor power of heat pump per Ondol surface area was analyzed to be $2.3\times10^{-2}psm^2$, and per volume of Ondol room space $1.0\times10^{-2}1.4\times10^{-2}ps/m^2$ps.

Theoretical Analysis on Heat Transfer Characteristics and Heat Flux Performance in Ondol Systems of Dried Type (건식온돌시스템의 전열특성 및 방열성능에 관한 이론적 분석)

  • Jang, Yong-Sung;Yu, Ki-Hyung;Cho, Dong-Woo
    • Proceedings of the SAREK Conference
    • /
    • 2007.11a
    • /
    • pp.176-181
    • /
    • 2007
  • This study aims to evaluate theoretically heat transfer characteristics and heat flux performance in ondol system of dried type is composed of panel of ceramics to improve of thermal conductivity and fin to expand heat. To this end, we analyzed effect of design factors(temperature of hot water, set temperature of room and thermal conductivity of finishing materials) in ondol system of dried type by heat transfer analysis. The main results of this study are summarized as follows; The deviation of heat flux and temperature was reduced by heat expansion from fin decreasing heat loss generated in air layer. The temperature and heat flux in upper finishing materials surface linearly increased according to temperature increment of hot water, but the temperature distribution in upper surface was assessed uneven. The greater heat resistance value of upper finishing materials, the deviation of maximum temperature and minimum temperature was decreased. Also, we suggested a basic design data about ondol system of dried type through an analysis of simulation results on heat transfer characteristics and heat flux performance.

  • PDF

Experiment and Property Study of Ondol Panel Based on Phase Change Material (PCM을 이용한 온돌패널의 실험 및 특성연구)

  • Yoon, Doo-Han;Choi, Bong-Su;Hong, Hi-Ki
    • Proceedings of the SAREK Conference
    • /
    • 2006.06a
    • /
    • pp.122-125
    • /
    • 2006
  • This paper deals with the Ondol, Korean under-floor heating system using latent heat storage materials. It has been recognized that the heating system using the latent heat storage materials are economically efficient and comfortable. For the comparison and analysis to the data of the existing experiment, a repetitive experiment makes sure the ability of Ondol panel.

  • PDF

An experimental study on the heat transfer characteristics of a Ondol-heated space by varying pipe embedding depths and hot water supply conditions (보일러 운전조건 및 마감층 두께 변화에 따른 온돌난방공간의 열특성에 관한 실험연구)

  • 박병윤
    • Proceeding of Spring/Autumn Annual Conference of KHA
    • /
    • 1991.09a
    • /
    • pp.41-47
    • /
    • 1991
  • This study reports the results of the transient temperature response of a floor heating panel according to variation of the hot water supply temperature and the pipe embedding depth. Also, this experiment compares the temperature responses of floor heating panels under the continuous and intermittent heating system. Furtthermore, this study presents some details of the thermal response of Ondol-heated buildings to varying loads and patterns of heat input. The analysis of the thermal performance fo Ondol heating system have been presented.

  • PDF

A Study on the Korean Ondol-System Application in Apartment Houses (공동주택의 한국형 온돌시스템 적용에 관한 연구)

  • Ahn, Min-Hee;Choi, Chang-Ho;Yu, Ki-Hyung;Cho, Dong-Woo
    • Proceedings of the SAREK Conference
    • /
    • 2006.06a
    • /
    • pp.860-865
    • /
    • 2006
  • The traditional Korean Ondol System that is a radiant floor heating system was made as warm floor and cool indoor temperature. Nowaday, Ondol is developed as the hydronic floor heating system. But unbalance of floor temperature and indoor temperature is occurred bocause strengthen thermal insulation and airtightness in building changes thermal performance. To solve these problems, we examine actual indoor environment of heating system methods in existing apartments and present the new method of floor heating system. The existing heating system made definite indoor temperatures but floor temperatures that is $22^{\circ}C-26^{\circ}C$ was maintained. To solve these problems, we adopted the differential heating system which made warm area and cool area. A differential heating system was made different pitches of heating pipe in single zone and ratio of warm area to cool area is 1 to 2. As a result of experiments, warm area temperature is $40.7^{\circ}C$, cool area temperature is $36.1^{\circ}C$. A difference of temperature between both area is 4K. A distribution of indoor vertical temperature is similar to both warm area and cool area.

  • PDF

A Historical Study of Ondol (온돌에 대한 역사적 고찰)

  • 윤정숙
    • Journal of the Korean Home Economics Association
    • /
    • v.17 no.2
    • /
    • pp.49-56
    • /
    • 1979
  • In Korean housing designs reflect uniqueness as a result of the influence of regional and atmospheric factors. In this regard, the early use of the hot floor (ondol) system is of special significance. This system is still in use today, not only for house-heating purposes in the homes of commoners, but also for cooking in the kitchen. The present study represents an investigation of the ondol structure since its earliest known usage. Methodology involves a documentary examination of the system. In point of time, this begins with the system's earliest usage and proceeds chronnologically down to the end of the Yi Dynasty. Research indicates that something very much like the ondol system appeared in the early tribal society of Mahan and its usage continued in the state of Koguryo (during the Three Kingdoms Period) in the homes of the poor. This unique system which had its origin in cold northern areas was utilized on a much broader basis during the Koryo Dynasty. Coming down to the Yi Dynasty it found acceptance and application in all parts of the peninsula. Variations in major component parts of the structure, such as the fuel hole, the flue, the draft , and the chimney, normally reflect regional dissimilarities. It is perhaps most significant that here-in contrast to other devices we have a system that serves concurrently for both heating and cooking purposes.

  • PDF

Numerical Analysis of Heat Flow and Heat Transfer in Flue Channel of Two-Dimensional Ondol Panel Heating System (2차원(次元) 온돌 상난방(床煖房)시스템의 연도내 열유동(熱流動) 및 열전달(熱傳達) 수치해석(數値解析))

  • Kim, Y.D.;Min, M.K.;Lee, S.H.;Kim, W.K.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.6 no.4
    • /
    • pp.337-343
    • /
    • 1994
  • Numerical analysis was applied to a simplified two-dimensional Ondol heating model which consists of heating space on the top of it along with radiant and convective heating floor panel, flue channel in the midway and rectangular underground soil region at the bottom. These three components constitute a system thermally coupled at the top and bottom interfaces of the flue channel. Investigated in the present paper are effects with variations of the Reynolds numbers of 100, 200, and 300, Grashof numbers of $0.1{\times}10^6$ and $0.3{\times}10^6$ and aspect ratios of 15 and 20 on the heat transfer and fluid flow characteristics of two-dimensional Ondol heating model by computer simulation.

  • PDF

Thermoregulatory Responses in the Elderly and the Young under the Ondol System (온돌난방에서 노인과 청년의 피부온 반응 비교)

  • 정유정;최정화
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.22 no.1
    • /
    • pp.149-158
    • /
    • 1998
  • The purpose of this study was to investigate the effect of age on the human thermoregulatory responses and to obtain the basic information of the Korean thermophysiological characteristics under the traditional Korean floor heating system-Ondol. The participants consisted of 10 elderly women, 4 elderly men(over 65 years), 10 young women and 5 young men(in twenties). They were exposed to temperature-controlled Ondol room(20$\pm$1$^{\circ}C$, 50$\pm$5%R.H., floor surface temperature: 30$\pm$1$^{\circ}C$) for 60 minutes and wore the same experimental clothing. The postures were performed sitting and supine on the floor. In each pose, rectal temperature, skin.temperature of 10 areas, mean skin temperature, clothing microclimate, body fat were measured. The results were as follows; 1. The rectal temperature gradually decreased and mean skin temperature gradually increased in young and old groups in both supine and sitting pose on heated Ondol floor for 60 minutes. 2. Rectal temperature was different in each pose. The rectal temperature decreased 0.1$^{\circ}C$ in both groups under the condition of sitting and decreased 0.2'c in elderly group under the condition of supine. In supine pose, elderly group was more declined than young group. Mean skin temperature increased 0.5$^{\circ}C$ in both poses, both groups.

  • PDF

A Study of the Ondol (Gudul, Floor Heating System) and Kitchen Space in the Traditional Houses on Jeju Island, Korea

  • Kim, Bong-Ae;Lee, Jeong-Lim
    • International Journal of Human Ecology
    • /
    • v.4 no.1
    • /
    • pp.15-23
    • /
    • 2003
  • Jeju-do is a volcanic island located off the shore of the Korean peninsula facing the Pacific Ocean. The traditional housing styles of the Jeju Province, therefore, reflect the impact of these natural backgrounds and reveal different housing styles that are distinctive from those of mainland Korea. The purpose of this research is to analyze the peculiarities of the Ondol (floor heating system) and the kitchen space of traditional housing of Jeju Island in terms of lifestyles. This study shall employ two research methods: a literature review and field survey methods. The literature review shall focus on the observations of characteristics noted in previous studies of Jeju's private houses. The field survey shall employ field survey and interview methods originating from the ethnography of the culturological-anthropologist approach. (1) The Jeju-do Ondol system is a “Weibang-eudul” system which means one Gudul per fire hole. (2) The definition of terms for Gulmook show variations depending on the various regions on Jeiu-do. (3) Major facilities in Jeongji include Gulmook, Sotduck, and Busup. Gulmook is a heating facility and Sotduck refers to a cooking facility; Busup refers to a combination of heating, cooking, and illuminating facilities.