• 제목/요약/키워드: Oncology patient

검색결과 1,810건 처리시간 0.028초

암환자가족의 가족기능에 대한 조사연구 (A Study on the Family Functioning in the Family with the Cancer Patient)

  • 한숙정
    • 종양간호연구
    • /
    • 제3권2호
    • /
    • pp.155-163
    • /
    • 2003
  • This study was designed to assess the level of family function between cancer patient's families and normal families, and to seek better quality family-Mcentered nursing care. The subjects for this study were 95 ca patient's families who were selected from th university hospitals and 95 normal families who selected from 1 university hospital. The instrument used for this study was McMaster Family Assessment Device (FAD) developed by Epstein, Baldwin and Bishop (1983). The scale consisted of 53 items covering 7 areas: 'problem solving', 'communication', 'roles', 'affective responsiveness', 'affective involvement', 'behavior control', and 'general functioning'. As for data analyses, descriptive statistics, ${\chi}^2-test$, t-test, ANOVA were adopted using SAS program. The result of this study was as follows: There there was no significant difference between cancer patient's family function and normal family function. Also there was no significant difference on cancer patient's family function with regard to family characteristics, disease's characteristics, and clinical stage of cancer.

  • PDF

영남대학교병원의 환자안전을 위한 정도관리의 기초자료 분석 (Basic Data Analysis of the Quality Control for Patient Safety in Department of Radiation Oncologyat Yeungnam University Hospital)

  • 오세안;김성규;예지원;강민규;이준하;이레나
    • 한국의학물리학회지:의학물리
    • /
    • 제26권2호
    • /
    • pp.112-117
    • /
    • 2015
  • 미국의학물리학회(AAPM) TG-100 위원회에서 제시하고 있는 가이드 라인에 준하여 환자 안전에 대한 정도관리를 수립하기 위하여 영남대학교병원 방사선종양학과에서 환자를 치료하는 중에 발생한 오류들을 중심으로 오류 유형을 분석하여, 환자중심의 방사선치료를 시행할 때 환자 안전을 위한 정도관리의 가이드 라인을 정립하고자 한다. 방사선종양학과에서 방사선 치료를 하는데 있어서 일으킬 수 있는 오류들을 분석하여 오류를 일으키는 빈도와 오류가 일어날 때 환자 에게 미치는 심각성과 오류가 일어났을 때 감지하지 못하고 지나치는 확률을 점수로 평가하고자 한다. 오류를 일으킬 수 있는 곳으로는 CT 모의치료실, 치료계획실, 치료실로 나누어 조사하였다. CT 모의치료실에서는 고정기구 사용의 오류가 위험중요지수의 값이 60으로 가장 높았고, 모의치료 정보입력의 오류가 6으로 가장 낮게 나타났다. 치료계획실에서는 선량계산 모델 선택의 오류가 위험중요지수의 값이 168로 가장 높았고, 환자의 치료 시작일 오류가 36으로 가장 낮게 나타났다. 치료실에서는 테이블 Bar 오류가 위험중요지수의 값이 252으로 가장 높았고, 체중변화 오류가 190을 나타내었으며, 배게 오류가 24로 가장 낮게 나타났다.

Clinical performance of FractionLab in patient-specific quality assurance for intensity-modulated radiotherapy : a retrospective study

  • Oh, Se An;Kim, Sung Yeop;Park, Jaehyeon;Park, Jae Won;Yea, Ji Woon
    • Journal of Yeungnam Medical Science
    • /
    • 제39권2호
    • /
    • pp.108-115
    • /
    • 2022
  • Background: This study was aimed at comparing and analyzing the results of FractionLab (Varian/Mobius Medical System) with those of portal dosimetry that uses an electronic portal imaging device. Portal dosimetry is extensively used for patient-specific quality assurance (QA) in intensity-modulated radiotherapy (IMRT). Methods: The study includes 29 patients who underwent IMRT on a Novalis-Tx linear accelerator (Varian Medical System and Brain-LAB) between June 2019 and March 2021. We analyzed the multileaf collimator DynaLog files generated after portal dosimetry to evaluate the same condition using FractionLab. The results of the recently launched FractionLab at various gamma indices (0.1%/0.1 mm-1%/1 mm) are analyzed and compared with those of portal dosimetry (3%/3 mm). Results: The average gamma passing rates of portal dosimetry (3%/3 mm) and FractionLab are 98.1% (95.5%-100%) and 97.5% (92.3%-99.7%) at 0.6%/0.6 mm, respectively. The results of portal dosimetry (3%/3 mm) are statistically comparable with the QA results of FractionLab (0.6%/0.6 mm-0.9%/0.9 mm). Conclusion: This paper presents the clinical performance of FractionLab by the comparison of the QA results of FractionLab using portal dosimetry with various gamma indexes when performing patient-specific QA in IMRT treatment. Further, the appropriate gamma index when performing patient-specific QA with FractionLab is provided.

A Comparison between Portal Dosimetry and Mobius3D Results for Patient-Specific Quality Assurance in Radiotherapy

  • Kim, Sung Yeop;Park, Jaehyeon;Park, Jae Won;Yea, Ji Woon;Oh, Se An
    • 한국의학물리학회지:의학물리
    • /
    • 제32권4호
    • /
    • pp.107-115
    • /
    • 2021
  • Purpose: The purpose of this study was to compare the clinical quality assurance results of portal dosimetry using an electronic portal imaging device, a method that is extensively used for patient-specific quality assurance, and the newly released Mobius3D for intensity-modulated radiotherapy (IMRT) and volumetric modulated arc therapy (VMAT). Methods: This retrospective study includes data from 122 patients who underwent IMRT and VMAT on the Novalis Tx and VitalBeam linear accelerators between April and June 2020. We used a paired t-test to compare portal dosimetry using an electronic portal imaging device and the average gamma passing rates of MobiusFX using log files regenerated after patient treatment. Results: The average gamma passing rates of portal dosimetry (3%/3 mm) and MobiusFX (5%/3 mm) were 99.43%±1.02% and 99.32%±1.87% in VitalBeam and 97.53%±3.34% and 96.45%±13.94% in Novalis Tx, respectively. Comparison of the gamma passing rate results of portal dosimetry (3%/3 mm) and MobiusFX (5%/3 mm as per the manufacturer's manual) does not show any statistically significant difference. Conclusions: Log file-based patient-specific quality assurance, including independent dose calculation, can be appropriately used in clinical practice as a second-check dosimetry, and it is considered comparable with primary quality assurance such as portal dosimetry.

일 상급종합병원 암환자 고객경험관리 (Customer Experience Management for Cancer Patients in a Tertiary Hospital)

  • 원영화;김지혜;정은희;곽은아;양윤정;신순자;김연희;김정혜
    • 임상간호연구
    • /
    • 제23권3호
    • /
    • pp.321-331
    • /
    • 2017
  • Purpose: The purpose of this study was to investigate the effect of customer experience management on nursing service satisfaction of cancer patients and their intent to revisit the hospital and also to identify empathy ability of oncology nurses. Methods: Participants were 376 cancer patients and 190 oncology nurses from a tertiary hospital in Korea. Cancer patients' satisfaction with nursing care and intent to continue using the hospital were measured and empathy of oncology nurses was measured using Empathy Construct Rating Scale. Data were analyzed using descriptive statistics, ${\chi}^2$ test, t-test, one-way ANOVA and stepwise multiple regression analysis. Results: Patient satisfaction with nursing care and intent to continue using the hospital were higher in patients who received the customer experience management program than those who did not. Oncology nurses' ability to empathize was high. Clinical career, participate in customer experience management and education level together explained 20% of variance in empathy ability of oncology nurses. Conclusion: Findings from this study confirm that customer experience management affects patient satisfaction with nursing service and intent to continue using the hospital. Further research is necessary to reaffirm the empathy ability of the oncology nurses and to identify the related various factors.

Carcinoma of the Tongue: A Case-control Study on Etiologic Factors and Dental Trauma

  • Bektas-Kayhan, Kivanc;Karagoz, Gizem;Kesimli, Mustafa Caner;Karadeniz, Ahmet Nafiz;Meral, Rasim;Altun, Musa;Unur, Meral
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제15권5호
    • /
    • pp.2225-2229
    • /
    • 2014
  • Background: Carcinoma of the tongue is the most common intra-oral malignancy in Western countries. Incidence and mortality rates have increased in recent years, and survival has not improved. This study aimed to determine etiologic factors for tongue cancer with age-sex matched case-control data. Materials and Methods: 47 patients with carcinoma of the tongue referred to our oral medicine clinic between years 2005-2006 were analyzed and compared with control group data. The medical records, including family history of cancer, dental trauma, and history of abuse of alcohol and tobacco products was recorded for all subjects. Chi square comparison tests and linear regression analysis were performed using the SPSS program for statistics. Results: Patient and randomly selected control groups each consisted of 30 male and 17 female subjects with mean ages 53.2 (${\pm}12.6$) and 52.6 (${\pm}11.5$) years respectively. Smoking and alcohol abuse proportions were significantly higher in the patient group (p=0.0001, p<0.0001 respectively). Chronic mechanical trauma was observed in 44.7% of the patients and 17.0% of the control group (p=0.004). Similarly, family history of cancer of any type (for the first degree relatives) was found to be more common in the patient group (p=0.009). On regression analysis, alcohol abuse, family history of cancer, smoking, chronic mechanical traumas appeared as significant etiologic factors (p=0.0001). Conclusions: We believe that field cancerization may become evident in oral and oropharyngeal mucosa with multiple steps of molecular changes starting from the first sign of dysplasia with chronic exposure to etiological factors. Chronic trauma cases need particular attention to search for very early signs of cancer.

도체탕(導滯湯) 위주의 한방치료로 호전된 활동성 궤양성 대장염 환자 치험 1례 (A Case Report of a Patient with Active Ulcerative Colitis Treated with Do-Che Decoction-based Korean Medicine)

  • 윤성우
    • 대한암한의학회지
    • /
    • 제17권2호
    • /
    • pp.17-22
    • /
    • 2012
  • Background : Sulfasalazine for treating ulcerative colitis has a clinical limitation due to its adverse effects. This case is about a patient with ulcerative colitis who could not tolerate sulfasalazine and was improved by Do-che decoction-based Korean medicine. Method and Results : Purulent and bloody diarrhea more than 20 times a day, mild fever, chilling and tenesmus were main symptoms of this patient who was diagnosed as ulcerative colitis 10 years ago. Do-che decoction-based Korean medicine which was recommended for purulent and bloody diarrhea in Dong-Ui-Bo-Gam, the classic literature of Traditional Korean Medicine was given to the patient for more than 1 month. After treatment, the frequency of purulent and bloody diarrhea, tenesmus and fever was decreased remarkably, and C-reactive protein, erythrocyte sedimentation rate, white blood cell count and maximum temperature also dropped to the normal range. Conclusion : Do-che decoction-based Korean medicine has a potential effect and may be a alternative therapeutic option in patients with ulcerative colitis who cannot tolerate sulfasalazine due to its adverse effects.

외부조사 방사선치료 기간 중 총담도 스텐트의 위치 변화가 컸던 사례 (A Bile Duct Cancer Patient Whose Stent Shifted Significantly Over the Course of External Beam Radiotherapy)

  • 윤형근
    • Radiation Oncology Journal
    • /
    • 제29권2호
    • /
    • pp.121-126
    • /
    • 2011
  • 담도암 환자의 방사선치료 기간 중, 총담도에 삽입된 스텐트가 환자 복부의 우측부터 좌측까지 매우 넓은 범위로 움직인 경우를 발견하였다. 환자는 80세 노령의 여자로 흉추가 심한 척추 후만증을 보였고 흉추와 요추 몇 부위들에 압박골절이 있어서 키가 작았고 복부장기들이 아래로 내려와 있었다. 환자는 쇠약하고 야윈 상태였는데 방사선치료 기간 중 매주 컴퓨터단층촬영을 시행하여 비교한 결과 몸의 좌우방향으로 4 cm 이상의 스텐트의 위치 이동을 보였다. 따라서 흉추 후만증이 있으며서 몸이 매우 야윈 담도암 환자의 경우 방사선치료 범위 설정 시에 치료 기간 중 담도나 스텐트가 크게 움직일 가능성을 고려해야 할 것이다.

암환자교육이 암환자의 심리적 디스트레스와 자가간호지식 및 자가간호행위에 미치는 효과: 메타분석 (The Effect of Patient Education Interventions on Distress, Self-Care Knowledge and Self-Care Behavior of Oncology Patients: A Meta-Analysis)

  • 오복자;최형지
    • 종양간호연구
    • /
    • 제12권4호
    • /
    • pp.257-266
    • /
    • 2012
  • Purpose: The purpose of this study was to evaluate the effectiveness of patient education interventions on distress, self-care knowledge and self-care behavior in cancer patients. Methods: A total of 1,102 studies were retrieved from 6 electronic databases in Korea. From these studies, 18 studies met the inclusion criteria with a total of 850 participants. Two authors independently assessed the methodological quality by Cochrane's Risk of Bias and Methodological Items for Non Randomized Studies. The data were analyzed by the RevMan 5.1 program of Cochrane library. Results: Overall effect size of education interventions on anxiety was -2.12 (95% CI:-3.90, -0.34) (p<.001). The effects on self-care knowledge and self care behavior were -1.08 (95% CI:-1.73, -0.43) (p=.001), and -1.41 (95% CI:-2.13, -0.68) (p<.001), respectively. Publication bias was detected as evaluated by funnel plot, but the fail-safe number was moderate. Conclusion: This study suggests that patient education interventions can relieve anxiety and self-care. Further randomized controlled trials studies are needed to evaluate the effects of patient education intervention on depression.

Impressive effect of cisplatin monotherapy on a patient with heavily pretreated triple-negative breast cancer with poor performance

  • Baek, Dong Won;Park, Ji-Young;Lee, Soo Jung;Chae, Yee Soo
    • Journal of Yeungnam Medical Science
    • /
    • 제37권3호
    • /
    • pp.230-235
    • /
    • 2020
  • Systemic therapy for metastatic triple-negative breast cancer (TNBC) still remains challenging because there are no targeted agents or endocrine therapies currently available. The present case report documents the successful use of cisplatin monotherapy to manage a heavily pretreated TNBC patient showing poor response to therapy. The patient was a 51-year-old woman who had already undergone several lines of systemic chemotherapy for widespread TNBC. Although the mutation analysis performed on DNA isolated from blood cells and progressed lesion samples confirmed the tumor to be germline BRCA wild-type, cisplatin monotherapy was administered based on the increasing evidence of safety and efficacy of platinum for breast cancer. After three cycles of cisplatin treatment, the patient's metastatic lesions dramatically improved without any major toxicity, and she completed 17 cycles with good response. This case study indicates that patients with heavily pretreated TNBC can potentially achieve a good response to cisplatin monotherapy.