• Title/Summary/Keyword: Once through

Search Result 1,817, Processing Time 0.046 seconds

Implementation of a Dry Process Fuel Cycle Model into the DYMOND Code

  • Park Joo Hwan;Jeong Chang Joon;Choi Hangbok
    • Nuclear Engineering and Technology
    • /
    • v.36 no.2
    • /
    • pp.175-183
    • /
    • 2004
  • For the analysis of a dry process fuel cycle, new modules were implemented into the fuel cycle analysis code DYMOND, which was developed by the Argonne National Laboratory. The modifications were made to the energy demand prediction model, a Canada deuterium uranium (CANDU) reactor, direct use of spent pressurized water reactor (PWR) fuel in CANDU reactors (DUPIC) fuel cycle model, the fuel cycle calculation module, and the input/output modules. The performance of the modified DYMOND code was assessed for the postulated once-through fuel cycle models including both the PWR and CANDU reactor. This paper presents modifications of the DYMOND code and the results of sample calculations for the PWR once-though and DUPIC fuel cycles.

Development of a computer code for thermal-hydraulic design and analysis of helically coiled tube once-through steam generator

  • Zhang, Yaoli;Wang, Duo;Lin, Jianshu;Hao, Junwei
    • Nuclear Engineering and Technology
    • /
    • v.49 no.7
    • /
    • pp.1388-1395
    • /
    • 2017
  • The Helically coiled tube Once-Through Steam Generator (H-OTSG) is a key piece of equipment for compact small reactors. The present study developed and verified a thermal-hydraulic design and performance analysis computer code for a countercurrent H-OTSG installed in a small pressurized water reactor. The H-OTSG is represented by one characteristic tube in the model. The secondary side of the H-OTSG is divided into single-phase liquid region, nucleate boiling region, postdryout region, and single-phase vapor region. Different heat transfer correlations and pressure drop correlations are reviewed and applied. To benchmark the developed physical models and the computer code, H-OTSGs developed in Marine Reactor X and System-integrated Modular Advanced ReacTor are simulated by the code, and the results are compared with the design data. The overall characteristics of heat transfer area, temperature distributions, and pressure drops calculated by the code showed general agreement with the published data. The thermal-hydraulic characteristics of a typical countercurrent H-OTSG are analyzed. It is demonstrated that the code can be utilized for design and performance analysis of an H-OTSG.

A Study on Dynamic Matrix Control using Spray and Damper to Once-through Boiler Steam Temperature (스프레이와 댐퍼를 이용한 관류 보일러 스팀 온도의 (2X2) 동역학 행렬 제어에 관한 연구)

  • Kim, Woo-Hun;Moon, Un-Chul
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.1
    • /
    • pp.91-97
    • /
    • 2010
  • In this paper, we present simulation results of Dynamic Matrix Control (DMC) to a Once-through boiler steam temperature. In order to control the steam temperatures, we choose spray and damper as two input variables. Then, the step response model is generated for the two major output variables by step test. After that, on-line optimization is performed using $(2\times2)$ step response model. Proposed controller is applied to the APESS (Doosan company's boiler model simulator) and the simulation results show satisfactory performance of proposed control.

Study on the Structure Optimization and the Operation Scheme Design of a Double-Tube Once-Through Steam Generator

  • Wei, Xinyu;Wu, Shifa;Wang, Pengfei;Zhao, Fuyu
    • Nuclear Engineering and Technology
    • /
    • v.48 no.4
    • /
    • pp.1022-1035
    • /
    • 2016
  • A double-tube once-through steam generator (DOTSG) consisting of an outer straight tube and an inner helical tube is studied in this work. First, the structure of the DOTSG is optimized by considering two different objective functions. The tube length and the total pressure drop are considered as the first and second objective functions, respectively. Because the DOTSG is divided into the subcooled, boiling, and superheated sections according to the different secondary fluid states, the pitches in the three sections are defined as the optimization variables. A multi-objective optimization model is established and solved by particle swarm optimization. The optimization pitch is small in the subcooled region and superheated region, and large in the boiling region. Considering the availability of the optimum structure at power levels below 100% full power, we propose a new operating scheme that can fix the boundaries between the three heat-transfer sections. The operation scheme is proposed on the basis of data for full power, and the operation parameters are calculated at low power level. The primary inlet and outlet temperatures, as well as flow rate and secondary outlet temperature are changed according to the operation procedure.

Effect of once-a-day milk feeding on behavior and growth performance of pre-weaning calves

  • Syed Husnain Mushtaq;Danish Hussain;Hifz-ul-Rahman;Muhammad Naveed-ul-Haque;Nisar Ahmad;Ahmad Azeem Sardar;Ghazanfar Ali Chishti
    • Animal Bioscience
    • /
    • v.37 no.2
    • /
    • pp.253-260
    • /
    • 2024
  • Objective: The objectives of the present study were to evaluate the effects of once-a-day milk feeding on growth performance and routine behavior of preweaning dairy calves. Methods: At 22nd day of age, twenty-four Holstein calves were randomly assigned to one of two treatment groups (n = 12/treatment) based on milk feeding frequency (MF): i) 3 L of milk feeding two times a day; ii) 6 L of milk feeding once a day. The milk feeding amount was reduced to half for all calves between 56 and 60 days of age and weaning was done at 60 days of age. To determine the increase in weight and structural measurements, each calf was weighed and measured at 3 weeks of age and then at weaning. The daily behavioral activity of each calf was assessed from the 22nd day of age till weaning (60th day of age) through Nederlandsche Apparatenfabriek (NEDAP) software providing real-time data through a logger fitted on the calf's foot. Results: There was no interaction (p≥0.17) between MF and sex of the calves for routine behavioral parameters, body weight and structural measurements. Similarly, there was no effect of MF on routine behavioral parameters, body weight and structural measurements. However, the sex of the calves affected body weight gain in calves. Male calves had 27% greater total body weight and average daily gain than female calves. There was no effect of the sex of the calves on behavioral measurements. Collectively, in the current study, no negative effects of a once-a-day milk feeding regimen were found on routine behavioral and growth parameters of preweaning calves in group housing. Conclusion: Once-a-day milk feeding can be safely adopted in preweaning calves from 22nd day of age.

Recovery Efficiency of Cumulus Oocyte Complexes (COCs) according to Collection Frequency for Ovum Pick-up (OPU) Method in Hanwoo Cow

  • Kang, Sung-Sik;Kim, Ui-Hyung;Lee, Seok-Dong;Lee, Myung-Suk;Han, Man-Hye;Cho, Sang-Rae
    • Journal of Animal Reproduction and Biotechnology
    • /
    • v.34 no.4
    • /
    • pp.300-304
    • /
    • 2019
  • This study was conducted to examine the oocyte recovery efficiency through having an OPU session once and twice a week. Also, the oocyte recovery efficiency was examined by using OPU after two and three months of rest period. Six cows were used for oocytes collection and were randomly divided into two groups. In experiment 1, OPU sessions were conducted once and twice a week to collect oocytes. The collected oocytes between once and twice OPU groups were classified into four groups (grade 1, 2, 3 and 4) according to the quality of cumulus cells and ooplasm. Based on the result, the percentage of collected oocytes per aspirated follicle number was similar between once and twice OPU session groups (65.5 ± 1.9 and 68.7 ± 1.4 vs.). However, the percentage of grade 1 oocytes from the twice OPU session group was significantly high compared with that of the once a week OPU session group (25.3 ± 0.9 and 32.5 ± 1.2% vs. once and twice session group, respectively, p < 0.05). In experiment 2, the group with three months of rest period tended to have a high percentage of collected oocyte compared with the group with two months of rest period (64.6 and 70.9% vs. 2 and 3 months rest group, respectively, p = 0.62). The percentage of grade 4 in the group with three months of rest period was significantly low compared with the group with two months of rest period group (27.3 and 36.5% vs. two and three months rest group, respectively, p = 0.05). In conclusion, twice a week OPU session is suitable for collection of high quality oocytes by using OPU, and three months of rest period is needed for the recovery of oocyte quality of a donor cow.