• 제목/요약/키워드: On-ramp

검색결과 584건 처리시간 0.029초

첨단교통체계(ITS)에 의한 도시고속도록의 Ramp Metering 시스템 구축에 관한 연구 (The Ramp Metering System Construction of Urban Freeway by the Intelligent Transportation System (ITS) Technology)

  • 김태곤
    • 한국항만학회지
    • /
    • 제13권2호
    • /
    • pp.333-350
    • /
    • 1999
  • Today freeway is thought to be a very important transportation facility carrying tremendous traffic flow as the main corridor within the area of between the areas. However freeway is experiencing severe congestion and accidents by increased entrance ramp flow especially at peak time period. Ramp meters on the freeway entrance ramps that supply traffic to the freeway in a measured or appropriately regulated amount are needed for alleviating freeway congestion. Because ramp meters can be operated to discharge traffic at a measured or regulated rate thus maintaining more uniform speed on the mainline section maximizing the throughput to the freeway within the capacity of a downstream bottleneck and reducing the congestion related accidents. Thus the objectives in this study were to analyze the traffic characteristics on the freeway I-94 with ramp metering system before/after ITS technology in Detroit (Michigan) area compare shifts of the traffic characteristics on the freeway I-94 before/after ITS technology and finally suggest a better ramp metering strategy for the freeway system The following results were obtained: i)Flow occupancies and speeds on the mainline merge section of freeway were shown to be a big difference depending on the peak periods areas and directions based on the distribution of traffic flow characteristics on the freeway. ii)Reduced speed was shown to be more than 5 mph and ramp flow was also shown to be more than 240 vph at peak periods if there was the ramp metering system constructed on the freeway. iii)Ramp metering system was shown to be optimally operated on the freeway if ramp flow could be maximized within the range of over 900 vph and reduced occupancy could be also maximized by no more than 2 percent at peak periods. iv)The average flows on the freeway after the ITS technology were shown to be a decrease of over 20% depending on the peak periods areas and directions when compared with those flow on the freeway before the ITS technology. over 20% depending on the peak periods areas and directions when compared with those speeds on the freeway before the ITS technology. vi)The average metering rates on the freeway after the ITS technology were shown to be an increase of over 10% depending on the peak periods areas and directions when compared with those metering rates on the freeway before the ITS technology.

  • PDF

The Effects of Ramp Gradients and Pushing-Pulling Techniques on Lumbar Spinal Load in Healthy Workers

  • Pinupong, Chalearmpong;Jalayondeja, Wattana;Mekhora, Keerin;Bhuanantanondh, Petcharatana;Jalayondeja, Chutima
    • Safety and Health at Work
    • /
    • 제11권3호
    • /
    • pp.307-313
    • /
    • 2020
  • Background: Many tasks in industrial and health care setting are involved with pushing and pulling tasks up or down on a ramp. An efficient method of moving cart which reduces the risk of low back pain should be concerned. This study aimed to investigate the effects of handling types (HTs) and slope on lumbar spinal load during moving a cart on a ramp. We conducted a 2 × 2 × 4 factorial design with three main factors: 2 HTs, 2 handling directions of moving a cart and 4 degrees of ramp slope. Methods: Thirty healthy male workers performed 14 tasks consist of moving a cart up and down on the ramp of 0°, 10°, 15°, and 20° degrees with pushing and pulling methods. Joint angles from a 3D motion capture system combined with subject height, body weight, and hand forces were used to calculate the spinal load by the 3DSSPP program. Results: Our results showed significant effect of HT, handling directions and slope on compression and shear force of the lumbar spine (p < 0.001). When the ramp gradient increased, the L4/5 compression forces increased in both pushing and pulling (p < 0.001) Shear forces increased in pulling and decreased in pushing in all tasks. At high slopes, pulling generated more compression and shear forces than that of pushing (p < 0.01). Conclusion: Using the appropriate technique of moving a cart on the ramp can reduce the risk of high spinal load, and the pushing is therefore recommended for moving a cart up/down on ramp gradients.

초소형 HDD의 언로딩 과정에서 램프 형상에 대한 실험 연구 (Experimental Study on Various Ramp Profiles during Unloading Process)

  • 이용현;박경수;박노철;양현석;박영필
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2005년도 추계학술대회논문집
    • /
    • pp.314-317
    • /
    • 2005
  • There are many benefits such as increased areal density, reduced power consumption, applied smaller size and improved shock resistance in Load/Unload(L/UL) mechanism. It has been the key technology of developing small form factor hard disk drive used in portable digital devices. The main objectives of L/UL are no slider-disk contact and faster L/UL process. For realizing those, we must consider many design parameters in L/UL systems. In this paper, we focus on the effects of ramp profile. We can investigate dynamic characteristics of suspension tap and slider on ramp during unloading process experimentally. In special, we examine the effects of vortical velocities, ramp slopes and disk vibrations. As the result of these experiments, we propose design criteria of advanced ramp profile for good unloading performance.

  • PDF

1D AND 3D ANALYSES OF THE ZY2 SCIP BWR RAMP TESTS WITH THE FUEL CODES METEOR AND ALCYONE

  • Sercombe, J.;Agard, M.;Struzik, C.;Michel, B.;Thouvenin, G.;Poussard, C.;Kallstrom, K.R.
    • Nuclear Engineering and Technology
    • /
    • 제41권2호
    • /
    • pp.187-198
    • /
    • 2009
  • In this paper, three power ramp tests performed on high burn-up Re-crystallized Zircaloy2 - UO2 BWR fuel rods (56 to 63 MWd/kgU) within the SCIP project are simulated with METEOR and ALCYONE 3D. Two of the ramp tests are of staircase type up to Linear Heat Rates of 420 and 520 W/cm and with long holding periods. Failure of the 420 W/cm fuel rod was observed after 40 minutes. The third ramp test consisted of a more standard ramp test with a constant power rate of 80 W/cm/min up to 410 W/cm with a short holding time. The tests were first simulated with the METEOR 1D fuel rod code, which gave accurate results in terms of profilometry and fission gas releases. The behaviour of a fuel pellet fragment and of the cladding piece on top of it was then investigated with ALCYONE 3D. The size and the main characteristics of the ridges after base irradiation and power ramp testing were recovered. Finally, the failure criteria validated for PWR conditions and fuel rods with low-to-medium burn-ups were used to analyze the failure probability of the KKL rodlets during ramp testing.

경사로 오르기와 내리기 동안 압력중심 이동경로와 족저압 비교 (Comparison of Pathway of COP and Plantar Foot Pressures while Ascending and Descending a Slope)

  • 한진태
    • The Journal of Korean Physical Therapy
    • /
    • 제22권5호
    • /
    • pp.77-82
    • /
    • 2010
  • Purpose: The purpose of this study was to compare the pathway of COP and plantar foot pressure and to determine the correlation between plantar regions during the ascending and descending of a ramp. Methods: Fifteen healthy adults who had no musculoskeletal problems participated in our study. They were asked to walk on a level surface and on an ascending and descending ramp in their bare feet. Pathway of COP and plantar foot pressures were recorded using the Matscan system (Tekscan, Boston, USA). For pressure measurements, the plantar foot surface was divided into seven regions: two toe regions, three forefoot regions, a midfoot region, and a heel region. To determine whether there was a statistically significant difference between pathway of COP and plantar foot pressures during walking, we used repeated measuremes ANOVA. Results: In comparison to results for a level walking, pathway of COP while ascending a ramp had a tendency to be shifted medially in the forefoot and became longer till the big toe. Pathway of COP while descending a ramp also was shifted medially, but ended in the forefoot. Plantar foot pressure of the second and third metatarsal head and the fourth and fifth metatarsal heads was significantly decreased while descending the ramp. Conclusion: These results indicated that plantar foot pressure is changed while ascending and descending a ramp and demonstrated that ramp walking can affect the structure and function of the foot. Therefore, gait environment is associated with significant changes in foot characteristics, which contribute to altered plantar loading patterns during gait.

AC PDP에서 2차원 수치해석을 이용한 Ramp Reset 구동파형에 따른 방전 특성 분석 (The Discharge Characteristic Analysis of a Ramp Reset Waveform Using a 2-Dimensional Numerical Simulation in AC PDP)

  • 박석재;최훈영;서정현;이석현
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제53권12호
    • /
    • pp.606-615
    • /
    • 2004
  • The discharge characteristics of a ramp reset waveform in the alternating current plasma display panel(ac PDP) were studied using a 2-dimensional numerical simulation. We analyzed the wall charge variation during the reset discharge, address discharge and sustain discharge adopting a ramp reset waveform. Then we investigated the principal parameters for a successful discharge. In this paper, we suggest a new parameter, printing particles' density and its effects on the stability of the ramp discharge. The maximum current flows of the three electrodes during the ramp reset period were decreased with the increase in the priming particles's density which was explained with the wall charge characteristics and the current flow characteristics obtained by a 2-D simulation.

Kinematic Analysis of Head and Trunk Movements of Young Adults while Climbing Stairs or a Ramp

  • Han, Jin-Tae
    • The Journal of Korean Physical Therapy
    • /
    • 제22권6호
    • /
    • pp.21-28
    • /
    • 2010
  • Purpose: The purpose of this study was to investigate the kinematic adaptation of head and trunk to ascend stairs and a ramp. Subjects were healthy young adults. Three-dimensional kinematic patterns of head and trunk movements were examined during stair climbing and steeper ramp climbing. Methods: Fourteen young subjects with no history of chronic or acute musculoskeletal, cardiovascular or respiratory disorders took part in this experiment. Kinematic data were collected using a 6 camera Vicon system (Oxford Metrix, Oxford, England). Repeated measures ANOVA analyses were used to investigate the effect of gait mode on kinematics of the head and trunk. Results: The angle of the trunk while ascending stairs or a ramp was modified in three human planes (p<0.05). The angle of head and neck during the ascending of stairs or a ramp was not changed in the sagittal plane but was changed in the frontal and transverse planes (p<0.05). Conclusion: This study describes and discusses some basic kinematic mechanisms underlying the pattern of head and trunk changes during stair and ramp climbing and showed that postural adaptation of the head and trunk is necessary to maintain balance.

Velocity Measurement around Ramp Injector in Supersonic Flow

  • Koike, Shunsuke;Suzuki, Kentaro;Hirota, Mitsutomo;Takita, Kenichi;Masuya, Goro;Matsumoto, Masashi
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2004년도 제22회 춘계학술대회논문집
    • /
    • pp.117-124
    • /
    • 2004
  • The mixing enhancement is one of the most important problems for the development of scramjet engines. The influence of the streamwise vortices produced by a ramp in a unheated supersonic flow on the mixing of twin jets injected from its base was experimentally investigated. Nominal Mach number of the main airstream and of the twin jets at the nozzle exits were 2.35 and 2.0, respectively. Three dimensional velocity distributions near the ramp with and without injection were measured by Particle Image Velocimetry (PIV). A pair of counter rotating streamwise vortices could be seen behind the injector without injection. On the other hand, two pairs of streamwise vortices could be seen with injection. The outer one had the same direction as the vortex pair produced by the ramp, but they were stronger than those produced by the ramp. The inner ones had the opposite directions to the outer ones. It is considered that these vortices enhance the mixing near the injector.

  • PDF

램프 형상에 대한 램프 상의 로드/언로드 동특성 해석 (Load/Unload Dynamics of Slider on Ramp for Various Ramp Shape)

  • 이용현;박경수;박노철;양현석;박영필
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2005년도 춘계학술대회논문집
    • /
    • pp.467-472
    • /
    • 2005
  • Load/Unload(L/UL) technology includes the benefits, that is, increased areal density, reduced power consumption and improved shock resistance contrary to contact start stop(CSS). It has been widely used in portable hard disk drive and will become the key technology for developing the small form factor hard disk drive. The main objectives of L/UL are no slider disk contact or no media damage. For realizing those, we must consider many design parameters in L/UL systems. In this paper, we focus on the effect of the ramp profile. We can find out the lateral velocities in L/UL process through experiments and simulations for force of voice coil motor and friction force on ramp. And then, we will gain the optimal design of ramp slope to maintain the minimum clearance of suspension dimple and slider with FE model. In special, after finding the point at which air bearing breaks and designing the ramp, we will identify the results for improving unload performance.

  • PDF

점증 재하를 고려한 선행재하 공법 적용 연약지반의 현장 계측을 통한 침하량 예측 방법의 개발 (Prediction Method of Settlement Based on Field Monitoring Data for Soft Ground Under Preloading Improvement with Ramp Loading)

  • 우상인;윤찬영;백승경;정충기
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2008년도 춘계 학술발표회 초청강연 및 논문집
    • /
    • pp.452-461
    • /
    • 2008
  • Previous settlement prediction method based on settlement monitoring such as hyperbolic, monden method were developed under instantaneous loading condition and have restriction to be applied to soft ground under ramp loading condition. In this study, settlement prediction method under ramp loading was developed. New settlement prediction method under ramp loading considers influence factors of consolidation settlement and increase accuracy of settlement prediction using field monitoring data after ramp loading. Large consolidation tests for ideally controlled one dimensional consolidation under ramp loading condition were performed and the settlement behavior was predicted based on the monitoring data. As a result, new prediction method is expected to have great applicability and practicability for the prediction of settlement behavior.

  • PDF