• Title/Summary/Keyword: On-power Inspection

Search Result 544, Processing Time 0.032 seconds

Trends in Low-Power On-Device Vision SW Framework Technology (저전력 온디바이스 비전 SW 프레임워크 기술 동향)

  • Lee, M.S.;Bae, S.Y.;Kim, J.S.;Seok, J.S.
    • Electronics and Telecommunications Trends
    • /
    • v.36 no.2
    • /
    • pp.56-64
    • /
    • 2021
  • Many computer vision algorithms are computationally expensive and require a lot of computing resources. Recently, owing to machine learning technology and high-performance embedded systems, vision processing applications, such as object detection, face recognition, and visual inspection, are widely used. However, on-devices need to use their resources to handle powerful vision works with low power consumption in heterogeneous environments. Consequently, global manufacturers are trying to lock many developers into their ecosystem, providing integrated low-power chips and dedicated vision libraries. Khronos Group-an international standard organization-has released the OpenVX standard for high-performance/low-power vision processing in heterogeneous on-device systems. This paper describes vision libraries for the embedded systems and presents the OpenVX standard along with related trends for on-device vision system.

A research for improvement methods in the aspect of safety engineering through risk analysis of facilities for multiple use - Focused on escalator and passenger conveyors - (다중이용시설물 위험분석을 통한 안전공학적 개선 방안에 관한 연구 (에스컬레이터 및 수평보행기를 중심으로))

  • Kwon, Sun-Geol;Kim, Jin-Soo;Kim, Chang-Eun
    • Journal of the Korea Safety Management & Science
    • /
    • v.15 no.1
    • /
    • pp.31-40
    • /
    • 2013
  • For the matter of elevator, one of the multi-use facilities for unspecified public, the JIS has re-established and reformed to apply to the environment in South Korea for the past 20 years. In the aspect of safety assurance, it was inevitable to suggest improved measures. The government, Ministry of Public Administration and Security has secured the safety by enhancing the safety management functions in the elevator inspection standards and expanding its safety device measures. Further, the international inspection standard has been introduced, which is about unifying inspection standard system into the international standard code. In March 14th 2012, the international standard (EN) has been amended and fully announced. Escalator and passenger conveyor among lift devices have several common danger factor that cause safety accident. First, the accident caused by decreased braking power of brake. Second, the accident caused by the rate difference between handrail and tread-board. Third, the accident caused by defects of contraflow preventing device or carelessness inspection. Fourth, the accident caused by wet tread-board or wet floor of platform which makes passenger slip and fall. As the improvements to prevent and reduce these negligent accidents, the inspection list to check and methods should be subdivided and applied for each accident likelihood cause for safety management enhancement and safety assurance of existing escalator and passenger conveyors. The escalators and passenger conveyors without safety devices in existence should be obliged to modify the part of the system or install additional safety device. With making these measures obligations, it requires to improve the system to be suitable for the international inspection standard and to have measures to prevent safety accidents. It also needs to arrange improvements for skid accident of tread-board by the external environment factors such as snow and rain.

Defect Monitoring of a Wind Turbine Blade Surface by using Surface Wave Damping (표면파 기반의 풍력발전기 블레이드 표면상태 실시간 모니터링에 관한 연구)

  • Kim, Kyung-Hwan;Yang, Young-Jin;Kim, Hyun-Bum;Yang, Hyung-Chan;Lim, Jong-Hwan;Choi, Kyung-Hyun
    • Clean Technology
    • /
    • v.23 no.1
    • /
    • pp.90-94
    • /
    • 2017
  • These days much efforts are being dedicated to wind power as a potential source of renewable energy. To maintain effective and uniform generation of energy, defect preservation of turbine blade is essential because it directly takes effects on the efficiency of power generation. For the effective maintenance, early measurements of blade defects are very important. However, current technologies such as ultrasonic waves and thermal imaging inspection methods are not suitable because of long inspection time and non-real time inspection. To supplement the problems, the study introduced a method for real time defect monitoring of a blade surface based on surface wave technology. We examined the effect of various parameters such as micro-cracks and peelings on the propagation of surface wave.

The Development of the Inspection Model about Cognitive Ability according to Visual Artistic Giftedness Identification of the Elementary School Children (초등학교 아동의 미술영재성 판별에 따른 인지능력검사모형 구안)

  • Park, Myeong-Ok
    • Journal of Gifted/Talented Education
    • /
    • v.20 no.1
    • /
    • pp.1-30
    • /
    • 2010
  • The purpose of this study was to develop the inspection model of cognitive ability to identify visual artistic giftedness of the elementary school children with considering the relation between visual artistic giftedness and cognitive ability based on literature and preceding research. The research method applied literature research and quantitative research. Through literature review on the relation between art education and cognitive thinking and visual artistic of giftedness, it was suggested to prescribe the validity of cognitive ability as an element for identification of visual artistic giftedness identification, and then prescribed the elements of cognitive ability, and developed the inspection model of cognitive ability by measuring specific variables. Based on the results of literature research through the quantitative research, verified significance of developed inspection instrument on cognitive ability, validity and reliability of the inspection model of cognitive ability according to visual artistic giftedness identification of the elementary school children. As a result of reviewing related literature and preceding research, it could be referred that visual thinking ability, spatial perception power and critical thinking ability coincided with a characteristic of an art field can show excellent ability in various art activities and be valid criteria of visual artistic giftedness as cognitive ability of the visual artistic gifted with potential possibilities. In conclusion, as the elements of cognitive ability for the visual artistic giftedness identification of the elementary school children, visual thinking ability, spatial perception power and critical thinking ability were verified to be valid in terms of logical and experimental. Therefore, the result of the research will be able to provide a new approach in education program development of visual artistic giftedness of the elementary school children and a various developmental possibility in identification of visual artistic giftedness.

DEVELOPMENT OF A STEAM GENERATOR TUBE INSPECTION ROBOT WITH A SUPPORTING LEG

  • Shin, Ho-Cheol;Jeong, Kyung-Min;Jung, Seung-Ho;Kim, Seung-Ho
    • Nuclear Engineering and Technology
    • /
    • v.41 no.1
    • /
    • pp.125-134
    • /
    • 2009
  • This paper presents details on a tube inspection robotic system and a positioning method of the robot for a steam generator (SG) in nuclear power plants (NPPs). The robotic system is separated into three parts for easy handling, which reduces the radiation exposure during installation. The system has a supporting leg to increase the rigidity of the robot base. Since there are several thousands of tubes to be inspected inside a SG, it is very important to position the tool of the robot at the right tubes even if the robot base is positioned inaccurately during the installation. In order to obtain absolute accuracy of a position, the robot kinematics was mathematically modeled with the modified DH(Denavit-Hartenberg) model and calibrated on site using tube holes as calibration points. To tune the PID gains of a commercial motor driver systematically, the time delay control (TDC) based gain tuning method was adopted. To verify the performance of the robotic system, experiments on a Framatomes 51B Model type SG mockup were undertaken.

Network Camera for CMOS Camera Module Inspection (CMOS 카메라 모듈 검사를 위한 네트워크 카메라)

  • 신은철;최병욱
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2004.10a
    • /
    • pp.809-813
    • /
    • 2004
  • In this paper, we developed a network camera for CMOS camera module inspection. The design, implementation details including embedded linux porting and CPLD logics, and performance of network camera are described. The network camera consists of SoC(S3C4530A), CPLD and CMOS image sensor. In order to image data of CMOS image sensor we designed capture logics on CPLD by using VHDL program. Embedded Linux such as uClinux is performed on the network camera to utilize development environment and TCP/IP protocol specification. The application is based on socket communication between GUI on PC and Embedded Linux based network camera. When JPEG compression is applied, the transmission speed was improved enough for this system to be used for an alternative of expensive CCTV or remote monitoring system in a power plant and uninhabited places.

  • PDF

A Study on Insulation Property of White Powder Found on High Voltage Motor Stator Winding (백화현상이 나타난 고압전동기 고정자권선의 절연특성 연구)

  • Kong, Tae-Sik;Kim, Hee-Dong;Lee, Sang-Kil;Kim, Kyeong-Yeol;Ju, Young-Ho
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.8
    • /
    • pp.1627-1631
    • /
    • 2011
  • During a routine inspection of a large pump motor at power plant, white powder was found on the surface of the stator end windings. Visual inspection and high voltage insulation diagnosis was performed to determine whether this motor is available. The purpose of this paper is to understand the insulation properties of white powder found on high voltage stator and to know prevention of insulation weakness.

On-line Detection of Cracks in Eggshell (계란 크랙의 온라인 검출)

  • 최완규;조한근;백진하;장영창;연광석;조성찬
    • Journal of Biosystems Engineering
    • /
    • v.24 no.3
    • /
    • pp.253-258
    • /
    • 1999
  • This study was conducted to develop an automatic egg inspection system for detecting creaked eggs based on acoustic impulse response. This system includes a sound generator, a sound sensor with signal conditioner, and a computer. The sound generator that hit the sharp of the dull edges of an egg was constructed with a ceramic ball pendulum attached to a rotary type solenoid. The signal conditioner included a pre-amplifier and a digital signal processing (DSP) board. The parameters for distinguishing cracked and normal eggs were the area, the geometric centroid and the resonance frequency of power spectrum of the acoustic signal generated. An algorithm for on-line detection of the continuous transferring eggs was developed. The performance tests resulted with 91% success rate to separate cracked and normal eggs at the rate of 1 second per an egg.

  • PDF

Automatic Ultrasonic Inspection on Heater Sleeves and J-Groove Welds of Pressurizer (가압기 전열기 슬리브 및 J-Groove 용접부의 자동 초음파검사)

  • Ryu, Sung Woo;Chang, Hee Jun;Kim, Sun Je;Lee, Sang Duck;Sung, Jong Hwan
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.6 no.2
    • /
    • pp.20-27
    • /
    • 2010
  • In order to prevent the corrosion of component contacted primary water designed alloy 600 material in the nuclear power plant. But the primary water stress corrosion cracking(PWSCC) of alloy 600 and weld area occurs continuously due to the residual stress. The leakage accident resulted from PWSCC in the drain nozzle of the steam generator of domestic power plants. Heater sleeves of the pressurizer are welded with alloy 600 weld material and therefore exposed to the primary water environment. PWSCC occurred in heater sleeve material and weld area of many foreign power plants. The current issue of domestic nuclear power plants are consequently concentrated to PWSCC of similar material. In order to improve the detection and the sizing of the PWSCC in the welding sleeve of the pressurizer, the automatic UT system and multi-directions probe sets have been developed. The experimental studies have been performed using the mock-up block containing artificial reflectors(ID connected EDM notch) and semi-artificial cracks made from thermal fatigue. The automatic UT System is applied in the detection and the length sizing of the ID/OD on the tube and the J-groove weld area of the artificial reflectors and results of the detection and the sizing are compared respectively. Also, the developed automatic UT system is successfully accomplished to inspect the heater sleeve and the J-groove weld area on the pressurizer for the detection of PWSCC.

  • PDF

A Study on the Application of Phased Array Ultrasonic Testing to Main Steam Line in Nuclear Power Plants (원전 주증기배관 웰더렛 용접부 위상배열초음파검사 적용연구)

  • Lee, Seung-Pyo;Kim, Jin-Hoi
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.7 no.3
    • /
    • pp.40-47
    • /
    • 2011
  • KSNPs(Korea Standard Nuclear Power Plant) have been applied the break exclusion criteria to the high energy lines passing through containment penetration area to ensure that piping failures would not cause the loss of containment isolation function, and to reduce the resulting dynamic effects. Systems with the criteria are the Main Steam system, Feed Water system, Steam Generator Blowdown system, and Chemical & Volume Control system. In accordance with FSAR(Final Safety Analysis Report), a 100% volumetric examination by augmented in-service inspection of all pipe welds appled the break exclusion criteria is required for the break exclusion application piping. However, it is difficult to fully satisfy the requirements of inspection because 12", 8" and 6" weldolet weldments of Main Steam pipe line have complex structural shapes. To resolve the difficulty on the application of conventional UT(Ultrasonic Testing) technique, realistic mock-ups and UT calibration blocks were made. Simulations of conventional UT were performed utilizing CIVA, a commercial NDE(Nondestructive Examination) simulation software. Phased array UT experiments were performed through mock-up including artificial notch type flaws. A phased array UT technique is finally developed to improve the reliability of ultrasonic test at main steam line pipe to 12", 8" and 6" branch connection weld.