• 제목/요약/키워드: On-line diagnostics

검색결과 71건 처리시간 0.028초

Fused Polypeptide with DEF Induces Apoptosis of Lung Adenocarcinoma Cells

  • Liang, Ai-Ling;Zhang, Ting-Ting;Zhou, Ning;Huang, Di-Nan;Liu, Xin-Guang;Liu, Yong-Jun;Tu, Zhi-Guang
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제14권12호
    • /
    • pp.7339-7344
    • /
    • 2013
  • To analyze the effects of a new unknown peptide DEF on the growth of tumor cells, a fused polypeptide TAT-DV1-DEF was designed and synthesized. The lung adenocarcinoma cell line GLC-82 treated with TAT-DV1-DEF was analyzed with a cell counting kit 8, and the location of polypeptides in cells was observed under laser confocal microscopy. The efficiency of polypeptide transfection and changes in nuclear morphology were analyzed by flow cytometry and fluorescence microscopy, respectively. Finally, the mechanism of tumor cell growth inhibition was evaluated by Western blotting. We found that TAT-DV1-DEF could significantly inhibit the growth of the lung adenocarcinoma cell line GLC-82, but not the normal human embryonic kidney cell line HEK-293. Polypeptides were found to be mostly localized in the cytoplasm and some mitochondria. The efficiency of polypeptide transfection in the two cell types was approximately 99%. Apoptotic nuclei were observed under fluorescence microscopy upon treatment with polypeptides and DAPI staining. Western blot analyses indicated that the polypeptide inhibition of tumor cell growth was apoptosis dependent. In the present study, we demonstrated that fused polypeptides could induce apoptosis of the lung adenocarcinoma cell line GLC-82, indicating that the new unknown peptide DEF has antitumor effects.

HVAC에 의한 On-line, Off-line PD 모니터링 (On-line and Off-line Partial Discharge Monitoring System with HVAC Testing)

  • 최용성;이경섭
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2008년도 춘계학술대회 논문집 센서 박막재료연구회 및 광주 전남지부
    • /
    • pp.111-114
    • /
    • 2008
  • The paper considers the relation between on-line monitoring and diagnostics on the one hand and high-voltage (HV) withstand and partial discharge (PD) on-site testing on the other. HV testing supplies the basic data (fingerprints) for diagnostics. In case of warnings by on-line diagnostic systems, off-line withstand and PD testing delivers the best possible information about defects and enables the classification of the risk. Because alternating voltage (AC) is the most important test voltage, the AC generation on site is considered. Frequency tuned resonant (ACRF) test systems are best adapted to on-site conditions. They can be simply combined with PD measuring equipment. The available ACRF test systems and their application to electric power equipment -from cable systems to power transformers - is described.

  • PDF

전력 설비 시스템의 온라인 감시 (On-line Condition Monitoring for Electric Equipments)

  • 최용성;이경섭
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2008년도 춘계학술대회 논문집 센서 박막재료연구회 및 광주 전남지부
    • /
    • pp.103-105
    • /
    • 2008
  • In, this paper, we consider the relation between on-line monitoring and diagnostics on the one hand and high-voltage (HV) withstand and partial discharge (PO) on-site testing on the other. HV testing supplies the basic data (fingerprints) for diagnostics. In case of warnings by on-line diagnostic systems, off-line withstand and PO testing delivers the best possible information about defects and enables the classification of the risk. Because alternating voltage (AC) is the most important test voltage, the AC generation on site is considered. Frequency tuned resonant (ACRF) test systems are best adapted to on-site conditions. They can be simply combined with PO measuring equipment. The available ACRF test systems and their application to electric power equipment -from cable systems to power transformers - is described.

  • PDF

온라인 및 오프라인 PD 모니터링에 관한 연구 동향 (A Research Trend on On-Line/Off-Line PD Insulation Diagnostic System)

  • 추종훈;홍창일;최용성;이경섭
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 제38회 하계학술대회
    • /
    • pp.2008-2009
    • /
    • 2007
  • The paper considers the relation between on-line monitoring and diagnostics on the one hand and high-voltage (HV) withstand and partial discharge (PD) on-site testing on the other. HV testing supplies the basic data (fingerprints) for diagnostics. In case of warnings by on-line diagnostic systems, off-line withstand and PD testing delivers the best possible information about defects and enables the classification of the risk. Because alternating voltage (AC) is the most important test voltage, the AC generation on site is considered. Frequency tuned resonant (ACRF) test systems are best adapted to on-site conditions. They can be simply combined with PD measuring equipment. The available ACRF test systems and their application to electric power equipment -from cable systems to power transformers - is introduced.

  • PDF

Investigating the accretion disk properties of young radio galaxies using the narrow-emission line diagnostics

  • 손동훈;우종학;;;;;김상철
    • 천문학회보
    • /
    • 제36권1호
    • /
    • pp.49.2-49.2
    • /
    • 2011
  • To investigate whether radio galaxies have systematically different accretion disk compared to radio-quiet AGN, we obtained high quality optical spectra for a sample of 22 young radio galaxies, using the KAST Double Spectrograph at the Lick 3-m telescope. Young radio galaxies are particularly useful since the age of the radio phenomena is comparable to that of accretion disk. Based on the optical emission-line diagnostics of narrow line region, which is thought to be photoionized by the nuclear radiation, we constrain the states of the accretion disk. In addition to strong emission lines, i.e., [O I], [O II], [O III], and [Ne III], we use the [Ar III] line to break the degeneracy between the ionization parameter and the SED shape. We find that young radio galaxies show systematically different emission line ratios compared to radio-quiet Type II AGN, suggesting that young radio galaxies probably have the power-law SED without a strong big blue bump. We will present the main results of the emission-line diagnostics.

  • PDF

경근(經筋)과 인체 시상균형에 관한 소고(小考) (Meridian Sinews and Sagittal Spinal Balance)

  • 남동현;신상훈
    • 대한한의진단학회지
    • /
    • 제13권2호
    • /
    • pp.129-139
    • /
    • 2009
  • Sagittal spinal balance means standing postural balance at sagittal plane. Postural imbalance with displacement of the patient's center of gravity can cause chronic back pain and ambulatory difficulty. The sagittal spinal balance is determined based on the deviation of the C7 plumb line, originating at the middle of the C7 vertebral body, from the posterior superior endplate of S1. The line is called as sagittal vertical axis (SVA). In the traditional Korean medicine, the meridian sinews, which are the most superficial pathways of the meridian system, associated with movement, muscle balance and defense. They too are separate from the main meridians, though they intersect the main meridians. Some creative and pioneer researchers in Korea thought that the anatomy trains, which suggested by Myers is a concept familiar to the meridian sinews. A reciprocal relationship between the superficial back line and the superficial front line used to be compared to the rigging of a sailboat. Therefore, We suggest that spine may be compared to a mast of the sailboat and that the sagittal spinal balance can be maintained with systemic reciprocal interacts between the front line muscles and the back.

  • PDF

온라인 부분방전 감시 시스템 (On-Line System for Partial Monitoring Discharge)

  • 최용성;황종선;이경섭
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 제39회 하계학술대회
    • /
    • pp.2114-2115
    • /
    • 2008
  • We consider the relation between on-line monitoring and diagnostics on the one hand and high-voltage (HV) withstand and partial discharge (PD) on-site testing on the other. HV testing supplies the basic data (fingerprints) for diagnostics. In case of warnings by on-line diagnostic systems, off-line withstand and PD testing delivers the best possible information about defects and enables the classification of the risk. Frequency tuned resonant (ACRF) test systems are best adapted to on-site conditions. They can be simply combined with PD measuring equipment. The available ACRF test systems and their application to electric power equipment -from cable systems to power transformers is described.

  • PDF

배전반 설비의 온라인 모니터링 및 진단의 동향 (Trend in Off-Line PD Monitoring with HVAC Testing)

  • 윤주효;홍창일;황종선;최용성;이경섭
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2007년도 하계학술대회 논문집 Vol.8
    • /
    • pp.529-530
    • /
    • 2007
  • The paper considers the relation between on-line monitoring and diagnostics on the one hand and high-voltage (HV) withstand and partial discharge (PD) on-site testing on the other. HV testing supplies the basic data (fingerprints) for diagnostics. In case of warnings by on-line diagnostic systems, off-line withstand and PD testing delivers the best possible information about defects and enables the classification of the risk. Because alternating voltage (AC) is the most important test voltage, the AC generation on site is considered. Frequency tuned resonant (ACRF) test systems are best adapted to on-site conditions. They can be simply combined with PD measuring equipment. The available ACRF test systems and their application to electric power equipment -from cable systems to power transformers - is described.

  • PDF

The narrow emission-line properties of radio-loud AGNs in the SDSS archive

  • Son, Donghoon;Woo, Jong-Hak
    • 천문학회보
    • /
    • 제40권1호
    • /
    • pp.74.4-75
    • /
    • 2015
  • We investigate the narrow emission-line ratios of 64 radio-loud (log $L_{1.4GHz}$ > 40) AGNs available in the SDSS archive, in order to examine whether there is a systematic difference in the accretion disk condition of radio-loud AGNs compared to radio-quiet AGNs and compact young radio-loud AGNs. The fluxes of narrow-emission lines, [O II], [Ne III], [O III], [O I], [Ar III], are measured for diagnostics. Based on the [O I]/[O III] and [Ar III]/[O III] ratios with photoionization models, we constrain the states of the accretion disk. We will present the results of the emission-line diagnostics.

  • PDF

드릴링 작업의 모델링과 진단법에 관한 연구 (A Study on the Modeling and Diagnostics in Drilling Operation)

  • 윤문철
    • 동력기계공학회지
    • /
    • 제2권2호
    • /
    • pp.73-80
    • /
    • 1998
  • The identification of drilling joint dynamics which consists of drilling and structural dynamics and the on-line time series detection of malfunction process is substantial not only for the investigation of the static and dynamic characteristics but also for the analytic realization of diagnostic and control systems in drilling. Therefore, We have discussed on the comparative assessment of two recursive time series modeling algorithms that can represent the drilling operation and detect the abnormal geometric behaviors in precision roundshape machining such as turning, drilling and boring in precision diemaking. For this purpose, simulation and experimental work were performed to show the malfunctional behaviors for drilling operation. For this purpose, a new two recursive approach (Recursive Extended Instrument Variable Method : REIVM, Recursive Least Square Method : RLSM) may be adopted for the on-line system identification and monitoring of a malfunction behavior of drilling process, such as chipping, wear, chatter and hole lobe waviness.

  • PDF