• 제목/요약/키워드: On-line Condition Monitoring

검색결과 174건 처리시간 0.03초

MEMS 가속도계 기반 기계 상태감시용 스마트센서 개발 (Development of MEMS Accelerometer-based Smart Sensor for Machine Condition Monitoring)

  • 손종덕;양보석
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2007년도 춘계학술대회논문집
    • /
    • pp.448-452
    • /
    • 2007
  • Many industrial operations require continuous or nearly-continuous operation of machines, which if interrupted can result in significant financial loss. The condition monitoring of these machines has received considerable attention recent years. Rapid developments in semiconductor, computing, and communication with a remote site have led to a new generation of sensor called "smart" sensors which are capable of wireless communication with a remote site. The purpose of this research is the development of smart sensor using which can on-line perform condition monitoring. This system is addressed to detect conditions that may lead to equipment failure when it is running. Moreover it will reduce condition monitoring expense using low cost MEMS accelerometer. This sensor can receive data in real-time or periodic time from MEMS accelerometer. Furthermore, this system is capable for signal preprocessing task (High Pass Filter, Low Pass Filter and Gain Amplifier) and analog to digital converter (A/D) which is controlled by CPU. A/D converter that converts 10bit digital data is used. This sensor communicates with a remote site PC using TCP/IP protocols. Wireless LAN contain IEEE 802.11i-PSK or WPA (PSK, TKIP) encryption. Developed sensor executes performance tests for data acquisition accuracy estimations.

  • PDF

회전기계 파손에 따른 마멸 및 진동 특성(I) (An Experimental Study on the Wear and Vibrational Characteristics Resulted from Rotordynamics System Failure(I))

  • 강기홍;윤의성;장래혁;공호성;김승종;이용복;김창호
    • 한국윤활학회:학술대회논문집
    • /
    • 한국윤활학회 2001년도 제34회 추계학술대회 개최
    • /
    • pp.43-52
    • /
    • 2001
  • Condition monitoring plays a vital role since it sustains the reliable operation of industrial plant and machinery in the pursuit of economic whole life operation. In order to achieve this goal, it is needed to monitor various parameters of mechanical system such as vibration, wear, temperature, and etc., and finally to diagnosis the root causes of any possible abnormal machine condition. In this work, we constructed a rotor system where various types of functional machine failures occurred frequently in industry were induced. Characteristics of the machine failure were monitored simultaneously by the on-line measurement of vibration, wear and temperature. Result showed that these parameters responded differently to the induced functional machine failure. The availability of each parameter on effective condition monitoring was discussed in this work.

  • PDF

End Mill 가공시 공구 파손 검출에 관한 연구 (A Study on the Cutting Tool Fracture Monitoring in End Milling)

  • 채명병;맹민재;정준기
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 1994년도 추계학술대회 논문집
    • /
    • pp.26-31
    • /
    • 1994
  • The analysis of acoustic emission signals generated during machining has been proposed as a technique for studying both the fundamentals of the cutting process and process and as a methodology for detecting tool fracture on line. In this study, AE signals detected during End Milling were applied as the experimental test to sensing tool fracture on the CNC vertical milling machine. Because automatic monitoring of the cutting condition is one of the most important technologies in machining, the in-process detection of cutting tool life including fracture has been investigated by performing experimental test.

  • PDF

고압 전동기 고정자 권선의 운전중 절연감시 시스템 개발 (Development of On-tine Partial Discharge Monitoring System for High-Voltage Motor Stator Windings)

  • 황돈하;심우용;박도영;강동식;김용주;송상옥;김회동
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 추계학술대회 논문집 전기물성,응용부문
    • /
    • pp.224-226
    • /
    • 2001
  • In this paper, a novel high-voltage motor monitoring system (HVMMS) is proposed. This system monitors the insulation condition of the stator winding by on-line measurements of partial discharge (PD). Sensor, EMC (Epoxy-Mica Coupler) is used for PD measurement PD signals are continuously measured and digitized with a peak-hold A/D converter to build the database of the high-voltage motor's insulation condition. Also, this system can communicate with the central monitoring system via RS-485. This helps more efficient operation and maintenance of the generator.

  • PDF

연삭 숫돌 상태의 감시 진단에 관한 연구 (A Study on the Monitoring Technology of Prediction for Grinding Wheel Condition)

  • 이전헌;강재훈;김원일;이윤경;왕덕현
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 1994년도 추계학술대회 논문집
    • /
    • pp.125-130
    • /
    • 1994
  • Recently,manufacturing work been transformed to small acale production from with various items to act up to user's expectation from mass production with a little items required in the past. The FMS using NC type mother machinaries has been applied actively also in domestic manufacturing line to meet thus tendancy, but there are many machining troubles occured in work process not be settled yet. Nowdays high efficiency has been required no less than high precision in grinding work for the improvement of productivity. In this study, to represent more advanced FMS can be adapted to thus situation In-process type monitoring method using AE and Current sensors is suggested to investigatethe machining condition in grinding process. As results from this experimental study, is is recoqnized well that grinding conditions and dressing point of in time can be estimated effectively using monitoring method suggested. Furthermore, surface shape of grinding wheel on voluntary point of in time can be predicted indirectly through the observation and comparison of AE signal waveform obtained as performance of continuous dressing work.

  • PDF

The Feasibility Study on a High-Temperature Application of the Magnetostrictive Transducer Employing a Thin Fe-Co Alloy Patch

  • Heo, Tae-Hoon;Park, Jae-Ha;Ahn, Bong-Young;Cho, Seung-Hyun
    • 비파괴검사학회지
    • /
    • 제31권3호
    • /
    • pp.278-286
    • /
    • 2011
  • The on-line monitoring for the wall thinning in secondary system has been considered one of main issues for the safety of nuclear power plants. To establish the on-line monitoring technique for the pipe wall thinning, the development of the ultrasonic transducer working in high-temperature is very important. In this investigation, the magnetostrictive transducer is concerned for high temperature condition up to $300^{\circ}C$. The magnetostrictive transducer has many advantages such as high working temperature, durability, cost-effectiveness, and shear waves, most of all. A thin Fe-Co alloy patch whose Curie temperature is over $900^{\circ}C$ was employed as a ferromagnetic material for magnetostriction. Wave transduction experiments in various temperature were carried out and the effect of bias magnets was considered together with the dry coupling performance of the transducer. From experimental results, consequently, it was found that the magnetostrictive transducer works stable even in high temperature up to $300^{\circ}C$ and can be a promising method for the on-line monitoring of the wall thinning in nuclear power plants.

수서고속철도 전차선로의 설치조건의 따른 집전상태 분석 (Analysis of Current Collect Performance Depending on Installation Condition of Overhead Contact Line in Suseo High Speed Line)

  • 나경민;박영;이기원;조용현;권삼영;박철민
    • 전기학회논문지
    • /
    • 제66권4호
    • /
    • pp.727-732
    • /
    • 2017
  • This paper describes the dynamic characteristics depending on installation condition between a pantograph and an OCL (Overhead Contact Line) on a new high speed line in Korea. The current collection performance between the pantograph and the OCL was tested during train operation from Suseo to Jije stations. The current collection performance is evaluated based on the duration of an arc by using an arcing measurement system. The system consists of an optical sensor for measuring the duration of an arc and a camera for monitoring current collection performance. An arcing duration is defined as a percentage of arcing in international standards. This test aims to analyze the locations of repetitive arcing depending on installation conditions of OCLs on a new high speed line in order to use the result as reference data for correct construction and maintenance.

산업전기 설비의 상태 감시를 위한 자가 발전 센서 시스템의 설계 (Design of Self-Powered Sensor System for Condition Monitoring of Industrial Electric Facilities)

  • 이기창;강동식;전정우;황돈하;이주훈;홍정표
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 학술대회 논문집 정보 및 제어부문
    • /
    • pp.264-266
    • /
    • 2005
  • Recently, on-line diagnosis methods through wired and wireless networks are widely adopted in the diagnosis of industrial Electric Facilities, such as generators, transformers and motors. Also smart sensors which includes sensors, signal conditioning circuits and micro-controller in one board are widely studied in the field of condition monitoring. This paper suggests an self-powered system suitable for condition-monitoring smart sensors, which uses parasitic vibrations of the facilities as energy source. First, vibration-driven noise patterns of the electric facilities are presented. And then, an electromagnetic generator which uses mechanical mass-spring vibration resonance are suggested and designed. Finally energy consumption of the presented smart sensor, which consists of MEMS vibration sensors, signal conditioning circuits, a low-power consumption micro-controller, and a ZIGBEE wireless tranceiver, are presented. The usefulness and limits of the presented electromagnetic generators in the field of electric facility monitoring are also suggested.

  • PDF

Anticorrosive Monitoring and Complex Diagnostics of Corrosion-Technical Condition of Main Oil Pipelines in Russia

  • Kosterina, M.;Artemeva, S.;Komarov, M.;Vjunitsky, I.;Pritula, V.
    • Corrosion Science and Technology
    • /
    • 제7권4호
    • /
    • pp.208-211
    • /
    • 2008
  • Safety operation of main pipelines is primarily provided by anticorrosive monitoring. Anticorrosive monitoring of oil pipeline transportation objects is based on results of complex corrosion inspections, analysis of basic data including design data, definition of a corrosion residual rate and diagnostic of general equipment's technical condition. All the abovementioned arrangements are regulated by normative documents. For diagnostics of corrosion-technical condition of oil pipeline transportation objects one presently uses different methods such as in-line inspection using devices with ultrasonic, magnetic or another detector, acoustic-emission diagnostics, electrometric survey, general external corrosion diagnostics and cameral processing of obtained data. Results of a complex of diagnostics give a possibility: $\cdot$ to arrange a pipeline's sectors according to a degree of corrosion danger; $\cdot$ to check up true condition of pipeline's metal; $\cdot$ to estimate technical condition and working ability of a system of anticorrosive protection. However such a control of corrosion technical condition of a main pipeline creates the appearance of estimation of a true degree of protection of an object if values of protective potential with resistive component are taken into consideration only. So in addition to corrosive technical diagnostics one must define a true residual corrosion rate taking into account protective action of electrochemical protection and true protection of a pipeline one must at times. Realized anticorrosive monitoring enables to take a reasonable decision about further operation of objects according to objects' residual life, variation of operation parameters, repair and dismantlement of objects.

고압전동기 고정자권선의 부분방전 특징추출 (Feature Extraction of Partial Discharge for Stator Winding of High Voltage Motor)

  • 박재준;김희동;이동윤
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 추계학술대회 논문집 전기물성,응용부문
    • /
    • pp.112-116
    • /
    • 2004
  • On-line monitoring of fault discharge is an important approach for indicating the condition of electrical insulation of stator winding in high voltage motor. In this paper, several key aspects of on-line monitoring system are discussed, involving the characteristics of fault discharge of stator winding in high voltage motor, spectrum analysis of four simulation fault signals, feature extraction of internal fault discharge from apply voltage to breakdown. The study of the partial discharge activities allows to highlight the ageing stage in the winding fault under test. During the life of the winding insulation fault, the shape of PD signal change relating to the ageing stage. The ageing of stator winding insulation fault of high voltage motor is investigated based on the characteristics of partial discharge pulse distribution and statistical parameters, such as maximum, skewness and kurtosis using discrete wavelet transform coefficients.

  • PDF