• 제목/요약/키워드: On-line Condition Monitoring

검색결과 174건 처리시간 0.028초

ICT 기술을 융합한 자동차 실러도포 공정 모니터링 시스템 (Car Sealer Monitoring System Using ICT Technology)

  • 김호연;박종섭;박요한;조재수
    • 한국IT서비스학회지
    • /
    • 제17권3호
    • /
    • pp.53-61
    • /
    • 2018
  • In this paper, we propose a car sealing monitoring system combined with ICT Technology. The automobile sealer is an adhesive used to bond inner and outer panels of doors, hoods and trunks of an automobile body. The proposed car sealer monitoring system is a system that can accurately and automatically inspect the condition of the automobile sealer coating process in the general often factory production line where the lighting change is very severe. The sealer inspection module checks the state of the applied sealer using an area scan camera. The vision inspection algorithm is adaptive to various lighting environments to determine whether the sealer is defective or not. The captured images and test results are configured to send the task results to the task manager in real-time as a smartphone app. Vision inspection algorithms in the plant outdoors are very vulnerable to time-varying external light sources and by configuring a monitoring system based on smart mobile equipment, it is possible to perform production monitoring regardless of time and place. The applicability of this method was verified by applying it to an actual automotive sealer application process.

Flashover Prediction of Polymeric Insulators Using PD Signal Time-Frequency Analysis and BPA Neural Network Technique

  • Narayanan, V. Jayaprakash;Karthik, B.;Chandrasekar, S.
    • Journal of Electrical Engineering and Technology
    • /
    • 제9권4호
    • /
    • pp.1375-1384
    • /
    • 2014
  • Flashover of power transmission line insulators is a major threat to the reliable operation of power system. This paper deals with the flashover prediction of polymeric insulators used in power transmission line applications using the novel condition monitoring technique developed by PD signal time-frequency map and neural network technique. Laboratory experiments on polymeric insulators were carried out as per IEC 60507 under AC voltage, at different humidity and contamination levels using NaCl as a contaminant. Partial discharge signals were acquired using advanced ultra wide band detection system. Salient features from the Time-Frequency map and PRPD pattern at different pollution levels were extracted. The flashover prediction of polymeric insulators was automated using artificial neural network (ANN) with back propagation algorithm (BPA). From the results, it can be speculated that PD signal feature extraction along with back propagation classification is a well suited technique to predict flashover of polymeric insulators.

가스터빈 엔진 정비 의사결정 지원시스템 개발 (A Development of Maintenance Decision Support System for Gas Turbine Engine)

  • 기자영;강명철;이명국;노홍석
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2012년도 제38회 춘계학술대회논문집
    • /
    • pp.586-591
    • /
    • 2012
  • 군산 복합화력 발전소에서 운용중인 가스터빈 엔진의 정비 의사 결정을 지원하기 위한 솔루션을 개발하였다. 솔루션은 온라인 상태감시, 기간별 성능 경향분석, 최적 압축기 세정주기 분석, 고온부품 관리 모듈로 구성되어 있다. 운용자가 엔진의 상태 분석 결과를 쉽게 모니터하고 그에 따른 정비의사를 결정할 수 있도록 GUI 플랫폼을 적용하였다. 온라인 상태감시 모듈에서는 기준 성능 대비 실시간 계측데이터의 차이를 분석하여 엔진의 성능저하율을 가시적으로 제시한다. 최적 압축기 세정주기 분석 모듈에서는 경제성 평가 알고리즘을 통해 정비 소요 비용과 성능 저하에 따른 비용 손실의 분석을 통해 순이익이 최대가 되는 세정주기를 제시한다. 엔진의 상태 및 주요 정보를 종합적으로 분석하여 제공함으로써 최적 정비 및 운용이 가능하도록 의사 결정을 지원한다.

  • PDF

Zigbee 무선통신을 이용한 UPS DC링크 커패시터의 고장 모니터링 시스템 개발 (A development of Diagnosis Monitoring System for UPS DC Link Capacitors using Zigbee Wireless Communication)

  • 김동준;손진근;전희종
    • 전기학회논문지P
    • /
    • 제61권1호
    • /
    • pp.41-46
    • /
    • 2012
  • Electrolytic power capacitors have been widely used in power conversion system such as inverter or UPS because of characteristics of large capacitance, high-voltage and low-cost. The electrolytic capacitor, which is most of the time affected by the aging effect, plays a very important role for the power-electronics system quality and reliability. Therefore it is important to diagnosis monitoring the condition of an electrolytic capacitor in real-time to predict the failure. In this paper, the on-line remote diagnosis monitoring system for UPS DC link electrolytic capacitors using low-cost single-chip zigbee communication modules is developed. To estimate the health status of the capacitor, the equivalent series resistor(ESR) of the component has to be determined. The capacitor ESR is estimated by using RMS computation using BPF modeling of DC link ripple voltage/current. Zigbee-based hardware experimental results show that the proposed remote capacitor diagnosis monitoring system can be applied to UPS successfully.

SCADA 기능과 전기품질 온라인 감시 및 배전설비 열화감시 기능을 갖는 배전지능화 시스템 개발 (Development of intelligent distribution automation system with the function of substation SCADA, power quality monitoring and diagnosis condition monitoring)

  • 하복남;이성우;신창훈;서인용;장문종;박민호;윤기갑;송일근;이병성;이정철;남궁원
    • 전기학회논문지
    • /
    • 제59권10호
    • /
    • pp.1776-1786
    • /
    • 2010
  • Intelligent distribution automation system have total monitoring and control capability. The system covers substation, distribution network, distributed generations and customers at HV system. Various intelligent distribution facilities installed at distribution systems have voltage sensor, current sensor, aging monitoring sensor. Intelligent Feeder Remote Terminal Unit (IFRTU) tied to intelligent distribution facilities process information from facilities and it checks information of fault, power quality and aging of distribution facilities. The information is transmitted to master station through communication line. The master station have remote monitoring system covers substation, distribution network, distributed generations and customers. It also have various application programs that maintain optimal network operation by using information from on-site devices.

변압기 누설전류 통합 감시장치 (Total monitoring device of leakage current in transformer)

  • 이정은;최홍규;염성배;박형민;유해출;홍성구;신혜영
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2009년도 춘계학술대회 논문집
    • /
    • pp.360-363
    • /
    • 2009
  • 변압기 누설전류 통합 감시 장치는 변압기 중성선에 흐르는 누설전류를 검출하여 실시간으로 모니터링이 가능한 장치로, 지정 값 이상의 누설전류가 검출되면 관리자에게 경보함으로써 전기적인 사고를 사전에 예방할 수 있다. 본 논문에서는 변압기 누설전류 통합 감시장치에 대해 설명하고, 국내 현재 설비상황 및 실제 사고 사례를 통해 변압기 누설전류 통합 강시장치의 필요성에 대해 설명하였다.

  • PDF

암반 등급 변화에 따른 터널 내공 변위 거동 특설 (Characteristics of Tunnel Convergence Behaviour based on Variation of Rock Mass Rating)

  • 김광염
    • 지질공학
    • /
    • 제18권4호
    • /
    • pp.545-553
    • /
    • 2008
  • 터널 시공 중 막장관찰과 계측자료는 굴착으로 인하여 발생하는 지반 및 주변 구조물의 안정성 평가를 위한 가장 중요한 정보이다. 특히, 발파 굴착으로 이루어지는 NATM 공법에서 막장관찰과 계측은 다음 막장의 굴착 및 지보설계를 위한 핵심자료로 활용이 된다. 하지만, 국내에는 암반분류 결과와 계측결과의 관계에 대한 연구가 많이 부족하여 굴착 및 지보설계에 제대로 활용되지 못하고 있는 실정이다. 본 연구에서는 막장관찰에 의한 암반분류 중 국내외에서 가장 많이 사용되는 RMR 분류법과 내공변위 계측결과의 분석을 통해 지질상태의 변화가 터널의 거동에 미치는 영향을 살펴보고자 하였다. 내공변위의 계측위치와 계측 시점에 따른 변위 측정 편차를 변위 함수를 이용해 보정하였으며, 이를 통해 내공변위의 영향선과 지반조건의 관계를 고찰하였다. 또한 변위 함수 파라미터와 초기변위 발생비율 등 내공변위와 관련된 다양한 요소들의 지반조건에 따른 변화양상을 파악함으로써 막장관찰 및 내공변위 계측을 통한 지반 평가의 기초자료를 제시하고자 하였다.

산림수문환경(山林水文環境) 모니터링을 위(爲)한 원거리(遠距離) 자동관측(自動觀測)시스템의 개발(開發) - 하드웨어를 중심(中心)으로 - (Developing an On-Line Monitoring System for a Forest Hydrological Environment - Development of Hardware -)

  • 이헌호;석수일
    • 한국산림과학회지
    • /
    • 제89권3호
    • /
    • pp.405-413
    • /
    • 2000
  • 본 연구는 산림 기상 수문 환경의 모니터링을 위해 온도, 풍향, 풍속, 강우량, V노치의 수위, 계류수의 전기전도도 및 pH 등의 인자를 대상으로 하여 마이크로프로세서에 의한 전동식 센서유니트를 작동시켜 자동관측이 가능한 시스템을 개발하고자 실시하였으며, 그 결과는 다음과 같다. 1. 관측시스템은 크게 신호처리부, 전동식센서부, 전원제어부 그리고 무선데이터 통신부로 구성하였다. 2. 웨어부착형 전동식 센서유니트를 채택하여 계류수의 결빙 및 급류에 의한 센서의 파손을 방지하도록 하였으며, 동시에 항상 일정한 수위에서 측정이 이루어지도록 하였다. 3. 관측시스템에서 데이터의 전송은 무선 모뎀을 사용하여 산림유역의 수문 상황을 실시간 모니터링이 가능하도록 하였다. 4. 관측시스템은 각 기능별 독립구조의 모듈형태로 구성하여 측정 모듈의 수리, 교체, 추가 등의 변경이 가능하도록 하였다. 5. 관측시스템의 성능 시험을 실시한 결과 온도, EC, pH는 각각 최대 ${\pm}0.2^{\circ}C$, ${\pm}1{\mu}S$, ${\pm}0.1pH$의 오차범위 내에서 관측되었다. 6. 현장에서 관측시스템을 시험 운영해 본 결과 장기적이고 안정적인 산림 수문 수질 인자의 측정이 가능할 것으로 평가되었다.

  • PDF

수력발전기 고정자 권선의 운전중 부분방전 특성 (Properties of On-Line Partial Discharge in Hydrogenerator Stator Windings)

  • 김병한;김희동
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제55권4호
    • /
    • pp.172-177
    • /
    • 2006
  • During normal machine operation, partial discharge(PD) tests were performed with partial discharge analyzer(PDA) in two hydrogenerators. Six cable couplers were installed in circuit ring bus and endwinding of three phases. PDA showed that the normalized quantity number(NQN) and the partial discharge magnitude$(Q_m)$ were very low in hydrogenerator #1 and #2, respectively. The trend analyses of NQN and $Q_m$ value are available for monitoring of the insulation condition in hydrogenerator stator windings. The insulation condition of stator winding can be assessed. Discharge at conductor surface was discovered in B phase(C2 coupler) of hydrogenerator #1. Internal discharges were generated in A and C phases(C2 coupler) of hydrogenerator #1 and in A, Band C phases(C1 and C2 couplers) of hydrogenerator #2. Slot discharges occurred in A, Band C phases(C1 coupler) of hydrogenerator #1. The stator windings of two hydrogenerators were in good condition.

불평형전류 측정에 의한 회전기 열화감시장치 (Deterioration Monitoring Device by Unbalance Current Measurement of Rotating Machines)

  • 박찬용;박대원;류길수;길경석;이강원
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2008년도 춘계학술대회 논문집
    • /
    • pp.2035-2039
    • /
    • 2008
  • This paper described an on-line condition monitoring device for rotating machines by measurement of unbalance current due to insulation deterioration. The device consists of a zero-phase current transformer (ZCT), a low-noise amplifying circuit, and a microprocessor unit. The prototype device measures current of $500\;{\mu}A\;{\sim}\;30\;mA$ in frequency ranges from 10 Hz to 3 kHz. An application experiment was carried out on 3-phase induction motors and we could measure current changes caused by a short-circuited turn.

  • PDF