• Title/Summary/Keyword: On-current

Search Result 53,975, Processing Time 0.067 seconds

Gate Tunneling Current and QuantumEffects in Deep Scaled MOSFETs

  • Choi, Chang-Hoon;Dutton, Robert W.
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.4 no.1
    • /
    • pp.27-31
    • /
    • 2004
  • Models and simulations of gate tunneling current for thinoxide MOSFETs and Double-Gate SOIs are discussed. A guideline in design of leaky MOS capacitors is proposed and resonant gate tunneling current in DG SOI simulated based on quantum-mechanicalmodels. Gate tunneling current in fully-depleted, double-gate SOI MOSFETs is characterized based on quantum-mechanical principles. The simulated $I_G-V_G$ of double-gate SOI has negative differential resistance like that of the resonant tunnel diodes.

A study on the threshold current ratio method using the measurement of coated facet reflectivity of a laser diode (레이저 다이오드의 코팅된 단면의 반사율 측정에 사용되는 문턱전류비에 관한 연구)

  • Lee, Sang-Moo;Kim, Boo-Gyoun
    • Proceedings of the KIEE Conference
    • /
    • 1995.11a
    • /
    • pp.541-543
    • /
    • 1995
  • We propose the improved threshold current ratio method to determine the reflectivity of coated facets. The carrier recombination time used in the improved threshold current ratio method depends on the value of facet reflectivities. However, the carrier recombination time used in the conventional threshold current ratio method is constant regardless of facet reflectivities. The difference between the results of the two methods increases as the reflectivity of a coated facet decreases.

  • PDF

Deposition of copper oxide by reactive magnetron sputtering

  • Lee, Jun-Ho;Lee, Chi-Yeong;Lee, Jae-Gap
    • Proceedings of the Materials Research Society of Korea Conference
    • /
    • 2010.05a
    • /
    • pp.49.2-49.2
    • /
    • 2010
  • Copper oxide films have been deposited on silicon substrates by direct current magnetron sputtering of Cu in O2 / Ar gas mixtures. The target oxidation occurring as a result of either adsorption or ion-plating of reactive gases to the target has a direct effect on the discharge current and the resulting composition of the deposited films. The kinetic model which relates the target oxidation to the discharge current was proposed, showing the one-to-one relationship between discharge current characteristics and film stoichiometry of the deposited films.

  • PDF

Junction, Circuit and System Developments for a High-$T_c$ Superconductor Sampler

  • Hidaka, M.;Satoh, T.;Tahara, S.
    • Progress in Superconductivity
    • /
    • v.1 no.2
    • /
    • pp.81-84
    • /
    • 2000
  • A Josephson sampler circuit using high-Tc superconductor (HTS) ramp-edge junctions has been designed, fabricated, and experimentally tested. It consists of five ramp-edge junctions with a stacked groundplane and is based on single-flux-quantum (SFQ) operations. The sampler was used to measure current waveforms at picosecond and microampere resolutions. We are developing a system based on the sampler for measuring the current waveform in a room-temperature sample. And measuring current flowing through wiring in a semiconductor large-scale integrated circuit is a promising application for the HTS sampler system.

  • PDF

Application of the Fault current detector to High speed circuit breaker (고속도 차단기에 대한 사고전류 감지기의 적용연구)

  • 이우영;송기동;박경엽
    • Proceedings of the Korea Institute of Applied Superconductivity and Cryogenics Conference
    • /
    • 2003.10a
    • /
    • pp.222-225
    • /
    • 2003
  • In this paper the performance of the high speed circuit breaker with fault current detector is described. The operating mechanism of circuit breaker in use is a magnetic actuator and a fault current detector is based on the DSP and A/D converter. The results show that 3-cycle is enough to interrupt the fault current and the more speed up performance is expected with on-going project.

  • PDF

Effect of pH on the ATP-sensitive $K^+$ Channel in Aortic Smooth Muscle Cells from Rats

  • Kim, Se-Hoon;Kim, Il-Su;Kim, Hoe-Suk;Jeon, Byeong-Hwa;Chang, Seok-Jong
    • The Korean Journal of Physiology and Pharmacology
    • /
    • v.1 no.5
    • /
    • pp.555-563
    • /
    • 1997
  • The effects of pH on $K^+$ currents were investigated in single smooth muscle cells isolated from the thoracic aorta of Wistar-Kyoto rats. Whole-cell $K^+$ currents were recorded in the conventional configuration of the voltage-clamp technique. Pinacidil (10uM) activated the whole-cell current and the pinacidil-activated current was completely inhibited by glibenclamide (10uM) , an inhibitor of ATP-sensitive $K^+$ channel ($K_{ATP}$ channel). Pinacidil-activated current was reversed at near the $K^+$ equilibrium potential. This current was time- and voltage-independent and reduced by elevating intracellular ATP. Pinacidil-activated current was reduced by lowering the external pH. However, alteration of internal pH has controversial effects on pinacidil-activated current. When the single cell was dialyzed with 0.1 mM ATP, alteration of internal pH had no effect on pinacidil-activated $K^+$ current. In the contrast, when the single cell was dialyzed with 3 mM ATP, pinacidil-activated current was increased by lowering internal pH. Our results suggest that $K^+$ channel activated by pinacidil may be $K_{ATP}$ channel and internal $H^+$ may reduce the inhibitory effect of ATP on $K_{ATP}$ channel.

  • PDF

The Study on Eddy Current Characteristic for Surface Defect of Gas Turbine Rotor Material (가스터빈 로터 재질에 따른 표면결함 와전류 특성연구)

  • Ahn, Y.S.;Gil, D.S.;Park, S.G.
    • Journal of Power System Engineering
    • /
    • v.14 no.4
    • /
    • pp.63-67
    • /
    • 2010
  • This paper introduces the eddy current signal characteristic of magnetic and non-magnetic gas turbine rotor. In the past, Magnetic particle inspection method was used in magnetic material for qualitative defect evaluation and the ultrasonic test method was used for quantitative evaluation. Nowadays, eddy current method is used in magnetic gas turbine rotor inspection due to advanced sensor design technology. We are studying on the magnetic gas turbine rotor by using eddy current method. We prepared diverse depth specimens made by magnetic and non-magnetic materials. We select optimum frequency according to material standard penetration data and experiment results. We got the signal on magnetic and non-magnetic material about 0.2 mm, 05 mm, 1.0 mm, 1.5 mm 2.0 mm and 2.5 mm depth defects and compare the signal amplitude and signal trend according to defect depth and frequency. The results show that signal amplitudes of magnetic are bigger than non-magnetic material and the trends are similar on every defect depth and frequency. The detection and resolution capabilities of eddy current are more effective in magnetic material than in non-magnetic materials. So, the eddy current method is effective inspection method on magnetic gas turbine rotor. And it has the merits of time saving and simple procedure by elimination of the ultrasonic inspection in traditional inspection method.

A Simplified Synchronous Reference Frame for Indirect Current Controlled Three-level Inverter-based Shunt Active Power Filters

  • Hoon, Yap;Radzi, Mohd Amran Mohd;Hassan, Mohd Khair;Mailah, Nashiren Farzilah;Wahab, Noor Izzri Abdul
    • Journal of Power Electronics
    • /
    • v.16 no.5
    • /
    • pp.1964-1980
    • /
    • 2016
  • This paper presents a new simplified harmonics extraction algorithm based on the synchronous reference frame (SRF) for an indirect current controlled (ICC) three-level neutral point diode clamped (NPC) inverter-based shunt active power filter (SAPF). The shunt APF is widely accepted as one of the most effective current harmonics mitigation tools due to its superior adaptability in dynamic state conditions. In its controller, the SRF algorithm which is derived based on the direct-quadrature (DQ) theory has played a significant role as a harmonics extraction algorithm due to its simple implementation features. However, it suffers from significant delays due to its dependency on a numerical filter and unnecessary computation workloads. Moreover, the algorithm is mostly implemented for the direct current controlled (DCC) based SAPF which operates based on a non-sinusoidal reference current. This degrades the mitigation performances since the DCC based operation does not possess exact information on the actual source current which suffers from switching ripples problems. Therefore, three major improvements are introduced which include the development of a mathematical based fundamental component identifier to replace the numerical filter, the removal of redundant features, and the generation of a sinusoidal reference current. The proposed algorithm is developed and evaluated in MATLAB / Simulink. A laboratory prototype utilizing a TMS320F28335 digital signal processor (DSP) is also implemented to validate effectiveness of the proposed algorithm. Both simulation and experimental results are presented. They show significant improvements in terms of total harmonic distortion (THD) and dynamic response when compared to a conventional SRF algorithm.

Effects of Lightning Surges on the Life of ZnO Varistors (뇌서지가 ZnO바리스터에 미치는 영향)

  • Lee, Bong;Lee, Su-Bong;Kang, Sung-Man;Lee, Bok-Hee
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.55 no.5
    • /
    • pp.257-262
    • /
    • 2006
  • To evaluate the change in protective levels of zinc oxide (ZnO) varistors after the surge absorption, this paper investigated the effects of the number of injection and amplitude of lightning surges on the life of ZnO varistors for low voltages. Leakage currents flowing through ZnO varistors subjected to the $8/20{\mu}s$ impulse currents under 60 Hz AC voltages were measured. The surge simulator system ECAT that can generate $8/20{\mu}s$ impulse currents with a peak short-circuit of 5 $[kA_p]$ was used. The ZnO varistor leakage current increases with exposure to impulse current, and the number of injection of $8/20{\mu}s$ impulse currents to breakdown was inversely proportional to the amplitude of the test current. Behaviors of ZnO varistor leakage currents were strongly dependent on the number of injection and amplitude of $8/20{\mu}s$ impulse currents. ZnO varistors degrade gradually when subjected to impulse current, and the resistive leakage current flowing through ZnO varistors subjected to the $8/20{\mu}s$ impulse currents under 60 Hz AC voltages was significantly increased after a certain number of injection that is dependent on the amplitude of the test impulse current. As a result, the life of ZnO varistors mainly depends on the amplitude and occurrence frequency of lightning surges.

Simple On-line Elimination Strategy of Dead Time and Nonlinearity in Inverter-fed IPMSM Drive Using Current Slope Information (IPMSM 드라이브에서 전류 기울기 정보를 이용한 데드타임 및 인버터 비선형성 효과의 간단한 제거 기법)

  • Park, Dong-Min;Kim, Myung-Bok;Kim, Kyeong-Hwa
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.17 no.5
    • /
    • pp.401-408
    • /
    • 2012
  • A simple on-line elimination strategy of the dead time and inverter nonlinearity using the current slope information is presented for a PWM inverter-fed IPMSM (Interior Permanent Magnet Synchronous Motor) drive. In a PWM inverter-fed IPMSM drive, a dead time is inserted to prevent a breakdown of switching device. This distorts the inverter output voltage, resulting in a current distortion and torque ripple. In addition to the dead time, inverter nonlinearity exists in switching devices of the PWM inverter, which is generally dependent on operating conditions such as the temperature, DC link voltage, and current. The proposed scheme is based on the fact that the d-axis current ripple is mainly caused by the dead time and inverter nonlinearity. To eliminate such an influence, the current slope information is determined. The obtained current slope information is processed by the PI controller to estimate the disturbance caused by the dead time and inverter nonlinearity. The overall system is implemented using DSP TMS320F28335 and the validity of the proposed algorithm is verified through the simulation and experiments. Without requiring any additional hardware, the proposed scheme can effectively eliminate the dead time and inverter nonlinearity even in the presence of the parameter uncertainty.