• 제목/요약/키워드: On-current

검색결과 53,517건 처리시간 0.068초

새로운 Zero-Current-Transition PWM DC/DC 컨버터 (Novel Zero-Current-Transition PWM DC/DC Converters)

  • 이민광;이동윤;현동석
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제50권2호
    • /
    • pp.79-85
    • /
    • 2001
  • In this paper, a novel Zero-Current-Transition (ZCT) technique, which provides Zero-Current-Switching (ZCS) turn-off of the main switch, the main diode and the auxiliary switch, is presented. The proposed auxiliary circuit consists of minimum elements only one auxiliary switch, resonant inductor and resonant capacitor. Also the reduced di/dt, which is obtained by resonant inductor, helps soft turn-on of the main switch. Besides, to eliminate the additional conduction loss and current stress on main switch, a topological variation was performed. The theoretical analysis and the operation principle of the new ZCT techniques are described in detail with a boost converter as an example. To verify the validity of the proposed ZCT techniques, the simulation and the experiment were performed under 1kW output power and 100kHz switching frequency.

  • PDF

R&D trends of high current REBCO conductor

  • Oh, Sang-Soo
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제24권1호
    • /
    • pp.1-7
    • /
    • 2022
  • So far, large-scale scientific devices such as nuclear fusion tokamaks and high energy circular accelerators were constructed using high-current conductors made of metallic superconducting wires. Recently, as REBCO superconducting wires usable in high magnetic fields have been developed by several companies, researchesto apply high current cable type REBCO conductors to next-generation large superconducting magnets were also started. High critical currents of several kA or more in high magnetic fields have been successfully demonstrated on test samples of REBCO cable conductors by several research groups. In this review article, the main features and properties of the representative high current REBCO conductors such as CORC(Conductor On Round Core), TSTC(Twisted Stacked-Tape Cable) and RACC(Roebel-Assembled Coated Conductor), which are currently being developed at abroad are briefly introduced. Research activities of high-current density REBCO MHOS(Multi HTS layers on One Substrate) conductor at KERI, whose structure is different from other cable type REBCO conductors are also shortly introduced.

사고전류 제한형 고온 초전도케이블의 한류부 특성평가 (Evaluation on the Properties of the Current Limiting Part for Fault-Current-Limiting Type HTS Cables)

  • 김태민;홍공현;한병성;두호익
    • 한국전기전자재료학회논문지
    • /
    • 제28권3호
    • /
    • pp.191-195
    • /
    • 2015
  • Inside the existing superconducting cables, the superconducting wire carries a loss-free current, and the cable former (the stranded copper wire) bypasses the fault current to prevent damage and loss of the superconducting cable when the fault current is applied. The fault-current-limiting-type superconducting cable proposed in this paper usually carries a steady current; but in a fault state, the cable generates self-resistance that makes the fault current lower than a certain width. That is, the superconducting cable that transmitted only a low voltage and a large capacity power repetitively limits the fault current, as does a superconducting current limiter. To complete this structure, it is essential to investigate the mutual resistance relationship between the superconducting wires after applying a fault current. Therefore, in this paper, one kinds of superconducting wires (a wire without a stabilization layer) were connected parallel 4 tapes, respectively; and after applying a fault current, the current, voltage, resistance and thermal stability of the HTS thin-film wires were examined.

저항성 누전전류에 의하여 동작하는 새로운 누전차단기 (The New Residual Current Protective Devices Operating by Resistive Leakage Current)

  • 함승진;한송엽;고창섭
    • 전기학회논문지
    • /
    • 제57권2호
    • /
    • pp.198-207
    • /
    • 2008
  • The conventional Residual Current Protective Devices(RCD, or earth leakage circuit breaker, ELB) operates depending on the total leakage current which is the vector-sum of resistive and capacitive components of a leakage current. However, the electric disaster such as electric shock or fire is mainly caused by the resistive component. Therefore, in this view point, the RCD is more realistic when it operates by the resistive component of the leakage current. In this paper, a new algorithm for measuring the resistive leakage current from the total leakage current is suggested, and is realized to an actual circuit. According to the suggested algorithm, the resistive component of the leakage current can be found by integrating the total leakage current over only a half cycle of the line voltage, and it is realized by using analog switches and resettable integrators. It is confirmed through experiments that the suggested algorithm detects, within maximum average error of 6.74%, the resistive leakage current from the total leakage current, and the RCD employing the suggested algorithm brakes the circuit within the regular interrupt time(30msec).

Phase Current Reconstruction Techniques for Two-Phase Inverters using a Single Current Sensor

  • Cho, Young-Hoon;Cho, Kwan-Yuhl;Mok, Hyung-Soo;Kim, Kyeong-Hwa;Lai, Jih-Shen
    • Journal of Power Electronics
    • /
    • 제11권6호
    • /
    • pp.837-845
    • /
    • 2011
  • This paper proposes phase current reconstruction techniques for two-phase two-leg and two-phase four-leg inverters using a single current sensor. In the proposed methods, one phase current is sampled simultaneously with a particular branch current by using only one current sensor, and then current reconstruction algorithms are applied to extract the information on two phase currents from the sensor output. The sampled current information is periodically updated at the peak and the valley of the triangular carrier waveform in each switching cycle of pulse-width modulation (PWM). The voltage vector spaces where the phase currents can be reconstructed are evaluated. Compared to the existing method using two individual current sensors in two phases, the proposed schemes can save implementation cost since it is possible to remove one current sensor. In addition, the proposed methods are free from gain discrepancy issues between two current sensors. Simulations and experiments show excellent current reconstruction performance of the proposed methods.

영양사 국가시험 과목의 학제별 개설 운영 실태 및 영양사 국가시험과의 상관성 분석 (The Analysis of the National Examination for Dietitian's License by Educational System)

  • 박상현;정현아;백재은;주나미
    • 한국식품영양학회지
    • /
    • 제26권2호
    • /
    • pp.234-241
    • /
    • 2013
  • The purpose of this research was to suggest a category and level of national examination for dietitian's license and provide basic data for the development of national examination question by analyzing the current states on the curriculum of national examination for the dietitian's license and correlation with the current states on curriculum and national examination for the dietitian's license. The higher the current states on curriculum, the lower absentee rate and failing rate of the national examination for the dietitian's license. The higher the current states on curriculum, the higher pass rate of the national examination for the dietitian's license. Also, the current states on curriculum were positive relationship with correct answer rates. The higher the educational system, the higher the current states on curriculum. The educational system was negative relationship with the current states on curriculum of 'public health', 'advanced nutrition', 'food science', 'principles of culinary', and 'food sanitary law (p<0.05)'. The correct answers rates of 'institutional foodservice' were significantly positive relationship with the current states on curriculum of 'institutional foodservice (p<0.01)', 'foodservice organization (p<0.01)', 'food sanitation (p<0.05)', and 'practice in foodservice institutions (p<0.01)'. The pass rate was significantly positive relationship with the correct answer rates of 'institutional foodservice (p<0.01)', 'physiology (p<0.01)', 'biochemistry (p<0.01)', 'food sanitary law (p<0.01)', 'food science and preparation (p<0.05)', 'nutrition education (p<0.01)', 'nutrition (p<0.01)', and 'total score (p<0.05)'.

열처리 후 가해진 스트레스가 산화막 누설전류에 미치는 영향 (Effects of re-stress after anneal on oxide leakage)

  • 이재호;김병일
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 1998년도 추계종합학술대회 논문집
    • /
    • pp.593-596
    • /
    • 1998
  • Effects of current re-stress after anneal on leakage current and trapped charges in oxides are investigated. Current stress on 6 nm thick oxide has generated mostly positive traps within the oxide resulting in leakage currents. The interface states generated are several orders of magnitude smaller, determined by C-V and charge pumping method. Annealing has eliminated only the charged traps not the neutral traps, thus the leakage current and trap density are increased when the oxides are re-stressed.

  • PDF

The Effect of Train Motion on Current Collection in High-speed Train

  • Kim, Jung-Soo
    • International Journal of Safety
    • /
    • 제5권1호
    • /
    • pp.1-4
    • /
    • 2006
  • The safety performance of the current collection system is evaluated by conducting a test run in which accelerometer and load cell signals are analyzed. It has been found that the current collection performance is strongly influenced by the train speed, with the major frequency components arising from the train traversing the span spacing and the 8.5 Hz component originating from the panhead resonance. The train acceleration is found to have significant influence on the span passing frequency but negligible effect on the resonant response.

Reduction of Leakage current Generated by Degradation in Organic Thin Film Transistors using Pattern on Pentacene Surface by Atomic Force Microscope

  • Hwang, Hyun-Doo;Kim, Hyun-Suck;Kim, Chang-Ho;Kim, Jae-Hoon
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2009년도 9th International Meeting on Information Display
    • /
    • pp.560-562
    • /
    • 2009
  • In this paper, we proposed a simple method of decreasing the off current generated by degradation for improve the electrical characteristics such as mobility and on/off current ratio by making the line patterns on the pentacene surface between the electrodes using atomic force microscope (AFM) lithography.

  • PDF

고정상 담체를 충진한 BER에서 HRT, 전류밀도 및 담체 충진율 변화가 질산성 질소 제거효율과 전류이용효율에 미치는 영향 (The effect of HRT, current density, and packing ratio on nitrate nitrogen removal efficiency and current efficiency in BRM-BER)

  • 황규대;이상근;성해창
    • 상하수도학회지
    • /
    • 제24권4호
    • /
    • pp.433-442
    • /
    • 2010
  • BER at different packing ratios of bio-ring media(BRM) was tested to investigate the effect of varying hydraulic retention time (HRT) and current density on the nitrate removal and current efficiency. In the preliminary batch mode experiment of BERs, current density was applied at 2.0 A/$m^2$, 4.0 A/$m^2$, 4.8 A/$m^2$, which correspond to the designation of reactor #1, #2, #3, respectively. The reactor #2 showed a highest nitrate removal rate of 162.0 mg $NO_3{^-}$-N/L/d, and the kinetics of nitrate removal rate was defined as the Zero order reaction. In the primary experiment of BERs, four BERs packed with BRM were operated in varying HRT and current, and the packing ratios of reactor #1, #2, #3 and #4 were 0%, 8%, 16%, 24%. respectively. This results of the experiments indicated that the nitrate removal rate and current efficiency were increased significantly cause of growing of autotrophic denitrification microorganisms on the surface of cathode and media by increasing of the current density and decreasing of HRT. However, The decreasing of nitrate removal rate and current efficiencies were observed in the condition of HRT of 5.25 hr and 4.8 A/$m^2$ of current density. With more increasing current density and decreasing of HRT, the hydrogen inhibition occurred at the surface of cathode. Moreover, nitrate removal rate by autotrophic denitrification microorganisms attached on the media surface was observed to be limited by no longer increasing dissolved hydrogen concentration of each reactor. In conclusion, the highest nitrate nitrogen removal and current efficiency could be achieved when the BER was operated at the conditions of 7 hr HRT, current density of 4.0 A/$m^2$, and 16% packing ratio. And it was found that the amount of nitrate removal by microorganisms attached on the surface of cathode and media (BRM) was 178.2 mg/L and 52.2 mg/L respectively. and the amount of nitrate removal per MLVSS was 0.435 g $NO_3{^-}$-N/g $MLVSS{\cdot}d$ and 0.336 $NO_3{^-}$-N/g $MLVSS{\cdot}d$.