• 제목/요약/키워드: On-column injection

검색결과 165건 처리시간 0.025초

SIG공법에 의한 구조물기초지반에서의 복합지반개량 평가 (Evaluation of Composite Ground Improvement at Structural Foundation Ground by Super Injection Grouing)

  • 김종국;손형호;이호관;성기광
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2002년도 봄 학술발표회 논문집
    • /
    • pp.347-354
    • /
    • 2002
  • In this paper, when structures are constructed in the soft ground with poor bearing capacity at Incheon International Airport(railroad area), as for the grouting columns built In soft ground by high pressure jet grouting with Triple tube rod(super injection grouting), the effects on reinforcement and bearing capacity of ground are investigated. A unconfined compressive strength tests has been performed on the specimens sampled from the grouting columns and a mass plate bearing test has been performed on a grouting column. The test results show that super injection grouting has a sufficient effect on composite ground improved of foundation ground and reatraint of settlement of structure.

  • PDF

직렬식 분무오리피스를 적용한 회전 연료분사노즐의 분무특성연구 (An Experimental Study of the High-Speed Rotating Fuel Injection System with In-line Injection Orifice)

  • 장성호;최성만
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2009년도 제33회 추계학술대회논문집
    • /
    • pp.202-206
    • /
    • 2009
  • 고속회전 연료분사시스템의 분무특성을 연구하였다. 분무특성에 영향을 주는 직렬식 분무오리피스의 직경을 각각 1mm, 2mm, 3mm, 4mm, 5mm와 분무오리피스 수를 3개, 6개, 12개로 변화시켜가며 분무특성 연구를 수행하였다. PDPA 측정 시스템을 이용하여 분무입자의 크기와 속도, 분무분포 등을 측정하였고, 고속카메라를 이용하여 분무가시화를 수행하였다. 실험결과, 분무오리피스로부터 분출된 단일 액주의 길이는 회전속도에 의해 제어되며, 분무입자의 크기(SMD)는 분무오리피스의 직경과 수가 증가함에 따라 작아지는 경향을 보였다. 결국 분무입자의 크기를 제어하는 기본 메커니즘은 분무 오리피스내의 액막의 두께에 의해 결정됨을 알 수 있었다.

  • PDF

Effects of Synthesis Method, Melamine Content and GPC Parameter on the Molecular Weight of Melamine-Urea-Formaldehyde Resins

  • KIM, Minjeong;PARK, Byung-Dae
    • Journal of the Korean Wood Science and Technology
    • /
    • 제49권1호
    • /
    • pp.1-13
    • /
    • 2021
  • This study was conducted to investigate the effects of the synthesis method, melamine content, and GPC parameters (such as flow rate, column-detector temperature, and sample injection temperature) on the molecular weight of melamine-urea-formaldehyde (MUF) resins. Two different synthesis methods were employed. In the first method, MUF-A resins were synthesized by simultaneously reacting urea, formaldehyde, and melamine (5%, 10%, and 20%) using the reaction of alkaline-acid-alkaline steps under controlled temperature and viscosity. In the second method, MUF-B resins were synthesized by first reacting melamine at the same levels with formaldehyde and then by adding urea. The highest weight average molecular weight (Mw) of MUF-A resins was found at 10% melamine content when the flow rate was 0.3 and 0.8 ml/min; Mw decreased slightly at 20% melamine content. The results showed that Mw increased with an increase in the melamine content when the flow rate was 0.5 and 1.0 ml/min. In addition, Mw was the highest when the flow rate, column-detector temperature, and injection temperature were 0.3 ml/min, 50℃, and 25℃, respectively. On the contrary, MUF-B resins had greater Mw and number average molecular weight (Mn) than MUF-A resins. Overall, Mw and Mn increased as the melamine content increased. The optimal GPC parameter for MUF resins was determined as follows: a flow rate of 0.5 ml/min, a column-detector temperature of 50℃, and a sample injection temperature of 50℃.

폴리염화비닐 의료용기의 가소제의 정량 및 용출에 관한 연구 (Analytical Studies on Leaching of Plasticizers from Medical Grade Polyvinyl Chloride Containers)

  • 이민화
    • Journal of Pharmaceutical Investigation
    • /
    • 제16권3호
    • /
    • pp.106-109
    • /
    • 1986
  • The elution of di(2-ethylhexyl) phthalate (DEHP) from flexible bags into human blood or transfusion was studied. The conditions of determination of DEHP using high performance liquid chromatography (HPLC) was established as follows: Condition I-column, ${\mu}-Bondapak^{TM}\;C_{18}$; mobile phase, methanol: water=91 : 9 ; flow rate, 1.2ml/min; wavelength, 254nm; injection volume, $10{\mu}l$. Condition II-column, Lichorsorb RP-18$(10{\mu}m)$; mobile phase, methanol: water=94 : 6 ; flow rate, 1.1ml/min; wavelength, 254nm; injection volume, $10{\mu}l$. DEHP was found to be migrating from PVC blood and total parentral nutrient bags into methanol, but not into anti, coagulant drug solution.

  • PDF

UV 경사노광에 의한 미세광학패턴 LCD-도광판 (Development of Micro-Optical Patterned LCD-LGP using UV Inclined-Exposure Process)

  • 황철진;김종선;고영배;허영무
    • 한국소성가공학회:학술대회논문집
    • /
    • 한국소성가공학회 2005년도 춘계학술대회 논문집
    • /
    • pp.51-54
    • /
    • 2005
  • Light Guide Plate (LGP) of LCD-BLU(Back Light Unit) is manufactured by forming optical pattern with $5\~100um$ in diameter on the LGP by means of sand blasting or etching method. However, in order to improve the luminance of LCD-LGP, the design of optical pattern has introduced UV inclined-exposure process in this study. This micro-optical pattern, which has asymmetric elliptical column shaped pattern, can change low viewing-angle to high viewing-angle, as well as it contribute to diffusion of light. As a result, this type of micro-optical pattern can introduce the highly luminance. The PR structure obtained in the stage of lithography has asymmetric elliptical column shape and it is processed into a micro-optical pattern. Optical design with this kind of micro-optical pattern, mold fabrication by electroplating and LGP molding with injection molding are under way.

  • PDF

Multi-scale Driving of Turbulence and Astrophysical Implications

  • Yoo, Hyunju;Cho, Jungyeon
    • 천문학회보
    • /
    • 제38권2호
    • /
    • pp.61.1-61.1
    • /
    • 2013
  • Turbulence is a common phenomenon in astrophysical fluids such as the interstellar medium (ISM) and the intracluster medium (ICM). In turbulence studies it is customary to assume that fluid powered by an energy injection on a single scale. However, in astrophysical fluids, there can be many different driving mechanisms that act on different scales simultaneously. In this work, we assume multiple energy injection scale (2${\surd}$12 and 15

  • PDF

한지자숙폐액을 이용한 Saccharomyces cerevisiae의 배양에서 온-라인 FIA시스템에 의한 Glucose의 자동분석 및 첨가에 의한 증균 (Increase of Cell Concentration by the Automatic Analysis and Addition of glucose with an On-line Flow Injection Analysis System int he Cultivation of Saccharomyces cerevisiae Using a Korean Paper Digestion Wastewater)

  • 이형춘
    • KSBB Journal
    • /
    • 제15권4호
    • /
    • pp.388-392
    • /
    • 2000
  • 한지자숙폐액을 이용한 Saccharomyces cerevisiae의 배양에 서 glucose의 자동분석 및 첨가에 의해 균농도를 증가시킴으로써 폐액의 재이용성을 향상시키파 하였다 배양액의 glucose를 자동분석하고 자동첨가하기 위하여 ceramic sampler, sampling, ralve, injection valve, glucose oxidase column, debubbler, flow cell과 백금전극, potentiostat, computer와 interface card, 및 tubing pump블로 구성된 glucose 자동분석 및 첨가시스템을 제작하였으며, glucose의 자동분석에는 glucose oxidase를 이용한 on-line FIA법을 채택하였다. 효모의 배양중 glucose자 동분석 및 첨가시스템을 사용하여 glucose를 자동첨가한 결과 배양액의 포도당농도가 $176{\pm}31 mg/L$ 의 낮은 농도로 제어 되었으며, glucose와 $>(NH_4)_2S0_4$의 첨가에 의해 총균수가 3.1 배 증가하였다.

  • PDF

제조용 액체 크로마토그래피에서 HETP에 영향을 미치는 인자 (Factors Affecting HETP in Preparative Liquid Chromatography)

  • 최두찬;최대기;노경호
    • 공업화학
    • /
    • 제7권5호
    • /
    • pp.985-991
    • /
    • 1996
  • HETP(Height Equivalent to a Theoretical Plate)는 크로마토그래피 공정에서 관의 효율을 나타내는 정량적 인자이다. 본 연구에서는 시료의 농도와 주입량, 이동상의 유속과 조성이 제조용 액체 크로마토그래피의 HETP에 미치는 영향을 고찰하였다. 시료는 thymidine이고 이동상은 1.5~5.5ml/min의 유속에서 일정용매조성법으로 물과 organic modifier로서 메탄올을 사용하였으며 제조용 크로마토그래피 column은 길이가 500mm, 내경이 9.8mm이다. 시료의 농도와 주입부피 및 유속이 증가함에 따라 HETP는 거의 선형적으로 증가하여 관의 효율이 감소하였다. 시료 주입부피의 영향은 관의 효율에 매우 중요하게 작용하여 동일한 주입량에 대하여 주입부피가 10배로 증가함에 따라 HETP는 약 2배 정도로 커졌다. 이동상의 유속이 증가함에 따라서 HETP는 주로 이동상과 고정상의 물질전달저항에 의해서 증가하였다.

  • PDF

An Experimental Study of the Micro Turbojet Engine Fuel Injection System

  • Choi, Hyun-Kyung;Choi, Seong-Man;Lee, Dong-Hun
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2008년 영문 학술대회
    • /
    • pp.1-5
    • /
    • 2008
  • An experimental study was performed to develop the rotational fuel injection system of the micro turbojet engine. In this system, fuel is sprayed by centrifugal forces of engine shaft. The test rig was designed and manufactured to get droplet information on combustion space. This experimental apparatus consist of a high speed rotational device(Air-Spindle), fuel feeder, rotational fuel injector and acrylic case. To understand spray characteristics, spray droplet size, velocity and distribution were measured by PDPA (Phase Doppler Particle Analyzer) and spray was visualized by using Nd-Yag laser-based flash photography. From the test results, the length of liquid column from injection orifice is controlled by the rotational speeds and Sauter Mean Diameter(SMD) is decreased with rotational speed. Also, Sauter Mean Diameter is increased as increasing mass flow rate at same rotational speeds.

  • PDF

Adsorption/desorption of uranium on iron-bearing soil mineral surface

  • Ha, Seonjin;Kyung, Daeseung;Lee, Woojin
    • Advances in environmental research
    • /
    • 제4권2호
    • /
    • pp.135-142
    • /
    • 2015
  • In this study, we evaluated the adsorption/desorption of uranium (U) in pure soil environment using continuous column reactor. We additionally investigated the adsorption/desorption mechanism of U on vivianite surface in molecular scale using quantum calculation. We observed that below $0.1{\mu}M$ of U was detected after 20 d from U injection ($1{\mu}M$) in adsorption test. However, all of absorbed U was detached from vivianite surface in 24 h by injection of CARB solution ($1.44{\times}10^{-2}M\;NaHCO_3$ and $2.8{\times}10^{-3}M\;Na_2CO_3$). Based on exchange energy calculation, we found that $UO_2(CO_3)_2{^{2-}}$ and $UO_2(CO_3)_3{^{4-}}$ species have higher repulsive energy than $UO_2(OH)_2$ species. The results obtained from this study could be applied to predict the behavior of uranium in contaminated and remediation sites.