• Title/Summary/Keyword: On-air

Search Result 29,041, Processing Time 0.058 seconds

Estimation of Air Voids of Asphalt Concrete Using Non-destructive Density Testing (비파괴 밀도시험을 통한 아스팔트 콘크리트의 공극률 추정 연구)

  • Na, Il-ho;Lee, Sung-Jin;Yoon, Ji-Hyeon;Kim, Kwang-Woo
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.60 no.6
    • /
    • pp.111-119
    • /
    • 2018
  • The air-void is known to be one of the influencing factors for estimating long-term performance of asphalt concrete. Most of all, confirming air void or density of pavement layer is important for quality control of field compaction level of asphalt concrete pavement. In this study, a non-nuclear type non-destructive density gage (NDDG) was used to estimate compacted air-voids of asphalt pavement as a non-destructive test method. Asphalt concrete slab specimens were prepared using 6 types of asphalt mixes in laboratory (lab) for lab NDDG test. Four different base structure materials were used to find out if there were any differences due to the type of base structure materials. The actual air-voids and NDDG air-voids were measured from 6 asphalt concrete slabs. Four sections of field asphalt pavements were tested using the NDDG, and actual air voids were also measured from field cores taken from the site where the NDDG air-void was measured. From lab and field experimental tests, it was found that the air-voids obtained by NDDG were not the same as the actual air-voids measured from the asphalt concrete specimen. However, it was possible to estimate air voids based on the relationship obtained from regression analysis between actual and NDDG air voids. The predicted air-voids based on the NDDG air-voids obtained from 50mm depth were found to be reliable levels with $R^2{\fallingdotseq}0.9$. Therefore, it was concluded that the air-voids obtained from NDDG could be used to estimate actual air-voids in the field asphalt pavement with a relatively high coefficient of determination.

Evaluation of Indoor Thermal Environment According to Air-Barrier Air Conditioning System in Perimeter Zone (페리미터존의 에어배리어 공조방식에 따른 실내 열환경 평가)

  • Park Byung-Yoon;Ham Heung-Don;Sohn Jang-Yeul
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.17 no.4
    • /
    • pp.370-376
    • /
    • 2005
  • For the purpose of investigating the effective removal of heating/cooling load from light-weighted building envelope, two air-conditioning systems, conventional parameter air-conditioning system and air-barrier system, are evaluated and compared by both experiment and simulation with six different cases during heating and cooling season. In addition, the characteristics of window-side building thermal load are assessed by varying supply air velocity in order to seek the optimal system operation condition. The results are as follows. 1) Air-barrier system is more effective to remove heating/cooling load at perimeter zone than conventional parameter air-conditioning system. Moreover, the better effectiveness appears during cooling season than during heating season. 2) The experiment during cooling season provides that indoor temperature of air-barrier system shows $1^{\circ}C$ less than that of the conventional system with similar outdoor air temperature profile, and indoor temperature distribution is more uniform throughout the experimented model space. It concludes that air-barrier system can achieve energy saving comparing to the conventional system. 3) The capturing efficiency of air-barrier system is 0.47 on heating season and 0.2 on cooling season with the same supply air volume. It results that the system performs effectively to remove building thermal load, moreover demonstrates high efficiency during cooling season. 4) The simulation results provide that capturing efficiency to evaluate the effective removal of building load from perimeter zone shows high value when supply air velocity is 1 m/s.

Evaluation of proper particle cleaned air delivery per hour (PCH) for controlling indoor air quality in passenger car cabin (자동차 캐빈 공기질 제어를 위한 적정 입자청정횟수 평가)

  • Kwang Chul Noh;Tae Wook Kim;Sang Woo Kim;Cheong Ha Hwang;Bangwoo Han
    • Particle and aerosol research
    • /
    • v.20 no.2
    • /
    • pp.47-56
    • /
    • 2024
  • In this study, an empirical study was conducted to investigate the clean air delivery rate (CADR) and the proper particle cleaned air delivery per hour (PCH) of the air cleaning device installed in passenger car cabin. Changes in internal particle concentration were measured in the cabins of the pick-up type engine-driven car and the electric vehicle depending on cabin air filters, ventilation modes, and blower settings. In the tested cars, PM2.5 collection efficiency of the HEPA filter was higher than that of the genuine filter. The PM2.5 collection efficiency of each cabin air filter was measured to be similar regardless of the blower setting of the tested cars. This means that the higher the blower setting, the higher the CADR and the PCH. The infiltration rate varies depending on the air tightness of the car. The cabin was more contaminated with particles under driving. From the CADRs measured inside the passenger car cabin, the recirculation mode of HVAC system is a more effective for managing ultrafine particles than the fresh air mode. From a few assumptions, the proper PCH was derived about 0.8 times/min (48 times/h). From this result and several experiments, the proper operation setting of air cleaning device installed inside cars can be found out to control indoor air quality. Also, an appropriate operation settings of HVAC system can be found with considering cooling and heating conditions for thermal comfort in passenger car cabin.

Empirical study on evaluation of performance and filter replacement cycle of air cleaners installed in subway station (지하역사 공기청정기 성능평가 및 필터 유지보수 실증 연구)

  • Kwang Chul Noh;Sang Woo Kim;Cheong Ha Hwang
    • Particle and aerosol research
    • /
    • v.20 no.2
    • /
    • pp.69-77
    • /
    • 2024
  • In this study, the performance of air cleaners installed in subway stations was evaluated using field test method and chamber test method in accordance with the standard for air cleaner. Also, the air filter maintenance period was examined by the performance reduction of air cleaners with respect to the air filter usage period. From the field tests, the clean air delivery rate (CADR) of air cleaners with filter in use was about 85% on average compared to the ones with new filter. The main factor of CADR reduction was not the decrease of filter efficiency but the decrease of airflow rate. The chamber test results shows that the CADR of air cleaners decreased with the usage time, but the proper filter replacement can make the CADR keep about 95% of the certified CADR. The expected filter replacement cycle measured by the field test method was calculated to be approximately 3.35 months (100 days). However, the replacement cycle was a large difference between 1.2 and 6.6 months with the different stations. Therefore, the replacement cycle should be individually investigated for each station. The use of air cleaners must be effective in reducing fine dust in subway stations. For more effective air quality management in subway stations, additional researches is necessary to define the appropriate capacity of HVAC system and air cleaner, and related maintenance for each station.

A Study for Improving Thermal Performance According to Variables of Perforated Baffle in Air-type PVT Collector (공기식 PVT 컬렉터에 적용된 타공 베플의 변수에 따른 열 성능 향상을 위한 연구)

  • Yu, Ji-Suk;Kim, Jin-Hee;Kim, Jun-Tae
    • Journal of the Korean Solar Energy Society
    • /
    • v.39 no.6
    • /
    • pp.83-91
    • /
    • 2019
  • Photovoltaic thermal (PVT) collectors are devices that simultaneously produce electricity and heat. Research on conventional air-type PVT collector focuses on installing baffles to enhance the collector's thermal performance. However, the baffles have pressure drop inside the collector which degrades the thermal performance. Thus, it is necessary to design baffles to smoothen the flow inside the air-type PVT collector. Alternatively, installing perforated baffles in air-type PVT collectors can reduce the collector weight, but parameters such as the diameter of the perforated holes and the height of the perforated plates should be considered. Therefore, the main aim of this study was to analyze thermal characteristics of each variable of perforated baffles installed inside air-type PVT collector. For this purpose, the uniformity of air flow in the collector was compared through NX program, and the resultant heat gain and thermal efficiency of the air-type PVT collector were compared and analyzed. Therefore, the main aim of this study was to analyze thermal characteristics of each variable (Baffle angle, length, height, pitch, perforated ratio) of perforated baffles installed inside air-type PVT collector. For this purpose, the uniformity of air flow in the collector was compared through CFD program, and the resultant heat gain and thermal efficiency of the air-type PVT collector were compared and analyzed. As a result, the maximum outlet temperature was increased by 1.45 times and the heat gain was increased by 193.8 Wth, depending on the perforated baffle plate, compared to the collector without the baffle. The heat transfer performance showed that the maximum internal velocity was 1.61 times higher and the Reynolds number was 1.06 times higher depending on the parameters of the baffle plate.

The Influence of Air Pollution Level on Resident's Evaluation and Cognition for Indoor Environment in Ulsan (울산지역의 대기오염 환경의 차이가 거주자의 실내환경 평가 및 인식에 미치는 영향)

  • Yoo, Bok-Hee
    • Journal of the Korean housing association
    • /
    • v.21 no.3
    • /
    • pp.87-94
    • /
    • 2010
  • The aim of this study was to evaluate the influence of air pollution level in industrial and residential district of Ulsan on resident's evaluation and cognition for indoor environment. The evaluation of air pollution materials (as $SO_2$, $NO_2$, $O_3$, CO, PM10) were investigated to understand the distributional characteristics in survey area, and air quality monitoring data from 2007 to 2009 were used. The data was applied in a realtime measurement of industrial and residential area respected to difference of the pollution level in Ulsan. The questionnaire of this survey for resident's cognition was to find out characteristics on perception of indoor environment and outdoor air quality recognition based on the distinct characteristics of the areas. The results of this study shows that resident's satisfaction at clean level outdoor air and indoor environment were different whether it was residential area or industrial area and outdoor air pollution level has direct influence on resident's satisfaction in indoor environment.

An Experimental Study on Cooling Characteristics of Mist Impinging Jet on a Flat Plate (평판에 분사된 분무충돌제트의 냉각특성에 대한 실험적 연구)

  • Jun, Snag-Uk;Jung, Won-Seok;Lee, Joon-Sik
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.27 no.4
    • /
    • pp.511-517
    • /
    • 2003
  • An experiment is conducted to investigate the effect of air and water mass flow rates on cooling characteristics of mist impinging jet on a flat plate. The air mass flow rate ranges from 0.0 to 3.0 g/s, and water mass flow rates from 5.0 to 20.0 g/s. An air-atomizing nozzle is used fur the purpose of controlling air and water mass flow rates. The test section is designed distinctively from previous works to obtain local heat transfer coefficient distributions. Heat transfer characteristics of the mist impinging jet are explained with the aid of flow visualization. Surface temperature and heat transfer coefficient distributions become more uniform as air mass flow rate increases. The water flow rate provides substantial contribution to enhancement of cooling performance. On the other hand, The air mass flow rate weakly influences the averaged heat transfer rate when the water mass flow rate is low, but the averaged heat transfer rate Increases remarkably with the air mass flow rate in case of the high water mass flow rate.

Analysis of Contact Pressure for a 300mm Wafer Polishing Table with Air-Bag Head (Air-Bag Head 가압식 300mm 웨이퍼 폴리싱 테이블의 가압 분포 해석)

  • Ro, Seung-Kook
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.22 no.2
    • /
    • pp.310-317
    • /
    • 2013
  • In this paper, the contact pressure of the wafer and polishing pad for final polishing process for 300 mm-wafer were investigated through numerical analysis using FEM tool, ANSYS. The distribution of the contact pressure is one of main parameters which affects on the flatness and surface roughness of polished wafers. Two types of polishing head, a hard type head with ceramic disk and a soft type head with air bag were considered. The effects of the deformation and initial shape of table on the contact pressure were also examined. Both heads and tables were modeled as 3D finite element model from solid model, and the material properties of polishing pads and rubber plate for the air-bag head were obtained from tensile tests. The contact pressure deviation on wafer surface was smaller with air bag head than hard type head even when the table had form errors such as convex or concave. From this 3D analysis, it could be concluded that the air-bag head has better uniformity of the contact pressure on wafer. Also, the effects of inner diameter of air bag and radial clearance between wafer and retainer were investigated as view point of contact pressure concentration on the edge of wafer.

Analysis on the Dielectric Characteristics of Dry Air According to Pressures for Developing an Eco-friendly High Voltage Switchgear (친환경 고압배전반 개발을 위한 dry air의 압력별 절연내력특성 분석에 관한 연구)

  • Nam, Seok-Ho;Kang, Hyoung-Ku
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.8
    • /
    • pp.1560-1565
    • /
    • 2011
  • The environmental pollution caused by green-house gases such as $CO_2$ and $SF_6$ has been becoming the main issue of industrial society. Many developed countries are making efforts to minimize the amount of $CO_2$ emission come from the operation of high voltage electrical apparatuses. As a part of these efforts, 180 countries signed the Kyoto Protocol in 1997 to cut back on their green-house gas emissions. Nowadays, the study on the development of dry air insulated switchgear (DAIS) which is known as an eco-friendly electrical apparatus is in progress. A DAIS is advantageous for minimizing the effect of impurities and enhancing the dielectric characteristics over an air insulated switchgear (AIS) by applying constant pressure to an enclosed cubicle. Therefore, a study on the electrical insulation performance of dry air as a gaseous insulation medium is conducted in this paper to substitute a gas insulated switchgear (GIS) for DAIS. As results, it is verified that the AC dielectric characteristics of dry air are similar to those of air and the lightning impulse dielectric characteristics of dry air are superior to those of air at 1bar pressure condition. However, dry air is of inferior dielectric characteristics to $SF_6$ at 4bar pressure condition. Finally, it is suggested that the internal pressure of DAIS should be over 4bar pressure to develop a high voltage switchgear which has similar electrical performance to a conventional GIS. Also, the empirical formulae on calculating the maximum electric field intensity at sparkover of dry air are deduced by experiments according to pressures. It is expected that these results are helpful to design and develop a high voltage electrical apparatus.

The Legislation of the Part VI (the Carriage by Air) of the Korean Commercial Code (국내 항공운송법 제정안에 관한 고찰)

  • Choi, June-Sun
    • The Korean Journal of Air & Space Law and Policy
    • /
    • v.23 no.2
    • /
    • pp.3-29
    • /
    • 2008
  • The volume of air passengers and cargo transportation has increased rapidly in recent years. This trend will be even more noticeable as the high-tech service industry expands and the globalization progresses. In an effort to reflect and to cope with this trend, many conventions concerning international air transportation have been concluded. The Republic of Korea has also acceded to the Montreal Convention of 1999 on September 20th, 2007 which became effective on December 29th 2007. However, Korea currently does not provide any private law on the liability of domestic air carrier, leaving the regulation wholly to the general conditions of carriage of private air lines. These general conditions of carriage, however, are not sufficient to regulate the liabilities of domestic air carriers, because they cannot be fully recognized as a legitimate source of law applicable in the court. This situation is inconvenient for both air carrier and their customers. Thus, the Ministry of Justice of Korea has decided to enact a law that will regulate domestic air transportation, namely, "Domestic Carriage by Air Act", as a part of the Korean Commercial Code. So was composed a special committee for legislation of the Domestic Carriage by Air Act. This writer has led the committee as a chairman. The committee has held in total 10 meetings so far and has completed a draft bill for the part VI of the Korean Commercial Code, "Air Carriage." The essentials of the draft are as follows: First, the establishment of Part VI in the Commercial Code. The Korean Commercial Code already includes a series of provisions on road transportation in part II and carriage by sea in part V. In addition to these rules regulating different types of transportation, the Domestic Carriage by Air Act will newly establish part VI to regulate air carriages. Eventually, the Commercial Code will provide an integrated legal system on the transportation industry. Second, the acceptance of the basic liability system which major international conventions, such as Montreal Convention of 1999 and Guadalajara Convention of 1961, have adopted. This is very important, because the law of air carriage is unified worldwide through various international conventions, making it necessary and significant for the new act to achieve conformity between rules of international air carriage and that of domestic air carriage. Third, the acceptance of Rome Convention system on damage caused by foreign aircraft to third parties on the surface. Fourth, the application of rules on domestic road carriage or carriage by sea mutatis mutandis with necessary modifications. This very point is the merit of inserting domestic air transportation law into the Commercial Code. By doing so, the number of articles can be reduced and the rules on air carriage can conform to that of road transportation and carriage by sea. The bill is expected to be passed by the parliament at the end of this year and is expected to be effective by end of July 2009.

  • PDF